Kyocera FS-C5100, FS-5200, FS-5300, FS-5400 SERVICEBULLETINS 2HG 003

Service Bulletin
SB Number:
Subject:
SB 2HG-003
Firmware upgrade (sleep timer delay and error code F186)
Creation Date: 19/11/2009
Contents of changes
Firmware Type Program No. Check SUM Version
Item Contents
1 Delay when setting the auto sleep
timer.
2 Processing lock or error code F186. A processing lock or error code F186 may occur when
SYSTEM 2HG_3000003001 2787 003.001
When setting the sleep timer, the timing may be delayed with 36 seconds, due to ASIC setting error. (e.g. timer is set to 4 hours, the auto sleep mode is
activated 36 seconds later)
using a DIMM which is not listed in the guide line.
Classication
Field measure When the above mentioned phenomena occur, please upgrade the rmware to the latest version.
Serial numbers of affected machines
Type Serial number
FS-C5400DN XAC9800467
Machines produced after the above mentioned serial number, should not have the above mentioned phenomena.
Entire stock rework
In-eld modication at next visit
In-eld modication by case
No modication necessary
KMIS Service Department, Kyocera Mita Europe 8990 / SB 2HG-003