<Date> December 28, 2011
Firmware Upgrade (Main: Ver.004.004; MMI: Ver.004.008; Optional Language Brazilian Portuguese: Ver.001.008)
Model
FS-3540MFP, FS-3640MFP
Topic
The firmware was upgraded as follows.
Content of Changes
No.
1 Catalan language
2 Operability improvement
for the MP paper size and media type selection
3 Correction of the
Brazilian Portuguese messages
For more details, please refer to the next pages.
Item Details
Catalan is now supported as an optional language.
(1) The MP tray paper size and the media type are now changeable from the paper selection on the Copy screen. (2) The MP tray paper size and the media type are now changeable at paper empty.
Example) The message which should be "No. of attention" was
“Attention1”.
Therefore, this was corrected.
Program No.
MAIN 2MC_2F00004004 - 004.004 2011/10/25 003.024 FS-3540MFP
MAIN 2MD_2F00004004 - 004.004 2011/10/25 003.024 FS-3640MFP
MMI 2MC_7000004008 - 004.008 - 003.020
ENGINE 2MC_1000003002 - 003.002 - - SCANNER 2MC_1200003001 - 003.001 - -
Optional
FAX BOOT
2MC_81BR001008
2KX_5500007001 - 007.001 - -
CHECK
SUM
- 001.008 - 001.006
Ver. Status Date
Current
Ver.
Remark
Brazilian
For the KM sales companies, it is possible to download the firmware at the download center on the ESDC.net. When upgrading the firmware or replacing a board, please upgrade all kinds of the firmware to the latest version at the same time.
KMC’s Classification Entire Stock Rework In-Field modification at next visit
In-Field modification by case No modification necessary
Field Measure: Please upgrade the firmware when the problem described above arises.
Serial Nos. of the Affected Machines: From the available timing in the December 2011* production
*The above is the plan at the present moment. Please note that this information is subject to change.
CTL FW
608655 576620
573675
580239
←←←← New upgrade
←←←← New upgrade
←←←← New upgrade
←←←← New upgrade
MAIN MMI
MMI
LANG BR
European Service & Development Center (ESDC)
No.
application
(Pcounter)
Korean only.
Reader)
failure
Timer
was corrected.
setting
s
Service Bulletin Ref. No.
<Date> December 28, 2011
Item Details
4 Measures against the
system error
5 Measures against the
scanning failure
6 Measures against the
counter acquisition failure with the HyPAS
The system error might appear when print job was performed while storing about 4,000 of PCL macro data. Therefore, this was corrected.
Scanning of a large number of originals might fail after starting up the PC. Therefore, this was corrected.
Copy counter information acquisition might fail with the HyPAS application (Pcounter). Therefore, this was corrected.
(Page.2/4)
2MC-0004 (B465)
CTL FW
605874 TO-11-026 KMA-D-1105-03
604771 TO-11-048 KMA-D-1107-03
604782 TO-11-038 KMA-D-1106-11
MAIN
MAIN
MAIN
7 Measures against the
illegible Korean Command Center view
8 Measure against the
error message in Equitrac environment (without ID Card
9 Measures against the
sender information failure
10 Measures against the
system error (CF264)
11 Measures against the
SMB protocol printing
12 Daylight saving time
support for the Weekly
13 "admin00" password
support
14 Preventive measure
against overwriting of the Command Center
Hangul fonts in Korean Command Center seemed to be corrupted. Therefore, the magnification of the browser was set to 120% for
A message "Cannot recognize the ID card reader" was displayed as sub message even if ID Card Reader was not connected when executing Equitrac application activation. Therefore, this was corrected so that the message above will not be displayed.
The sender information was not printed on the recipients output data when sending FAX if the Job Account setting was ON, but Job Account name was not defined at the extensible authentication. Therefore, this was corrected.
The CF264 error might appear when printing the PCL macro data using a CF card. Therefore, this was corrected.
LF code might be ignored in the SMB protocol printing. Therefore, this was corrected.
Weekly Timer might not function with the directed time when the summer time (daylight saving time) mode was set. Therefore, this
----------
----------
575018 TO-11-051
574912 TP-10-201 KMAUS10-S07 Call#1061179
572189 TO-11-045 KME110728-2
605872 TP-11-160 UT-S11-025-1
608320 TP-11-109 NP-Z1103
606351 TO-11-053 UT-S11-027
608334 TO-11-003 #1160788 #1160792
608336 TO-11-007 #1160788
MAIN
MAIN
MAIN
MAIN
MAIN
MAIN
MAIN
MAIN
European Service & Development Center (ESDC)
Loading...
+ 2 hidden pages