Kymco MO MXer Service Manual - chap 14 (ricarica)

14. BATTERY/CHARGING SYSTEM/
A.C. GENERATOR
14-0
MX’er SYSTEM
14
__ __ ___ __ __ __ __ ___ __ __ __ __ _ __ __ __ __ ___ __ __ __ __ ___ __ __ __ __ _ __ __ __ __ ___ __ __ __ __ ___ __
__ __ ___ __ __ __ __ ___ __ __ __ __ _ __ __ __ __ ___ __ __ __ __ ___ __ __ __ __ _ __ __ __ __ ___ __ __ __ __ ___ __
__ __ ___ __ __ __ __ ___ __ __ __ __ _ __ __ __ __ ___ __ __ __ __ ___ __ __ __ __ _ __ __ __ __ ___ __ __ __ __ ___ __
__ __ ___ __ __ __ __ ___ __ __ __ __ _ __ __ __ __ ___ __ __ __ __ ___ __ __ __ __ _ __ __ __ __ ___ __ __ __ __ ___ __
BATTER/CHARGING SYSTEM/
A.C. GENERATOR
__ __ ___ __ __ __ __ ___ __ __ __ __ _ __ __ __ __ ___ __ __ __ __ ___ __ __ __ __ _ __ __ __ __ ___ __ __ __ __ ___ __
SERVICE INFORMATION -------------------------------------------- 14- 2
TROUBLESHOOTING ------------------------------------------------- 14- 3
BATTERY REMOVAL ------------------------------------------------- 14- 4
CHARGING SYSTEM -------------------------------------------------- 14- 5
REGULATOR/RECTIFIER -------------------------------------------- 14- 6
A.C. GENERATOR CHARGING COIL -------------------------------- 14- 7
14
14. BATTERY/CHARGING SYSTEM/
A.C. GENERATOR
14-1
MX’er SYSTEM
CHARGING CIRCUIT
Fuse/Battery
Regulator/Rectifier
A.C. Generator
Ignition Switch
14. BATTERY/CHARGING SYSTEM/
A.C. GENERATOR
14-2
MX’er SYSTEM
SERVICE INFORMATIONN
GENERAL INSTRUCTIONS
The battery can be charged and discharged repeatedly. If a discharged battery is not used for a
long time, its service life will be shortened. Generally, the capacity of a battery will decrease after it is used for 2_ 3 years. A capacity-decreased battery will resume its voltage after it is recharged but its voltage decreases suddenly and then increases when a load is added.
When a battery is overcharged, some symptoms can be found. If there is a short circuit inside the
battery, no voltage is produced on the battery terminals. If the rectifier won‘t operate, the voltage will become too high and shorten the battery service life.
If a battery is not used for a long time, it will discharge by itself and should be recharged every 3
months.
A new battery filled with electrolyte will generate voltage within a certain time and it should be
recharged when the capacity is insufficient. Recharging a new battery will prolong its service life.
Inspect the charging system according to the sequence specified in the Troubleshooting.
Do not disconnect and soon reconnect the power of any electrical equipment because the electronic
parts in the regulator/rectifier will be damaged. Turn off the ignition switch before operation.
It is not necessary to check the MF battery electrolyte or fill with distilled water.
Check the load of the whole charging system.
Do not quick charge the battery. Quick charging should only be done in an emergency.
Remove the battery from the motorcycle for charging.
When replacing the battery, do not use a traditional battery.
When charging, check the voltage with an voltmeter.
SPECIFICATIONS
Item
Standard
Capacity/Model
12V-8AH
Voltage
Fully charged
13.1V
Battery
(20℃ )
Undercharged
12.3V
Charging current
STD: 0.9A Quick: 3.0A
Charging time
STD: 5_ 10hr Quick: 30min
Capacity
0.114KW/5000rpm
A.C. Generator
Charging coil resistance
Yellow_ Pink
Type
Single-phase half-wave SCR
12.0_ 14.0V/5000rpm (Electric tester,
Limit voltage
10_ 13.0V/5000rpm
Charging
13.5_ 15.5V/5000rpm
Lighting
Regulator/Rectifier
The battery electrolyte (sulfuric acid) is poisonous and may seriously damage the skin and eyes. Avoid contact with skin, eyes, or clothing. In case of contact, flush with water and get prompt medical attention