DIGITAL MULTIMETER SELECTOR GUIDE
ektronix / Keithley DMM Comparison Table
T
DIGITAL MULTIMETER SELECTOR GUIDE
HIGH SPEED,
HIGH ACC URACY
Touchscreen,
5 in. (12.7 cm)
7½
VFD
7½
10
HIGH ACCURACY MULTI-CHANNEL MEASUREMENT
VFD
7½
10
VFD
8½
10
VFD
6½
80
VFD
6½ 6½
80
Touchscreen,
5 in. (12.7 cm)
80 200 576
VFD VFD 2 line
6½ 7½
MODEL
Display
Digits
No. Measurement Channels
MODEL
Display
Digits
No. Measurement Channels
BASIC PERFORMANCE
DMM4020 2110 2100 DMM4040 DMM4050 2000 DMM6500 DMM7510 2010 2001 2002 2700 2701 DAQ6510 2750 3706A
VFD, 2 line
5
½ 5½
LCD 2 line
VFD 2 line VFD, dot matrix VFD, dot matrix
6½
6½ 6½ 6½ 6½
VFD
10
Touchscreen,
5 in. (12.7 cm)
10
DC V OLTS DC V OLTS
Measurement Range
Basic Accuracy
Ratio
DC Peak Spikes
1 µV–1000 V 1 µV–1000 V
0.015% 0.012%
0.1 µV–1000 V
0.0038% 0.0035% 0.0024%
100 nV–1000 V 100 nV–1000 V 100 nV–1000 V 100 nV–1000 V
0.003%
0.0025% 0.0014%
✔ ✔ ✔ ✔ ✔
10 nV–1010 V
10 nV–100 0 V
0.0 0 24%
✔
10 nV–1100 V
0.0024%
Option
✔
1 nV–1100 V
0. 0 0 1%
Option
✔
100 nV–1000 V
0.003%
w/MUX card
100 nV–1000 V 100 nV–1000 V
0.003%
0.0025% 0.003% 0.0025%
w/MUX card w/MUX card
100 nV–1000 V 10 nV–300 V
w/MUX card
Measurement Range
Basic Accuracy
Ratio
DC Peak Spikes
AC VOLTS (TRMS) AC VOLTS (TRMS)
Measurement Range
Basic Accuracy
Bandwidth
dB, dBm
Frequency, Period
1 µV–750 V 1 µV–750 V
0.2%
0.12%
20 Hz–100 kHz 10 Hz–300 kHz
✔
✔ ✔
0.1 µV–750 V
100 nV–1000 V 100 nV–1000 V 100 nV–750 V 100 nV–750 V
0.08% 0.12% 0.12%
3 Hz–300 kHz
✔
✔
3 Hz–300 kHz 3 Hz–300 kHz 3 Hz–300 kHz 3 Hz–300 kHz
✔ ✔ ✔ ✔
✔ ✔ ✔ ✔
0.05%
100 nV–707 V
0.05% 0.06%
3 Hz to 300 kHz
✔
✔
100 nV–750 V
0.05%
3 Hz–300 kHz
✔
✔
100 nV–775 V
0.03%
1 Hz–2 MHz
✔
✔
100 nV–775 V
0.02%
1 Hz–2 MHz
✔
✔
100 nV–750 V
0.06%
3 Hz–300 kHz
✔
100 nV–750 V 100 nV–750 V
0.06%
0.05% 0.06% 0.05%
3 Hz–300 kHz 3 Hz–300 kHz
✔ ✔
100 nV–750 V 100 nV–300 V
3 Hz–300 kHz 3 Hz–300 kHz
✔
✔ ✔
Measurement Range
Basic Accuracy
Bandwidth
dB, dBm
Frequency, Period
OHMS (2/4 WIRE) OHMS (2/4 WIRE)
Measurement Range
Basic Accuracy
Continuity Test
Diode Test
Offset Compensation
Dry Circuit
1 mΩ–100 MΩ 1 mΩ–100 MΩ
0.02%
0.02%
✔ ✔
✔ ✔
100 µΩ–100 MΩ
10 µΩ–1 GΩ 10 µΩ–1 GΩ 100 µΩ–120 MΩ 1 µΩ–120 MΩ
0.015% 0.01% 0.01%
✔
✔
✔ ✔ ✔
✔ ✔ ✔
0.008%
0.1 µΩ–1.2 GΩ
0.0075% 0.0024%
✔ ✔
✔ ✔
✔ ✔
✔
1 µΩ–120 MΩ
0.0032%
✔
✔
✔
✔
1 µΩ–1 GΩ
0.0032%
✔
100 nΩ–1 GΩ
0.0007%
✔
100 µΩ–120 MΩ
0.008%
✔
✔
100 µΩ–120 MΩ 1 µΩ–120 MΩ
0.008%
✔
0.0075% 0.008% 0.004%
✔ ✔ ✔
✔
✔
✔ ✔ ✔
1 µΩ–120 MΩ 100 nΩ–100 MΩ
✔ ✔
Measurement Range
Basic Accuracy
Continuity Test
Diode Test
Offset Compensation
Dry Circuit
DC AMPS DC AMPS
Measurement Range
Basic Accuracy
In Circuit Current
1 nA–10 A 0.1 µA–10 A
0.02%
0.15%
10 nA–3 A 100 pA–10 A 100 pA–10 A
0.055% 0.05% 0.05%
10 nA–3 A
0.03%
10 pA–10 A 1pA–10.1 A
0.02% 0.006%
1 nA–3 A
0.03%
10 pA–2 A
0.03%
✔
10 pA–2 A
0.027%
✔
10 nA–3 A
0.03%
10 nA–3 A
0.03%
10 pA–3 A 10 nA–3 A 1 pA–3 A
0.02% 0.03% 0.03%
Measurement Range
Basic Accuracy
In Circuit Current
AC AMPS (TRMS) AC AMPS (TRMS)
Measurement Range
Basic Accuracy
Bandwidth
0.1 µA–10 A
0.3%
20 Hz–2 kHz
10 µA–10 A
0.3%
10 Hz–5 kHz
1 µA–3 A 100 pA–10 A 100 pA–10 A
0.15% 0.1% 0.1%
3 Hz–5 kHz
3 Hz–10 kHz 3 Hz–10 kHz 3 Hz–5 kHz 3 Hz–10 kHz
1 µA–3 A
0.1%
100 pA–10 A 1 nA–10.1 A
0.1% 0.08%
3 Hz to 10 kHz
1 µA–3 A
0.1%
3 Hz–5 kHz
100 pA–2 A
0.1%
20 Hz–100 kHz
100 pA–2 A
0.1%
20 Hz–100 kHz
1 µA–3 A
0.15%
3 Hz–5 kHz
1 µA–3 A
0.16 %
100 pA–3 A 1 µA–3 A 1 nA–3 A
0.10% 0.15% 0.08%
3 Hz–5 kHz 3 Hz–10 kHz
3 Hz–5 kHz 3 Hz–10 kHz
Measurement Range
Basic Accuracy
Bandwidth
OTHER MEASUREMENTS OTHER MEASUREMENTS
Capacitance
Temperature Measurement
TC, RTD, Thermistor
1 pF–100 µF 0.1 pF–100 µF 0.1 pF–100 µF 0.1 pF–100 µF
RTD TC
TC
TC, RTD, Thermistor TC, RTD, Thermistor
TC, RTD
TC, RTD
TC, RTD
TC, RTD, Thermistor
TC, RTD, Thermistor
TC, RTD, Thermistor TC, RTD, Thermistor TC, RTD, Thermistor
Capacitance
Temperature Measurement
GENERAL FEATURES GENERAL FEATURES
Interface
Reading Hold
Digi tal I /O
Reading Memory
Maximum Speed
RS-232, USB with
adapter cable
✔ ✔
USB, GPIB (opt.)
Trig g e r In
Meter Complete
2000 rdg.
50K rdg /s
USB
✔
Trigger In
Meter Complete
2000 rdg.
2000 rdg/s
GPIB, RS-232,
LAN,
USB with adapter cable
LAN,
GPIB, RS-232,
USB with adapter cable
GPIB, RS-232
LAN/LXI, USB, GPIB
(opt.), RS-232 (opt.)
GPIB, USB, LAN/LXI
✔ ✔
Trig g e r In
Meter Complete
1024 rdg.
2000 rdg/s
Trig g e r In
Meter Complete
7 M rdg. 27.5 M rdg.
1 M rdg/s
(16-bit digitizing)
Trigger In
Meter Complete
6 General I/O
1 M rdg/s
(18-bit digitizing)
GPIB, RS-232
Trig g e r In
Meter Complete
1024 rdg.
2000 rdg/s
GPIB
Trigger In
Meter Complete
1 In, 4 Out
Opt to 30,000
2000 rdg/s
GPIB
Trig g e r In
Meter Complete
1 In, 4 Out
Opt to 30,000
2000 rdg/s
GPIB, RS-232
✔
2 Trigger In, 5 Limit Out
55,000 rdg.
2000 rdg/s
LAN, RS-232
✔
2 Trigger In, 5 Limit Out
450,000 rdg.
350 0 rdg/s
LAN/LXI, USB, GPIB (opt.),
RS-232 (opt.)
Trig g e r In
Meter Complete
7 M rdg. 110,000 rdg. 650,000 rdg.
1 M rdg/s
(16-bit digitizing)
GPIB, RS-232 GPIB, LAN/LXI, USB
2 Trigger In, 5 Limit Out 14 General I/O
2500 rdg/s >14,000 rdg/s
Interface
Reading Hold
Digi tal I /O
Reading Memory
Maximum Speed
Embedded Test
Other
Dual Measurement
Display
Dual Measurement
Display
Script Processor and
optional TSP-Link,
6 Digital I/O with
Interface Options,
Dual Measurement
Embedded Test
Script Processsor and
TSP-LINK
Embedded Test Script
Processor and optional
TSP-Link, 6 Digital I/O with
Interface Options
Embedded Test
Script Processsor and
TSP-LINK
Display
Specifications are subject to change without notice. Copyright © Tektronix 042318.SBG 1KW-61274-1