Juniper Networks EX4200, EX3200 User Manual

4.3 (3)

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

Published: 2010-08-11

Revision 11

Copyright © 2010, Juniper Networks, Inc.

Juniper Networks, Inc.

1194 North Mathilda Avenue Sunnyvale, California 94089 USA

408-745-2000 www.juniper.net

ThisproductincludestheEnvoySNMPEngine,developedbyEpilogueTechnology,anIntegratedSystemsCompany. Copyright©1986-1997, Epilogue Technology Corporation. All rights reserved. This program and its documentation were developed at private expense, and no part of them is in the public domain.

This product includes memory allocation software developed by Mark Moraes, copyright © 1988, 1989, 1993, University of Toronto.

This product includes FreeBSD software developed by the University of California, Berkeley, and its contributors. All of the documentation and software included in the 4.4BSD and 4.4BSD-Lite Releases is copyrighted by the Regents of the University of California. Copyright © 1979, 1980, 1983, 1986, 1988, 1989, 1991, 1992, 1993, 1994. The Regents of the University of California. All rights reserved.

GateD software copyright © 1995, the Regents of the University. All rights reserved. Gate Daemon was originated and developed through release 3.0 by Cornell University and its collaborators. Gated is based on Kirton’s EGP, UC Berkeley’s routing daemon (routed), and DCN’s HELLO routing protocol. Development of Gated has been supported in part by the National Science Foundation. Portions of the GateD software copyright © 1988, Regents of the University of California. All rights reserved. Portions of the GateD software copyright © 1991, D. L. S. Associates.

This product includes software developed by Maker Communications, Inc., copyright © 1996, 1997, Maker Communications, Inc.

Juniper Networks, Junos, Steel-Belted Radius, NetScreen, and ScreenOS are registered trademarks of Juniper Networks, Inc. in the United States and other countries. The Juniper Networks Logo, the Junos logo, and JunosE are trademarks of Juniper Networks, Inc. All other trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners.

Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice.

Products made or sold by Juniper Networks or components thereof might be covered by one or more of the following patents that are owned by or licensed to Juniper Networks: U.S. Patent Nos. 5,473,599, 5,905,725, 5,909,440, 6,192,051, 6,333,650, 6,359,479, 6,406,312, 6,429,706, 6,459,579, 6,493,347, 6,538,518, 6,538,899, 6,552,918, 6,567,902, 6,578,186, and 6,590,785.

EX3200 and EX4200 Ethernet Switches Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

Copyright © 2010, Juniper Networks, Inc. All rights reserved. Printed in USA.

Writing: Appumon Joseph, Aviva Garrett, Greg Houde, Hemraj Rao S, Hareesh Kumar K N, Keldyn West, Shikha Kalra, Steve Levine Editing: Cindy Martin, Rajan V K

Illustration: Faith Bradford Brown Cover Design:

Revision History

15 March 2008—Revision 1

28 April 2008—Revision 2

12 August 2008—Revision 3

30 January 2009—Revision 4

14 April 2009—Revision 5

20 July 2009—Revision 6

4 November 2009—Revision 7

18 December 2009—Revision 8

17 February 2010—Revision 9 May 2010—Revision 10 August 2010—Revision 11

The information in this document is current as of the date listed in the revision history.

YEAR 2000 NOTICE

ii

Copyright © 2010, Juniper Networks, Inc.

Juniper Networks hardware and software products are Year 2000 compliant. The Junos OS has no known time-related limitations through the year 2038. However, the NTP application is known to have some difficulty in the year 2036.

SOFTWARE LICENSE

The terms and conditions for using this software are described in the software license contained in the acknowledgment to your purchase order or, to the extent applicable, to any reseller agreement or end-user purchase agreement executed between you and Juniper Networks. By using this software, you indicate that you understand and agree to be bound by those terms and conditions.

Generally speaking, the software license restricts the manner in which you are permitted to use the software and may contain prohibitions against certain uses. The software license may state conditions under which the license is automatically terminated. You should consult the license for further details.

For complete product documentation, please see the Juniper Networks Web site at www.juniper.net/techpubs.

Copyright © 2010, Juniper Networks, Inc.

iii

END USER LICENSE AGREEMENT

READ THIS END USER LICENSE AGREEMENT (“AGREEMENT”) BEFORE DOWNLOADING, INSTALLING, OR USING THE SOFTWARE.

BY DOWNLOADING, INSTALLING, OR USING THE SOFTWARE OR OTHERWISE EXPRESSING YOUR AGREEMENT TO THE TERMS CONTAINED HEREIN, YOU (AS CUSTOMER OR IF YOU ARE NOT THE CUSTOMER, AS A REPRESENTATIVE/AGENT AUTHORIZED TO BINDTHECUSTOMER)CONSENTTOBEBOUNDBYTHISAGREEMENT. IFYOUDONOTORCANNOTAGREETOTHETERMSCONTAINED HEREIN, THEN (A) DO NOT DOWNLOAD, INSTALL, OR USE THE SOFTWARE, AND (B) YOU MAY CONTACT JUNIPER NETWORKS REGARDING LICENSE TERMS.

1.The Parties. The parties to this Agreement are (i) Juniper Networks, Inc. (if the Customer’s principal office is located in the Americas) or JuniperNetworks(Cayman)Limited(iftheCustomer’sprincipalofficeislocatedoutsidetheAmericas)(suchapplicableentitybeingreferred tohereinas“Juniper”),and(ii)thepersonororganizationthatoriginallypurchasedfromJuniperoranauthorizedJuniperresellertheapplicable license(s) for use of the Software (“Customer”) (collectively, the “Parties”).

2.The Software. In this Agreement, “Software” means the program modules and features of the Juniper or Juniper-supplied software, for which Customer has paid the applicable license or support fees to Juniper or an authorized Juniper reseller, or which was embedded by Juniper in equipment which Customer purchased from Juniper or an authorized Juniper reseller. “Software” also includes updates, upgrades and new releases of such software. “Embedded Software” means Software which Juniper has embedded in or loaded onto the Juniper equipment and any updates, upgrades, additions or replacements which are subsequently embedded in or loaded onto the equipment.

3.LicenseGrant. Subjecttopaymentoftheapplicablefeesandthelimitationsandrestrictionssetforthherein,JunipergrantstoCustomer a non-exclusive and non-transferable license, without right to sublicense, to use the Software, in executable form only, subject to the following use restrictions:

a.Customer shall use Embedded Software solely as embedded in, and for execution on, Juniper equipment originally purchased by Customer from Juniper or an authorized Juniper reseller.

b.Customer shall use the Software on a single hardware chassis having a single processing unit, or as many chassis or processing units for which Customer has paid the applicable license fees; provided, however, with respect to the Steel-Belted Radius or Odyssey Access Client software only, Customer shall use such Software on a single computer containing a single physical random access memory space and containing any number of processors. Use of the Steel-Belted Radius or IMS AAA software on multiple computers or virtual machines (e.g., Solaris zones) requires multiple licenses, regardless of whether such computers or virtualizations are physically contained on a single chassis.

c.Product purchase documents, paper or electronic user documentation, and/or the particular licenses purchased by Customer may specifylimitstoCustomer’suseoftheSoftware.Suchlimitsmayrestrictusetoamaximumnumberofseats,registeredendpoints,concurrent users, sessions, calls, connections, subscribers, clusters, nodes, realms, devices, links, ports or transactions, or require the purchase of separate licenses to use particular features, functionalities, services, applications, operations, or capabilities, or provide throughput, performance, configuration, bandwidth, interface, processing, temporal, or geographical limits. In addition, such limits may restrict the use of the Software to managing certain kinds of networks or require the Software to be used only in conjunction with other specific Software. Customer’s use of the Software shall be subject to all such limitations and purchase of all applicable licenses.

d.For any trial copy of the Software, Customer’s right to use the Software expires 30 days after download, installation or use of the Software. Customer may operate the Software after the 30-day trial period only if Customer pays for a license to do so. Customer may not extend or create an additional trial period by re-installing the Software after the 30-day trial period.

e.The Global Enterprise Edition of the Steel-Belted Radius software may be used by Customer only to manage access to Customer’s enterprise network. Specifically, service provider customers are expressly prohibited from using the Global Enterprise Edition of the Steel-Belted Radius software to support any commercial network access services.

The foregoing license is not transferable or assignable by Customer. No license is granted herein to any user who did not originally purchase the applicable license(s) for the Software from Juniper or an authorized Juniper reseller.

4. Use Prohibitions. Notwithstanding the foregoing, the license provided herein does not permit the Customer to, and Customer agrees not to and shall not: (a) modify, unbundle, reverse engineer, or create derivative works based on the Software; (b) make unauthorized copies of the Software (except as necessary for backup purposes); (c) rent, sell, transfer, or grant any rights in and to any copy of the Software,inanyform,toanythirdparty;(d)removeanyproprietarynotices,labels,ormarksonorinanycopyoftheSoftwareoranyproduct in which the Software is embedded; (e) distribute any copy of the Software to any third party, including as may be embedded in Juniper equipmentsoldinthesecondhandmarket;(f)useany‘locked’orkey-restrictedfeature,function,service,application,operation,orcapability without first purchasing the applicable license(s) and obtaining a valid key from Juniper, even if such feature, function, service, application, operation, or capability is enabled without a key; (g) distribute any key for the Software provided by Juniper to any third party; (h) use the

iv

Copyright © 2010, Juniper Networks, Inc.

Software in any manner that extends or is broader than the uses purchased by Customer from Juniper or an authorized Juniper reseller; (i) use Embedded Software on non-Juniper equipment; (j) use Embedded Software (or make it available for use) on Juniper equipment that the Customer did not originally purchase from Juniper or an authorized Juniper reseller; (k) disclose the results of testing or benchmarking of the Software to any third party without the prior written consent of Juniper; or (l) use the Software in any manner other than as expressly provided herein.

5.Audit. Customer shall maintain accurate records as necessary to verify compliance with this Agreement. Upon request by Juniper, Customer shall furnish such records to Juniper and certify its compliance with this Agreement.

6.Confidentiality. The Parties agree that aspects of the Software and associated documentation are the confidential property of Juniper. As such, Customer shall exercise all reasonable commercial efforts to maintain the Software and associated documentation in confidence, which at a minimum includes restricting access to the Software to Customer employees and contractors having a need to use the Software for Customer’s internal business purposes.

7.Ownership. Juniper and Juniper’s licensors, respectively, retain ownership of all right, title, and interest (including copyright) in and to the Software, associated documentation, and all copies of the Software. Nothing in this Agreement constitutes a transfer or conveyance of any right, title, or interest in the Software or associated documentation, or a sale of the Software, associated documentation, or copies of the Software.

8.Warranty, Limitation of Liability, Disclaimer of Warranty. The warranty applicable to the Software shall be as set forth in the warranty statementthataccompaniestheSoftware(the“WarrantyStatement”).NothinginthisAgreementshallgiverisetoanyobligationtosupport the Software. Support services may be purchased separately. Any such support shall be governed by a separate, written support services agreement. TO THE MAXIMUM EXTENT PERMITTED BY LAW, JUNIPER SHALL NOT BE LIABLE FOR ANY LOST PROFITS, LOSS OF DATA, ORCOSTSORPROCUREMENTOFSUBSTITUTEGOODSORSERVICES,ORFORANYSPECIAL,INDIRECT,ORCONSEQUENTIALDAMAGES ARISINGOUTOFTHISAGREEMENT,THESOFTWARE,ORANYJUNIPERORJUNIPER-SUPPLIEDSOFTWARE.INNOEVENTSHALLJUNIPER BE LIABLE FOR DAMAGES ARISING FROM UNAUTHORIZED OR IMPROPER USE OF ANY JUNIPER OR JUNIPER-SUPPLIED SOFTWARE. EXCEPT AS EXPRESSLY PROVIDED IN THE WARRANTY STATEMENT TO THE EXTENT PERMITTED BY LAW, JUNIPER DISCLAIMS ANY AND ALL WARRANTIES IN AND TO THE SOFTWARE (WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE), INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NONINFRINGEMENT. IN NO EVENT DOES JUNIPER WARRANT THAT THE SOFTWARE, OR ANY EQUIPMENT OR NETWORK RUNNING THE SOFTWARE, WILL OPERATE WITHOUT ERROR OR INTERRUPTION, OR WILL BE FREE OF VULNERABILITY TO INTRUSION OR ATTACK. In no event shall Juniper’s or its suppliers’ or licensors’ liability to Customer, whether in contract, tort (including negligence), breach of warranty, or otherwise, exceed the price paid by Customer for the Software that gave rise to the claim, or if the Software is embedded in another Juniper product, the price paid by Customer for such other product. Customer acknowledges and agrees that Juniper has set its prices and entered into this Agreement in reliance upon the disclaimers of warranty and the limitations of liability set forth herein, that the same reflect an allocation of risk between the Parties (including the risk that a contract remedy may fail of its essential purpose and cause consequential loss), and that the same form an essential basis of the bargain between the Parties.

9.Termination. Any breach of this Agreement or failure by Customer to pay any applicable fees due shall result in automatic termination of the license granted herein. Upon such termination, Customer shall destroy or return to Juniper all copies of the Software and related documentation in Customer’s possession or control.

10.Taxes. All license fees payable under this agreement are exclusive of tax. Customer shall be responsible for paying Taxes arising from the purchase of the license, or importation or use of the Software. If applicable, valid exemption documentation for each taxing jurisdiction shall be provided to Juniper prior to invoicing, and Customer shall promptly notify Juniper if their exemption is revoked or modified. All payments made by Customer shall be net of any applicable withholding tax. Customer will provide reasonable assistance to Juniper in connection with such withholding taxes by promptly: providing Juniper with valid tax receipts and other required documentation showing Customer’s payment of any withholding taxes; completing appropriate applications that would reduce the amount of withholding tax to be paid; and notifying and assisting Juniper in any audit or tax proceeding related to transactions hereunder. Customer shall comply with all applicable tax laws and regulations, and Customer will promptly pay or reimburse Juniper for all costs and damages related to any liability incurred by Juniper as a result of Customer’s non-compliance or delay with its responsibilities herein. Customer’s obligations under this Section shall survive termination or expiration of this Agreement.

11.Export. Customer agrees to comply with all applicable export laws and restrictions and regulations of any United States and any applicable foreign agency or authority, and not to export or re-export the Software or any direct product thereof in violation of any such restrictions, laws or regulations, or without all necessary approvals. Customer shall be liable for any such violations. The version of the Software supplied to Customer may contain encryption or other capabilities restricting Customer’s ability to export the Software without an export license.

Copyright © 2010, Juniper Networks, Inc.

v

12.Commercial Computer Software. The Software is “commercial computer software” and is provided with restricted rights. Use, duplication, or disclosure by the United States government is subject to restrictions set forth in this Agreement and as provided in DFARS 227.7201 through 227.7202-4, FAR 12.212, FAR 27.405(b)(2), FAR 52.227-19, or FAR 52.227-14(ALT III) as applicable.

13.Interface Information. To the extent required by applicable law, and at Customer's written request, Juniper shall provide Customer with the interface information needed to achieve interoperability between the Software and another independently created program, on payment of applicable fee, if any. Customer shall observe strict obligations of confidentiality with respect to such information and shall use such information in compliance with any applicable terms and conditions upon which Juniper makes such information available.

14.ThirdPartySoftware. Any licensor of Juniper whose software is embedded in the Software and any supplier of Juniper whose products or technology are embedded in (or services are accessed by) the Software shall be a third party beneficiary with respect to this Agreement, and such licensor or vendor shall have the right to enforce this Agreement in its own name as if it were Juniper. In addition, certain third party software may be provided with the Software and is subject to the accompanying license(s), if any, of its respective owner(s). To the extent portions of the Software are distributed under and subject to open source licenses obligating Juniper to make the source code for such portions publicly available (such as the GNU General Public License (“GPL”) or the GNU Library General Public License (“LGPL”)), Juniper will make such source code portions (including Juniper modifications, as appropriate) available upon request for a period of up to three years from the date of distribution. Such request can be made in writing to Juniper Networks, Inc., 1194 N. Mathilda Ave., Sunnyvale, CA 94089, ATTN: General Counsel. You may obtain a copy of the GPL at http://www.gnu.org/licenses/gpl.html, and a copy of the LGPL at http://www.gnu.org/licenses/lgpl.html .

15.Miscellaneous. This Agreement shall be governed by the laws of the State of California without reference to its conflicts of laws principles. The provisions of the U.N. Convention for the International Sale of Goods shall not apply to this Agreement. For any disputes arising under this Agreement, the Parties hereby consent to the personal and exclusive jurisdiction of, and venue in, the state and federal courts within Santa Clara County, California. This Agreement constitutes the entire and sole agreement between Juniper and the Customer with respect to the Software, and supersedes all prior and contemporaneous agreements relating to the Software, whether oral or written (including any inconsistent terms contained in a purchase order), except that the terms of a separate written agreement executed by an authorized Juniper representative and Customer shall govern to the extent such terms are inconsistent or conflict with terms contained herein. No modification to this Agreement nor any waiver of any rights hereunder shall be effective unless expressly assented to in writing by the party to be charged. If any portion of this Agreement is held invalid, the Parties agree that such invalidity shall not affect the validity of the remainder of this Agreement. This Agreement and associated documentation has been written in the English language, and the Parties agree that the English version will govern. (For Canada: Les parties aux présentés confirment leur volonté que cette convention de même que tous les documents y compris tout avis qui s'y rattaché, soient redigés en langue anglaise. (Translation: The parties confirm that this Agreement and all related documentation is and will be in the English language)).

vi

Copyright © 2010, Juniper Networks, Inc.

Table of Contents

About This Topic Collection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix

How to Use This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xix

List of EX Series Guides for Junos OS Release 10.3 . . . . . . . . . . . . . . . . . . . . . . . . xix

Downloading Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxi

Documentation Symbols Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxii

Documentation Feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiii

Requesting Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiv

Self-Help Online Tools and Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiv

Opening a Case with JTAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiv

Part 1

Switch and Components Overview and Specifications

 

Chapter 1

EX3200 and EX4200 Switches Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 3

 

EX3200 and EX4200 Switches Hardware Overview . . . . . . . . . . . . . . . . . . . . . . .

. 3

 

EX3200 and EX4200 Switch Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 3

 

EX3200 Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 4

 

EX4200 Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 4

 

Uplink Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 5

 

Power over Ethernet (PoE) Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 5

 

EX3200 Switch Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 6

 

EX4200 Switch Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 6

 

Chassis Physical Specifications for EX3200 and EX4200 Switches . . . . . . . . . . .

. 7

 

Front Panel of an EX3200 Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 7

 

Rear Panel of an EX3200 Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 8

 

Front Panel of an EX4200 Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 9

 

Rear Panel of an EX4200 Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 11

Chapter 2

Component Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

 

LCD Panel in EX3200 and EX4200 Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

 

LCD Panel Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

 

LCD Panel Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

 

Field-Replaceable Units in EX3200 and EX4200 Switches . . . . . . . . . . . . . . . . . .

18

 

Chassis Status LEDs in EX3200 Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

 

Chassis Status LEDs in EX4200 Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20

 

Network Port LEDs in EX3200 and EX4200 Switches . . . . . . . . . . . . . . . . . . . . . .

21

 

Management Port LEDs in EX3200 and EX4200 Switches . . . . . . . . . . . . . . . . . .

25

 

Power Supply in EX3200 and EX4200 Switches . . . . . . . . . . . . . . . . . . . . . . . . . .

27

 

AC Power Supply LEDs in EX3200 and EX4200 Switches . . . . . . . . . . . . . . . . . .

30

 

DC Power Supply LEDs in EX3200 and EX4200 Switches . . . . . . . . . . . . . . . . . .

30

 

Cooling System and Airflow in an EX3200 Switch . . . . . . . . . . . . . . . . . . . . . . . . .

31

Copyright © 2010, Juniper Networks, Inc.

vii

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

 

Cooling System and Airflow in an EX4200 Switch . . . . . . . . . . . . . . . . . . . . . . . .

. 33

 

Uplink Modules in EX3200 and EX4200 Switches . . . . . . . . . . . . . . . . . . . . . . . . .

34

 

SFP Uplink Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

35

 

SFP+ Uplink Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

35

 

XFP Uplink Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

37

Chapter 3

Component Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

39

 

USB Port Specifications for an EX Series Switch . . . . . . . . . . . . . . . . . . . . . . . . . .

39

 

Network Port Connector Pinout Information for an EX3200 or EX4200

 

 

Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

40

 

Console Port Connector Pinout Information for an EX Series Switch . . . . . . . . . . .

41

 

Management Port Connector Pinout Information for an EX3200 or EX4200

 

 

Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

42

 

Optical Interface Support in EX3200 and EX4200 Switches . . . . . . . . . . . . . . . .

43

 

SFP+ Direct Attach Cables for EX Series Switches . . . . . . . . . . . . . . . . . . . . . . . .

69

 

Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

70

 

Standards Supported by These Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

73

 

Uplink Modules Connector Pinout Information for EX3200 and EX4200

 

 

Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

73

 

Virtual Chassis Ports Connector Pinout Information for EX4200 Switches . . . . . .

81

Part 2

Planning for Switch Installation

 

Chapter 4

Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

87

 

Site Preparation Checklist for EX3200 and EX4200 Switches . . . . . . . . . . . . . . .

87

 

General Site Guidelines for EX Series Switches . . . . . . . . . . . . . . . . . . . . . . . . . . .

89

 

Site Electrical Wiring Guidelines for EX Series Switches . . . . . . . . . . . . . . . . . . . .

89

 

Environmental Requirements and Specifications for EX Series Switches . . . . . .

90

Chapter 5

Mounting and Clearance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

93

 

Rack Requirements for EX3200 and EX4200 Switches . . . . . . . . . . . . . . . . . . . .

93

 

Cabinet Requirements for EX3200 and EX4200 Switches . . . . . . . . . . . . . . . . . .

94

 

Requirements for Mounting an EX3200 or EX4200 Switch on a Desktop or

 

 

Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

95

 

Clearance Requirements for Airflow and Hardware Maintenance for EX3200

 

 

and EX4200 Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

96

Chapter 6

Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

99

 

Network Cable Specifications for EX3200 and EX4200 Switches . . . . . . . . . . . .

99

Chapter 7

Planning Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

101

 

Power Specifications for EX3200 and EX4200 Switches . . . . . . . . . . . . . . . . . . .

101

 

AC Power Cord Specifications for EX3200 and EX4200 Switches . . . . . . . . . . .

102

viii

Copyright © 2010, Juniper Networks, Inc.

Table of Contents

Chapter 8

Planning the Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

105

 

Understanding Virtual Chassis Hardware Configuration on an EX4200

 

 

Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

105

 

Planning the Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

106

 

Virtual Chassis Cabling Configuration Examples for EX4200 Switches . . . . . . . .

107

 

Adding a New Switch to an Existing Virtual Chassis Configuration (CLI

 

 

Procedure) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

109

 

Adding a New Switch to an Existing Virtual Chassis Configuration Within

 

 

the Same Wiring Closet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

109

 

Adding a New Switch from a Different Wiring Closet to an Existing Virtual

 

 

Chassis Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

110

 

Adding a New Switch to an Existing Preprovisioned Virtual Chassis

 

 

Configuration Using Autoprovisioning . . . . . . . . . . . . . . . . . . . . . . . . . . .

112

Part 3

Installing and Connecting the Switch and Switch Components

Chapter 9

Installing the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

117

 

Installing and Connecting an EX3200 or EX4200 Switch . . . . . . . . . . . . . . . . . .

. 117

 

Unpacking an EX3200 or EX4200 Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

118

 

Mounting an EX3200 or EX4200 Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

120

 

Mounting an EX3200 or EX4200 Switch on a Desk or Other Level Surface . . . . .

121

 

Mounting an EX3200 or EX4200 Switch on Two Posts in a Rack or Cabinet . . .

122

 

Mounting an EX3200 or EX4200 Switch on Four Posts in a Rack or Cabinet . . .

124

 

Mounting an EX3200 or EX4200 Switch in a Recessed Position in a Rack or

 

 

Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

128

 

Mounting an EX3200 or EX4200 Switch on a Wall . . . . . . . . . . . . . . . . . . . . . . .

128

Chapter 10

Installing Switch Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

131

 

Installing and Removing EX3200 and EX4200 Switch Hardware

 

 

Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

131

 

Installing a Power Supply in an EX3200 or EX4200 Switch . . . . . . . . . . . . . . . . .

132

 

Installing a Fan Tray in an EX3200 or EX4200 Switch . . . . . . . . . . . . . . . . . . . . .

133

 

Installing an Uplink Module in an EX3200 or EX4200 Switch . . . . . . . . . . . . . . .

135

 

Installing a Transceiver in an EX Series Switch . . . . . . . . . . . . . . . . . . . . . . . . . . .

137

 

Connecting a Virtual Chassis Cable to an EX4200 Switch . . . . . . . . . . . . . . . . . .

139

Chapter 11

Connecting the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

141

 

Connecting Earth Ground to an EX Series Switch . . . . . . . . . . . . . . . . . . . . . . . . .

141

 

Connecting Earth Ground to an EX2200 or EX3200 Switch . . . . . . . . . . . . .

142

 

Connecting Earth Ground to an EX4200 Switch . . . . . . . . . . . . . . . . . . . . . .

143

 

Connecting Earth Ground to an EX4500 Switch . . . . . . . . . . . . . . . . . . . . . .

144

 

Connecting Earth Ground to an EX8208 Switch . . . . . . . . . . . . . . . . . . . . . .

145

 

Connecting Earth Ground to an EX8216 Switch . . . . . . . . . . . . . . . . . . . . . . .

146

 

Connecting AC Power to an EX3200 or EX4200 Switch . . . . . . . . . . . . . . . . . . . .

147

 

Connecting DC Power to an EX3200 or EX4200 Switch . . . . . . . . . . . . . . . . . . .

149

 

Connecting an EX Series Switch to a Network for Out-of-Band Management . .

152

 

Connecting an EX Series Switch to a Management Console . . . . . . . . . . . . . . . .

153

 

Connecting an EX Series Switch to a Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . .

155

 

Setting the Serial Console Speed for the Switch . . . . . . . . . . . . . . . . . . . . . .

155

 

Configuring the Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

156

Copyright © 2010, Juniper Networks, Inc.

ix

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

 

Connecting the Modem to the Console Port . . . . . . . . . . . . . . . . . . . . . . . . .

. 157

 

Connecting a Fiber-Optic Cable to an EX Series Switch . . . . . . . . . . . . . . . . . . . .

158

Chapter 12

Performing Initial Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

161

 

EX3200 and EX4200 Default Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

161

 

Connecting and Configuring an EX Series Switch (CLI Procedure) . . . . . . . . . . .

165

 

Connecting and Configuring an EX Series Switch (J-Web Procedure) . . . . . . . . .

167

Part 4

Removing Switch Components

 

Chapter 13

Removing Switch Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

173

 

Installing and Removing EX3200 and EX4200 Switch Hardware

 

 

Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

173

 

Removing a Power Supply from an EX3200 or EX4200 Switch . . . . . . . . . . . . . .

174

 

Removing a Fan Tray from an EX3200 or EX4200 Switch . . . . . . . . . . . . . . . . . .

176

 

Removing an Uplink Module from an EX3200 or EX4200 Switch . . . . . . . . . . . .

177

 

Removing a Transceiver from an EX Series Switch . . . . . . . . . . . . . . . . . . . . . . . .

179

 

Disconnecting a Fiber-Optic Cable from an EX Series Switch . . . . . . . . . . . . . . . .

181

 

Disconnecting a Virtual Chassis Cable from an EX4200 Switch . . . . . . . . . . . . .

182

 

Replacing a Member Switch of a Virtual Chassis Configuration (CLI

 

 

Procedure) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

183

 

Remove, Repair, and Reinstall the Same Switch . . . . . . . . . . . . . . . . . . . . . .

184

 

Remove a Member Switch, Replace with a Different Switch, and Reapply

 

 

the Old Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

184

 

Remove a Member Switch and Make Its Member ID Available for

 

 

Reassignment to a Different Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . .

185

Part 5

Switch and Component Maintenance

 

Chapter 14

Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

189

 

Maintaining Fiber-Optic Cables in EX Series Switches . . . . . . . . . . . . . . . . . . . . .

189

Part 6

Troubleshooting Switch Components

 

Chapter 15

Troubleshooting Switch Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

193

 

Troubleshooting Network Interfaces on EX3200 and EX4200 Switches . . . . . .

193

 

The interface on one of the last four built-in network ports in an EX3200

 

 

switch (for example, interface ge-0/0/23) is down . . . . . . . . . . . . . . . .

193

 

The interface on the port in which an SFP or SFP+ transceiver is installed

 

 

in an SFP+ uplink module is down . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

194

 

Troubleshooting Uplink Module Installation or Replacement on EX3200 and

 

 

EX4200 Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

194

 

Virtual Chassis port (VCP) connection does not work . . . . . . . . . . . . . . . . .

194

 

One of the last four network ports on an EX3200 switch with an SFP or

 

 

SFP+ uplink module installed is disabled . . . . . . . . . . . . . . . . . . . . . . . .

195

x

Copyright © 2010, Juniper Networks, Inc.

Table of Contents

Part 7

Returning Hardware

 

Chapter 16

Returning the Switch or Switch Components . . . . . . . . . . . . . . . . . . . . . . . .

199

 

Returning an EX3200 or EX4200 Switch or Component for Repair or

 

 

Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

199

 

Locating the Serial Number on an EX3200 or EX4200 Switch or Component . .

200

 

Listing the Switch and Components Details with the CLI . . . . . . . . . . . . . .

200

 

Locating the Chassis Serial Number ID Label on an EX3200 or EX4200

 

 

Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

200

 

Locating the Serial Number ID Labels on FRUs in an EX3200 or EX4200

 

 

Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

201

 

Contacting Customer Support to Obtain Return Materials Authorization for EX

 

 

Series Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

201

 

Packing an EX3200 or EX4200 Switch or Component for Shipping . . . . . . . . . .

202

 

Packing an EX3200 or EX4200 Switch for Shipping . . . . . . . . . . . . . . . . . .

203

 

Packing EX3200 or EX4200 Switch Components for Shipping . . . . . . . . . .

204

Part 8

Safety Information

 

Chapter 17

General Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

207

 

General Safety Guidelines and Warnings for EX Series Switches . . . . . . . . . . . .

207

 

Definitions of Safety Warning Levels for EX Series Switches . . . . . . . . . . . . . . . .

208

 

Fire Safety Requirements for EX Series Switches . . . . . . . . . . . . . . . . . . . . . . . . .

210

 

Qualified Personnel Warning for EX Series Switches . . . . . . . . . . . . . . . . . . . . . .

. 211

 

Warning Statement for Norway and Sweden for EX Series Switches . . . . . . . . . .

212

Chapter 18

Radiation and Laser Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

213

 

Laser and LED Safety Guidelines and Warnings for EX Series Switches . . . . . . .

213

 

General Laser Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

213

 

Class 1 Laser Product Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

213

 

Class 1 LED Product Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

214

 

Laser Beam Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

214

 

Radiation from Open Port Apertures Warning for EX Series Switches . . . . . . . . .

216

Chapter 19

Installation and Maintenance Safety Information . . . . . . . . . . . . . . . . . . . .

219

 

Installation Instructions Warning for EX Series Switches . . . . . . . . . . . . . . . . . . .

219

 

Chassis Lifting Guidelines for EX3200 and EX4200 Switches . . . . . . . . . . . . . .

220

 

Ramp Warning for EX Series Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

220

 

Rack-Mounting and Cabinet-Mounting Warnings for EX Series Switches . . . . . .

221

 

Wall-Mounting Warning for EX3200 and EX4200 Switches . . . . . . . . . . . . . . . .

225

 

Grounded Equipment Warning for EX Series Switches . . . . . . . . . . . . . . . . . . . .

226

 

Maintenance and Operational Safety Guidelines and Warnings for EX Series

 

 

Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

226

 

Battery Handling Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

227

 

Jewelry Removal Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

228

 

Lightning Activity Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

229

 

Operating Temperature Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

230

 

Product Disposal Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

232

Copyright © 2010, Juniper Networks, Inc.

xi

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

Chapter 20

Power and Electrical Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . .

235

 

General Electrical Safety Guidelines and Warnings for EX Series Switches . . . .

235

 

Prevention of Electrostatic Discharge Damage on EX Series Switches . . . . . . . .

236

 

AC Power Electrical Safety Guidelines for EX Series Switches . . . . . . . . . . . . . .

238

 

AC Power Disconnection Warning for EX Series Switches . . . . . . . . . . . . . . . . . .

239

 

Multiple Power Supplies Disconnection Warning for EX Series Switches . . . . . .

240

 

Power Sources for Redundant Power Supplies Warning for EX4200

 

 

Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

240

 

DC Power Electrical Safety Guidelines for EX Series Switches . . . . . . . . . . . . . .

240

 

DC Power Disconnection Warning for EX Series Switches . . . . . . . . . . . . . . . . . .

242

 

DC Power Grounding Requirements and Warning for EX Series Switches . . . . .

243

 

DC Power Wiring Sequence Warning for EX Series Switches . . . . . . . . . . . . . . . .

244

 

DC Power Wiring Terminations Warning for EX Series Switches . . . . . . . . . . . . .

246

 

TN Power Warning for EX Series Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

247

 

In Case of Electrical Accident: Action to Take on an EX Series Switch . . . . . . . .

248

Part 9

Compliance Information

 

Chapter 21

Compliance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

251

 

Agency Approvals for EX Series Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

251

 

Compliance Statements for EMC Requirements for EX Series Switches . . . . . .

252

 

Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

252

 

European Community . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

253

 

Japan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

253

 

United States . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

253

 

FCC Part 15 Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

253

 

Non-Regulatory Environmental Standards . . . . . . . . . . . . . . . . . . . . . . . . . .

254

 

Compliance Statements for Acoustic Noise for EX Series Switches . . . . . . . . . .

254

 

Declaration of Conformity for EX3200 and EX4200 Switches . . . . . . . . . . . . . .

255

xii

Copyright © 2010, Juniper Networks, Inc.

List of Figures

Part 1

Switch and Components Overview and Specifications

 

Chapter 1

EX3200 and EX4200 Switches Overview . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . 3

 

Figure 1: EX3200 Switch with 48 Gigabit Ethernet Ports . . . . . . . . . . . . . . . . . . . .

. 8

 

Figure 2: EX3200 Switch with 24 Gigabit Ethernet Ports . . . . . . . . . . . . . . . . . . . .

. 8

 

Figure 3: EX3200 Switch Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 9

 

Figure 4: EX4200 Switch with 48 Gigabit Ethernet Ports . . . . . . . . . . . . . . . . . . . .

10

 

Figure 5: EX4200 Switch with 24 Gigabit Ethernet Ports . . . . . . . . . . . . . . . . . . . .

10

 

Figure 6: EX4200-24F Switch with 24 SFP Ports . . . . . . . . . . . . . . . . . . . . . . . . . .

10

 

Figure 7: EX4200 Switch Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 11

Chapter 2

Component Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

 

Figure 8: LCD Panel in EX3200 and EX4200 Switches . . . . . . . . . . . . . . . . . . . . . .

13

 

Figure 9: Chassis Status LEDs in an EX3200 Switch . . . . . . . . . . . . . . . . . . . . . . . .

19

 

Figure 10: Chassis Status LEDs in an EX4200 Switch . . . . . . . . . . . . . . . . . . . . . .

20

 

Figure 11: LEDs on the Network Ports on the Front Panel . . . . . . . . . . . . . . . . . . .

. 21

 

Figure 12: LEDs on the Uplink Module Ports on the SFP Uplink Module . . . . . . . .

. 21

 

Figure 13: LEDs on the Uplink Module Ports on the SFP+ Uplink Module . . . . . . .

22

 

Figure 14: LEDs on the Uplink Module Ports on the XFP Uplink Module . . . . . . . . .

22

 

Figure 15: LEDs on the Management Port on an EX3200 Switch . . . . . . . . . . . . . .

26

 

Figure 16: LEDs on the Management Port on an EX4200 Switch . . . . . . . . . . . . .

26

 

Figure 17: 320 W AC Power Supply in EX3200 and EX4200 Switches . . . . . . . . .

28

 

Figure 18: 600 W and 930 W AC Power Supplies in EX3200 and EX4200

 

 

Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

28

 

Figure 19: DC Power Supply in EX3200 and EX4200 Switches . . . . . . . . . . . . . . .

28

 

Figure 20: Fan Tray Used in an EX3200 Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . .

32

 

Figure 21: Airflow Through the EX3200 Switch Chassis . . . . . . . . . . . . . . . . . . . . .

32

 

Figure 22: Fan Tray Used in an EX4200 Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . .

33

 

Figure 23: Airflow Through the EX4200 Switch Chassis . . . . . . . . . . . . . . . . . . . . .

33

 

Figure 24: SFP Uplink Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

35

 

Figure 25: SFP+ Uplink Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

36

 

Figure 26: XFP Uplink Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

37

Part 2

Planning for Switch Installation

 

Chapter 5

Mounting and Clearance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

93

 

Figure 27: Clearance Requirements for Airflow and Hardware Maintenance for

 

 

EX3200 and EX4200 Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

96

 

Figure 28: Airflow Through the EX3200 Switch Chassis . . . . . . . . . . . . . . . . . . . . .

97

 

Figure 29: Airflow Through the EX4200 Switch Chassis . . . . . . . . . . . . . . . . . . . .

98

Chapter 7

Planning Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

101

Copyright © 2010, Juniper Networks, Inc.

xiii

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

 

Figure 30: AC Plug Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

103

Chapter 8

Planning the Virtual Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

105

 

Figure 31: EX4200 Switches Mounted on a Single Rack and Connected in a Ring

 

 

Topology Using Short and Long Cables: Option 1 . . . . . . . . . . . . . . . . . . . . . .

107

 

Figure 32: EX4200 Switches Mounted on a Single Rack and Connected in a Ring

 

 

Topology Using Short and Long Cables: Option 2 . . . . . . . . . . . . . . . . . . . . .

108

 

Figure 33: EX4200 Switches Mounted on a Single Rack and Connected in a Ring

 

 

Topology Using Short and Medium Cables . . . . . . . . . . . . . . . . . . . . . . . . . .

108

 

Figure 34: EX4200 Switches Mounted on Adjacent Racks and Connected in a

 

 

Ring Topology Using Medium and Long Cables: Option 1 . . . . . . . . . . . . . . .

108

 

Figure 35: EX4200 Switches Mounted on Adjacent Racks and Connected in a

 

 

Ring Topology Using Medium and Long Cables: Option 2 . . . . . . . . . . . . . . .

109

Part 3

Installing and Connecting the Switch and Switch Components

Chapter 9

Installing the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

117

 

Figure 36: Unpacking an EX3200 or EX4200 Switch . . . . . . . . . . . . . . . . . . . . . . .

119

 

Figure 37: Attaching Rubber Feet to an EX3200 or EX4200 Switch Chassis . . . .

121

 

Figure 38: Attaching the Mounting Bracket Along the Front of the Switch . . . . . .

123

 

Figure 39: Mounting the Switch on Two Posts in a Rack . . . . . . . . . . . . . . . . . . . .

124

 

Figure 40: Attaching the Front Bracket to the Side-Rail Bracket . . . . . . . . . . . . .

126

 

Figure 41: Attaching the Side-Rail Bracket to the Switch Chassis . . . . . . . . . . . . .

126

 

Figure 42: Mounting the Switch to the Front Posts in a Rack . . . . . . . . . . . . . . . .

127

 

Figure 43: Sliding the Rear Brackets to the Rear of a Four-Post Rack . . . . . . . . . .

127

 

Figure 44: Attaching Wall-Mount Brackets to an EX3200 or EX4200 Switch

 

 

Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

129

 

Figure 45: Mounting an EX3200 or EX4200 Switch on a Wall . . . . . . . . . . . . . . .

130

Chapter 10

Installing Switch Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

131

 

Figure 46: Installing a Power Supply in an EX3200 or EX4200 Switch . . . . . . . .

133

 

Figure 47: Installing a Fan Tray in an EX3200 Switch . . . . . . . . . . . . . . . . . . . . . .

134

 

Figure 48: Installing a Fan Tray in an EX4200 Switch . . . . . . . . . . . . . . . . . . . . . .

134

 

Figure 49: Installing an Uplink Module in an EX3200 or EX4200 Switch . . . . . . .

136

 

Figure 50: Installing a Transceiver in an EX Series Switch . . . . . . . . . . . . . . . . . . .

138

 

Figure 51: Connecting a Virtual Chassis Cable to an EX4200 Switch . . . . . . . . . .

140

Chapter 11

Connecting the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

141

 

Figure 52: Connecting a Grounding Cable to an EX Series Switch . . . . . . . . . . . . .

141

 

Figure 53: Connecting the Grounding Lug to an EX4200 Switch on a Four-Post

 

 

Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

144

 

Figure 54: Connecting the AC Power Cord Retainer Clip to an AC Power Supply

 

 

in an EX3200 or EX4200 Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

148

 

Figure 55: Connecting an AC Power Cord to an AC Power Supply in an EX3200

 

 

or EX4200 Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

148

 

Figure 56: DC Power Supply in an EX3200 or EX4200 Switch . . . . . . . . . . . . . . .

149

 

Figure 57: Removing the Terminal Block Cover from a DC Power Supply in an

 

 

EX3200 or EX4200 Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

150

 

Figure 58: Securing Ring Lugs to the Terminals on the DC Power Supply in an

 

 

EX3200 or EX4200 Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

151

xiv

Copyright © 2010, Juniper Networks, Inc.

List of Figures

 

Figure 59: Ethernet Cable Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

152

 

Figure 60: Connecting an EX Series Switch to a Network for Out-of-Band

 

 

Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

153

 

Figure 61: Ethernet Cable Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

153

 

Figure 62: Connecting an EX Series Switch to a Management Console Through

 

 

a Console Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

154

 

Figure 63: Connecting an EX Series Switch Directly to a Management

 

 

Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

154

 

Figure 64: Ethernet Cable Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

157

 

Figure 65: Connecting a Fiber-Optic Cable to an Optical Transceiver Installed in

 

 

an EX Series Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

159

Chapter 12

Performing Initial Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

161

 

Figure 66: LCD Panel in an EX3200, EX4200, EX4500, or EX8200 Switch . . . .

168

Part 4

Removing Switch Components

 

Chapter 13

Removing Switch Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

173

 

Figure 67: Removing a Power Supply from an EX3200 or EX4200 Switch . . . . .

175

 

Figure 68: Removing a Fan Tray from an EX3200 Switch . . . . . . . . . . . . . . . . . . .

176

 

Figure 69: Removing a Fan Tray from an EX4200 Switch . . . . . . . . . . . . . . . . . .

. 177

 

Figure 70: Sliding the Screwdriver to the Narrow Part of the Keyhole . . . . . . . . .

179

 

Figure 71: Removing an Uplink Module from an EX3200 or EX4200 Switch . . . .

179

 

Figure 72: Removing a Transceiver from an EX Series Switch . . . . . . . . . . . . . . .

. 181

 

Figure 73: Virtual Chassis Cable Connector in an EX4200 Switch . . . . . . . . . . . .

183

Part 7

Returning Hardware

 

Chapter 16

Returning the Switch or Switch Components . . . . . . . . . . . . . . . . . . . . . . . .

199

 

Figure 74: Location of the Serial Number ID Label on an EX3200 Switch . . . . .

200

 

Figure 75: Location of the Serial Number ID Label on an EX4200 Switch . . . . . .

201

Part 8

Safety Information

 

Chapter 20

Power and Electrical Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . .

235

 

Figure 76: Place a Component into an Antistatic Bag . . . . . . . . . . . . . . . . . . . . . .

237

Copyright © 2010, Juniper Networks, Inc.

xv

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

xvi

Copyright © 2010, Juniper Networks, Inc.

List of Tables

 

Part 1

Switch and Components Overview and Specifications

 

Chapter 1

EX3200 and EX4200 Switches Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 3

 

Table 1: EX3200 Switch Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 6

 

Table 2: EX4200 Switch Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 6

 

Table 3: Physical Specifications of the EX3200 and EX4200 Switch Chassis . . .

. 7

Chapter 2

Component Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

 

Table 4: LCD Panel Menu Options in EX3200 and EX4200 Switches . . . . . . . . . .

15

 

Table 5: Chassis Status LEDs in an EX3200 Switch . . . . . . . . . . . . . . . . . . . . . . . .

19

 

Table 6: Chassis Status LEDs in an EX4200 Switch . . . . . . . . . . . . . . . . . . . . . . . .

20

 

Table 7: Link/Activity LED on Network Ports in EX3200 and EX4200

 

 

Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

22

 

Table 8: Status LED on Network Ports in EX3200 and EX4200 Switches . . . . . .

24

 

Table 9: Link/Activity LED on the Management Port on EX3200 and EX4200

 

 

Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

26

 

Table 10: Status LED on the Management Port on EX3200 and EX4200

 

 

Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

26

 

Table 11: Minimum Power Requirements for an EX3200 Switch . . . . . . . . . . . . . .

28

 

Table 12: Minimum Power Requirements for an EX4200 Switch . . . . . . . . . . . . . .

29

 

Table 13: AC Power Supply LEDs in EX3200 and EX4200 Switches . . . . . . . . . . .

30

 

Table 14: DC Power Supply LEDs in EX3200 and EX4200 Switches . . . . . . . . . . .

31

Chapter 3

Component Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

39

 

Table 15: Network Port Connector Pinout Information for an EX3200 or EX4200

 

 

Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

40

 

Table 16: EX Series Switches Console Port Connector Pinout Information . . . . . .

41

 

Table 17: Management Port Connector Pinout Information for EX3200 and

 

 

EX4200 Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

42

 

Table 18: Optical Interface Support and Copper Interface Support for Gigabit

 

 

Ethernet SFP Transceivers in EX3200 and EX4200 Switches . . . . . . . . . . . .

44

 

Table19:OpticalInterfaceSupportforFastEthernetSFPTransceiversinEX3200

 

 

and EX4200 Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

55

 

Table 20: Optical Interface Support for Gigabit Ethernet SFP+ Transceivers in

 

 

EX3200 and EX4200 Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

61

 

Table 21: Optical Interface Support for Gigabit Ethernet XFP Transceivers in

 

 

EX3200 and EX4200 Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

66

 

Table 22: SFP+ Direct Attach Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . .

71

 

Table23:UplinkModulesConnectorPinoutInformationforEX3200andEX4200

 

 

Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

73

 

Table 24: Virtual Chassis Ports (VCPs) Connector Pinout Information . . . . . . . . .

81

Copyright © 2010, Juniper Networks, Inc.

xvii

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

Part 2

Planning for Switch Installation

 

Chapter 4

Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 87

 

Table 25: Site Preparation Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 87

 

Table 26: Site Electrical Wiring Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

90

 

Table 27: EX Series Switch Environmental Tolerances . . . . . . . . . . . . . . . . . . . . .

. 91

Chapter 5

Mounting and Clearance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

93

 

Table 28: Rack Requirements and Specifications for the Switch . . . . . . . . . . . . .

93

 

Table 29: Cabinet Requirements and Specifications for the Switch . . . . . . . . . . .

95

Chapter 7

Planning Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

101

 

Table 30: AC Power Supply Electrical Specifications for EX3200 and EX4200

 

 

Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

101

 

Table 31: DC Power Supply Electrical Specifications for EX3200 and EX4200

 

 

Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

101

 

Table 32: AC Power Cord Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

102

Part 3

Installing and Connecting the Switch and Switch Components

Chapter 9

Installing the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

117

 

Table 33: Inventory of Components Provided with an EX3200 or EX4200

 

 

Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

119

Chapter 11

Connecting the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

141

 

Table 34: Port Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

156

xviii

Copyright © 2010, Juniper Networks, Inc.

About This Topic Collection

How to Use This Guide on page xix

List of EX Series Guides for Junos OS Release 10.3 on page xix

Downloading Software on page xxi

Documentation Symbols Key on page xxii

Documentation Feedback on page xxiii

Requesting Technical Support on page xxiv

How to Use This Guide

Complete documentation for the EX Series product family is provided on webpages at http://www.juniper.net/techpubs/en_US/release-independent/information-products/ pathway-pages/ex-series/product/index.html. We have selected content from these webpages and created a number of EX Series guides that collect related topics into a book-like format so that the information is easy to print and easy to download to your local computer.

Thisguide,CompleteHardwareGuideforEX3200andEX4200Switches,collectstogether informationabouttheEX3200fixed-configurationandEX4200virtual-chassisswitches. The release notes are at http://www.juniper.net/techpubs/en_US/junos10.3/information-products/topic-collections/ release-notes/10.3/junos-release-notes-10.3.pdf.

List of EX Series Guides for Junos OS Release 10.3

Title

Description

Complete Hardware Guide for EX2200 Switches

Componentdescriptions,sitepreparation,installation,

 

replacement, and safety and compliance information

 

for EX2200 switches

Complete Hardware Guide for EX3200 and EX4200 Switches

Componentdescriptions,sitepreparation,installation,

 

replacement, and safety and compliance information

 

for EX3200 and EX4200 switches

Complete Hardware Guide for EX4500 Switches

Componentdescriptions,sitepreparation,installation,

 

replacement, and safety and compliance information

 

for EX4500 switches

Copyright © 2010, Juniper Networks, Inc.

xix

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

Title

Description

Complete Hardware Guide for EX8208 Switches

Componentdescriptions,sitepreparation,installation,

 

replacement, and safety and compliance information

 

for EX8208 switches

Complete Hardware Guide for EX8216 Switches

Componentdescriptions,sitepreparation,installation,

 

replacement, and safety and compliance information

 

for EX8216 switches

Complete Software Guide for Junos® OS for EX Series Switches, Release 10.3

Software Topic Collections

JUNOS® OS for EX Series Switches, Release 10.3: Access Control

JUNOS® OS for EX Series Switches, Release 10.3: Configuration Management

JUNOS® OS for EX Series Switches, Release 10.3: Class of Service

JUNOS® OS for EX Series Switches, Release 10.3: Device Security

JUNOS® OS for EX Series Switches, Release 10.3: Ethernet Switching

JUNOS® OS for EX Series Switches, Release 10.3: Interfaces

JUNOS® OS for EX Series Switches, Release 10.3: Layer 3 Protocols

JUNOS® OS for EX Series Switches, Release 10.3: MPLS

JUNOS® OS for EX Series Switches, Release 10.3: Multicast

JUNOS® OS for EX Series Switches, Release 10.3: Network Management and Monitoring

JUNOS® OS for EX Series Switches, Release 10.3: Port Security

JUNOS® OS for EX Series Switches, Release 10.3: Power Management

JUNOS® OS for EX Series Switches, Release 10.3: Routing Policy and Packet Filtering

Softwarefeaturedescriptions,configurationexamples, and tasks for Junos OS for EX Series switches

Softwarefeaturedescriptions,configurationexamples and tasks, and reference pages for configuration statements and operational commands (This information also appears in the Complete Software Guide for Junos® OS for EX Series Switches, Release 10.3.)

JUNOS® OS for EX Series Switches, Release 10.3: Software Installation

xx

Copyright © 2010, Juniper Networks, Inc.

About This Topic Collection

Title

Description

JUNOS® OSforEXSeriesSwitches,Release10.3:Spanning-TreeProtocols

JUNOS® OS for EX Series Switches, Release 10.3: System Monitoring

JUNOS® OS for EX Series Switches, Release 10.3: System Services

JUNOS® OS for EX Series Switches, Release 10.3: System Setup

JUNOS® OS for EX Series Switches, Release 10.3: User and Access

Management

JUNOS® OS for EX Series Switches, Release 10.3: User Interfaces

JUNOS® OS for EX Series Switches, Release 10.3: Virtual Chassis

Downloading Software

You can download Junos OS for EX Series switches from the Download Software area at http://www.juniper.net/customers/support/ . To download the software, you must have a Juniper Networks user account. For information about obtaining an account, see http://www.juniper.net/entitlement/setupAccountInfo.do.

Copyright © 2010, Juniper Networks, Inc.

xxi

Juniper Networks EX4200, EX3200 User Manual

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

Documentation Symbols Key

Notice Icons

 

 

Icon

Meaning

Description

 

Informational note

Indicates important features or instructions.

 

Caution

Indicates a situation that might result in loss of data or hardware

 

 

damage.

 

Warning

Alerts you to the risk of personal injury or death.

 

Laser warning

Alerts you to the risk of personal injury from a laser.

Text and Syntax Conventions

 

 

Convention

Description

Bold text like this

Represents text that you type.

Fixed-width text like this

Represents output that appears on the

 

terminal screen.

Italic text like this

Introduces important new terms.

 

Identifies book names.

 

IdentifiesRFCandInternetdrafttitles.

Italic text like this

Represents variables (options for which

 

you substitute a value) in commands or

 

configuration statements.

Examples

To enter configuration mode, type the configure command:

user@host> configure

user@host> show chassis alarms No alarms currently active

Apolicytermisanamedstructurethat definesmatchconditionsandactions.

Junos System Basics Configuration Guide

RFC 1997, BGP Communities Attribute

Configure the machine’s domain name:

[edit]

root@# set system domain-name domain-name

Plain text like this

Represents names of configuration

 

statements, commands, files, and

 

directories; IP addresses; configuration

 

hierarchy levels; or labels on routing

 

platform components.

To configure a stub area, include the stub statement at the [edit protocols ospf area area-id] hierarchy level.

The console port is labeled CONSOLE.

< > (angle brackets)

Enclose optional keywords or variables.

stub <default-metric metric>;

xxii

Copyright © 2010, Juniper Networks, Inc.

About This Topic Collection

Text and Syntax Conventions

 

 

Convention

Description

Examples

| (pipe symbol)

Indicatesachoicebetweenthemutually

broadcast | multicast

 

exclusivekeywordsorvariablesoneither

 

 

side of the symbol. The set of choices is

(string1 | string2 | string3)

 

oftenenclosedinparenthesesforclarity.

 

# (pound sign)

Indicates a comment specified on the

rsvp { # Required for dynamic MPLS only

 

samelineastheconfigurationstatement

 

 

to which it applies.

 

[ ] (square brackets)

Enclose a variable for which you can

community name members [

 

substitute one or more values.

community-ids ]

Indention and braces ( { } )

Identify a level in the configuration

[edit]

 

hierarchy.

routing-options {

 

 

static {

 

 

route default {

 

 

nexthop address;

 

 

retain;

 

 

}

 

 

}

 

 

}

; (semicolon)

Identifies a leaf statement at a

 

 

configuration hierarchy level.

 

J-Web GUI Conventions

 

 

Bold text like this

Represents J-Web graphical user

IntheLogicalInterfacesbox,selectAll

 

interface (GUI) items you click or select.

Interfaces.

 

 

To cancel the configuration, click

 

 

Cancel.

> (bold right angle bracket)

Separates levels in a hierarchy of J-Web

In the configuration editor hierarchy,

 

selections.

select Protocols>Ospf.

Documentation Feedback

We encourage you to provide feedback, comments, and suggestions so that we can improve the documentation. Send e-mail to techpubs-comments@juniper.net with the following:

Document URL or title

Page number if applicable

Software version

Your name and company

Copyright © 2010, Juniper Networks, Inc.

xxiii

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

Requesting Technical Support

TechnicalproductsupportisavailablethroughtheJuniperNetworksTechnicalAssistance Center (JTAC). If you are a customer with an active J-Care or JNASC support contract, or are covered under warranty, and need post-sales technical support, you can access our tools and resources online or open a case with JTAC.

JTAC policies—For a complete understanding of our JTAC procedures and policies, review the JTAC User Guide located at http://www.juniper.net/us/en/local/pdf/resource-guides/7100059-en.pdf .

Product warranties—For product warranty information, visit http://www.juniper.net/support/warranty/ .

JTAC hours of operation—The JTAC centers have resources available 24 hours a day, 7 days a week, 365 days a year.

Self-Help Online Tools and Resources

For quick and easy problem resolution, Juniper Networks has designed an online self-service portal called the Customer Support Center (CSC) that provides you with the following features:

Find CSC offerings: http://www.juniper.net/customers/support/

Search for known bugs: http://www2.juniper.net/kb/

Find product documentation: http://www.juniper.net/techpubs/

Find solutions and answer questions using our Knowledge Base: http://kb.juniper.net/

Download the latest versions of software and review release notes: http://www.juniper.net/customers/csc/software/

Search technical bulletins for relevant hardware and software notifications: https://www.juniper.net/alerts/

Join and participate in the Juniper Networks Community Forum: http://www.juniper.net/company/communities/

Open a case online in the CSC Case Management tool: http://www.juniper.net/cm/

Toverifyserviceentitlementbyproductserialnumber,useourSerialNumberEntitlement (SNE) Tool: https://tools.juniper.net/SerialNumberEntitlementSearch/

Opening a Case with JTAC

You can open a case with JTAC on the Web or by telephone.

Use the Case Management tool in the CSC at http://www.juniper.net/cm/ .

Call 1-888-314-JTAC (1-888-314-5822 toll-free in the USA, Canada, and Mexico).

For international or direct-dial options in countries without toll-free numbers, see

http://www.juniper.net/support/requesting-support.html .

xxiv

Copyright © 2010, Juniper Networks, Inc.

PART 1

Switch and Components Overview and

Specifications

EX3200 and EX4200 Switches Overview on page 3

Component Descriptions on page 13

Component Specifications on page 39

Copyright © 2010, Juniper Networks, Inc.

1

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

2

Copyright © 2010, Juniper Networks, Inc.

CHAPTER 1

EX3200 and EX4200 Switches Overview

EX3200 and EX4200 Switches Hardware Overview on page 3

EX3200 Switch Models on page 6

EX4200 Switch Models on page 6

Chassis Physical Specifications for EX3200 and EX4200 Switches on page 7

Front Panel of an EX3200 Switch on page 7

Rear Panel of an EX3200 Switch on page 8

Front Panel of an EX4200 Switch on page 9

Rear Panel of an EX4200 Switch on page 11

EX3200 and EX4200 Switches Hardware Overview

Juniper Networks EX Series Ethernet Switches provide scalable connectivity for the enterprise market, including branch offices, campus locations, and data centers. The switches run under the Juniper Networks Junos operating system (Junos OS), which provides Layer 2 and Layer 3 switching, routing, and security services. The same Junos OS code base that runs on EX Series switches also runs on all Juniper Networks J Series, M Series, MX Series, and T Series routers.

EX3200 and EX4200 Switch Types on page 3

EX3200 Switches on page 4

EX4200 Switches on page 4

Uplink Modules on page 5

Power over Ethernet (PoE) Ports on page 5

EX3200 and EX4200 Switch Types

JuniperNetworksEX3200andEX4200EthernetSwitchesaretwocloselyrelatedproduct

lines:

EX3200 switches—Typically, you deploy these switches in branch environments or wiring closets.

EX4200 switches—You can interconnect EX4200 switches to form a Virtual Chassis that operates as a single network entity. You can deploy these switches wherever you need a high density of Gigabit Ethernet ports (24 to 480 ports), redundancy, or the

Copyright © 2010, Juniper Networks, Inc.

3

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

abilitytospanasingleswitchacrossseveralwiringclosets. Typically,EX4200switches are used in large branch offices, campus wiring closets, and top-of-rack locations in a data center.

Both lines have these features:

Run under Junos OS for EX Series switches

Have options of 24-port and 48-port models

Haveoptionsoffull(allports)orpartial(8ports)PoweroverEthernet(PoE)capability

Have optional uplink modules that provide connection to distribution switches

EX3200 Switches

EX3200switchesprovideconnectivityforlow-densityenvironments.Typically,youdeploy theseswitchesinbranchenvironmentsorwiringclosetswhereonlyoneswitchisrequired.

EX3200 switches are available in models with either 24 or 48 ports and with either all portsequippedforPoweroverEthernet(PoE)oronly8portsequippedforPoE.Allmodels provide ports that have 10/100/1000Base-T Gigabit Ethernet connectors and optional 1-gigabit small form-factor pluggable (SFP) transceivers, 10-gigabit small form-factor pluggable (SFP+) transceivers, or 10-gigabit small form-factor pluggable (XFP) transceivers for use with fiber connections.

EX3200 switches include:

Afield-replaceablepowersupplyandanoptionaladditionalconnectiontoanexternal power source.

A field-replaceable fan tray with single fan.

Junos OS with its modular design that enables failed system processes to gracefully restart.

EX4200 Switches

EX4200 switches provide connectivity for mediumand high-density environments and scalability for growing networks. These switches can be deployed wherever you need a highdensityofGigabitEthernetports(24to480ports)orredundancy.Typically,EX4200 switches are used in large branch offices, campus wiring closets, and data centers where theycanbepositionedasthetopdeviceinaracktoprovideconnectivityforallthedevices in the rack.

You can connect individual EX4200 switches together to form one unit and manage the unit as a single chassis, called a Virtual Chassis. You can add more member switches to the Virtual Chassis as needed, up to a total of 10 members.

EX4200 switches are available in models with 24 or 48 ports and with either all ports equipped for Power over Ethernet (PoE) or only 8 ports equipped for PoE. All models provide ports that have 10/100/1000Base-T Gigabit Ethernet connectors and optional 1-gigabit small form-factor pluggable (SFP) transceivers, 10-gigabit small form-factor

4

Copyright © 2010, Juniper Networks, Inc.

Chapter 1: EX3200 and EX4200 Switches Overview

pluggable (SFP+) transceivers, or 10-gigabit small form-factor pluggable (XFP) transceivers for use with fiber connections.

Additionally, a 24-port model provides 100Base-FX/1000Base-X SFP ports. This model is typically used as a small distribution switch.

All EX4200 switches have dedicated 64-Gbps Virtual Chassis ports that allow you to connect the switches to each other. You can also use optional uplink module ports to connect members of a Virtual Chassis across multiple wiring closets.

To provide carrier-class reliability, EX4200 switches include:

Dual redundant power supplies that are field-replaceable and hot-swappable. An optional additional connection to an external power source is also available.

A field-replaceable fan tray with three fans. The switch remains operational if a single fan fails.

RedundantRoutingEnginesinaVirtualChassisconfiguration.Thisredundancyenables GRES (graceful Routing Engine switchover) and nonstop active routing.

Junos OS with its modular design that enables failed system processes to gracefully restart.

Uplink Modules

Optional uplink modules are available for all EX3200 and EX4200 switches. Uplink modules provide two 10-gigabit small form-factor pluggable (XFP) transceivers, four 1-gigabit small form-factor pluggable (SFP) transceivers, or two 10-gigabit small form-factor pluggable (SFP+) transceivers. You can use XFP, SFP, or SFP+ ports to connect an access switch to a distribution switch or to interconnect member switches of a Virtual Chassis across multiple wiring closets.

Power over Ethernet (PoE) Ports

PoEportsprovideelectricalcurrenttodevicesthroughthenetworkcablessothatseparate power cords for devices such as IP phones, wireless access points, and security cameras are unnecessary. Both the EX3200 and EX4200 switches have options of full (all 24 or 48 ports) or partial (8 ports) PoE capability.

Full PoE models are primarily used in IP telephony environments. Partial PoE models are used in environments where, for example, only a few ports for wireless access points or security cameras are required.

Related Topics EX3200 Switch Models on page 6

EX4200 Switch Models on page 6

Field-Replaceable Units in EX3200 and EX4200 Switches on page 18

Site Preparation Checklist for EX3200 and EX4200 Switches on page 87

Copyright © 2010, Juniper Networks, Inc.

5

Complete Hardware Guide for EX3200 and EX4200 Ethernet Switches

EX3200 Switch Models

TheEX3200switchisavailablewith24or48portswithpartialorfullPoweroverEthernet (PoE) capability. Table 1 on page 6 lists the EX3200 switch models.

Table 1: EX3200 Switch Models

 

 

 

Number of

Power Supply

Model

Typical Deployment

Access Ports

PoE-enabled Ports

(Minimum)

EX3200-24T

Access or Distribution

24 Gigabit Ethernet

First 8 ports

320 W

 

switch

 

 

 

EX3200-24P

Access switch

24 Gigabit Ethernet

All 24 ports

600 W

EX3200-48T

Access or Distribution

48 Gigabit Ethernet

First 8 ports

320 W

 

switch

 

 

 

EX3200-48P

Access switch

48 Gigabit Ethernet

All 48 ports

930 W

Related Topics EX4200 Switch Models on page 6

Front Panel of an EX3200 Switch on page 7

Rear Panel of an EX3200 Switch on page 8

EX3200 and EX4200 Switches Hardware Overview on page 3

EX4200 Switch Models

The EX4200 switch is available with 24 or 48 ports and with partial or full Power over

Ethernet (PoE) capability. Table 2 on page 6 lists the EX4200 switch models.

Table 2: EX4200 Switch Models

 

 

 

Power Supply

Model

Ports

Number of PoE-enabled Ports

(Minimum)

EX4200-24T

24 Gigabit Ethernet

First 8 ports

320 W

EX4200-24P

24 Gigabit Ethernet

All 24 ports

600 W

EX4200-48T

48 Gigabit Ethernet

First 8 ports

320 W

EX4200-48P

48 Gigabit Ethernet

All 48 ports

930 W

EX4200-24F

24 small form-factor pluggable

Not applicable

320 W

 

(SFP) transceivers

 

 

Related Topics EX3200 Switch Models on page 6