Data Sheet 606715

Page 1/2

 

 

 

 

 

 

 

 

JUMO setpoint adjusters for thermostats,

EM series

Individual components:

spindle-fitting knobs, adjustable stops, setpoint dials, surrounds, screws

01

 

21

 

11

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

01

 

21

 

11

 

18

 

Spindle-fitting knobs for

Setpoint dial

 

Stop for knobs 01 and 02

Fixing screws

 

pushing onto 6 mm dia. shafts,

(see Data Sheet 602021

 

 

M3 x 8 DIN 84

 

with 4.6 mm flat

for standard ranges)

 

 

 

 

Part no.

60 701 205

 

 

Part no.

60 701 203

Part no.

60 037 100

Max. dia.

30.0 mm

Outer dia.

50.0 mm

Limiting

to limit the scale

Material

nickel-plated

Height

19.0 mm

Height

4.8 mm

 

max. endpoint,

 

brass

Index radius

17.5 mm

Fixing

with two M3

 

right stop

 

 

Panel hole

14.0 mm

 

screws

Adjustment

125 to 250°

 

 

Operating

+120 °C

Spacing

22.0 mm

 

angle

 

 

temperature

Marking

iron-grey

 

 

 

 

Material

thermoplastic,

Operating

RAL 7011

 

 

 

 

 

slate grey

+120 °C

12

 

 

 

 

RAL 7015

temperature

Stop for knob 01 only

 

 

 

 

Material

thermoplastic,

 

 

 

 

Part no.

60 701 202

 

 

 

 

 

flint grey

 

 

 

 

 

RAL 7032

Limiting

to limit the scale

 

 

 

 

Dial divisions

over 250° angle

 

min. starting

 

 

 

 

 

 

 

point,

 

 

 

 

 

 

 

left stop

 

 

 

 

 

 

Adjustment

0 to 125°

 

 

 

 

 

 

 

angle

 

 