Jotul Jtul GI 425 DV User Manual

Jøtul GI 425 DV Camden Classic
Direct Vent Gas Fireplace Insert
IF THE INFORMATION IN THESE INSTRUC­TIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROP­ERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
INSTALLATION:
INSTALLATION AND SERVICE MUST BE PER­FORMED BY A QUALIFIED INSTALLER, SER­VICE AGENCY OR LICENSED GAS SUPPLIER.
WHAT TO DO IF YOU SMELL GAS:
• DO NOT TRY TO LIGHT ANY APPLIANCE.
• DO NOT TOUCH ANY ELECTRICAL SWITCHES.
• DO NOT USE THE PHONE IN YOUR BUILDING. IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S PHONE.
• FOLLOW YOUR GAS SUPPLIER’S INSTRUCTIONS.
• IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT.
Installation and Operation Instructions
AVERTISSEMENT:
ASSUREZ-VOUS DE BIEN SUIVRE LES IN­STRUCTIONS DANS CETTE NOTICE POUR REDUIRE AU MINIMUM LE RISQUE D’INCENDIE OU POUR EVITER TOUT DOMMAGE MATERIEL, TOUTE BLESSURE OU MORTALIT’E.
NE PAS ENTREPOSER NI UTILISER D’ESSENCE NI OU LIQUIDES INFLAMMABLES DANS LE VOISINAGE DE CET APPAREIL OU DE TOUT AUTRE APPAREIL.
L’INSTALLATION LE SERVICE DOIVENT ETRE EXECUTES PAR UN INSTALLATEUR QUALIFIE, AGENCE DE SERVICE OU LE FOURNISSEUR DE GAZ.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ.
• NE PAS TENTER D’ALLUMER L’APPAREIL
• NE TOUCHEZ A AUCUM NTERRUPTEUR.
• NE PAS VOUS SERVIR DES TELEPHONES SE TROUVANT DANS LE BATIMENT OU VOUS VOUS TROUVEZ.
• APPELEZ IMMEDIATEMENT VOTRE FOURNISSEUR DE GAZ CHEZ UN VOISIN. SUIVEZ LES INSTRUCTIONS DU FOURNISSEUR.
• SI VOUS NE POUVEZ REJOINDRE LE FOURNISSEUR DE GAZ, APPELEZ LE SER­VICE DES INCENDIES.
Welcome to Jøtul...
Congratulations on the purchase of your new Jøtul GI 425 DV Camden Gas Fireplace.
We at Jøtul are glad you’ve made the decision to warm your hearth with one of our products. We’ve been making fine quality cast iron stoves and fireplaces continuously since 1853. Your new Camden fireplace is the result of our experience as the world’s largest manufacturer of solid fuel burning appliances for over 150 years.
In the GI 425 DV Camden, we’ve combined advanced gas technology with the warm, traditional elements of cast iron. With proper care and use, your Jøtul fireplace will provide you with many years of safe, dependable and satisfying service.
The GI 425 DV is a direct vented gas heater designed and approved for installation into an existing masonry fireplace. Please take a few minutes to familiarize yourself with this manual and the features of your new gas fireplace.
PLEASE READ THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM AVAILABLE TO ANYONE USING OR SERVICING THIS APPLIANCE.
THIS PRODUCT MUST BE INSTALLED BY A LICENSED MASTER OR JOURNEYMAN PLUMBER OR GAS-FITTER WHEN INSTALLED IN THE COMMONWEALTH OF MASSACHUSETTS.
2
Table of Contents
Specifications ............................. 4
Installation & Service Tools .......... 4
General Information................... 5
Safety Information.......................... 6
Installation
Fireplace Requirements ............ 4
Clearances ....................................... 8
Hearth Protection ......................... 9
Vent Requirements ..................... 10
Masonry Fireplace .......................11
Prefabricated Fire ........................ 12
Unpacking the Fireplace
1. Before you remove the carton, remove the cast
iron parts that are packed around the fireplace firebox.
Fireplace Assembly
Gas Connection ............................ 14
Gas Pressure..................................14
High Altitude Adjustment ........ 15
Fuel Conversion ............................ 16
Wall Thermostat .......................... 18
Remote Control ............................18
Antique Brick Kit .......................... 19
Log Set Installation ..................... 20
Surround Assembly.....................21
System Check................................22
Operation
Burner Controls...........................24
Blower............................................25
Maintenance
Annual Cleaning ......................... 26
Glass Replacement ..................... 26
Illustrated Part Breakdown ...... 28
2. Lift the shipping carton off of the fireplace cabinet.
3. Unpack the Firebox. The Logset is packaged inside
the firebox. Remove the Glass Panel Frame to unpack the firebox:
• Locate the right and left spring latches on the underside of the firebox floor. Release each latch by pulling them forward to disengage the Frame from the Firebox body.
• Pull the Glass Frame away from the Firebox and lift to disengage it from the three steel retainer tabs located at the top of the firebox. Set the glass out of the way.
Do not unpack the log parts until you are ready to install them.
4. Install the Levelling Bolts. Five round head
carriage bolts are included in the Hardware Bag. Tilt the insert cabinet back on the pallet to allow clearance for installation of these bolts into the Cabinet Base, one at each corner and one in the center.
Spring Latch
Replacement Parts List ............. 29
Service Log ................................ 30
Lighting Instructions ................ 31
Pull each Spring Latch to disengage them from the Glass Frame.
3
Jøtul GI 425 Camden
Direct Vent Gas Fireplace
Manufactured and Distributed by:
Jøtul A.S.A.
Fredrikstad, Norway
Jøtul North America
Portland, Maine
Test Standards
This appliance complies with National Safety standards and is tested and listed by Intertek Testing Services of Middleton, Wisconsin.
In addition, the GI 425 gas fireplace insert has been tested and listed as a direct vent gas fireplace heater and listed to ANSI Z21.88-1998 (NFPA 54) and CSA 2.33-M98 for Canada.
Specifications
Input Rates
Natural Gas
26,000 BTU/hr. maximum input 13,000 BTU/hr. minimum input
Propane
26,000 BTU/hr. maximum input 13,000 BTU/hr. minimum input
Accessories
Antique Brick Panel Kit....................................... #155311
Wide Surround Kit - Cast Iron Max. Opening Overlap: 47” Wide x 33 1/2” High.
Matte Black ................................................... #155323
Blue Black Enamel ....................................... #155324
Jøtul Iron Gray .............................................. #155354
Fuel Conversion Kit - NG to LP ......................... #155300
Fuel Conversion Kit - LP to NG ......................... #155303
Wall Thermostat................................................... #750003
Remote Control..................................................... #129706
Jøtul QuickFace™ System
Rectangular Frame w/ Screen,
Brushed Stainless Steel ............................. #155312
Arched Frame w/ Screen,
Brushed Stainless Steel ............................. #155313
Rectangular Frame w/ Screen,
Matte Black ................................................... #155314
Arched Frame w/ Screen,
Matte Black ................................................... #155315
Double Doors, Cast Iron -
Matte Black ................................................... #350565
Double Doors, Cast Iron -
Blue Black Enamel ....................................... #350566
Inlet Pressure: MIN MAX
Natural Gas: 5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa) Propane: 12.0 WC (2.98 kPa) 14.0 WC (3.48 kPa)
Manifold Pressure: MIN MAX
Natural Gas: 1.2 WC (0.29 kPa) 3.8 WC (0.95 kPa) Propane: 2.9 WC (0.72 kPa) 11.0 WC (2.74 kPa)
Steady State Efficiency: 77.3%
A.F.U.E. Efficiency: 67.9%
Piezo Ignitor / Standing Pilot
NN
AA
THIS FIREPLACE IS SHIPPED AS A GAS GAS
GAS FIREPLACE ONLY. IF USE WITH PRO-
GAS GAS PANE IS DESIRED, THE FIREPLACE MUST BE CONVERTED TO USE WITH PROPANE. FOR YOUR CONVENIENCE THIS FIREPLACE IS SHIPPED WITH A PROPANE CONVERSION KIT.
N
A
NN
AA
TURALTURAL
TURAL
TURALTURAL
Suggested Tools for Installation and Service
• External regulator (for Propane only)
• Piping which complies with local code
• Manual shutoff valve - T-Handle in Massachusetts
• Sediment trap - if required by code
• Tee joint
• Pipe wrench
• Pipe sealant
• 10mm open end wrench
• 1/2”, 7/16” open end wrench
• Phillips head screwdriver
• Flat head screwdriver
• 1/4” nut driver
• Gloves
• Safety glasses
• Torx T20 screwdriver
• Leak test solution
• Power Drill
4
General Information
IMPORTANT:
SAVE THESE INSTRUCTIONS.
THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED SERVICE AGENCY.
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THIS APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION WILL VOID THE WARRANTY, CERTIFICATION AND LISTING OF THIS APPLIANCE.
1. The installation and repair of this appliance must be done by a qualified service person. Failure to properly install and maintain this heater could result in an unsafe or hazardous installation, which may result in a fire, explosion, property damage, personal injury or loss of life.
2. This appliance should be inspected before use and at least annually. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulat­ing air passageways of the appliance be kept clean.
`S’assurer que le bruleur et le compartiment des commandes sont propres. Voir les instructions d’installation et d’utilisation qui accompagnent l’appareil.
3. The installation must conform to local codes. Your local Jøtul authorized dealer can assist you in determining what is required in your area for a safe and legal installation. Some areas require a permit to install a gas burning appliance. Always consult your local building inspector or authority having jurisdiction to determine what regulations apply in your area.
In the absence of local codes, the installation requirements must comply with the current National codes. In the U.S., these requirements are established in the National Fuel Code, ANSI Z223.1.(NFPA 54). In Canada, the codes have been established in CAN/CGA B149 Fuel Installation Code.
Installer l’appareil selon les codes ou reglements locaux, ou, en l’absence de tels reglements, selon les Codes d’installation CAN/CGA-B149.
4. DO NOT OPERATE THIS FIREPLACE IF ANY PART HAS BEEN UNDER WATER.
Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.
Ne pas se servir de cet appareil s’il a ete’ plonge dans l’eau, completement ou en partie. Appeler un technicien qualifie pour inspecter l’appareil et remplacer toute partie du syste’me de controle et toute commande qui ont ete plonges dans l’eau.
5. Do not operate the fireplace with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. Only remove glass for routine service. Always handle glass carefully.
Pour utilisation avec les portes en verre cerifiers aved l’appareil seulemend ou. Ne pas utiliser avec des portes on verre.
6. Notify your insurance company before proceding with installation of this fireplace.
5
Safety Information
Installation
Due to the high operating temperatures this
appliance should be located out of traffic and away from furniture, draperies, etc. Maintain proper clearance to combustible mantels and fireplace trim.
Children and adults should be alerted to the
hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be supervised while they
are in the same room as the GI425 gas fireplace. Surveiller les enfants. Garder les vetements, les
meubles, l’essence ou autres liquides a vapeur inflammables loin de l’appareil.
Clothing or other flammable materials should
not be placed ON or NEAR the GI425 gas fire­place.
Never allow any to use the fireplace if they are
unfamiliar with its operation.
NEVER store or use gasoline or any other flam-
mable vapors or liquids in the vicinity of the GI425 gas fireplace.
Never burn any solid materials (wood, cardboard,
paper, coal, etc.) in this gas fireplace. Use with natural gas or propane fuel ONLY.
Any safety screen, glass or guard removed for
servicing the appliance must be replaced prior to operating the appliance.

Do not slam or strike the glass panel.


Were gloves and safety glases while performing

maintenance procedures.
Electrical Hazard

Be aware of electrical wiring locations when

cutting holes in walls and ceilings for termina­tion.

The GI425 Blower must be electrically grounded

in accordance with local codes or, in the absence of local codes, with the current ANSI/NFPA 70, National Electrical Code or CSA C22.1-Canadian Electrical Code.

The GI425 Blower is supplied with a three-prong

(grounding) plug for protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG.

Always disconect the power supply when per-

6
forming routine service on the fireplace.
Requirements
The GI425 DV Camden Gas Insert can be installed in most solid fuel burning fireplaces of either masonry construction or a prefabricated factory built fire­place.
Prior to any installation of the GI425 DV Camden the existing chimney exhaust flue must be thor­oughly cleaned and completely inspected by a qualified chimney sweep or fireplace service person.
Do not install this insert into a chimney that is damaged. Any repairs must be made prior to install­ing the insert. If you are unsure of the condition of your fireplace and chimney, contact a professional fireplace technician or your local authorized Jøtul dealer for professional assistance.
DO NOT REMOVE BRICKS OR MORTAR FROM THE FIREPLACE OR CHIMNEY STRUCTURE. However,
masonry or steel may be removed from the smoke shelf and adjacent damper frame area to accommo­date installation of a chimney liner, provided that their removal will not weaken the structure of the fireplace or chimney, and will not reduce protection for combustible materials.
If the fireplace has been modified to accommo­date installation, use anchors or masonry nails to
attach the metal Fireplace Conversion Notice Plate to the back wall of the masonry fireplace firebox where it will be readily seen should the insert be removed.
THIS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY OR FLUE SERVING ANY OTHER APPLIANCE OF ANY KIND.
All venting components must be installed in accordance with the terms of their listing and manufacturer’s instructions. Refer to the pipe manufacturer’s instructions for proper pipe clear­ances.
This fireplace insert is specifically designed for use with 3” Type B vent pipe components or a Listed Flexible gas liner.
Do not modify or alter the construction of the gas insert or any of its components to enable it to fit into a fireplace. Any modification of the insert will void the warranty, certifications and approvals of the unit and could be dangerous.
25
E
C
D
A
B
635 mm
20
508 mm
7 1/2
191 mm
Exhaust
Outlet
1016 mm
Figure 1. GI 425 DV dimensions.
40
Air
Intake
11
289 mm
1 1/2
38mm
13
330 mm
8 1/2 (216 mm)
30 1/4
768 mm
127 mm
Air
Intake
2
50 mm
22
559 mm
17
432 mm
Exhaust
Outlet
5
21 1/2
546 mm
Minimum Fireplace Requirements
The GI425 DV CAMDEN gas insert has been specifically designed to be installed into a solid fuel burning factory built fireplace OR a code approved solid fuel burning masonry fireplace with a tile flue liner. An acceptable fireplace cavity must have the minimum dimensions specified below.
22
Surround
Hangers
A: Opening Width = 28” (711 mm) B: Opening Height = 22” (559 mm) C: Back Wall Width = 20” (508 mm) D: Back Wall Height = 20” (508 mm) E: Depth = 13” (330 mm)
for Surround Hanger Clearance
28
711 mm
Min. Opening Width
Figure 2. Minimum fireplace cavity dimensions. Figure 3. Minimum opening clearance. Optional
Lattice Surround shown.
559 mm
Min.
Opening
Height
7
Covering the Fireplace Opening
Clearance Requirements
Two cast iron surround styles are available for the GI 425 Camden fireplace insert.
Standard Classic Surround
The GI425 Camden includes Surround Panels that will overlap a maximum fireplace opening
39” Wide x 29 1/2” High.
The actual standard surround dimensions are 40” Wide x 30 1/4” High.
Optional Lattice Classic Surround
The Lattice Surround Kit shares the same dimensions as the standard Classic Surround described above. #350557 - Matte Black #350558 - Blue Black. #350559 - Jøtul Iron
Optional Wide Surround
#155323 - Matte Black #155324 - Blue Black. #155354 - Jøtul Iron These optional panels can be used to extend the Classic or Lattice surround panels to cover oversize fireplace openings up to a maximum 47” Wide x 33
1/2” High.
The actual wide surround dimensions are 48” Wide x 34” High.
NOTE: The additional weight of the Wide Surround may necessitate use of the Anchor Bracket which is included with this fireplace. The anchor will ensure that the surround assembly aligns properly against the fireplace face. Use the installation instructions included in the Hardware bag.
The following clearances and hearth requirements are the minimum requirements when installing the Camden gas insert into a solid fuel burning appli­ance. These dimensions are measured from the firebox cabinet to the combustible material. See figures 5 and 6.
A combustible surface is anything that can burn (i.e. sheet rock, wallpaper, wood, fabrics etc.). These surfaces are not limited to those that are visible and also include materials that are behind non-combustibles.
If you are not sure of the combustible nature of a material, consult your local fire officials. Remem­ber, “Fire Resistant” materials are considered combustible: they are difficult to ignite, but will burn. Also, “fire-rated” sheet rock is considered combustible.
Always maintain the proper clearances to the appliance for the proper flow of ventilation air around the insert.
Figure 5. Clearance to Adjacent Combustible Material - measured from the firebox cabinet.
F
E
48
1219 mm
Figure 4. Wide Surround Dimensions.
SEE PAGE 21 FOR SURROUND PANEL
ASSEMBLY INSTRUCTIONS.
8
34
864 mm
B
A: Hearth Protection Width - None required B: Hearth Protection Depth - None required C: Side Trim Clearance, 1” thick (25 mm) = 9.5 in. (241 mm) D: Side Room Wall Clearance = 27.5 in. (698 mm) E: Top Trim Clearance = 17 1/2 in. (444 mm) F: Mantel Clearance at 9 in. max. depth = 27.5 in. (698 mm)
Mantel Clearance at 3.5 in. max. depth = 19.5 in. (495 mm)
A
C
D
Mantel and Trim Clearance
9
228 mm
8
6 1/2
5
3 1/2
UPPER
TRIM
1 Max.
27 1/2
736 mm
21 1/2
622 mm
Depth
25 1/2
698 mm
23 1/2
660 mm
TOP OF FIREBOX
19 1/2
508 mm
17 1/2
394 mm
CABINET
22
559 mm
Figure 6. Minimum Mantel Clearances. Measure clearances from the top and sides of the fireplace cabinet before installation of the cast iron surround panels.
Hearth Requirements
The Jøtul GI425 Camden does not require special hearth protection. Combustible flooring materials may be present directly in front of the fireplace insert.
9
Vent Guidelines
• All vent components must be installed in accor­dance with the listing terms and manufacturer’s instructions.
Vent Height: Measured from the top of the insert to the top of the termination cap.
Minimum: no less than 10' Maximum: no greater than 35'. See figures 9 and 10.
The minimum vent height above the roof or adjacent walls is specified by building codes. As a general guide, follow the Gas Vent Rule on page
12.
HORIZONTAL RUNS ARE NOT PERMITTED ANY-
WHERE IN THE VENTING SYSTEM.
Venting liners used on this appliance may not be less than 3” in diameter or greater than 3” in diameter.
• Any unused flue or masonry enclosure can be used as a passageway for venting provided the flue is relined using 3” Listed flexible gas liner.
• The remaining space around the liner in a ma­sonry or zero-clearance flue CANNOT be used to vent any other appliance.
• Flexible liner components may not be exposed in any living space.
Installation of any components not manufactured
or approved by Jøtul or failure to meet all clear­ance requirements will void all warranties and could result in property damage, bodily injury, or serious fire.
Never modify any venting component, or use any damaged venting product.
THE GAS APPLIANCE AND VENT SYSTEM MUST BE VENTED DIRECTLY TO THE OUTSIDE OF THE BUILD­ING, AND NEVER ATTACHED TO A CHIMNEY SERVING A SOLID FUEL OR GAS BURNING APPLI­ANCE.
• Variable Vent Restriction: See the System Check section on pages 22-23 for specific instructions.
IMPORTANT NOTICE:
THE USE OF AN EXISTING CHIMNEY AS AN AIR INTAKE IS NOT COVERED UN­DER THE ANSI Z21.88-1999-CSA 2.33­M99 TEST METHODS AND RESULTING ITS/WHI PRODUCT CERTIFICATION. THE CODE AUTHORITY HAVING JURIS­DICTION MUST BE CONSULTED PRIOR TO PROCEEDING WITH THIS INSTALLA­TION METHOD.
Masonry Fireplace Installation
When installing a GI425 DV Camden gas insert into a masonry fireplace the insert will be vented through dual 3” flexible gas aluminum liners.
This co-linear installation includes a pair of 3” flex ducts that run from the insert completely through the existing chimney to the termination cap.
One liner is attached to the Exhaust Outlet on the back of the unit and will carry the exhaust gases to the outside of the house. This exhaust liner must be directly connected to the unit and run the full length of the chimney. See figure 7.
The other 3” liner will be attached to the Air Intake Collar on the back of the unit to provide fresh air for combustion. The Intake Collar is labeled for easy identification. The liner must extend a mini- mum of 6’ off the back of the unit and extend through the damper area of the fireplace into the tile liner of the chimney. This liner can also extend the full length of the chimney and connect to the termination cap.
IMPORTANT
If the intake flex does not extend the full length of the chimney, forming a direct connection between the unit and the termination cap, A METAL BLOCK OFF PLATE MUST BE INSTALLED to seal the air intake from room air. Normally this sealing plate will be installed within the existing fireplace damper area. See figure 7. The sealing plate is not necessary if a direct connection is made between the cap and the fireplace.
WARNING! Avoid cross venting the insert. Before installation, label both ends of the exhaust flex pipe to ensure connection to the appropriate collars on the fireplace unit and vent termination cap.
CANADA REQUIREMENT: Both the Intake and
the Exhaust liners must extend the full
length of the chimney and be securely
connected to both the unit and the termina-
tion kit.
If the fireplace has been modified to accom-
modate installation, use anchors or masonry
nails to attach the metal Fireplace Conver-
sion Notice Plate supplied with this unit to
the back wall of the masonry fireplace
firebox where it will be readily seen should
the insert be removed.
10