Jotul GF 3 BV User Manual

0 (0)
Jotul GF 3 BV User Manual

GF 3 BV

ALLAGASH

B-Vent Gas Heater

Installation

and Operation

Instructions

Warnock Hersey

C US

WARNING:

IF THE INFORMATION IN THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY:

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

INSTALLATION:

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR LICENSED GAS SUPPLIER.

WHAT TO DO IF YOU SMELL GAS:

DO NOT TRY TO LIGHT ANY APPLIANCE.

DO NOT TOUCH ANY ELECTRICAL SWITCHES.

DO NOT USE THE PHONE IN YOUR BUILDING. IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S PHONE.

FOLLOW YOUR GAS SUPPLIER’S INSTRUCTIONS.

IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT.

AVERTISSEMENT:

ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUCTIONS DANS CETTE NOTICE POUR REDUIRE AU MINIMUM LE RISQUE D’INCENDIE OU POUR EVITER TOUT DOMMAGE MATERIEL, TOUTE BLESSURE OU MORTALIT’E.

NE PAS ENTREPOSER NI UTILISER D’ESSENCE NI OU LIQUIDES INFLAMMABLES DANS LE VOISINAGE DE CET APPAREIL OU DE TOUT AUTRE APPAREIL.

L’INSTALLATION LE SERVICE DOIVENT ETRE EXECUTES PAR UN INSTALLATEUR QUALIFIE, AGENCE DE SERVICE OU LE FOURNISSEUR DE GAZ.

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ.

NE PAS TENTER D’ALLUMER L’APPAREIL

NE TOUCHEZ A AUCUM NTERRUPTEUR.

NE PAS VOUS SERVIR DES TELEPHONES SE TROUVANT DANS LE BATIMENT OU VOUS

VOUS TROUVEZ.

• APPELEZIMMEDIATEMENTVOTRE FOURNISSEUR DE GAZ CHEZ UN VOISIN. SUIVEZ LESINSTRUCTIONSDUFOURNISSEUR.

• SI VOUS NE POUVEZ REJOINDRE LE FOURNISSEUR DE GAZ, APPELEZ LE SERVICE DES INCENDIES.

Model: Allagash B-Vent

Gas Stove

Manufactured and

Distributed by:

Jøtul A.S.A.

Fredrikstad, Norway

Jøtul North America

Portland, Maine

THIS STOVE IS SHIPPED AS A

NATURAL GAS STOVE ONLY. IF USE WITH PROPANE IS DESIRED, THE STOVE MUST BE CONVERTED TO USE WITH PROPANE. FOR YOUR CONVENIENCE THE STOVE IS SHIPPED WITH A PROPANE CONVERSION KIT.

SUGGESTED TOOL LIST FOR INSTALLLATION AND SERVICE:

*External regulator (for LPG only) *Piping which complies with local code *Manual shutoff valve

*Sediment trap *Tee joint *Pipe wrench *Pipe sealant

*10mm open end wrench *1/2”, 7/16” open end wrench *Phillips head screwdriver *Flat head screwdriver

*1/4” nut driver *Gloves *Safety glasses

*Torx T20 screwdriver *Leak test solution

TABLE OF CONTENTS:

 

 

WELCOME TO JØTUL…………..…....................3

STANDARDS......................................................

 

4

GENERAL INFORMATION…..................….......4

LOCATION…………........……………….............…5

FLOOR PROTECTION..................……......………6

STOVE CLEARANCES…................……....………6

ALCOVE................................................

 

6

PARALLEL INSTALLATION..................

6

CORNER INSTALLATION......................

6

MANTEL, CEILING AND TRIM.............

6

VENTING REQUIREMENTS……….................…7

HEARTHMOUNT...................................

 

8

VENTING GRAPH.................................

 

9

GAS CONVERSION………......................……....10

GAS CONNECTION…..……….......................…12

GAS PRESSURE…..……….......................………12

HIGH ALTITUDE INSTALLATIONS…..............13

AIR SHUTTER ADJUSTMENTS...…...............…14

INSTALLING THE LOG SET………...........….…15

INSTALLING DECORATIVE PIPE BRACKETS....

15

INSTALLING THE BLOWER..............................

 

16

REMOTE/THERMOSTAT.................................

 

17

SPILL SWITCH OPERATION.............................

 

17

CHECKING THE SYSTEM…………...................18

OPERATION OF APPLIANCE...........................

 

19

MAINTENANCE..............................................

 

19

REPLACEMENT PARTS....................................

 

21

ILLUSTRATED PARTS .…………......................22

LIGHTING INSTRUCTIONS ........

Inside Back Cover

THIS OWNER’S OPERATING AND INSTRUCTIONS MANUAL IS DESIGNED TO GIVE YOU A SAFE, EFFICIENT, DEPENDABLE INSTALLATION OF YOUR ALLAGASH B-VENT GAS STOVE.

PLEASE READ THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM AVAILABLE TO ANYONE USING OR SERVICING THE GAS STOVE.

2

28”

22 3/4”

 

 

 

HEIGHT

 

 

 

OF TOP

 

 

 

 

 

 

EXIT IS

 

 

 

 

CENTER

27 1/2”

 

OF REAR

 

 

 

EXIT IS

 

 

23”

 

 

 

 

 

 

 

 

 

WELCOME TO JØTUL:

Congratulations on the purchase of your new Jøtul gas stove.

We at Jøtul are very happy you have made the decision to warm your hearth with a Jøtul product. Your new Jøtul Allagash has inherited the benefits learned from more than 140 years of producing stoves. Jøtul is the world’s largest manufacturer of solid fuel burning appliances and has been making cast iron wood and coal stoves since 1853.

The Allagash incorporates the most advanced gas technology with the warm traditional style of cast iron. With proper care and operation, your new Jøtul will last many, many years.

The Jøtul Allagash gas stove is a gravity vented gas fireplace heater. The Allagash B-Vent gas stove can only be vented vertically directly to the outside, using type B-vent pipe.

The Jøtul Allagash gas stove is designed to operate on NATURAL GAS or PROPANE only. For safe and efficient operation the stove is equipped with a millivolt gas control valve with a piezo ignitor. Electrical power is only required when operating the OPTIONAL forced air blower, if installed on the stove (part # 129161).

13 1/4”

Input Rates

The input rate on the Allagash gas stove is 24,000 4” BTU/hr maximum input on the high setting for both natural gas and propane, adjusted down to 19,000 BTU/hr minimum on the low setting, for

both natural gas and propane.

18 1/2”

 

 

 

 

Natural gas

24,000 BTU/hr. maximum input

 

 

 

 

 

 

 

 

 

 

 

 

 

19,000 BTU/hr. minimum input

 

 

 

 

 

 

Propane

24,000 BTU/hr. maximum input

 

 

 

 

 

 

 

 

 

 

 

 

 

19,000 BTU/hr. minimum input

 

 

 

22 3/4”

 

3

STANDARDS:

This appliance complies with National Safety standards and is tested and listed by ITS, Intertek Testing Services

Middleton, WI

In addition, the Allagash gas stove complies with and has been tested and listed as a gravity vented gas fieplace heater and listed to:

ANSI Z21.88-1998(NFPA 54)

CSA 2.33-M98 for Canada.

DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION WILL VOID THE WARRANTY, CERTIFICATION AND LISTING OF THIS APPLIANCE.

GENERAL INFORMATION:

THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED SERVICE AGENCY.

The installation and repair of this appliance must be done by a qualified service person. Failure to properly install and maintain this heater could result in an unsafe or hazardous installation, which may result in a fire, explosion, property damage, personal injury or loss of life.

This appliance should be inspected before use and at least annually. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.

S’assurer que le bruleur et le compartiment des commandes sont propres. Voir les instructions d’installation et d’utilisation qui accompagnent l’appareil.

The installation must conform to local codes. Your local Jøtul dealer can assist you in determining what is required in your area for a safe and legal installation. Some areas require a permit to install a gas burning appliance. Always consult your local building inspector or authority having jurisdiction to determine what regulations apply in your area.

REMEMBER Your local officials have final authority in determining if a proposed installation is acceptable. Any requirement that is requested by the local authority having jurisdiction, that is not specifically addressed in THIS manual, defaults to local code. In the absence of local codes, the installation requirements must comply with the current National codes. In the U.S. these requirements are established in the National Fuel Code, ANSI Z223.1.(NFPA 54). In Canada, the codes have been established in CAN/CGA B149 Fuel Installation Code.

Installer l’appareil selon les codes ou reglements locaux, ou, en l’absence de tels reglements, selon les Codes d’installation CAN/CGA-B149.

DO NOT OPERATE THIS STOVE IF ANY PART HAS BEEN UNDER WATER.

Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Ne pas se servir de cet appareil s’il a ete’ plonge dans l’eau, completement ou en partie. Appeler un technicien qualifie pour inspecter l’appareil et remplacer toute partie du syste’me de controle et toute commande qui ont ete plonges dans l’eau.

Do not operate the Allagash gas stove with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. Only remove glass for routine service. Always handle glass carefully.

Pour utilisation avec les portes en verre cerifiers aved l’appareil seulemend ou Ne pas utiliser avec des portes on verre.

4

Hot Surfaces

The Allagash gas stove will, during normal operation, reach high surface temperatures therefore:

·Due to the high operating temperatures this appliance should be located out of traffic and away from furniture and draperies.

THIS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY OR FLUE SERVING ANY OTHER APPLIANCE OF ANY KIND.

LOCATION:

In selecting the location, the aesthetic and

·Children and adults should be alerted to the functional use of the appliance are primary hazards of high surface temperatures and concerns; However, proper venting systems and should stay away to avoid burns or clothing access to the fuel supply are also important issues.

ignition.

Due to the high surface temperatures of the

·Young children should be supervised while Allagash, always consider the proximity of traffic

they are in the same room as the Allagash ways, furniture, draperies, etc. gas stove.

·Clothing or other flammable materials This appliance may be located on or near should not be placed ON or NEAR the conventional construction materials. HOWEVER,

Allagash gas stove.

·Surveiller les enfants. Garder les vetements, les meubles, l’essence ou autres liquides a vapeur inflammables loin de l’appareil.

always maintain the proper clearances to combustibles, as this provides adequate ventilation air around the appliance.

·NEVER store or use gasoline or any other The following clearances and hearth requirements

flammable vapors or liquids in the vicinity of the Allagash gas stove.

are the minimum requirements when installing the Allagash gas stove near or on combustible

·Never burn any other materials in your surfaces. Always provide adequate access around Allagash gas stove, it is strictly designed for the appliance for servicing and proper operation. use with natural gas or propane fuel ONLY.

·Any safety screen, glass or guard removed A combustible surface is anything that can burn for servicing the appliance must be replaced (i.e. sheet rock, wall paper, wood, fabrics etc.). prior to operating the appliance. These surfaces are not limited to those that are

Blower/Electrical Hazard

When the Allagash gas stove is installed with the optional forced air Blower Kit (part #129161) the stove must be electrically grounded in accordance with local codes or, in the absence of local codes, with the current NFPA 70National Electrical Code or CSA C22.1-Canadian Code.

The Allagash Blower Kit is already supplied with a three-prong (grounding) plug for protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.

DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG. Always unplug the Blower when performing routine service to the Allagash gas stove.

visible and also include materials that are behind non-combustibles.

If you are not sure of the combustible nature of a material, consult your local fire officials. Remember, “Fire Resistant” materials are considered combustible: they are difficult to ignite, but will burn. Also, “fire-rated” sheet rock is considered combustible.

The Allagsh B-Vent gas stove is not to be connected or installed using any warm air duct system.

Always maintain the proper clearances to the appliance for the proper flow of combustion and ventilation air to the stove.

5

Minimum hearth protection under the Allagash B-Vent gas stove:
22 3/4” wide X 18 3/4” deep

FLOOR PROTECTION:

The Allagash gas stove CANNOT be installed directly on carpeting, vinyl flooring, linoleum or Pergoã.

If it is desired to install this appliance on any combustible material OTHER THAN WOOD, a floor pad must be installed that is either metal, wood or a listed hearth pad. This floor protection must extend the full width and depth of the appliance. It is not necessary to remove the carpeting, vinyl or linoleum from underneath the floor protection.

Note: the hearth requirements are the same when using the optional short leg package.

STOVE CLEARANCES:

Minimum clearances for the Allagash B-Vent gas stove are as follows:

Rear clearance =2”(50mm)

(measured from draft hood)

Ceiling =18”(460mm)

(measured from top of stove)

Corner clearance =3”(76mm)

(measured from rear corners)

Right side clearance = 4”(102mm) Left side clearance = 10” (255mm)

(for access to the lighting instructions)

All venting components must be installed in accordance with the terms of their listing and manufacturer’s instructions. Refer to the pipe manufacturer’s instructions for proper pipe clearances. Any horizontal venting requires a

2” (50mm) top clearance off top of pipe.

ALCOVE

Minimum Alcove Width = 41”(1042mm) (minimum side clearance in an alcove becomes 8” on right side of stove and 10” on left side of stove).

Maximum Alcove Depth = 24”(610mm) Minimum Alcove Height (off stove)= 18”(460mm)

(minimum height off top casting of stove).

Pipe clearances =see manufacturer’s listing.

PARALLEL INSTALLATION

 

 

 

 

 

 

 

 

 

 

2” (50mm) from

 

 

 

 

draft hood

 

 

 

 

 

 

 

 

 

 

 

4”

 

 

 

10”

 

 

 

 

 

(102 mm)

 

 

(255mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

left side

right side

 

wall

 

wall

CORNER INSTALLATION

3” 76mm

3” 76mm

MANTEL, CEILING AND TRIM

MANTEL OR

TRIM DEPTH

 

19”or greater in depth

A

6”- 18” in depth

2”- 5” in depth

B

 

 

C

1” trim only

 

 

MINIMUM

 

CLEARANCES TO TOP

 

PLATE OF STOVE

 

A = 18”

(460mm)

 

B = 12”

(305mm)

 

C = 5”

(127mm)

 

1” trim = 1”

(25mm)

6

VENTING REQUIREMENTS:

The Allagash is specifically designed to operate using 4” Type B vent pipe components or a Listed Flexible gas liner.

FOLLOW THE GUIDELINES LISTED BELOW FOR THE PROPER VENTING OF THE ALLAGASH B-VENT STOVE!

All venting components must be installed in accordance with the terms of their listing and manufacturer’s instructions.

The minimum height of a vertically terminated system shall be no less than 7', and the maximum height shall be no more than 35'. See diagrams page 9.

With steep roofs, nearby trees, and in predominant windy conditions, poor draft or down draft conditions can occur. In these cases, increasing the height of the vent or high wind termination caps may improve the situation.

ELBOWS: If an offset or elbow is necessary in the vertical rise, it is important to support the vent pipe every three feet, to avoid excessive stress on the offsets.

Whenever possible use 45° elbows opposed to 90° elbows. This offers less restrictions for the flow of flue gases.

Maximum number of 90° elbows = three Maximum number of 45° elbows = four

TOTAL MAXIMUM HORIZONTAL RUN ANYWHERE IN THE VENTING CONFIGURATION IS 4 FEET. The distance between any 45° elbows is considered a horizontal run. See diagrams page 9.

Any Type B vent passing through a roof must have a flashing, storm collar, thimble and a Type B cap is required. See diagrams page 9.

Venting on the Allagash CANNOT be less than 4” in diameter or greater than 4” in diameter.

Any UNUSED flue or masonry enclosure can be used as a passage way for venting the Allagash: PROVIDED the flue is relined using Type B 4” vent or Listed Flexible Gas Liner.

The remaining space around the liner in a masonry or zero-clearance flue CANNOT be used to vent any other appliance.

When terminating through the roof refer to the Gas Vent Rule for proper vent termination height. See Figure 1.

Figure 1

NO venting can terminate horizontally or below roof eaves.

Passage through combustibles (walls, ceilings) must be with Type B venting and must maintain listed clearances.

It is recommended that any horizontal runs have an upward slope of 1/4” per foot toward the termination cap.

When venting through a thimble into a masonry flue any venting exposed in the room must be Type B venting.

Listed Flexible Gas Liners may not be exposed in any living space.

7

When decorative 6” pipe is installed to cover the venting any Listed Flexible Gas liner must be connected directly to the stove’s draft hood.

Use of single wall connector pipe as a vent is prohibited for use with theAllagash B-Vent stove.

A firestop is required at every floor.

Any venting that is exposed above the first floor, regardless of attic space or living space, must be enclosed. Always maintain the required clearance from all sides of the vertical vent system according to manufacture.

Installation of any components not manufactured or approved by Jøtul or failure to meet all clearance requirements will void all warranties and could result in property damage, bodily injury, or serious fire.

Never modify any venting component, or use any damaged venting product.

THE GAS APPLIANCE AND VENT SYSTEM MUST BE VENTED DIRECTLY TO THE OUTSIDE OF THE BUILDING, AND NEVER ATTACHED TO A CHIMNEY SERVING A SOLID FUEL OR GAS BURNING APPLIANCES.

BE SURE TO MAINTAIN THE PROPER CLEARANCES TO COMBUSTIBLES AS DEFINED IN THIS MANUAL AND IN THE INSTRUCTIONS PROVIDED WITH EACH VENTING COMPONENT.

When installing at an altitude above 2000’ the minimum vertical rise becomes 12’ from the draft hood.

If more than two feet of venting is exposed to the outside, the entire exterior vent system must be enclosed in an insulated chase system.

Allagash B-Vent gas stove vented into a masonry or prefabricated fireplace.

Listed termination cap required

Storm collar required

Top sealing achor plate

Type B vent or Listed Flexible Gas Liner. On outside chimneys Jøtul recommends the use of Type B vent to help keep the gases warm and rising.

max. height 35’ min. height 7’

Always maintain the proper clearance to mantel and trim

Maximum

offset is 4’

Recommended damper sealing plate to seal flue chamber to prevent heat loss

Allagash B-Vent gas stove

WARNING: FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS DIAGRAM OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY.