PREFACE
1.
. Safety
..
This instruments are designed according to the following safety documents:《IEC
61010-1:2001》(Which is :《Measurement, Control and Laboratory Electric Equipments
Safety Requirement》Part 1) and 《IEC 60601 — 1:1988》(Which is:《Electric Apparatus
of Medical Treatment》 Part 1).
2.
. About the Instruments
..
A-100 Series Peltier/Sipper System is an electrical test instruments which is widely
used in the laboratories.
Use Frequency: Intermittence
Excessive Voltage(Current): No
Pollution Class: Class 1
3.
. Symbols
..
Caution, Danger!
Caution, Danger!
Caution, Hot!
Ground
Fuse
Recall, this instrument will be called back by the
appointed Electrical Treatment Department or by the
original Manufacturer when wasted.
Page 6
- 2 -
Series A-100 Peltier/Sipper System
Chapter I Summary
A-100 Series Peltier/Sipper System (A-100: Peltier/Sipper System; A-101: Sipper Unit;
A-102: Ambient Peltier Unit), as a spectrophotometer matching accessories, with high
stability, flexible and accurate. It can be widely used in chemical, pharmaceutical,
biological and chemical, metallurgy, light industry, textiles, materials, environmental
protection, medical laboratories and education sectors. It is a conventional laboratory
preparation of apparatus.
1.
. Working principle and structure
..
Peltier temperature controller using the device as temperature control element. By
controlling the current size to raise or lower the temperature. With a fast response and
accurate temperature control characteristics. Autosampler selected stepper motor driven
vacuum pump drawing samples. With a flow rate of a balanced and accurate
characteristics of injection.
2.
. Main Specifications
..
Specifications for A-100 Series Peltier/Sipper System:
To ensure the best performance, A-100 Series Automatic Peltier/Sipper System has
its special design to prevent the negative influence from environment.
Before installation, please confirm the following conditions:
The best working temperature range is 16-35℃ and the humidity is 45-80%.
Keep it as far as possible away from the strong magnetic or electrical fields or
any electrical device that may generate high-frequency fields.
Set the unit up in an area that is free of dust, corrosive gases and strong
vibrations.
Remove any obstructions or materials that could hinder the flow of air under and
around the instrument.
The power requirement is 220±22V@50±1Hz or 110±11V@60±1 Hz.
Use the appropriate power cord and plug into a grounded outlet.
Be away from direct sunlight
Be away from dust.
2.
. Voltage Confirmation
..
Be sure to set the instrument’s voltage switch at your local power
supply, or severe damage may occur!
3.
. Installation
..
Step 1::::Check the packing list
Unpack the contents; check the materials with the Packing List. Any damage or
Lost found, please contact us or the local dealer.
Step 2:::: Position
Place the instrument on the stable table carefully.
Step 3:::: Install Holder
Open the sample room lid of Spectrophotometer, unscrew the four screws in
conjunction 4-cell holder and the rod, and then remove them, assemble the Constant Temperature Micro Cell Holder in sample room at the same location using the 2
screws as Fig.2-1. Then connect the plug with the power supply.
Note: A101, just use Micro Cell Holder
Page 8
- 4 -
Series A-100 Peltier/Sipper System
Fig. 2-1
Step 4:::: Link the power cord(except A-101)
Make sure the instrument’s power switch is in the Off condition, link the power
cord to the instrument as Fig.2-2
Fig. 2-2
Step 5:::: Link the sample silica gel pipe to spectrophotometer(Except A-102))))
Check again; make sure that the instrument power switch is in the Off condition,
Page 9
- 5 -
link the sample silica gel pipe as Fig.2-3, open the pump holder, insert the silica gel
pipe like No.1 in the Fig.2-3, then lock the holder like No.2. Connect the Right gel pipe
with the Flow Through Cell through the hole of No.3, and connect the Left gel pipe
with the Flow Through Cell through the hole of No.4. Screw the shaft accordingly like
Fig.2-4.
图 2-3
Fig.2-4
Step 1:::: Install Power Cord
Check instrument to make sure the power switch is in Off condition. Connect the
two sides of power line to instrument and the power outlet.
Step 2:::: Connected to power
Check again and then switch on, the instrument can be used after self-checking.
Page 10
- 6 -
Series A-100 Peltier/Sipper System
Page 11
- 7 -
Chapter III Introduction of the Instrument
1.
. Introduction
..
Appearance of the instrument (Fig.3-1):
1 — Operation Panel
2 — Pump
3 — Temperature Control Port
4 — Power Socket
5 — Power Switch
2.
. Operation Panel
..
Operation panel of Series A-100( Fig.3-2):
Fig.3-1
Page 12
- 8 -
Series A-100 Peltier/Sipper System
1 — LCD
2 — Keypad
3.
. Keypad Description
..
Fig.3-2
Start/Stop
Set Parameter
Cancel operation
,Scroll the menu or data
Page 13
- 9 -
Chapter IV Instrument Operation
1.
. Software Structure
..
Software structure of Series (Fig.4-1)
Main Menu
2.
. Basic Operation
..
1)
1) Temperature Control
1)1)
Setting Interface
Fig.4-1
Temperature Switch
Temperature Setting
Sipper Setting
In the main menu, press to enter interface(Fig.4-2), press 、
to choose ”Set Heater”, then press to enter interface(Fig.4-3),
press 、 to choose “On” to enter temperature control function, then
press to confirm and return;
Fig. 4-2
Fig.4-3
Page 14
- 10 -
Series A-100 Peltier/Sipper System
Press 、 to choose “Set Temp”. Then press to enter “Set
Temp” (Fig.4-4),press 、 to add/reduce temperature,press
to confirm and return.
Fig.4-4
Press to return Main Menu, the instrument will start testing after transferred to the
set temperature.
2)
2) Automatic Sipper
2)2)
In the main menu, press to enter; press 、 to choose“Set
Sipper” then press to set sipper speed(Fig.4-5), press 、
to choose relative speed, press to confirm and return.
Fig.4-5
Press to return main menu, press to start sipper, press
again to stop.
Page 15
- 11 -
Chapter V Instrument Maintenance
To keep the instrument work in good condition, constant maintain is needed.
1.
. Daily Maintain
..
1)
1) Surface Clean
1)1)
The cover of the instrument is with paint. Please use wet towel to wipe off the drips
on the surface immediately. Organic solution is forbidden to be used to clean the
cover. Please wipe off the dirt on the cover timely.
2)
2) Clean the Silica Gel Pipe
2)2)
Clean the sipper silica gel pipe after testing or changing the sample solution to
avoid being corroded or polluted.
Constant Temperature and Automatic Sipper System 1set
Constant Temperature Sample Holder 1pc
Silica Gel Pipe 1pc
Connection Line 1pc
Power Cord 1pc
User’s Manual 1set
2) A-101: Sipper Unit;
Constant Temperature and Automatic Sipper System 1set
Silica Gel Pipe 1pc
Power Cord 1pc
User’s Manual 1set
3) A-102: Ambient Peltier Unit)
Constant Temperature System 1set
Constant Temperature Sample Holder 1pc
Connection Line 1pc
Power Cord 1pc
User’s Manual 1set