Ipso WE73, WE95 User manual

4.8 (5)

IPSO - LSG n.v

Instruction manual

WE 73, WE 95

WE 132, WE 165

With electronical timer µ20

Technical specifications Installation instructions Operating instructions Maintenance

Nieuwstraat 146 - B-8560 Wevelgem (België)

Tel. 056/41 20 54 - Fax 056/41 86 74

Contents

1

General safety instructions ............................................................

3

2

Technical data and dimensions .....................................................

4

 

Technical data .................................................................................

4

 

Dimensions......................................................................................

6

3

Installation and connection ............................................................

8

 

Ground ............................................................................................

8

 

Anchoring ........................................................................................

8

 

Water connection ............................................................................

8

 

Water drain......................................................................................

9

 

Main power connection ...................................................................

9

 

Liquid soap connection....................................................................

10

 

Connection of a central operating panel for coinmachines ............

11

 

Steam connection............................................................................

12

4

Operating instructions ...................................................................

13

 

Machine with start button ...............................................................

13

 

Machine with coin or token operation..............................................

21

5

Standard programs ........................................................................

27

6

Technical remarks ..........................................................................

28

 

Internal connection of the electrical heating....................................

28

 

Internal connections of the motors ..................................................

29

 

Thermo-magnetic motor protection .................................................

30

 

Error messages...............................................................................

30

7

Maintenance of the machine ..........................................................

32

Code: 249/00162/00

14/10/2005

Content

1

General safety instructions

Ignoring any of the safety instructions can cause serious personal injury and can also cause damage to the linen or the machine

Read the installation and instruction manual carefully before connecting the machine.

It is recommended that the machine be installed by qualified technicians.

The machine should be installed according to the installation instructions. (See chapter 4)

The machine should be grounded according to the instructions in order to eliminate the risk of electrocution.

Do not expose the machine to high humidity or extreme high or low temperatures.

Cut off all main water inlets, steam and electrical supplies at the end of each operating day.

Before starting repairs or maintenance, shut off all power and water supplies.

To prevent fire and explosion:

Keep the area around the machine free from inflammable or combustible products.

Do not put fabrics that are treated with inflammable products into the machine. These fabrics should be hand-washed or air-dried first.

Always carefully read and follow the instructions on the packing of detergents. Store these products out of the reach of children.

Always take into account the instructions on the labels of clothes.

Never allow children to play in the surroundings of a machine.

Remark:

These instructions surely cannot prevent all risks of accidents. It is up to the user to act with the utmost precaution.

Do not hesitate to contact the dealer in case of a problem.

3

2

Technical data and dimensions

Technical data

 

 

WE 73

WE 95

 

 

 

 

Capacity (dry weight)

 

 

 

1/11

 

6,6 kg

8,6 kg

1/10

 

7,3 kg

9,5 kg

1/9

 

8,1 kg

10,5 kg

 

 

 

 

Cylinder

 

 

 

Diameter

 

530 mm

530 mm

Depth

 

345 mm

440 mm

Volume

 

73 Lit.

95 Lit.

 

 

 

 

Cabinet

 

 

 

Height

 

1005 mm

1110 mm

Width

 

660 mm

660 mm

Depth

 

670 mm

770 mm

 

 

 

 

Front loading

 

 

 

Diameter door opening

 

300 mm

300 mm

Door height

 

360 mm

455 mm

To center

 

510 mm

605 mm

 

 

 

 

Speed

 

 

 

Wash

 

50 rpm

50 rpm

Spin

 

500 rpm

500 rpm

 

 

 

 

G-force

 

 

 

Spin

 

 

74

 

 

 

 

Motor(3 phase)

 

 

 

Wash 18p. 290rpm

 

120 W

120 W

Spin 2p. 2900 rpm

 

370 W

550 W

 

 

 

 

Drain valve

 

 

 

Depend-O-Drain

 

 

6/4"

 

 

 

 

Water supply

 

 

 

Hard, soft, warm water and cool-down

 

3/4"

 

 

 

 

Steam connection

 

 

 

Steam connection

 

 

3/8"

 

 

 

 

Heating

 

 

 

Electrical 220/380 V

 

4,2/6/9 kw

 

Electrical 380 V

 

12 kw

 

Steam

 

X

 

Warm water (without additional heating)

X

 

Warm water (with additional heating)

X

 

 

 

 

 

Packing dimensions

 

 

 

(H x W x D)

1140x732x832mm (WE73)

 

 

1230x732x950mm (WE95)

 

 

 

 

 

Weight

 

 

 

Net

 

170 kg

178 kg

Gross

 

225 kg

230 kg

4

2

 

 

 

WE 132

WE 165

 

 

 

 

 

 

 

Capacity (dry weight)

 

 

 

 

1/11

 

12 kg

15 kg

1/10

 

13,2 kg

16,5 kg

1/9

 

14,5 kg

18,3 kg

 

 

 

 

 

 

 

Cylinder

 

 

 

 

 

Diameter

 

650 mm

650 mm

 

Depth

 

400 mm

500 mm

 

Volume

 

132 Lit.

165 Lit.

 

 

 

 

 

 

 

Cabinet

 

 

 

 

 

Height

 

1170 mm

1170 mm

 

Width

 

780 mm

780 mm

 

Depth

 

760 mm

860 mm

 

 

 

 

 

 

 

Front loading

 

 

 

 

 

Diameter door opening

 

300 mm

300 mm

 

Door height

 

465 mm

465 mm

 

To center

 

615 mm

615 mm

 

 

 

 

 

 

 

Speed

 

 

 

 

 

Wash

 

50 rpm

50 rpm

 

Spin

 

500 rpm

500 rpm

 

 

 

 

 

 

 

G-force

 

 

 

 

 

Spin

 

 

88

 

 

 

 

 

 

 

 

Motor(3 phase)

 

 

 

 

 

Wash 18p. 290rpm

 

220 W

280 W

 

Spin 2p. 2900 rpm

 

1100 W

1300 W

 

 

 

 

 

 

 

Drain valve

 

 

 

 

 

Depend-O-Drain

 

 

6/4"

 

 

 

 

 

 

 

 

Water supply

 

 

 

 

 

Hard, soft, warm water and cool-down

 

3/4"

 

 

 

 

 

 

 

 

Steam connection

 

 

 

 

 

Steam connection

 

 

3/8"

 

 

 

 

 

 

 

 

Heating

 

 

 

 

 

Electrical 220/380 V

 

12/15/18 kw

 

 

 

Electrical 380 V

 

21/24 kw

 

 

 

Steam

 

X

 

 

 

Warm water (without additional heating)

X

 

 

 

Warm water (with additional heating)

X

 

 

 

 

 

 

 

 

 

Packing dimensions

 

 

 

 

 

(H x W x D)

1310x850x922mm (WE132)

 

 

1310x850x1022mm (WE165)

 

 

 

 

 

 

 

Weight

 

 

 

 

 

Net

 

235 kg

245 kg

 

Gross

 

290 kg

315 kg

5

Ipso WE73, WE95 User manual

Dimensions

WE 73/95

 

 

 

 

 

 

 

 

 

 

 

 

=1130

 

 

 

 

1103

 

 

- WE95

WE95 =

 

= 1035

1008 -

 

 

WE73

WE73 =

 

 

 

 

 

 

 

WE73 = 350 - WE95 = 470

55 550 55

660

390

 

 

 

310

 

 

 

230

 

 

 

150

 

 

140.5

A

 

 

F

C

D

E

G

 

 

 

B

 

H

I

 

 

WE73 = 892 - WE95 = 987

WE73= 810.5 - WE95 = 905.5

375

L

WE73= 856.5 - WE95 = 951.5

 

 

 

 

 

 

- WE95 =

 

K

 

 

= 280

 

56

 

 

WE73

 

 

 

 

200

 

175

2

61

220

24

WE73 = 86 - WE95 = 186

560

WE73 = 670 - WE95 = 770

WE73 = 728 - WE95 = 828

A. Ventilation soap dispenser

B. Liquid soap connetions

C. Hard water connections 3/4"

D. Warm water connections 3/4"

E. Soft water connections 3/4"

F. Connections clamps

G.Electrical connections

H.Emergency button

I. Ventilation tub

K. Drain valve

L. Steam connections

6

Dimensions

WE 132 / 165

1198.5

 

 

1171

455

70 640 70

780

235.5

 

 

157.5

 

 

79.5

 

155

 

 

A

 

 

 

D

F

 

B

G

 

 

C

E

 

 

H

I

1042

931

902

 

1000.5

 

 

 

L

 

 

 

 

K

 

 

 

 

208

102

 

 

 

 

2

65.5

220

25 WE132 = 670 - WE165 = 770 68

WE132 = 763 - WE165 = 863

WE132 = 820 - WE165 = 920

A. Ventilation soap dispenser

B. Liquid soap connetions

C. Hard water connections 3/4"

D. Warm water connections 3/4"

E. Soft water connections 3/4"

F. Connections clamps

G.Electrical connections

H.Emergency button

I. Ventilation tub

K. Drain valve

L. Steam connections

7

3

Installation and connection

Surface

The machine must be securely fixed on a flat surface (metal base, concrete or solid ground). The anchoring is to be done on the provided places (A) in the base. (See Dimensions 2)

The machine must be placed entirely level. For easy maintenance it is recommended to keep a minimal distance of 600 mm between the wall and the back of the machine.

If several machines are placed next to each another, there should be a minimal distance of 30 mm between each machine.

Anchoring

D

C

E

F

D

C

G

B

A

D

E

C

B

A

On a metal base

The machines must be fixed on a metal base which is securely anchored on a concrete base.

A:Bolt M12 (WE73/95), M16 (WE132/165)

B:Concrete base (WE73: 20cm, WE95: 30cm, WE132/165: 40cm)

C:Washer 40x17x4

D:Nut M12 (WE73/95), M16 (WE132/165)

E:Base of the machine

F:Metal base

Directly on the ground

The machine must be anchored directly on a concrete base.

A:Bolt M12 (WE73/95), M16 (WE132/165)

B:Concrete base (WE73: 20cm, WE95: 30cm, WE132/165: 40cm)

C:Washer 40x17x4

Water connection

The machine is delivered with hoses with 3/4" connections. These hoses fit the water inlet valves of the machine and the main water inlet taps. To ensure the optimal functioning of the water inlet valves, the water pressure on the inlet should be between 0,5 and 10 kg/cm² (7 and 145 psi). If the pressure is too low, the cycle time will increase considerably.

In case of boiler fed machines, a minimum of hot water of 90°C should be available:

For the WE73: 65 l. WE132: 120l. For the WE95: 80 l. WE165: 140l.

8

3

Water drain

The machine is equipped with a drain valve with 6/4" outer diameter (50 mm). This drain valve should be connected to the drain by means of the drain elbow which is delivered with the machine.

The diameter of the main drain should be adapted to the water flow and the number of machines. It should be sufficient to handle at least 80L/min. per machine.

It is necessary to connect the main drain at least on one side to an open air-brake to allow ventilation.

Main power connection

Power of the breaker plugs:

Remove the cover plate at the back of the machine. (See dimensions (E)).

Connect the power cable to the connectors.

220V 3AC

220V 3 phase (3AC) should be connected to the connectors “L1,L2,L3”.

The green/yellow grounding clamp has to be connected to the grounding wire “PE”.

380 V 3AC + N

380 V 3 phase (3AC + N) has to be connected to the connectors

“L1,L2,L3”, the blue neutral to the “N” connector.

The green/yellow grounding clamp has to be connected to the grounding wire “PE”.

After connection, check the spin direction. The cylinder must spin in the direction of the arrow, showed on the sticker on the door window (clockwise).

A wrong spin direction can damage the motor, and can also cause water to spurt from the soap dispenser.

In case of wrong spin direction: switch the terminal clamps of the

motor circuit “R” and “S” of the connecting cable.

machine with steam heating or boiler fed machines without additional electrical heating

220V 3AC

380V 3AC + N

16 A

16 A

machine with electrical heating

Heating:

220V 3AC

380V 3AC + N

4,2 kw

16A

16A

6 kw

16A

16A

12 kW

40 A

20 A

15 kW

50 A

25 A

18 kW

50 A

32 A

21 kW

----

40 A

24 kW

----

40 A

9

Loading...
+ 23 hidden pages