Invacare MA60, MA65 User Manual

Invacare® mic roAIR® MA60 & MA65 A lterna t ing Pre s sure Ma t tresses
MA 65
with raised side rails (RSR)
shown on CS7™ bed
with ThinkSoft® Positioning Device
These two (2) microAIR® alternating pressure mattress models reduce interface pressure to aid in the prevention
and the treatment of Stage I to Stage IV pressure ulcers with a state-of-the-art 50 LPM compressor that inflates
the mattress within 5-10 minutes and provides faster, more efficient and complete therapy cycles.
Invacare
Female 5' 5" 110 lbs.
Friday, September 18, 2009 3:42:49.484 PM
®
microAIR® MA60 & MA65 Alternating Pressure Mattresses
Body Interface Pressure Imaging Test
MA65
Test demonstrates contact measurement between key pressure points. Subject is 5'5" female, 110 lbs Simulation. Individual resident results will vary.
100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
User-Friendly Control Unit
Lightweight unit with LED display and up down ar rows for easy adjustment of comfor t and ther apy settings
90 degree Hose Quick-Connect
Simplifies set-up with one motion
Quick-Connect Air Cells
Quick-connect air cells allow easy replacement of individual cells if necessary
On-Demand Low Air Loss
When activated at the push of a button, air is released inside the MA65 mattress to keep the mattress cooler and dryer for the resident
Specif i cation s
• Resident Risk Level : Medium-High
• Cover : Dual-layered, quilted,
anti-microbial, fluid resistant vapor-permeable cover protects internal cells. Bottom cover is1000 Denier nylon
MA60 MA65 MA65B42 MA65B48
Width 36" 36" 42" 48"
Depth 10" 10" 10" 10"
Weight Capacity 350 lbs. 350 lbs 1,000 lbs 1,000 lbs
Available with Raised Side Rails (RSR) * * n/a n/a
Invacare Continuing Care, Inc. ww w.invacare -ccg.com info_iccg
• Limited Warranty : 1 year on mattress, 2 years on power unit
• Power Unit : 50 LPM
• Internal cells : 70 Denier
urethane coated nylon
Feature s
Efficient real-time monitoring for correct pressu re relief
2” safety foam base adds safety and comfort
CPR release built into mattress
Built-in carr ying straps
for easy transportat ion
50 LPM compressor quickly inflates mattress
Power outage safety with mattress hose is connected to the compressor
Bari a t r ic
Settings retained during a power outage will resume once power is restored
Manual fowler to prevent accidental bottoming out
Energy-saving compressor turns “off” when not needed during pressure maintenance modes
MA65 includes on-demand low air loss
@
invaca re.com
USA
One Invacare Way Elyria, Ohio 44035 USA 800-668-2337
Canada
994 Hargrieve Road London, Ontario N6E 1P5 Canada 800-668-2337
For more information, contact your Invacare Continuing Care Sales Representative at 1.800.668.2337 or visit www.invacare-ccg.com.
© 2009 Invacare Continuing Care, Inc. All rights reserved. Trademarks are identified by the symbols ™ and ®. All trademarks are owned by or licensed to Invacare Corporation unless otherwise noted. Specifications are subject to change without notification.
Form 08.67.9/09
Loading...