Worldwide Headquarters
6001 36th Ave.W.
Everett, WA 98203
U.S.A.
www.intermec.com
The information contained herein is provided solely for the purpose of allowing customers to
operate and service Intermec-manufactured equipment and is not to be released, reproduced, or
used for any other purpose without written permission of Intermec Technologies Corporation.
Information and specifications contained in this document are subject to change without prior
notice and do not represent a commitment on the part of Intermec Technologies Corporation.
The word Intermec, the Intermec logo, Norand, ArciTech, Beverage Routebook, CrossBar,
dcBrowser, Duratherm, EasyADC, EasyCoder, EasySet, Fingerprint, i-gistics, INCA (under license),
Intellitag, Intellitag Gen2, JANUS, LabelShop, MobileLAN, Picolink, Ready-to-Work, RoutePower,
Sabre, ScanPlus, ShopScan, Smart Mobile Computing, SmartSystems, TE 2000, Trakker Antares,
and Vista Powered are either trademarks or registered trademarks of Intermec Technologies
Corporation.
There are U.S. and foreign patents as well as U.S. and foreign patents pending.
iiApriva BT200-T Smart Card Reader User’s Guide
Page 3
Document Change Record
This page records changes to this document. The document was
originally released as Revision 001.
Version
Number
0049/2010Updated procedures on how to connect the
0039/2009Updated procedures on how to install Odyssey
0027/2009Updated procedures on how to connect the
DateDescription of Change
Apriva BT200-T to the CN4G and CN4eG.
Access Client and Fortress Security Client onto
the CK61G.
The Apriva BT200-T Bluetooth Smart Card Reader (SCR) works with
the CN4G, CN4eG, or CK61G Mobile Computer to enable data
sensitive enterprises to have a high level of security for wireless
communication. The SCR provides users with strong identification
and authentication using hard token certificate and private key
policies.
Understanding the Power Button and LEDs
The SCR has a Power button and two status LEDs to tell you the
status of the smart card reader.
Power button
Status LEDs
Apriva BT200-T Power Button and Status LEDs
Understanding the Status LEDs
ActionLED StatusDescription
You power on the
SCR.
You first insert a
common access
card (initial four
seconds).
Solid green for a
few seconds
Solid redYou need to charge the battery.
No LEDThe battery is completely discharged.
Solid greenBattery is over 75% charged and is ready
Flashing greenBattery has between 25% and 75%
Solid redBattery has less that 25% charge. You
The SCR has a good charge.
for operation.
charged capacity.
need to charge the battery.
Apriva BT200-T Smart Card Reader User’s Guide7
Page 8
Understanding the Status LEDs (continued)
ActionLED StatusDescription
Common access
card has been
inserted for more
than four
seconds.
You connect the
USB cable.
You remove the
Smart card or
charge cable.
Flashing green
or red every one
second.
Solid greenSCR is being charged, and cannot be
Green and red
flash once
If the LED is not blinking after you press the Power button, you need
to charge the SCR for 30 or more minutes. After 30 minutes, you need
to check the status of the indicators by inserting a smart card.
Checking and Charging the Battery
Connection between the mobile
computer and the SCR has been
established, and the SCR is ready for
operation.
used.
Note: You can use the SCR when you
are charging with the wall charger, but
you cannot use the SCR when a USB
connection is the main power source.
When you press the Power button, the
LED flashes to provide a visual clue
that the SCR has been powered off.
The SCR takes approximately 3 hours to charge its internal battery.
You can use the wall charger or a USB cable to charge the SCR.
To check the status of the battery
•Press the Power button and observe the status LEDs. For more
information on the status LEDs, see “Understanding the Power
Button and LEDs” on page 7.
To charge the battery using the wall charger
1 Attach the SCR to the wall charger.
2 Insert the wall charger into an electrical outlet.
3 The green LED turns on indicating that the SCR is charged.
8Apriva BT200-T Smart Card Reader User’s Guide
Page 9
To charge the battery using a USB cable
1 Connect the USB adapter to the USB cable, then connect the USB
adapter to the SCR to the port labeled PC.
2 Connect the other end of the USB cable to your notebook or
desktop PC. The green LED turns on indicating that the SCR is
charged.
While charging using the USB cable, all smart card operations are
disabled.
Note: If the battery is discharged to the point where you cannot turn
on the SCR, you need to charge, the SCR for 20 to 30 minutes. Once
the SCR has been charged for that amount of time, turn the SCR off
and on again to finish charging.
Installing and Pairing the SCR
There are five important steps to follow before you can use the
SCR.
To install and pair the SCR
1 For the CK61G, upgrade the operating system (OS) and
SmartSystems Platform Bundle (SSPB). For more information, see
the CK61 Mobile Computer User’s Manual.
2 Load the SCR software onto the mobile computer.
3 Pair the SCR to the mobile computer.
4 Install security.
5 Install the AprivaGuard software.
Use the following sections to help you install and pair the SCR to your
mobile computer.
Apriva BT200-T Smart Card Reader User’s Guide9
Page 10
Loading the SCR Software
Use this section to learn how to load the SCR software onto your
mobile computer.
To load the SCR software
1 Tap the iConnect icon. The iConnect menu appears.
2 If you are installing the SCR software onto the CK61G:
aSelect Enable and make sure that Assured Radio
Deactivation is not checked. The mobile computer restarts
with Assured Radio Deactivation turned off.
bTap OK on the Assured Radio Deactivation screen.
cTap Start > Settings > the Connections tab > Bluetooth. The
Bluetooth Settings screen appears.
dSelect the Turn on Bluetooth check box to enable Bluetooth.
eTap OK to exit the Bluetooth Settings screen.
10Apriva BT200-T Smart Card Reader User’s Guide
Page 11
If you are installing the SCR software onto the CN4G or CN4eG,
continue to the next step.
3 Establish an ActiveSync connection between your mobile
computer and your desktop PC by placing the mobile computer
into communications dock. For more information, see the mobile
computer user’s guide.
4 Once a connection has been established, the Microsoft ActiveSync
screen appears on your PC. Click the Explore button and browse
to the \My Documents folder.
5 Download the Apriva software from www.intermec.com/ait and
extract all of the files into the \My Documents folder.
6 Remove the mobile computer from the communications dock and
tap Programs > File Explorer on your mobile computer. The File
Explorer screen appears.
Apriva BT200-T Smart Card Reader User’s Guide11
Page 12
7 Install the SCR software and pair the SCR with your mobile
Pairing the SCR
Use this section to learn how to pair the SCR with your mobile
computer. For security purposes, you must pair the SCR using a USB
cable. After the initial pairing, you do not need to pair the SCR with a
USB cable again.
To pair the SCR
1 Browse to the \My Documents folder and tap
2 Place the mobile computer into the communications dock.
computer. For help, see the next section.
AprivaSmartCardDriver.SWM5PPCxxxx.cab where xxxx is the
version number. The .cab file is installed onto your mobile
computer and cold boots your device.
12Apriva BT200-T Smart Card Reader User’s Guide
Page 13
3 Connect a USB cable to your communications dock and to the
USB adapter
USB cable
Power button
Status LEDs
SCR using the USB adapter provided. Note that you have to
connect it to the port labeled PDA.
Note: Use the cable that you connected to your PC. The cable that
comes with the SCR is a charge only cable.
The SCR Connected to the CK61G Communications Dock.
4 Turn the smart card reader on by pressing the Power button. The
green LED on the card reader blinks once every second to indicate
that there is a USB connection present.
Apriva BT200-T Smart Card Reader User’s Guide13
Page 14
Note: If the green LED blinks once every four seconds, the SCR is
powered on, but there is no USB connection. Repeat Step 3 to pair
the SCR. For more information about the LED status see,
“Understanding the Power Button and LEDs” on page 7.
5 On the mobile computer, tap Start > Settings > System > Apriva
Reader. The Apriva Reader screen appears.
6 Pair the SCR and the mobile computer by selecting the USB
option and tapping the Pair button.
7 Tap Test Connection to verify that the mobile computer is
communicating with the smart card reader.
8 Tap the Version tab. The Version screen appears.
9 Tap the Update button.
10 Select AprivaReaderxxxx.bin where xxxx is the version number.
The smart card reader begins the firmware update process.
11 Tap the Details tab and the Verify Signatures button to verify the
digital signatures of the firmware.
12 Tap the Connection tab, and select the Bluetooth option.
13 Remove the USB cable from the SCR, and turn the power to the
SCR back on by pressing the Power button.
14Apriva BT200-T Smart Card Reader User’s Guide
Page 15
14 Tap Test Connection to verify that the SCR is communicating
with the mobile computer.
Note: Pairing the smart card reader only needs to be performed
once. To select a connection, tap the USB or Bluetooth option
when the SCR and the mobile computer are connected to the
communications dock.
15 Tap OK to close the Apriva Reader application.
16 Browse to the \My Documents folder and tap
Semtek Innovative Solutions CAC Reader.cab. The .cab file is
installed onto your mobile computer.
17 Go to File Explorer, browse to the \My Documents folder, and
tap AprivaCSPware.SWM5PPC.cab. The .cab file is installed and
your mobile computer reboots.
18 (Optional) If you need access to the Department of Defense web
site, go to File Explorer, browse to the \My Documents folder,
and tap InstallRoot_WinMobile6_313.cab. The .cab file is
installed onto your mobile computer.
19 If you are installing the SCR software onto the CK61G, you need
to install the following files in the \My Documents folder:
•Intermec Funk_AprivaConfig.cab
•SR08100900_RTC_CK3WM61_ALL.cab
•SR10052500_FUNK_WM61_ALL.cab
20 Install security. For help, see the next section.
Apriva BT200-T Smart Card Reader User’s Guide15
Page 16
Installing Security
You can choose to install two types of security onto the mobile
computer:
•Odyssey Access Client
•Fortress Secure Client
The Odyssey Access Client and Fortress Secure Client both provide a
high level of security over your WLAN. These clients protects the
authentication and connection of the WLAN users and devices,
ensuring that only authorized users connect, that login credentials are
not compromised, and that both network and data privacy will be
maintained over the wireless link.
For help on selecting a client, contact your local Intermec
representative.
The CN4G and CN4eG comes with Odyssey Access Client already
loaded. To use the client on your CN4G and CN4eG, you must
purchase a user license, and activate it. For help on activating the
client, see the CN4G and CN4eG Odyssey Access Client Installation
Instructions.
To install Fortress Secure Client
1 Go to File Explorer, browse to the \My Documents folder, and tap
WZeroConfigEnable.cab. Microsoft Zero Config is installed.
2 Make sure that the mobile computer can successfully associate
with an access point by tapping the iConnect icon > Status >
Wireless > the Advanced button. The ISpyWiFi utility appears
and shows whether you can associate your mobile computer with
an access point.
3 Use the iConnect application to configure the IP address, network
mask, and SSID.
4 Download the Fortress Secure Client Installation Guide from the
Intermec AIT web site, and follow the directions to install and
configure the Fortress Secure Client.
5 Install the AprivaGuard software. For help, see “Installing the
AprivaGuard Software” on page 17.
16Apriva BT200-T Smart Card Reader User’s Guide
Page 17
To install Odyssey Access Client for the CK61
1 Go to File Explorer and browse to the \My Documents folder,
and tap Intermec Funk_Apriva.cab file. The .cab file is installed
on your mobile computer.
2 Tap WZeroConfigEnable.cab. Microsoft Zero Config is installed
on your mobile computer.
3 Purchase and download the Odyssey Access Client. For more
information, go to www.juniper.net.
4 Download the Odyssey Access Client Installation Guide from the
Intermec AIT web site, and follow the directions to install and
configure the Odyssey Access Client.
5 Install the AprivaGuard software. For help, see “Installing the
AprivaGuard Software” on page 17.
Installing the AprivaGuard Software
Install the AprivaGuard software license onto your mobile computer
to enable PKI authentication and validation for the mobile computer
and a given application.
Note: Set the correct date and time, and install any other software
applications you have before installing AprivaGuard. Once
AprivaGuard is installed, you cannot make any changes to your
mobile computers.
To install the AprivaGuard software
•Browse to the \My Documents folder, and tap
AprivaGuard.WM5PPC.cab file. AprivaGuard installs onto your
mobile computer.
Apriva BT200-T Smart Card Reader User’s Guide17
Page 18
18Apriva BT200-T Smart Card Reader User’s Guide
Page 19
Page 20
Worldwide Headquarters
6001 36th Avenue West
Everett, Washington 98203
U.S.A.