Intel 410T User Manual

English
Français Italiano Deutsch Español
Intel® Express 410T Standalone Switch
Quick Start and User Guide
Year 2000 Capable
An Intel product, when used in accordance with its associated documentation, is “Year 2000 Capable” when, upon installation, it accurately stores, displays, processes, provides, and/or receives date data from, into, and between the twentieth and twenty-first centuries, including leap year calculations, provided that all other technology used in combination with said product properly exchanges date data with it.
Copyright © 1999, Intel Corporation. All rights reserved. Intel Corporation, 5200 NE Elam Young Parkway, Hillsboro OR 97124-6497
Intel Corporation assumes no responsibility for errors or omissions in this manual. Nor does Intel make any commitment to update the information contained herein.
* Other product and corporate names may be trademarks of other companies and are used only for explanation and
to the owners’ benefit, without intent to infringe.
First Edition May 1999 740604-001
Contents
Quick Starts 2
English...........................................................................................2
Chinese ..........................................................................................4
Korean ........................................................................................... 6
French............................................................................................ 8
Italian.............................................................................................10
German ..........................................................................................12
Spanish .......................................................................................... 14
User Guide 17
Understanding 410T Switches.......................................................18
Port LEDs...............................................................................18
Status LED ............................................................................. 18
Crossover Button....................................................................18
Local Management ........................................................................19
Overview ................................................................................19
Navigation ..............................................................................19
Functions ................................................................................ 20
Connecting to Devices ..................................................................21
Connection Guidelines ........................................................... 21
Workgroup Example......................................................................22
Cabling Devices ............................................................................23
Media Requirements .............................................................. 23
Straight-through vs. Crossover Cables...................................23
Testing a cable........................................................................24
FAQs/Troubleshooting .................................................................. 25
Regulatory Information and Warnings .......................................... 26
Limited Hardware Warranty..........................................................29
Intel Customer Support Inside back cover
1
Quick Start
English
Install the Switch
1
• Remove the switch and parts from the box.
• Attach the enclosed brackets if you plan to mount the switch in a rack.
• Install the Intel® Express 410T Standalone Switch in a rack or on a shelf.
• Plug in the power cord.
Connect
2
the Devices
• All ports automatically detect the speed and duplex-mode of any connected device.
• Connect PCs and print servers to the switch with straight-through cables.
Rack: Use the three small screws to attach the brackets to the switch.
®
Intel
Express 410T Standalone Switch
M D
I /
1
M D
I
­X
2
3
4
5
6
7
8
9
1 0
1 1
1 2
1 3
1 4
1 5
L e
ft
1 6
L
in
k =
S o
l id
G
re en
A
c t
iv i
t y =
B lin
k
i n
g
C
G o ll
r
is
ee i o
n
n
= B
lin
k in
g
O
ra
n g
e
R ig
h
t
1
0 M
b
p s =
S
o lid
O
1
r
0
a
0
n
M
g
e
b p
s = O
ff
S ta
t u
s
Shelf: Peel off the protective backing and attach the rubber feet to the switch.
From To
straight-through
Switch PC/Server
Switch Print Server
2
• Use a crossover cable to connect a switch to another switch or hub.
• Use a straight-through cable to connect to another switch or hub when port 1 is set to MDI.
• Use only CAT 5 UTP cable to connect 100Mbps devices. To connect 10Mbps devices, use CAT 3, 4, or 5 UTP cable.
Check the
3
Connections
• Check the port LEDs to confirm the link status.
• A solid green LED (on the left) indicates a valid link.
crossover
Switch Hub or Switch
straight-through
when port 1 set to MDI
Switch Hub or Switch
Left (Green/Orange)
Right (Orange)
Solid Green = Link Blinking Green = Activity Blinking Orange = Collision
5678
10/100
10/100
Off = 100Mbps Solid = 10Mbps
Optional Information
o
How to Change Port 1
4
5
from MDI-X to MDI
• All ports on the switch are MDI-X. Press the MDI/MDI-X button to change Port 1 to MDI so you can connect to another switch or hub using a straight­through cable.
Access the Configuration Screen
• Connect your PC to the Management module’s serial port using the null-modem cable (included).
Intel® Express 410T Standal
MDI
MDI-X
MDI/MDI-X button
1234
MDI
MDI-X
English
• Set a VT100-compatible terminalemula­tion program (such as HyperTerminal*) to these parameters:
- 9600 baud - 8 data bits
- No parity - 1 stop bit
- No flow control
Press E to connect to the Configura­tion screen.
• Navigate the menus with these keys:
T Move to next item.
B Move to previous item.
z Toggle options within a field. c + S Save changes to configuration. c + R Repaint the screen.
• <Auto> is the default setting for the ports. You only need to configure the port settings if you are having difficulty connecting to a device.
Configuration Screen: Items surrounded by angle brackets < > indicate a toggle field. Use the z to toggle selections.
Speed Auto = all port settings are
automatically negotiated. 100 = port set to 100Mbps. 10 = port set to 10Mbps.
Duplex Half = port set to half duplex.
Full = port set to full duplex. – = port set to auto mode.
Flow enable = Flow control is enabled in full Control duplex mode. Back pressure is
enabled in half duplex mode. disable = flow control is off. – = port set to auto mode.
3
kable Hub
1
( Rack )
( switch )
Intel® Express 410T Standalone Switch
2
PC
1 MDI
CAT 5 UTP 100 Mbps 10 Mbps
CAT 3 4 5 UTP
®
Intel
Express 410T Standalone Switch
M D
I/
1
M D
I­X
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Left
16
Li
n
k =
S o
lid
G
r e e
A
n c t
iv i
ty =
Bl
i nk
i n
g
C
G o l
li
r e
s
e
io
n
n
= B
l in
k in
g
O r a
n g
e
Righ
t
10
M
b
p s =
S
o li
d O
10
r
a
0
n
M
g
e
b p
s =
O ff
St
at us
( Shelf )
( switch )
( Switch )
( Switch )
( Switch ) ( Hub or Switch )
1 MDI
( Switch ) ( Hub or Switch )
PC/
10/100
10/100
4
3
LED
• LED
= =
=
= 100 Mbps
= 10 Mbps
5678
o
4
5
1 MDI-X
MDI
MDI-X MDI/MDI-X 1
MDI
PC
VT100
*
- 9600 - 8
- - 1
-
E
MDI
MDI-X
MDI/MDI-X
z
Intel® Express 410T Standal
1234
MDI
MDI-X
< >
T
B
z c + S c + R
•< >
(Auto) =
(Speed)
100 = 100 Mbps 10 = 10 Mbps
(Half) =
(Duplex) (Full) =
– =
(Enable) =
(Flow Control)
(Disable) =
– =
5
9
1
®
I
n
te
l
E
x
p
r
e
s
s
4
1
0
T
S
ta
n
d
a
l
o
n
e
S
w
itc
M D
I
/ M D
I
-
®
h
1
X
2
3
4
5
6
7
8
9
10
11
12
13
14
15
L e
f t
16
L
i n
k =
S
o l i d
G r
e e
A
n c t
i v i t
y =
B
l i n k
i n g
C
o
G l
l
r
i
e
s
e
i
o
n
n
=
B l i n
k i n
g
O r
a n g
e
R i
g h
t
1
0 M
b
p s
= S
o l i
d O
1
0
r
a 0
n
M
g
b
e
p
s =
O f f
S t
a t u
s
2
3
10/100
10/100
Module A
ackable Hub
45678
6
S
4
5
Intel® Express 410T Standalone
MDI
12345
MDI-X
MDI
MDI-X
E
z
T
B
z
c + S
c + R
7
9
Démarrage rapide
Installez le switch
1
• Retirez le switch et les pièces de la boîte.
• Fixez les supports livrés avec l’appareil si vous envisagez de le monter dans une armoire.
• Installez Intel® Express 410T Standalone Switch dans une armoire ou sur une étagère.
M
D
I /
M
D
I­X
®
Intel
Express 410T Standalone Switch
1
2
3
4
5
Armoire : utilisez trois petites vis pour fixer les supports au switch.
6
7
8
9
1
0
1
1
1
2
1
3
1
4
1
5
L
e f
t
1
6
L
in k
= S
o
li d G
r e
e
A
n c t iv
it y =
B
l in
k in
g
C
o
G l li
r e
s
e
io
n n =
B l
in k
in
g O
r
a
n
g e
R
ig
h t
1
0 M
b p
s =
S o
l id
O
1
r
0
a
0
n
M
g
e
b
p s
= O
ff
S
t a
tu s
Français
• Branchez l’alimentation électrique.
Connectez les
2
périphériques
• Tous les ports sont configurés de manière à détecter automatiquement la vitesse et le mode duplex du périphérique connecté.
• Connectez les PC et les serveurs d’impression au switch à l’aide de câbles directs.
• Utilisez un câble croisé pour connecter le switch à un autre switch ou à un hub.
• Utilisez un câble direct pour vous connecter à un autre switch ou à un hub lorsque le port 1 est défini sur MDI.
• Utilisez uniquement un câble CA T 5 UTP pour connecter des périphériques 100 Mbps. Pour connecter des périphériques 10 Mbps, utilisez un câble CAT 3, 4 ou 5 UTP.
Étagère : enlevez la pellicule
adhésive et placez les supports en caoutchouc sous le switch.
De À
Direct
Switch PC/Serveur
Switch Serveur d’impression
Croisé
10/100
Switch Hub ou Switch
Direct
Lorsque le port 1 est défini sur
Switch Hub ou Switch
MDI
10/100
8
Vérifiez les
3
connexions
• Vérifiez les diodes du port pour confirmer l’état de la liaison.
• Une lumière verte continue (sur le côté gauche) indique une liaison valable.
Gauche (vert/orange)
Vert continu = Liaison Vert clignotant = Activité Orange clignotant = Collision
ackable Hub
Droite (orange)
Éteint = 100 Mbps Continu = 10 Mbps
Module A
45678
S
Informations facultatives
Comment changer le
4
5
port 1 de MDI-X en MDI ?
• Tous les ports du switch sont de type MDI-X. Pour changer le port 1 en MDI, appuyez sur le bouton MDI/MDI-X. Vous pourrez ainsi vous connecter à un autre switch ou à un hub à l’aide d’un câble direct.
Accédez à l’écran de configuration
Intel® Express 410T Standalone
MDI
12345
MDI-X
Bouton MDI/MDI-X
MDI
MDI-X
• Connectez votre PC au port série du module de gestion en utilisant le câble de modem null joint.
• Définissez les paramètres suivants pour un programme d’émulation de terminal compatible VT100 (tel que HyperTerminal*) :
- 9600 bauds - 8 bits de données
- Pas de parité - 1 bit d’arrêt
- Pas de contrôle de flux
Appuyez sur E pour vous connecter à l’écran de configuration.
• Utilisez les touches suivantes pour parcourir les menus :
T Passe à l’élément suivant.
B Passe à l’élément précédent.
z Active les options dans un champ. c + S Enregistre les modifications dans
la configuration.
c + R Rafraîchit l’écran.
• <Auto> est la valeur par défaut définie pour ces ports. Si vous ne parvenez pas à connecter un périphérique, configurez ces paramètres de port.
Français
Écran de configuration : les éléments placés entre les signes < > indiquent un champ à bascule. Appuyez sur z pour passer d’une sélection à l’autre.
Speed Auto = Tous les ports sont
automatiquement paramétrés. 100 = Port défini sur 100 Mbps. 10 = Port défini sur 10 Mbps.
Duplex Half = Port défini sur semi-duplex.
Full =Port défini sur duplex intégral. – = Port défini sur le mode auto.
Flow enable = Contrôle de flux activé en Control mode duplex intégral. La
pression arrière est activée en
mode semi-duplex. disable = Contrôle de flux désactivé. – = Port défini sur le mode auto.
9
9
Introduzione rapida
Italiano
1
2
Installazione dello switch
• Rimuovere lo switch e le altre parti dalla confezione.
• Se si intende montare lo switch a rack, fissare i supporti allegati.
• Installare Intel® Express 410T Standalone Switch in un rack o su un ripiano.
• Collegare il cavo di alimentazione.
Collegamento dei dispositivi
• Tutte le porte sono in grado di rilevare la velocità e la modalità duplex dei dispositivi collegati.
• Connettere i PC e i server di stampa utilizzando un cavo diretto.
• Utilizzare un cavo incrociato per connettere uno switch a un altro switch o hub.
• Utilizzare un cavo diretto per la connessione a un altro hub o switch quando la porta viene impostata su MDI.
• Usare soltanto cavo UTP CAT 5 per collegare i dispositivi a 100 Mbps. Per collegare dispositivi a 10 Mbps usare cavo UTP CAT 3, 4 o 5.
A rack: usare le tre piccole viti per fissare i supporti allo switch.
®
Intel
Express 410T Standalone Switch
M
DI/
1
M
D
I-X
2
3
4
5
6
8
9
1
0
1
1
1
2
1
3
1
47
1
5
L
e ft
1
6
L
in k
= S
o
lid G
re
en
A
cti v
ity
= B
lin
kin
g
C
G o lli
re
sio
e
n n =
B l
in k
in
g O
ra
n
g e
R
ig
h t
1
0 M
b p
s =
S ol
id
O
1
ra
00
ng
M
e
b
ps
= O
ff
S
ta
t u s
Su ripiano: rimuovere la protezione dell’autoadesivo dai piedini in gomma e farli aderire allo switch.
Da A
diretto
Switch PC/Server
Switch Server di stampa
incrociato
10/100
Switch Hub o Switch
diretto
quando la porta 1 viene
Switch Hub o Switch
impostata su MDI
10/100
10
Controllo dei
3
collegamenti
• Controllare le spie LED delle porte per verificare lo stato del collegamento.
• Una spia LED verde accesa con continuità (sulla sinistra) indica un collegamento valido.
Sinistra (verde/arancione)
Verde costante = Collegamento Verde lampeggiante = Attività Arancione lampeggiante = Collisioni
ackable Hub
Destra (arancione)
Spenta = 100 Mbps Accesa costante = 10 Mbps
Module A
45678
Loading...
+ 28 hidden pages