The T8700 Electronic Round™ Programmable Thermostats provide single-stage, programmable temperature control for 24V heating and/or cooling systems. See Table 1 for model descriptions.
Table 1. T8700 Thermostat Description.
Model
T8700B1007 HEAT-OFF NONE R,W T8700B1015 HEAT-OFF ON-AUTO R,G,W T8700C1005 HEAT-OFF-
System
Selection
COOL
Fan
Selection
ON-AUTO R,G,W,Y
Wiring
Terminals
Used
T8700B,C
An Electronic Round
PRODUCT DATA
FEATURES
• Attractive neutral styling complements any decor.
• Easy-to-use means fewer homeowner questions and increased homeowner satisfaction.
• Large easy-to-read display.
•Keys located near the display for easy access.
•Fan and System switches are located on the top of the wallplate to eliminate accidental setting changes.
• Quick and easy installation.
Two-period programming for added energy savings.
• Manual changeover from heat to cool eliminates unexpected system operation (T8700C).
°F or °C temperature display for added model flexibility.
• Selectable heating cycle rate (1, 3, 6 or 9 cph) allows a variety of applications and reduced inventory.
• Cooling (T8700C) cycle rate fixed at 3 cph (the standard setting for compressors) allows a speedy installation.
•Programming permanently held in memory (no batteries needed) and retained during power outages for increased installer and homeowner convenience.
• Compatible with most equipment and application needs including gas, oil and electric forced air; condensing gas furnaces; hydronic heat; and gravity and radiant heat systems.
•Powerstealing eliminates need to run additional wires.
Contents
Application........................................................................... 1
Features .............................................................................. 1
Specifications ...................................................................... 2
Ordering Information ........................................................... 2
Installation ........................................................................... 3
Settings and Adjustments ................................................... 6
Setting the Clock ................................................................. 7
Programming....................................................................... 7
Operation ............................................................................ 8
Checkout .............................................................................10
Troubleshooting ................................................................... 11
® U.S. Registered Trademark Copyright © 1998 Honeywell Inc. • • All Rights Reserved
T8700B,C AN ELECTRONIC ROUND™ PROGRAMMABLE THERMOSTAT
SPECIFICATIONS
IMPORTANT
The specifications given in this publication do not include normal manufacturing tolerances; therefore, an individual unit might not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed.
T8700 TRADELINE® models include a thermostat, wallplate, decorator cover plate and owner’s guide. The package also includes a resistor for use with Taco zone valves. See Fig. 11.
Power:
T8700: 24 Vac nominal, 18 to 30 Vac, 60 Hz.
Electrical Ratings:
Heating: .02 to 1.2A run; 3.5A inrush. Cooling: .02 to 1.2A run; 6.0A inrush. Fan: .02 to 0.5A run; 2.5A inrush.
Current Draw:
T8700 Power Stealing Thermostat requires only 2.5 mA current draw when the thermostat calls for heat or cool and is compatible with most 24V systems. It can be used in most non-millivolt applications. See Power Stealing in the Operation section.
Temperature Adjustment:
Setpoint temperature is adjusted by using the or keys. One press changes the setpoint one degree; pressing and holding changes the setpoint several degrees.
Cycle Rates (at 50 Percent Load):
Heating: Selectable at 1, 3, 6 or 9 cph. See Table 2 for
heating cycle rates and corresponding system equipment.
Cooling (T8700C): Fixed at 3 cph.
Table 2. Heating Cycle Rates.
Cycles per
System
Hour (cph)
Steam, Gravity 1 Hydronic Heat, Condensing Gas Furnaces 3 Gas or Oil Forced Air 6 Electric Furnace 9
Finish:
T8700: Premier White® color.
Dimensions:
See Fig. 1.
1-1/2
5-1/2
4-1/4
T
A
E
H
F
F
O
L
O
O
C
3-1/2
F
A
N
O
N
A
U
T
PM
O
Temperature Setting Range:
40°F (4°C) to 99°F (37°C).
Set
Operational Ambient Temperature Range:
30°F (4°C) to 110°F (43°C).
Shipping Temperature Range:
-20°F (29°C) to 120°F (49°C).
Operating Relative Humidity:
5% to 90% RH, noncondensing.
M12579
DECORATOR COVER PLATE
Fig. 1. T8700 Thermostat dimensions (T8700C shown).
T8700
THERMOSTAT
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for the complete ordering number.
1. Order number.
2. Accessory, if desired.
If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:
1. Your local Home and Building Control Sales Office (check white pages of your phone directory).
2. Home and Building Control Customer Logistics Honeywell Inc., 1985 Douglas Drive North Minneapolis, Minnesota 55422-4386
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0197—1
2
T8700B,C AN ELECTRONIC ROUND PROGRAMMABLE THERMOSTAT
INSTALLATION
When Installing this Product…
1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application.
3. Installer must be a trained, experienced service technician.
4. After installation is complete, check out product operation as provided in these instructions.
CAUTION
Damage To Heating/Cooling System Possible. Be careful when handling wires during installation.
Disconnect power at furnace or at main breaker/fuse box before starting installation.
RECYCLING NOTICE
If this control is replacing a control that contains mercury in a sealed tube, do control in the trash.
Contact your local waste management authority for instructions regarding recycling and the proper disposal of an old control containing mercury in a sealed tube.
not
place your old
Location
Install the thermostat about 5 ft (1.5m) above the floor in an area with good air circulation at average temperature. See Fig. 2. Do not install the thermostat where it can be affected by: —Drafts or dead spots behind doors and in corners. — Hot or cold air from ducts. — Radiant heat from the sun or appliances. — Concealed pipes and chimneys. — Unheated (uncooled) areas such as an outside wall
behind the thermostat.
Mounting Decorator Cover Plate and Wallplate to Wall
IMPORTANT
Position and level the wallplate for appearance only. The thermostat functions properly even when not level.
Mount decorator cover plate (if desired), wallplate, T8700 and the screws as follows; see Fig. 3:
1. Place the decorator cover plate and the wallplate on the
desired wall location.
2. Pull the thermostat wire through the entrance hole on
the decorator cover plate, then through the wallplate entrance hole.
3. Plug the wiring hole behind the thermostat to prevent
drafts from affecting the thermostat.
4. Select the two mounting holes that best fit the
application.
5. Fasten the decorator cover plate and the wallplate to
the wall using the provided anchors (if necessary) and screws.
NO
YES
NO
NO
5 FEET
[1.5 METERS]
Fig. 2. Typical thermostat location.
3
M12524
68-0197—1
T8700B,C AN ELECTRONIC ROUND™ PROGRAMMABLE THERMOSTAT
WALL
DECORATOR COVER PLATE
WALLPLATE
E
A
H
T
F
F
O
L
O
O
C
1
WHEN USING WALL ANCHORS, DRILL 3/16 INCH HOLES FOR DRYWALL, 7/32 INCH HOLES FOR PLASTER OR WOOD.
F
A
N
O
N
A
U
T
O
Fig. 3. Mounting decorator cover plate and wallplate on wall (T8700C shown).
PLASTIC SCREW ANCHOR (2)
M12532A
ROUTE WIRING AS SHOWN THROUGH ENTRANCE HOLE
F
O
L
O
O
C
1
MOUNTING SCREW HOLE
T
A
E
H
F
WIRING ENTRANCE HOLE
G
ALTERNATE MOUNTING
F
A
N
O
R
Y
W
SCREW HOLE
MOUNTING
N
A
U
ALTERNATE
MOUNTING
SCREW HOLE
SCREW
T
O
HOLE
M12529
Fig. 4. T8700C wallplate wiring connections.
(Refer to Table 1 for T8700B wiring connections.)
The shape of the terminals permits insertion of straight or wraparound wiring connections; either method is acceptable. See Fig. 5.
Wiring
CAUTION
Damage To Heating/Cooling System Possible. Be careful when handling wires during installation.
Disconnect power at furnace or at main breaker/fuse box.
IMPORTANT
Use an 18-gauge maximum wire for wiring the T8700 Thermostat.
All wiring must comply with local electrical codes and ordinances. A letter is located near each terminal for identification.
NOTE: To ensure proper mounting of thermostat, restrict all
wiring to the left side of the terminals. See Fig. 4.
FOR WRAPAROUND, STRIP 7/16 IN. (11 mm)
FOR STRAIGHT INSERTION, STRIP 5/16 IN. (8 mm)
M12537
Fig. 5. Wiring connections.
The T8700 Thermostat steals power through the heating and/or cooling system controls and is adaptable to most, 24 Vac systems. Refer to Fig. 6 through 11 for typical wiring hookups.
24V
T8700B
FAN RELAY
HEATING PRIMARY CONTROL
M16005B
R
G
W
1
L1 (HOT)
L2
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
1
OVERLOAD PROTECTION AS REQUIRED.
Fig. 6. T8700B1007 Heat Only wiring diagram
T8700B1015 Heat Only with Fan includes dotted line.
68-0197—1