Honeywell SERIE2000 User Manual

Series 2000 Commercial
Microelectronic Thermostat
Contents
Features .................................................................. 3
Programming........................................................... 4
® U.S. Registered Trademark Copyright © 1996 Honeywell Inc. • All Rights Reserved
1 63-4356—1
63-4356-1
ENTER OCCUPIED PROGRAM MODE
ENTER UNOCCUPIED PROGRAM MODE
SET CURRENT DAY OR PROGRAM DAY
SET OCCUPIED TEMPERATURE SETPOINTS
SET UNOCCUPIED TEMPERATURE SETPOINTS
AM
Mon
Occupied
System Fan
RETURNS TO NORMAL OPERATIONS
SET OVERRIDE TEMPERATURE OFFSET AND ACTIVATE TEMPORARY OVERRIDE
ENTER HOLD MODE
Run
Program
Temporary
Occupied
Continuous
Unoccupied
Occupied
Start Time
Set Current
Day/Time
SET CURRENT DAY AND TIME
Heat
Set Program Set Temperature Change
Unoccupied
Start Time Day
Clear
Start Time
Copy
CLEAR PROGRAM PERIOD
63-4356—1 2
Room
Auto
Occupied
Unoccupied
Temp
System Fan
SELECT SYSTEM
COPY ONE PROGRAMMED DAY TO ANOTHER DAY
OPERATION
Temp
Heat/Cool
Settings
Time/Temp
SELECT FAN OPERATION
INCREASE TEMPERATURE OR TIME SETTING
DECREASE TEMPERATURE OR TIME SETTING
CHANGE BETWEEN HEATING AND COOLING SETPOINTS
M10256
FEATURES
•Program up to two Occupied and two Unoccupied time periods for each daily schedule.
• Set different schedules for each day of the week.
•Temporary temperature overrides.
•Program copy key.
3 63-4356—1
PROGRAMMING
The keyboard is located behind the thermostat cover. Sixteen keys are used to set, review and modify programmed times and temperature settings. The thermostat display shows day, time, program period and temperature.
The thermostat can be set for two Occupied and two Unoccupied times for each day of the week (28 independent time settings). Temporary Occupied
63-4356—1 4
key provides quick temporary temperature changes for increased occupant comfort. The Continuous Unoccupied key provides energy efficient operation for extend periods of time.
Before starting the program procedure, use the following chart to organize the program schedule.
Day
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Occupied
Period 1
Unoccupied
Period 1
5 63-4356—1
Occupied
Period 2
Unoccupied
Period 2
The program has four temperature settings, Occupied and Unoccupied heat and cool. The thermostat will operate at the Unoccupied temperature setting unless the thermostat is programmed. The following chart shows the default temperature settings.
Occupied
Setpoint
Unoccupied
Setpoint
Control Default Desired Default Desired
Heating 70°F
(21°C)
Cooling 78°F
(25.5°C)
63-4356—1 6
55°F (13°C)
90°F (32°C)
Setting Current Day and Time
Press Set Current Day/Time.
NOTE: On initial power up or after an
extended power loss, 1:00 pm flashes on the LCD until a key is pressed.
Set Current
Day/Time
Set Program Set Temperature Change
Unoccupied
Occupied
Run
Start Time Day
Start Time
Program
Temporary
Set Current
Occupied
Day/Time
Start Time
Continous
Unoccupied
Time/Temp
Occupied
Unoccupied
Temp
Temp
System Fan
Mon
Heat/Cool
Settings
Clear
Copy
Set Day/Time
PM
M4951B
Loading...
+ 14 hidden pages