Honeywell Sensepoint XCL Specifications

Gas Detection
Sensepoint XCL
Fixed Gas Detector
Sensepoint XCL is a fixed point gas leak detector that is designed to meet the needs of commercial and light industrial applications. With over 50 years experience in gas leak detection, Honey well offers a flexible range of highly-reliable sensing devices to meet those needs.
• Rapid configuration
• Simple to operate
• Straightforward to maintain Honeywell innovation enables customers to pair the gas detector with
their mobile phone, and then use an app to perform many tasks related to installation, commissioning and maintenance.
Flexible Output Options
Sensepoint XCL is available with either mA loop analog output or Modbus RTU with the option for relays on both. The result is a flexible solution that can easily be incorporated into legacy systems as well as new installations.
Faster Installation
Everything you need for installation is in the box, including simple drilling templates.
Easy Control and Maintenance
Sensepoint XCL's smartphone interface makes for much faster calibration, configuration and bump tests. Inspecting the status and settings of individual Sensepoint XCL detectors is simple. Use the mobile app to:
• Read gas concentrations in real-time
• Reconfigure settings
• Check unit histories
Automated Reporting
Increase the efficiency of your operations and reduce administration time. The app and Sensepoint XCL provides easy access to diagnostic information and generates calibration reports at the touch of a screen.
Compatible System Controller
Touchpoint Plus is the perfect complement to Sensepoint XCL, providing
an intuitive, easy to operate gas detection solution to meet the needs of your business.
Visual Integration
Sensepoint XCL is designed with the needs of building architects in mind. Clean aesthetics and a choice of colors mean that the detector is ideal for public spaces like lobbies and retail environments.
Typical Applications
• Kitchens and food processing
• Manufacturing facilities and factories
• Hospitals
• Retail sites
• Transportation and parking
• Laboratories
• Hotel and leisure
• Apartments, accommodation blocks and condominiums
Accessories
• Calibration cap / flow housing
• Duct mount kit for round or flat profile ducts
FEATURES & BENEFITS
• Choose from a range of mA or Modbus output versions for flexible system design to meet the customers requirements.
• Selectable source or sink current for analog output enables one detector to be suitable for both system configurations.
• Optional relay output for external control systems or alarming devices enables easy integration and local indication.
• The ingress protection of IP65 allows units to be mounted in wash down areas.
• Multi- color visual indicator to show status makes it easier to know the detector status immediately and identify detectors that require attention or are warning of danger.
• Gassing port for easier bump test of units installed in inaccessible locations. No need to purchase a separate accessory and thus saves money.
• Manage the detector without making a physical connection. Remove the need for physical access to hard-to-reach devices.
• Simplified maintenance with familiar smartphone technology saves money and time.
Sensepoint XCL Technical Specifications
PHYSICAL PROPERTIES
DIMENSIONS
113 x 113 x 59 mm ( 4.4 x 4.4 x 2.3 in )
WEIGHT
CASING MATERIAL
INGRESS PROTECTION RATING
500 g (1.1 lb)
Polycarbonate (charcoal or white)
IP65, Type 4 (in accordance with NEMA 250)
LIFETIME
AVAILABLE SENSORS
FLAMMABLE, TOXIC GASES AND OXYGEN RANGES
10 years (excludes sensor)
• Combustible: 0 to 100 % LEL (factory
• O: 0 to 25% vol
• CO: 300 ppm (adjustable between 50
• H: 1000 ppm
• HS Low Range: 50 ppm (adjustable
• HS High Range: 100 ppm (adjustable
• NO: 20 ppm (adjustable between
• NH: 200 ppm (adjustable between
• CO2 (ppm range): 5,000 ppm
• CO2 (% vol range): 5.0% vol
POWER SUPPLY
NOMINAL DC INPUT VOLTAGE
NOMINAL AC INPUT VOLTAGE
MAXIMUM INRUSH CURRENT
OUTPUT
ANALOG OUTPUT
DIGITAL OUTPUT
RELAY OUTPUT
MAXIMUM POWER CONSUMPTION
mA VERSIONS
MODBUS VERSIONS
RELAY VERSIONS
mA ver sions: 11 to 32 V DC, Modb us version s: 9 to 32 VDC
All ver sions: 20 to 27 VAC
24 V DC†
24 V AC‡, 50/60 Hz
850 mA
0 to 22 mA
Modbus RTU
2 relays rated at 24 V DC / 240 V AC, 5 A
< 1.2 W (toxic), < 1.7 W (flammable and CO2)
< 0.7 W (toxic), < 1.2 W (flammable and CO2)
Additional 0.6 W total
calibrated to Methane)
and 1000 ppm)
between 10 and 50 ppm)
between 50 and 200 ppm)
5 and 50 ppm)
50 and 200 ppm)
(adjustable between 1,000 and 5,000 ppm)
(adjustable between 1.0 and 5.0% vol)
CONNECTION
TYPE
USER INTERFACE
VISUAL INDICATOR
Pluggable rising clamp style, 0.5 to
2
1.5 mm
, 20 to 16 AWG.
Multi-colour LED light ring
• Green: normal§
• Flashing red: Alarm
• Flashing green and yellow: Warning
• Flashing yellow: Fault
• Solid yellow: Inhibited
• Flashing blue: Bluetooth pairing in progress
• Solid blue: Bluetooth connection established
WIRELESS INTERFACE
Bluetooth 4.0 (Bluetooth Low Energy). Dedicated mobile app, enabling wireless configuration and maintenance. Connect up to 10 m away (mobile device dependent). Use a compatible smartphone or other mobile device running Android 4.3 or above.
OPERATING ENVIRONMENT
OPERATING TEMPERATURE
STORAGE TEMPERATURE
HUMIDITY
ATMOSPHERIC PRESSURE
APPROVALS
ELECTRICAL SAFETY
−20 to 50°C (−4 to 122 °F) 0 to 30°C
(32 to 86 °F)
15 to 90% RH (non-condensing)
90 to 110 kPa
EN/UL/IEC610101 CSAC22.2 No. 61010112
EMC
RADIO
OTHER
§
LED be havior in nor mal conditi on can be chan ged by the use r: solid g reen, gree n confidenc e
lash or off.
f
EN 50270
RED, FCC
UL2075 (CO and CH4), AS 1668.2
For more information
www.honeywellanalytics.com
Europe, Middle East, Africa
Life Safety Distribution GmbH Tel: 00800 333 222 44 (Freephone number) Tel: +41 44 943 4380 (Alternative number)
Middle East Tel: +971 4 450 5800 (Fixed gas detection)
Middle East Tel: +971 4 450 5852 (Portable gas
detection)
Americas
Honeywell Analytics Distribution Inc. Tel: +1 847 955 8200 Toll free: +1 800 538 0363
RAE Systems by Honeywell
Phone: 408.952.8200 Toll Free: 1.888.723.4800
Asia Pacific, India
Honeywell Analytics Asia Pacific North Asia Tel: +82 (0) 2 6909 0300 South East Asia Tel: +65 6580 3662 India Tel: +91 124 4752700 China Tel: +86 10 5885 87883000
www.honeywell.com
DS_01178 | Rev. 01 | 05/2018 © 2018 Honeywell International Inc.
Loading...