Gas Detection
Sensepoint XCL
Fixed Gas Detector
Sensepoint XCL is a fixed point gas leak detector that is designed to meet
the needs of commercial and light industrial applications. With over 50
years experience in gas leak detection, Honey well offers a flexible range
of highly-reliable sensing devices to meet those needs.
• Quicker installation
• Rapid configuration
• Simple to operate
• Straightforward to maintain
Honeywell innovation enables customers to pair the gas detector with
their mobile phone, and then use an app to perform many tasks related
to installation, commissioning and maintenance.
Flexible Output Options
Sensepoint XCL is available with either mA loop analog output or
Modbus RTU with the option for relays on both. The result is a flexible
solution that can easily be incorporated into legacy systems as well as
new installations.
Faster Installation
Everything you need for installation is in the box, including simple drilling
templates.
Easy Control and Maintenance
Sensepoint XCL's smartphone interface makes for much faster
calibration, configuration and bump tests. Inspecting the status and
settings of individual Sensepoint XCL detectors is simple. Use the
mobile app to:
• Read gas concentrations in real-time
• Reconfigure settings
• Check unit histories
Automated Reporting
Increase the efficiency of your operations and reduce administration
time. The app and Sensepoint XCL provides easy access to diagnostic
information and generates calibration reports at the touch of a screen.
Compatible System Controller
Touchpoint Plus is the perfect complement to Sensepoint XCL, providing
an intuitive, easy to operate gas detection solution to meet the needs of
your business.
Visual Integration
Sensepoint XCL is designed with the needs of
building architects in mind. Clean aesthetics
and a choice of colors mean that the detector
is ideal for public spaces like lobbies and retail
environments.
Typical Applications
• Kitchens and food processing
• Manufacturing facilities and factories
• Hospitals
• Retail sites
• Transportation and parking
• Laboratories
• Hotel and leisure
• Apartments, accommodation blocks and
condominiums
Accessories
• Calibration cap / flow housing
• Duct mount kit for round or flat profile ducts
FEATURES & BENEFITS
• Choose from a range
of mA or Modbus
output versions for
flexible system design
to meet the
customers
requirements.
• Selectable source or
sink current for
analog output
enables one detector
to be suitable for both
system
configurations.
• Optional relay output
for external control
systems or alarming
devices enables easy
integration and local
indication.
• The ingress
protection of IP65
allows units to be
mounted in wash
down areas.
• Multi- color visual
indicator to show
status makes it easier
to know the detector
status immediately
and identify detectors
that require attention
or are warning of
danger.
• Gassing port for
easier bump test of
units installed in
inaccessible
locations. No need to
purchase a separate
accessory and thus
saves money.
• Manage the detector
without making a
physical connection.
Remove the need for
physical access to
hard-to-reach
devices.
• Simplified
maintenance with
familiar smartphone
technology saves
money and time.
Sensepoint XCL Technical Specifications
PHYSICAL PROPERTIES
DIMENSIONS
113 x 113 x 59 mm
( 4.4 x 4.4 x 2.3 in )
WEIGHT
CASING MATERIAL
INGRESS PROTECTION RATING
500 g (1.1 lb)
Polycarbonate (charcoal or white)
IP65, Type 4 (in accordance with
NEMA 250)
LIFETIME
AVAILABLE SENSORS
FLAMMABLE, TOXIC GASES AND
OXYGEN RANGES
10 years (excludes sensor)
• Combustible: 0 to 100 % LEL (factory
• O: 0 to 25% vol
• CO: 300 ppm (adjustable between 50
• H: 1000 ppm
• HS Low Range: 50 ppm (adjustable
• HS High Range: 100 ppm (adjustable
• NO: 20 ppm (adjustable between
• NH: 200 ppm (adjustable between
• CO2 (ppm range): 5,000 ppm
• CO2 (% vol range): 5.0% vol
POWER SUPPLY
NOMINAL DC INPUT VOLTAGE
NOMINAL AC INPUT VOLTAGE
MAXIMUM INRUSH CURRENT
OUTPUT
ANALOG OUTPUT
DIGITAL OUTPUT
RELAY OUTPUT
MAXIMUM POWER CONSUMPTION
mA VERSIONS
MODBUS VERSIONS
RELAY VERSIONS
†
mA ver sions: 11 to 32 V DC, Modb us version s: 9 to 32 VDC
‡
All ver sions: 20 to 27 VAC
24 V DC†
24 V AC‡, 50/60 Hz
850 mA
0 to 22 mA
Modbus RTU
2 relays rated at 24 V DC / 240 V AC, 5 A
< 1.2 W (toxic), < 1.7 W (flammable and CO2)
< 0.7 W (toxic), < 1.2 W (flammable and CO2)
Additional 0.6 W total
calibrated to Methane)
and 1000 ppm)
between 10 and 50 ppm)
between 50 and 200 ppm)
5 and 50 ppm)
50 and 200 ppm)
(adjustable between 1,000 and 5,000
ppm)
(adjustable between 1.0 and 5.0%
vol)
CONNECTION
TYPE
USER INTERFACE
VISUAL INDICATOR
Pluggable rising clamp style, 0.5 to
2
1.5 mm
, 20 to 16 AWG.
Multi-colour LED light ring
• Green: normal§
• Flashing red: Alarm
• Flashing green and yellow: Warning
• Flashing yellow: Fault
• Solid yellow: Inhibited
• Flashing blue: Bluetooth pairing in
progress
• Solid blue: Bluetooth connection
established
WIRELESS INTERFACE
Bluetooth 4.0 (Bluetooth Low Energy).
Dedicated mobile app, enabling wireless
configuration and maintenance.
Connect up to 10 m away (mobile
device dependent). Use a compatible
smartphone or other mobile device
running Android 4.3 or above.
OPERATING ENVIRONMENT
OPERATING TEMPERATURE
STORAGE TEMPERATURE
HUMIDITY
ATMOSPHERIC PRESSURE
APPROVALS
ELECTRICAL SAFETY
−20 to 50°C (−4 to 122 °F) 0 to 30°C
(32 to 86 °F)
15 to 90% RH (non-condensing)
90 to 110 kPa
EN/UL/IEC610101
CSAC22.2 No. 61010112
EMC
RADIO
OTHER
§
LED be havior in nor mal conditi on can be chan ged by the use r: solid g reen, gree n confidenc e
lash or off.
f
EN 50270
RED, FCC
UL2075 (CO and CH4), AS 1668.2
For more information
www.honeywellanalytics.com
Europe, Middle East, Africa
Life Safety Distribution GmbH
Tel: 00800 333 222 44 (Freephone number)
Tel: +41 44 943 4380 (Alternative number)
Middle East Tel: +971 4 450 5800 (Fixed gas detection)
Middle East Tel: +971 4 450 5852 (Portable gas
detection)
Americas
Honeywell Analytics Distribution Inc.
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
RAE Systems by Honeywell
Phone: 408.952.8200
Toll Free: 1.888.723.4800
Asia Pacific, India
Honeywell Analytics Asia Pacific
North Asia Tel: +82 (0) 2 6909 0300
South East Asia Tel: +65 6580 3662
India Tel: +91 124 4752700
China Tel: +86 10 5885 87883000
www.honeywell.com
DS_01178 | Rev. 01 | 05/2018