Sensepoint Plus
The Sensepoint Plus monitors
flammable, toxic and oxygen
gas hazards in potentially
explosive atmospheres

Sensepoint Plus
One-Stop Shop
• Flammable, toxic and oxygen versions available
• Suitable for indoor or outdoor use
• IP65 as standard
Proven Sensor Technology
• SurecellTM electrochemical sensors
• Poison resistant catalytic bead
• Fast and reliable
• Typical 2 to 5 years operational life
Global Certifications*
• US and Europe
• UL and ATEX hazardous area approvals
Convenient to Use
• Industry standard 4-20mA output
• Built in ‘inhibit’ switch
• User configurable setting
• Ideal for PLC based systems
Cost Effective
• Minimal training required
• One-man operation
• Plug-in sensor replacement
• All necessary accessories included
Friendly Installation
• Universal mounting bracket
• Metric and NPT compatible
• Suitable for conduit or armored
cable/glands installations
Range of Accessories
• Calibration cup
• Duct mounting kit
• Collecting cone
*Pending - Contact Honeywell Analytics
for more information
The Sensepoint Plus monitors flammable,
toxic and oxygen gas hazards in potentially
explosive atmospheres and provides an
industry standard 4-20mA output for
connection to a wide range of control
equipment. Incorporation of a transmitter at
the sensor enables a single user to carry out
routine maintenance of the detector and
removes the need for additional personnel
at the associated controller.
The built-in transmitter includes a user configurable
‘inhibitswitch’thatclampsthecurrentoutputofthe
detector to a known level so that during
maintenance no false alarms can be triggered at
associated control equipment. As such, the
Sensepoint Plus can be easily maintained even
whenusedwith‘blind’PLCtypecontrolsystems.
Sensepoint Plus is supplied with all necessary
accessories for easy installation. The detector can
be mounted on a wall or round support pole using
the universal bracket provided. The detector is ideal
for use with either conduit or armored cable and
glands. A 3/4"NPT entry and M20 adaptor are
supplied as standard. A weatherproof cap is also
included for use in the harshest outdoor conditions.
Overall, the Sensepoint Plus provides easy
installation and simple maintenance. Using an easy
to replace plug-in sensor, downtime is reduced and
the on-going costs of ownership is minimized
through the use of poison resistant flammable
sensors and patented SurecellTM toxic sensor
technology.
SensepointPlusandtheHoneywellAnalytic’srange
of industrial gas detection systems can
be trusted to provide a safe working environment
for all.

Installation Details
Sensepoint Plus is designed for use in
potentially explosive atmospheres. As such,
installation should follow national guidelines
using suitably approved armored cable
and glands (M20 or 3/4"NPT) or conduit
(3/4"NPT).
Use screened 0.5mm2 (20AWG) to 2.5mm2
(14AWG) cross sectional area cable, as
needed to ensure minimum operating voltage
at the detector, depending upon installed
cable length.
Various accessories are available for
different applications.
Pole Mount
Duct Mount
Wall Mount
Collecting Cone
Dimensions
174.8mm / 6.9"
74.0mm / 2.9"
Electrical Connections
126.2mm / 5.0"
36.0mm / 1.4"
104.0mm / 4.1"
107.0mm / 4.2"
ø 20.0 - 80.0mm
/ 0.8 - 3.1"
102.0mm / 4.0"
100ohm

Technical Summary
General Specification
Use 3 wire, 4-20mA, fixed point gas detector for the protection of personnel and plant from flammable, toxic and oxygen gas hazards.
Incorporating transmitter with user configurable ‘inhibit’ switch to facilitate one man operation
Detectable Gases
Gas Measuring Range Operating Temperature*
Ident Name 1# 2 3 Min Max
F Flammable 0-100% LEL -20°C / -4°F 50°C / 122°F
O Oxygen 0-25% VOL -15°C / 5°F 40°C / 104°F
+
C Carbon Monoxide
H Hydrogen Sulfide
G Hydrogen 0-1000ppm -5°C / 23°F 40°C / 104°F
+ SureCellTM Sensing Technology
Construction
Electrical
3 x screw terminals for 0.5mm
Maximum operating current: 200mA (flammable), 30mA (toxic and oxygen)
Maximum peak in rush current: 400mA
Signal 4-20mA Normal operation: 0-100% full scale
2mA or 4mA Output inhibited (17.4mA Oxygen only)
0mA Sensor fault
22mA Maximum over range
Material Main body: Powder coated aluminum (ADC12)
Sensor: 316 stainless steel
Weatherproof cap: Aluminum, 316 stainless steel mesh
Weight 950g
Certification Ex II 2 G D EEx d IIC T6 Class 1, Div 1, Groups B, C, D
T
Applicable Standards North America: UL1203
Standards Europe: CE, ATEX, EMC (EN50270)
Contact Honeywell Analytics for latest approval information
Environmental
IP Rating IP65 as standard in accordance with EN60529:1992
Operating Temperature Dependent upon gas type and certification
Operating Humidity Range Continuous: 20-90%RH (non condensing), Intermittent: 10-99%RH (non condensing)
Operating Pressure 90-110kPa
Storage Conditions Instrument -40°C to +50°C (-40°F to +122°F)
0-200ppm 0-500ppm -20°C / -4°F 50°C / 122°F
+
0-50ppm 0-20ppm 0-100ppm -20°C / -4°F 50°C / 122°F
#
Standard *Check certified temperature
3 wire connection, 12-30Vdc, 4-20mA (source), common 0Vdc
2
(20AWG) to 2.5mm2 (14AWG)
= -20°C to +50°C / -4°F to +122°F T
amb
= -20°C to +50°C / -4°F to +122°F)
amb
* Oxygen detection products must only be used to detect oxygen depletion in air.

Ordering Information
Ordering Information
e.g. SP PL U X F 1 = SPPLUXF1
STANDARDS
U USA (UL)
A Europe (ATEX)
Standard Supply Each detector is supplied complete with 3/4"NPT entry, 3/4"NPT to M20 adaptor, wall mounting bracket,
pole mounting bracket, weatherproof cap, Allen keys (for bracket), and instruction leaflet all sealed in a
plastic bag inside a shipping carton
Shipping Details Shipping carton dimensions: L312mm (12.3") x W223mm (8.8") x D110mm (4.3")
Approximate weight: 1000g
Optional Accessories SPPPCC Collecting cone
SPPPCAL Flow adaptor
SPPPDM Duct mounting kit
Calibration Equipment Contact Honeywell Analytics Representative
RANGE
1 Refer to
2 Detectable Gases
}
3 Table Above
GAS TYPE
F Flammable
O Oxygen
C Carbon Monoxide
H Hydrogen Sulfide
G Hydrogen

Find out more
Contact Honeywell Analytics:
www.honeywellanalytics.com
Europe, Middle East, Africa
Life Safety Distribution AG
Wilstrasse 11-U31
CH-8610 Uster
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
gasdetection@honeywell.com
Our Product Range
Find out more
Contact Honeywell Analytics:
www.honeywellanalytics.com
Europe, Middle East, Africa
Life Safety Distribution AG
Wilstrasse 11-U31
CH-8610 Uster
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
gasdetection@honeywell.com
Americas
Honeywell Analytics Distribution, Inc.
405 Barclay Blvd.
Lincolnshire, IL 60069
USA
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Fax: +1 847 955 8208
detectgas@honeywell.com
Find out more
Contact Honeywell Analytics:
www.honeywellanalytics.com
Europe, Middle East, Africa
Life Safety Distribution AG
Wilstrasse 11-U31
CH-8610 Uster
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
gasdetection@honeywell.com
Americas
Honeywell Analytics Distribution, Inc.
405 Barclay Blvd.
Lincolnshire, IL 60069
USA
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Fax: +1 847 955 8208
detectgas@honeywell.com
Asia Pacific
Honeywell Analytics Asia Pacific
#508, Kolon Science Valley (1)
187-10 Guro-Dong, Guro-Gu
Seoul, 152-050,
Korea
Tel: +82 (0)2 2025 0307
Fax: +82 (0)2 2025 0329
analytics.ap@honeywell.com
Find out more
Contact Honeywell Analytics:
www.honeywellanalytics.com
Europe, Middle East, Africa
Life Safety Distribution AG
Wilstrasse 11-U31
CH-8610 Uster
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
gasdetection@honeywell.com
Americas
Honeywell Analytics Distribution, Inc.
405 Barclay Blvd.
Lincolnshire, IL 60069
USA
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Fax: +1 847 955 8208
detectgas@honeywell.com
www.honeywell.com
Technical Services
ha.emea.service@honeywell.com
Asia Pacific
Honeywell Analytics Asia Pacific
#508, Kolon Science Valley (1)
187-10 Guro-Dong, Guro-Gu
Seoul, 152-050,
Korea
Tel: +82 (0)2 2025 0307
Fax: +82 (0)2 2025 0329
analytics.ap@honeywell.com
Fixed Gas Monitoring
Honeywell Analytics offers a wide range
of fixed gas detection solutions for a
diverse array of industries and applications
including: Commercial properties, industrial
applications, semiconductor manufacturers,
energy plants and petrochemical sites.
Detection of flammable, oxygen and toxic
»
gases (including exotics)
Innovative use of 4 core sensing
»
technologies–papertape,
electrochemical cell, catalytic bead
and infrared
Capability to detect down to Parts Per
»
Billion (ppb) or Percent by Volume (%v/v)
Cost effective regulatory compliance
»
solutions
Please Note:
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions.
Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations,
standards, and guidelines. This publication is not intended to form the basis of a contract.
H_Sensepoint Plus_DS0327_V3_EMEA
09/07
© 2007 Honeywell Analytics
Portable Gas Monitoring
When it comes to personal protection from
gas hazards, Honeywell Analytics has a wide
range of reliable solutions ideally suited for
use in confined or enclosed spaces.
These include:
Detection of flammable, oxygen and
»
toxic gases
Singlegaspersonalmonitors–wornby
»
the individual
Multi-gasportablegasmonitors–used
»
for confined space entry and regulatory
compliance
Multi-gastransportablemonitors–used
»
for temporary protection of area
during site construction and
maintenance activities
Technical Services
At Honeywell Analytics, we believe in the
value of great service and customer care.
Our key commitment is providing complete
and total customer satisfaction. Here are just
a few of the services we can offer:
Full technical support
»
Expert team on hand to answer
»
questions and queries
Fully equipped workshops to ensure
»
quick turnaround on repairs
Comprehensive service engineer network
»
Training on product use and maintenance
»
Mobile calibration service
»
Customised programmes of
»
preventative/corrective maintenance
Extended warranties on products
»
11133