Why Searchpoint Optima Plus
is the right choice...
• Experience gained from over
100,000 units installed worldwide
• Improved reliability
• Optional HART® over 4-20mA output
• Can detect a wide range of hydrocarbon
gases including solvents
• Increased reliability with no moving parts
• Increased stability from self
compensating optics
• Immune to long term component drift
• Remote functional gas test facility
• Certified for North American
and European Hazardous areas
• Increased false alarm rejection
• Increased uptime with
contaminated optics warning
• Dynamic Heating Control ensures
condensation free optics
• No undetected failures
• Improved diagnostics
• Integral event logging
• Reduced power consumption
• Certified to many hazardous area
classification schemes including:
European (ATEX), UL, CSA, IECEx
and more
Market leading point infrared Hydrocarbon
gas detector offering proven performance
and sensitivity
With over 40 years experience in the design,
manufacture, installation and maintenance of
point infrared gas detection, Honeywell Analytics
currently has a Worldwide installed base of over
100,000 infrared point Hydrocarbon gas
detectors in a wide spectrum of applications
from light industrial to the most demanding of
offshore petrochemical environments.
Searchpoint Optima Plus is an infrared point
Hydrocarbon gas detector certified for use in
potentially explosive atmospheres. The unit’s
infrared detection principle offers the fastest
speed of response and fail-to-safe operation,
ensuring that your plant is compliant, your
personnel are protected and your production
process can deliver maximum uptime. Reduced
routine maintenance, when compared with
conventional electro-catalytic based gas
detectors, provides low ongoing cost of
ownership. The development of advanced
internal fault diagnostics and false alarm rejection
algorithms ensures that Searchpoint Optima Plus
delivers the highest level of operational integrity.
Typical applications include environments that
may suffer from the presence of catalytic bead
poisons or inhibitors, or where there are harsh
environmental conditions forcing increased time
between routine maintenance, for example;
offshore oil and gas platforms, floating
production storage and offloading (FPSO)
vessels, tankers, onshore oil and gas terminals,
refineries, LNG / LPG bottling plants, gas
compressor / metering stations, gas turbine
power plants, refineries, solvent printing and
coating plants.
Over 100 gas and vapour calibrations are
available. For a list of detectable gases and
vapours, please contact our Customer Support
team or your local distributor.
Page 3
Failsafe Hydrocarbon
Gas Detection
1. Optics Block
The 4-channel (dual compensated) optics-block is the
heart of the Searchpoint Optima Plus. It is specifically
designed to compensate for changes in the external
environment similar to 2-channel designs, but also
compensates for long term component drift such as
infrared sources and detectors. This provides the
Searchpoint Optima Plus with the most stable optics
design possible.
4.
2. Microprocessor
The microprocessor controls the operation of the
Searchpoint Optima Plus. The signal processing
and algorithms provide a new dimension in false
alarm rejection delivering the highest level of
operational integrity.
3. Heated Optics Plus Dynamic
Heating Control
Heated optic components, monitored via smart
electronics, eliminate condensation build up with power
saving features.
1.
2.
3.
4. Remote Gassing Cell
Factory fitting of this optional gassing cell within
the optical path allows the remote injection of
functional test gas to validate the performance of
a Searchpoint Optima Plus.
Remote Gas Sampling Systems
For monitoring remote or inaccessible locations
Searchpoint Optima Plus can be fitted with a flow housing
and engineered into a gas sampling system. Single-point
and multi-point systems are available for both hazardous
and non-hazardous areas.
Sunshade / Deluge Protection
This multi-purpose accessory supplied as
standard shields Searchpoint Optima Plus
from the extremes of operational environments
ensuring reliable operation.
Storm Baffle
This optional baffle reduces wind chill, salt and
dust build-up in exposed applications subjected
to high wind speeds e.g. Offshore HVAC intakes
and FPSO turrets etc.
Standard Weather Protection
This accessory supplied as standard, offers the
best compromise between water / dust ingress
and speed of response.
Dust Barrier
This barrier fitted inside the standard weather
protection provides additional protection
against the ingress of dust and contamination
entering the optical path.
Gassing Cover
The gassing cover enables confidence checking
of the Searchpoint Optima Plus. It provides a
close fit onto the standard weather protection
and can be installed without the use of any
special tools.
Calibration Cap
The calibration cap is required to
achieve accurate calibration of the
Searchpoint Optima Plus.
XNX Universal Transmitter
This device offers a local display and
non-intrusive access via a magnetic
switch. It has a HART® communications
output and optional Modbus,
Foundation Fieldbus or relays.
HALO Junction Box
This is an Ex e certified junction box,
with an LED light ring to provide a local
visual status indication, and an optional
non-intrusive HART® interface.
Other Accessories
Duct Mounting Kit
This mounting plate arrangement
enables installation of Searchpoint
Optima Plus with a duct/ventilation
system. It enables functional gas
testing without removing the
Searchpoint Optima Plus from
the ducting system.
Page 4
Accessories
Termination / Mounting
Field Interrogation
Multi Purpose Hand Held
Interrogator (SHC-1)
This versatile commissioning /
maintenance tool is certified
for hazardous areas and used
to reconfigure Searchpoint Optima
Plus for different gases and fault
diagnostics. The same interrogator
can be used with the original
Searchpoint Optima and Searchline
Excel (open path gas detector)
reducing operator training.
SHC-1 Protection Device
This device provides electrical
protection for the SHC-1 when used
with conventional terminal housings
under a gas free permit to work
system.
Certified Junction Boxes
A full range of hazardous area certified
Ex e and Ex d junction boxes are
available.
HART®: Reduce your operational costs and gain
enhanced device visibility
Searchpoint Optima Plus is available with HART® over 4-20mA output.
This communication aspect allows Searchpoint Optima Plus to deliver a wide
range of added value benefits.
What is HART®?
HART® (Highway Addressable Remote Transducer) is a widely used digital
communications protocol, which allows users to access live data, status
indications and diagnostic information from intelligent field devices. It works by
superimposing a digital signal on the existing analogue signal. A key benefit
of HART® is the fact no additional field cabling is required, because HART®
uses the device’s 4-20 mA signal cable. HART® can also help to reduce
costs in a number of ways. For example, it eliminates the need for proprietary
handheld devices; a field engineer can use a single HART® handheld device
to access any HART® enabled equipment on site. The HART® signal can be
interrogated from anywhere in the current loop, and this means that users can
access diagnostic information without going into the field. This means that if
maintenance is required, the scope of work is known before the engineer goes
to the device, potentially helping to reduce ongoing maintenance costs.
Searchpoint Optima Plus’ HART® interface speaks the
language of gas detection
Searchpoint Optima Plus’ HART® user interface is designed for gas detection
using familiar terminology. Honeywell Analytics’ engineers have designed
the Device Description (DD) file to provide easy to understand messaging on
HART® host devices, guiding the user through operations and eliminating time
wasted referring to manuals to “decode” generic HART® messages.
Searchpoint Optima Plus and its DD file are registered with the HART
Communication Foundation, having passed the Foundation’s rigorous test
program.
®
Available functions:
• View gas reading, configuration and diagnostic information
• Bump test
• mA loop calibration
• Gas calibration
• Simulate alarm, fault or warning
• Set device tag, ID and description
• View active warnings / faults and event history
• Force mA output to a set level for testing
• Configure real time clock
• Configure inhibit, warning and overrange levels
• Configure alarm threshold
• Change target gas
• Password protected access
Benefits of using HART
• Access full information from Searchpoint Optima Plus, anywhere in the
current loop
• No associated infrastructural costs, unlike some other communications
protocols; additional communication is achieved without the need for
extra cabling
• Save on set up costs by eliminating the need for proprietary handheld
devices
• Save on long-term costs by enabling proactive not reactive maintenance
• Save a field engineer investigation trip - “know before you go”
®
Page 5
Technical Summary
Searchpoint Optima Plus Specification
Measuring Range 0-100% LEL, wide selection of Hydrocarbon gas and vapour calibrations. Different measuring ranges and solvent
calibrations available for specialist applications
Signal Output 4-20mA autosensing sink or source
Inhibit 1-3mA (Default 2mA)
Warning 0-6mA (Default 3mA *)
Fault 0mA (HART
Over Range 20-21.5mA (Default 21mA)
Digital Output Optional Multidrop Modbus RS485 (via XNX, Optional HART
Material 316 stainless steel
EMC Compliance EN 50270:2006
Software EN 50271:2010
Marine Approvals Marine Equipment Directive (MED), type approvals from DNV, BV, ABS, Lloyd’s Register
* Note for ATEX compliance the warning value should not be set between 3 and 5mA
Installation Options
1
Hazardous Area
Safe Area
23
Hazardous AreaHazardous Area
Safe AreaSafe Area
45
Hazardous Area
-40°C to +65°C) IP66/67
amb
Safe Area
Hazardous Area
Safe Area
Power
4-20mA
Controller
4-20mA4-20mA
Standard HART
handheld device
Controller
®
HART
SCADA
®
Controller
4-20mA
4-20mA
Modbus
Controller
SCADA
DCS/PLC
Modbus
Modbus
Page 6
Honeywell Analytics Gas Detection
Honeywell Analytics is able to provide gas detection solutions to meet the requirements of all
applications and industries. Contact us in the following ways:
Headquarters
Europe, Middle East, Africa
Life Safety Distribution AG
Javastrasse 2
8604 Hegnau
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
gasdetection@honeywell.com
Customer Service:
Tel: 00800 333 222 44
Tel: +41 44 943 4380 (Alternative number)
Fax: 00800 333 222 55
Middle East Tel: +971 4 450 5800 (Fixed Gas Detection)
Middle East Tel: +971 4 450 5852 (Portable Gas Detection)
(Freephone number)
Technical Support Centres
Honeywell Analytics Ltd.
4 Stinsford Road
Nufeld Industrial Estate
Poole, Dorset, BH17 0RZ
United Kingdom
Tel: +44 (0) 1202 645 544
Fax: +44 (0) 1202 645 555
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or
omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently
issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.