Honeywell LYNXR-2SIA System User Manual

LYNXR-2 Series
Security System
User Guide
READY
OFF
1
2
3
8
TEST
VOLUME
CHIME
FUNCTION
BYPASS
9
PLAY
6
AUX
SELECT
STAY
DELETE
ESCAPE
AWAY
ADD
RECORD
45
LIGHTS ON
7
LIGHTS OFF
STATUS
NO DELAY
CODE
0
K15012 7/08 Rev. A
Your Honeywell security system is designed for use with devices manufactured or approved by Honeywell for use with your security system. Your Honeywell security system is not designed for use with any device that may be attached to your security system's keypad or other communicating bus if Honeywell has not approved such device for use with your security system. Use of any such unauthorized device may cause damage or compromise the performance of your security system and affect the validity of your Honeywell limited warranty. When you purchase devices that have been manufactured or approved by Honeywell, you acquire the assurance that these devices have been thoroughly tested to ensure optimum performance when used with your Honeywell security system.
– 2 –
TABLE OF CONTENTS
TABLE OF CONTENTS
SYSTEM OVERVIEW................................................................................................................................5
Features ................................................................................................................................................. 5
General Operation.................................................................................................................................7
Quick View of System Functions ..........................................................................................................9
About the Master Keypad ................................................................................................................... 11
Master Keypad Definitions .................................................................................................................12
About the Display and Indicators....................................................................................................... 14
SECURING THE PREMISES ................................................................................................................15
Checking System Status .....................................................................................................................15
Arming the System..............................................................................................................................16
Entry/Exit Delays................................................................................................................................18
Disarming the System.........................................................................................................................19
Bypassing Protection Zones ................................................................................................................ 20
Panic Keys / Chime Mode....................................................................................................................21
USER FUNCTIONS .................................................................................................................................22
Paging Feature ....................................................................................................................................22
“Follow Me” Announcement Feature ..................................................................................................23
Using Powerline Carrier Device Commands (Lights On/Lights Off keys)........................................25
Message Recording/Playback/Volume Control ...................................................................................26
Aux Function .......................................................................................................................................28
Clock/Calendar ....................................................................................................................................29
Scheduling User Interface...................................................................................................................31
Remote Phone Control Feature...........................................................................................................36
Speaker Phone Feature....................................................................................................................... 38
Remote Services...................................................................................................................................40
FIRE ALARM SYSTEM...........................................................................................................................41
General Information............................................................................................................................ 41
National Fire Protection Association’s Smoke Detector Recommendations .....................................42
Emergency Evacuation........................................................................................................................43
SYSTEM FUNCTIONS ............................................................................................................................44
Security Codes .....................................................................................................................................44
Testing the System.............................................................................................................................. 45
Trouble Messages ................................................................................................................................46
Maintaining Your System...................................................................................................................47
SUMMARY OF AUDIBLE NOTIFICATION........................................................................................48
FCC STATEMENTS.................................................................................................................................50
OWNER’S INSURANCE PREMIUM CREDIT REQUEST ................................................................55
LIMITATIONS OF THIS ALARM SYSTEM ........................................................................................57
INDEX ........................................................................................................................................................61
ONE YEAR WARRANTY ........................................................................................................................63
Congratulations on your ownership of a Honeywell Security System. You have made a wise decision in choosing it, for it represents the latest in security protection technology today. Honeywell is the world's largest manufacturer of security system, and millions of premises are protected by Honeywell products.
TABLE OF CONTENTSTABLE OF CONTENTS
– 3 –
– 4 –
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
Features
General Information
This system offers you three forms of protection: burglary, fire, and emergency, depending on the configuration of your system. The system consists of a master keypad for controlling system operation, various wireless sensors that provide perimeter and interior burglary protection, and optional smoke or combustion detectors to provide early fire warning. In addition, optional wireless keypads may have been installed to allow you to control the system away from the master keypad. The system may also be controlled from a remote telephone and can be used as a speaker phone. The system uses microcomputer technology to monitor all protection zones and system status, display appropriate information on the keypad display, and initiate appropriate alarms. Your system may also have been programmed to automatically send alarm or status messages over the phone lines to a central alarm monitoring station, and may also be capable of two-way voice communication with the central station. Certain features apply only to LYNXR-2SIA version of the control.
The user features of this security system are listed below. Ask your installer which features have been programmed for your system.
STAY and AWAY arming modes: By using these modes you can protect either the perimeter only,
or the entire premises.
3 panic key functions: Designated keys allow you to manually activate fire, personal emergency, or
silent alarms. Refer to the PANIC KEYS section for detailed information.
Paging feature: If programmed by your installer this feature alerts you to certain system conditions
by displaying code numbers that indicate the type of condition that has occurred. In addition, pressing the AUX key can send a predefined message to your pager, if programmed to do so (see AUX key function below). Refer to the PAGING FEATURE section for detailed information.
Follow me system announcements: Allows the LYNXR-2 Series to dial a number, programmed
by your installer, and deliver system announcements.
Follow me reminder announcements: Allows the LYNXR-2 Series to dial a number that you
have specified, at a programmed time and day and deliver a message programmed by your installer.
Real-time clock: Keypad displays current time. Refer to the CLOCK/CALENDAR section for
procedures for setting the time.
Voice announcement of system status: The master keypads built-in speaker announces system
status at the press of a key. Refer to the CHECKING SYSTEM STATUS section for detailed information.
Message center: The system allows recording and play back of brief messages. Refer to the
RECORDING/PLAYBACK MESSAGES section for procedures.
Device activation: Designated keys allow you to turn lights and/or other devices on and off. In
addition, some devices (e.g., a light) may be programmed to activate automatically as a result of a system event such as an alarm or trouble condition. Refer to the USING POWERLINE CARRIER DEVICE COMMANDS section for detailed information.
AUX key function: Designated key lets you activate a predefined series of keystrokes with a single
press of the
manually send a voice message to phone number that has been programmed by your installer. Ask
your installer which of these features has been assigned to the
the AUX FUNCTION section for detailed information.
AUX key plus user code, or manually send a pager message. It will also allow you to
AUX key in your LYNXR-2. Refer to
– 5 –
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
Features
Scheduling feature: Allows you to schedule the automatic activation or deactivation of X10 devices
or program events (e.g. alarm clock, reminder, and latch key).
Two-way voice: Allows the central station to listen, talk to or conduct two-way conversations with
individuals on the premises Refer to the TWO-WAY VOICE section for detailed information.
Phone Control: Provides a remote interactive phone capability that permits access to the security
system from any off-site touch-tone telephone.
Speaker Phone Operation: The system is capable of operating as a speaker phone allowing hands
free telephone conversation.
Security Codes: The system is capable of supporting an Installer code, Master user code and six
additional User codes including Babysitter and Duress codes. Refer to the SECURITY CODES section for detailed information.
LYNXR-2SIA False Alarm Prevention Features
Many false alarms are caused by simple accidents, like forgetting to close a door when you leave. The LYNXR-2SIA includes several features that help prevent false alarms and some of these are optional or programmable. Although turning off some of these features may provide additional security, it may also increase the chance of false alarms. Your installer can help you decide whether to use the features or not. The following provides a brief explanation of the features included with your security system that help prevent false alarms from occurring, and what you should do if such alarms occur.
Exit/Entry Delays: Your security system has been programmed with delay times that allow you to
exit the premises after arming, and to disarm the system upon entry, before an alarm occurs. If you leave the premises too late when exiting, or disarm too late when arriving home, it will cause a false alarm. If an alarm occurs, you should disarm the system immediately, and wait for your monitoring company to call you.
Exit Alarms: Leaving the premises and forgetting to close the door is a common cause of false
alarms. The security system will sound an alarm, and display EA, indicating, exit alarm. The security system provides extra time for you to disarm the system before dialing your monitoring company. Disarming the system immediately may prevent a call to your monitoring company.
Exit Time Restart-Exit Delay Restart/Reset: If you leave the premises and enter again before the
exit delay has expired, the system will restart the exit time giving you more time to leave. If there are less than 10 seconds left to exit, the system will sound fast beeps, indicating an alarm will occur soon if you fail to exit or disarm immediately. If this occurs, disarm the system and arm it again when you are ready to leave. The Exit Delay can also be restarted by entering CODE + STAY.
Auto Stay Feature: If you arm the system in the “AWAY mode from the controls keypad or an RF
keypad but no one exits, the alarm system will automatically change to the “STAY” mode. This will prevent you from tripping alarms by remaining on premises. Disarm the system and arm away again when you are ready to leave.
Burglary Abort Window: Your security system has a delay between the time a burglary alarm
sounds, and the time the monitoring company is called. This delay gives you time to disarm the security system before the alarm is reported to the monitoring company. This delay is factory preset at 30 seconds, but may be increased or decreased by your installer.
False Alarms: If a burglary or fire alarm condition occurs and the system has been disarmed, the
keypad will display “CA” or cancel. If this was a false alarm, wait for the monitoring company to call you. They will verify your security code or password and prevent them from calling emergency personnel to respond to a false alarm.
– 6 –
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
General Operation
Zones
Your system's sensing devices have been assigned to various "zones." For example, the sensing device on your entry/exit door may have been assigned to zone 01, sensing devices on windows in the master bedroom to zone 02, and so on. These numbers appear on the display when an alarm or trouble condition occurs.
Fire Protection
The fire protection portion of your security system (if used) is always active and will sound an alarm if a fire condition is detected. Refer to the FIRE ALARM SYSTEM section for important information concerning fire protection, smoke detectors and planning emergency exit routes from the premises.
UUUULLLL
Burglary Protection
Your system provides two modes of burglary protection: STAY and AWAY. STAY mode protects the perimeter only, allowing you to freely move inside the premises. AWAY mode protects the entire system. Both modes provide an entry delay time that allows you to reenter the premises without setting off an alarm. For additional security, you can turn the entry delay off when arming the system by using
the
selected zones before arming the system, if desired. Refer to the BYPASSING PROTECTION ZONES section. The system also provides a CHIME mode, for alerting users to the opening of protected doors and windows while the system is disarmed.
You must turn on ("arm") the burglary protection portion of your system before it will sense burglary alarms. To arm the system, enter your user code then press the desired arming key (AWAY or STAY). Refer to the ARMING THE SYSTEM section for detailed procedures and information.
LYNXR-2 Series is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC) is installed.
NO DELAY key in combination with the desired arming key. The system also allows you to bypass
Security Codes
At the time of installation, you were assigned a personal 4-digit security or master user code. You must enter the user code when arming and disarming the system, and when performing other system functions. As an additional security feature, other users who do not need to know your code can be assigned up to 6 different security codes. Refer to the SECURITY CODES section for procedures on adding security codes to the system.
Alarms
When an alarm occurs, the keypad and external sounders will sound for about 15-seconds, and the keypad will display the zone(s) causing the alarm. After 15-seconds, the siren stops temporarily and voice announcements of the zones in alarm begins. When these zones have been announced, the siren sounds again and the cycle repeats itself, until the system is disarmed (CODE + OFF) or until alarm bell timeout occurs. If your system is connected to a central monitoring station, an alarm message will be sent. To stop the alarm sounding, simply disarm the system. The zone(s) causing the alarm remain displayed indicating memory of alarm. Refer to the DISARMING THE SYSTEM section for information about clearing the memory of alarm display
– 7 –
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
General Operation
LYNXR-2SIA False Alarm Prevention Feature
Note that in cases of alarm, the LYNXR-2SIA may disarm as soon as the security code is entered, or you can still enter CODE + OFF. If your system is connected to a central monitoring station, an alarm message will be sent. To reduce false alarms, message reporting is delayed 30 seconds. The delay can be reduced to 15 seconds, or increased up to 60 seconds at your option. Consult with your installer to ensure that the correct delay has been programmed. To stop the alarm sounding, simply disarm the system. The zone(s) causing the alarm remain displayed indicating memory of alarm. Refer to the DISARMING THE SYSTEM section for information about clearing the memory of alarm display.
Two-Way Voice Feature
The LYNXR-2 Series supports voice dialog between an operator at the central station and an individual at the premises. This feature allows the central station to listen, talk to or conduct a two-way conversation with an individual(s) at the premises and allows the operator to gather information about the nature and location of the alarm that may be helpful in responding to police or rescue departments. If the Two-way Voice Feature has been programmed and an alarm condition is detected, the system sends an alarm message to the central station. After acknowledgement is received, a listen in to follow message is sent to the central station. In response to this message, the central station operator can enter commands that allow him to initiate a 5-minute voice session. The options allow the operator to enter the following modes:
Talk: Allows the operator to speak to individuals at the premises through the system speaker.
VOX (2-way voice): Allows the operator to hold a two-way (speak and listen) conversation with
individuals at the premises.
Listen: Allows the operator to listen to any activity at the premises through the system microphone.
If a subsequent zone is violated during a voice session, the system will terminate the session and process the alarm. During the voice session, the ARMED (red) and READY (green) LEDs will alternately blink in the Talk and VOX Modes but not during Listen Mode.
– 8 –
QUICK VIEW OF SYSTEM FUNCTIONS
y
QUICK VIEW OF SYSTEM FUNCTIONS
QUICK VIEW OF SYSTEM FUNCTIONSQUICK VIEW OF SYSTEM FUNCTIONS
NOTE: = Boxes represent the entering of your 4-digit user code.
SECURITY FUNCTIONS
Checking system status: --------------------- STATUS
To arm in STAY mode: ----------------------
To restart exit delay: -------------------------
To arm in AWAY mode: ---------------------
To arm with NO DELAY: -------------------
*
+ STAY
*
+ STAY OR STAY
*
+ AWAY
*
+ AWAY or STAY + NO DELAY
(only if programmed and system is armed
mode.)
in Sta
To arm if Quick Arm is active: ----------- AWAY or STAY (hold down for at least 2 seconds)
To disarm system and silence alarms: + OFF
Note: During Entry Delay or when an Alarm Condition exists, the LYNXR-2SIA can be disarmed by entering the User
Code. Entering the OFF key is not required
To bypass a zone(s): --------------------------- + BYPASS + 2-digit zone number(s)
To turn Chime mode on or off: ----------- FUNCTION + CHIME
*
Security code is not required if Quick Arm is active. Instead, press and hold down the STAY
or AWAY key.
MESSAGE CENTER
To record a message: ------------------------- FUNCTION + RECORD
To stop recording before end of 85 secs: OFF
To play back a message: --------------------- FUNCTION + PLAY
To skip a message:----------------------------------- []
To delete all messages: --------------------------- FUNCTION + DELETE (during message replay)
VOLUME ADJUSTMENT
To adjust message playback/announcement volume: FUNCTION + VOLUME + [3] or [6]
To mute system announcements: ------- FUNCTION + VOLUME + OFF
To restore/unmute announcements:---- FUNCTION + VOLUME + [3] or [6]
SPEAKER PHONE OPERATION
To enter speaker phone mode: ----------- [#] + AUX
To exit speaker phone mode: ------------- OFF
To enable/disable (toggle) ringer: ------ [#] + VOLUME + AUX
To return keypad to telephone mode (after clearing an alarm or trouble or disarming the system): [#] + AUX
To flash (switch back and forth between two calls using call waiting): AUX
(wait at least two (2) seconds before pressing AUX again)
– 9 –
QUICK VIEW OF SYSTEM FUNCTIONS
QUICK VIEW OF SYSTEM FUNCTIONS
QUICK VIEW OF SYSTEM FUNCTIONSQUICK VIEW OF SYSTEM FUNCTIONS
REMOTE PHONE CONTROL OPERATION
To remotely disarm: --------------------------------- + [1]
To remotely arm in AWAY mode: -------------- + [2]
To remotely arm in STAY mode: --------------- + [3]
To remotely arm in AWAY or STAY mode with NO DELAY: + [2] or [3] + [0]
To remotely activate X10 devices 01-06: ---- [#] + [4] + (2-digit) device no.
To remotely activate X10 devices 07 & 08:- + [#] + [4] + (2-digit) device no.
To remotely deactivate X10 devices 01-06: [#] + [7] + (2-digit) device no.
To remotely deactivate X10 devices 07 & 08: + [#] + [7] + (2-digit) device no.
To remotely bypass a zone: ---------------------- + [6] + zone no.
To remotely activate forced bypass: --------- + [6] + [#]*
To remotely check system status: ------------- [*]
To hang up: ---------------------------------------------- + [9]
*If forced bypass was enabled by your installer.
OTHER FUNCTIONS
To set the time and date: -------------------------- + FUNCTION + [63]
To set scheduling: ------------------------------------ + FUNCTION + [64]
To activate X10 devices 01-06:------------------- FUNCTION + LIGHTS ON + (2-digit) dev. no.
To activate X10 devices 07 & 08: +FUNCTION +LIGHTS ON + (2-digit) dev. no.
To deactivate X10 devices 01-06:................... FUNCTION + LIGHTS OFF + (2-digit) dev. no.
To deactivate X10 devices 07 & 08: +FUNCTION +LIGHTS OFF + (2-digit) dev. no.
To add a user code:
To delete a user code (except Master Code): .....
**
+ CODE + user no. (02-08)+ user code
**
+ CODE + user number (02-08)
To turn Test mode on: ------------------------------ + TEST
To turn Test mode off: ----------------------------- + OFF
To use the defined AUX function: - Press and hold AUX key 2 seconds (4 beeps) +
To send message to pager: ------------ Press and hold AUX key 2 seconds (4 beeps)
To program Follow Me reminder phone no: +FUNCTION + [65] + Enter up to 24
digits
To delete Follow Me reminder phone no: + FUNCTION + [65]
** Only the master code can be used to add or delete another user code.
– 10 –
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
About the Master Keypad
General
IMPORTANT: If the keypad beeps rapidly upon entering the premises, an alarm has occurred during your absence and an intruder may still be on the premises. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location.
The keypad allows you to control all system functions. In the speaker phone mode the keypad becomes a full-function telephone keypad. The keypad features telephone-style keys and a Liquid Crystal Display (LCD), which shows the nature and location of all occurrences.
The keypad also features a built-in sounder, which will sound during alarms and troubles. The keypad also "beeps" during certain system functions, such as during entry/exit delay times, in Chime mode, and when depressing any of the keys (to acknowledge the key press). In addition, a built-in speaker announces system status. The voice announcement volume is adjustable, however the “beeps” that sound in response to alarms always sound at the maximum volume level. All other “beeps” (trouble, chime, exit/entry, etc) can be set to either low or high volume.
– 11 –
09015-001-V0
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
Master Keypad Definitions
20
21
1
2
19
ARMED
OFF
1
18
17
ESCAPE
AWAY
STAY
DELETE
AUX
SELECT
ADD
RECORD
4
LIGHTS ON
7
LIGHTS OFF
STATUS
VOLUME
TEST
CODE
NO DELAY
2
5
8
0
FUNCTION
16
15
14
13
IMPORTANT!
When you use the keypad to enter codes and commands, press the keys within 2 seconds of one another. If 2 seconds elapse without a key depression, the entry is aborted and must be repeated from its beginning.
NOTE: Different timeouts may occur when defining auxiliary functions and setting the real-time clock.
12
PLAY
BYPASS
CHIME
11
READY
3
6
9
3
4
5
6
7
8
9
10
09015-003-V0
Note: The system functions described below are for reference only and require additional key entries to activate.
1. DISPLAY WINDOW: Liquid Crystal Display
(LCD). Displays protection point identification and system status, messages, and user instructions.
2. ARMED INDICATOR: (RED) Lit when the
system has been armed (STAY, AWAY, NO DELAY). Blinks when armed and fault exists, or once per second when AVM (VOX or Talk) or speaker phone mode is active.
– 12 –
3. READY INDICATOR: When lit, indicates
system is ready to be armed; blinking indicates system is not ready (a zone is open). Blinks once per second when AVM (VOX or Talk) or speaker phone mode is active.
4. PLAY
KEY: Announces a user’s message if
one was previously recorded. See RECORD function. Used to adjust volume of voice messages.
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
Master Keypad Definitions
5. TEST
6. BYPASS
7. CODE
8. CHIME
9. INTERNAL SOUNDER: Source of alarm sounds
10. FUNCTION
11. NO DELAY
12. STATUS
13. LIGHTS ON
14. AUX
KEY: Tests the system and alarm
sounder.
KEY: Removes individual protection
zones from being monitored by the system. Displays currently bypassed zones. Used to adjust volume of voice messages.
KEY: Allows entry of additional user
codes that can be given to other system users.
KEY: Turns the Chime mode on and
off. When on, any entry through a protected delay or perimeter zone while the system is disarmed will cause a tone and voice descriptor to sound at the keypad.
(see "Summary of Audible Notifications" section).
KEY: Allows alternate key
functions. It is used as a “repeat” key during Clock/Calendar setting.
KEY: Used with STAY or AWAY
function to eliminate the entry delay. Alarm sounds immediately if entry is opened.
KEY: When pressed prior to arming,
the keypad will display all open zones, and will announce system status.
/ LIGHTS OFF KEYS: Turns
lights or other devices on or off, if programmed by the installer.
/ SELECT KEY: Can be programmed
to either perform a predefined function or to send a preset message to a pager or a Follow Me system phone number.
15. STAY
16. AWAY
17. OFF
18. MICROPHONE: Used to record personal
19. SPEAKER: Source of audible internal warning
20. RECORD: Activates the recording function to
21. VOLUME: Sets the volume of system
–– KEYS 0-9: Used to enter your individual
/ DELETE KEY: Arms the perimeter
burglary protection, guarding protected doors, windows and other perimeter protection points, and sounds an alarm if one is opened. Interior protection is not armed, which allows movement within your house without causing an alarm. Entrance can be made through an entry delay zone without causing an alarm if the system is disarmed before the entry delay time expires. Used to delete messages.
/ ADD KEY: Completely arms both
perimeter and interior burglary protection for backup protection by sensing an intruder's movements through protected interior areas as well as guarding protected doors, windows, etc. Entrance can be made through an entry delay zone without causing an alarm if the system is disarmed before the entry delay time expires. Used to accept Follow Me phone number and Clock/ Calendar mode entries.
/ ESCAPE KEY: Disarms the burglary
portion of the system, silences alarms and audible trouble indicators, and clears alarm trouble display after the problem has been corrected. Used to exit/abort “Follow Me” phone number and Clock/Calendar mode.
messages up to 85 seconds long, and for 2 way voice and speaker phone.
and confirmation sounds, status announcements, as well as alarms (see "Summary of Audible Notifications").
record personal messages.
announcements and status beeps.
security access code(s).
– 13 –
SYSTEM OVERVIEW
SYSTEM OVERVIEW
SYSTEM OVERVIEWSYSTEM OVERVIEW
About the Display and Indicators
LOW BAT AC
Display Definitions (for other displays, see Trouble Messages)
ALARM: Appears when the system is armed and an intrusion has been detected (also appears
during a fire alarm or audible emergency alarm). Accompanied by the protection zone that is in alarm.
AWAY: All burglary zones, interior and perimeter, are armed. INSTANT: Entry delay is turned off. STAY: Perimeter burglary zones, such as protected windows and doors, are armed.
UL
UL
ULUL
FIRE: Appears when a fire alarm or fire fault is present. Accompanied by a display of the
LOW BAT: Low battery condition in a wireless sensor (if zone number is displayed) or low system
AC: Appears when AC power is present. If not displayed, the system is operating on
CHIME: Appears when the Chime feature is activated. TEST: Appears when the system is in Test mode.
LYNXR-2SIA blinks during the last 5 minutes of test.
REC: Appears when the system is in Recording mode. MESSAGE: Appears when a message has been recorded and has not yet been played back. BYPASS: Appears when one or more burglary protection zones have been bypassed. FAULT: Appears at any time a malfunction is discovered in the system; or any time an open
PH: Appears in place of the clock when the speaker phone mode is active. PC: Appears during a remote phone control session.
LYNXR-2 Series is not intended for UL985 Household Fire applications unless a 24-hour backup battery (P/N LYNXRCHKIT-HC) is installed.
zone that is in alarm.
battery (if no zone number is displayed). If 00 is displayed, a wireless keypad (5827) has a low battery condition.
backup battery power.
is detected in a fire zone; or when a fault in a day/night burglary zone is discovered during a disarmed period. Accompanied by a display of the zone number in trouble.
LED Meanings
ARMED LED: ON = System armed (Red) OFF = System disarmed Blinking = System armed, but a fault exists Blinking alternately with READY LED = AVM (VOX or Talk) or speaker phone mode
is active
READY LED: ON = System disarmed, ready to arm (Green) OFF = System armed Blinking = System disarmed, not ready to arm (a fault exists) Blinking alternately with ARMED LED = AVM (VOX or Talk) or speaker phone
mode is active.
ALARM
AWAY
INSTANT
STAY
FIRE
CHIME TEST
REC MESSAGE
FAULT
BYPASS
– 14 –
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Checking System Status
General Information
Before arming your system, all protected doors, windows, and other protection zones must be closed or
bypassed (see the BYPASSING PROTECTION section). Pressing the STATUS key will announce all
zones that are faulted, as well as any other abnormal system condition, making it easier for you to secure any open zones.
READY LIGHT: The green READY indicator on the keypad will be lit if the system is ready to be
Press the STATUS Key
Press the STATUS key once to announce the general status of the system.
Depending on the current state of the system the following phrases may be heard:
disarmed, ready to arm [message] [check system] disarmed, [not ready to arm], [message] armed [away] [stay] [instant] [check system] [message]
NOTE: The phrases shown in brackets are variable, and are announced only if appropriate in the current state of the
Press the STATUS key a second time† to announce specific system status.
Depending on the current state of the system the following phrases may be heard:
fire alarm [zone voice descriptors] carbon monoxide alarm [zone voice descriptors]
alarm [zone voice descriptors] fire fault [zone voice descriptors]
carbon monoxide fault [zone voice descriptors] fault [zone voice descriptors] low battery [zone voice descriptor] system low battery check system AC loss zones bypassed
chime
VOLUME LEVEL: The volume level of system announcements can be increased or decreased. Refer to the MESSAGE RECORDING/PLAYBACK section for the procedure.
system.
System Can Be Armed
The READY LED will be lit once all protection zones have been closed or bypassed. You may now arm the system as usual.
armed. If blinking, the system is not ready.
(second depression must be made within 10 seconds of the first)
– 15 –
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Arming the System
Arming in Stay Mode
Use this mode when you are staying home, but expect someone to use the entrance door later. Close all protected perimeter windows and doors before arming. The green READY indicator on the keypad should be lit if the system is ready to be armed.
To arm in STAY mode:
Your User code**
** See Quick Arming paragraph.
+ STAY
The keypad beeps three times and displays the armed STAY message. The red ARMED indicator lights and the system announces armed STAY–exit now.”
When armed in STAY mode, the system will sound an alarm if a protected door or window is opened, but you may otherwise move freely throughout the premises. Late arrivals can enter through the entrance door without causing an alarm, but they must disarm the system within the entry delay period or an alarm will occur.
Restarting Exit Delay While System Armed
Ask your installer if this feature is active for your system. If active, you can restart the exit delay at
any time after arming in STAY mode by entering the User Code and pressing the
by pressing the STAY key by itself. This avoids having the user disarm then re-arm the system after
allowing someone to enter or exit.
Exit Delay Restart/Reset
On the LYNXR-2SIA, this option also enables automatic exit delay reset, which resets exit delay if the entry/exit door is re-opened and closed before exit delay time expires after arming. Automatic Exit Delay Reset occurs only once during an armed period.
To restart exit delay while system is armed in STAY mode: Press STAY
or press and hold
STAY **
STAY key, or simply
key.
Arming In Away Mode
Use this mode when no one will be staying on the premises. Close all protected perimeter windows and doors before arming. The green READY indicator on the keypad should be lit if the system is ready to be armed.
To arm in AWAY mode:
Your User Code **
** See Quick Arming paragraph.
The keypad beeps twice, or beeps continuously if exit warning has been programmed for your system, and displays the armed AWAY message. The red ARMED indicator lights and the system announces armed AWAY–exit now.
When armed in AWAY mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises. You may leave through the entrance door during the exit delay period without causing an alarm. You may also re-enter through the entrance door, but you must disarm the system within the entry delay period or an alarm will occur.
+ AWAY
or press and hold
– 16 –
AWAY **
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Arming the System
Auto Stay Feature
If this feature is enabled by installer, the LYNXR-2SIA, when armed AWAY from the controls keypad or a Wireless Keypad, switches to the STAY mode if the Exit Time expires and no exit has been made.
NOTE: If the exit route entry/exit sensor is in a check condition or has been bypassed it will result in a loss of interior
Arming the System with No Delay
Use NO DELAY with STAY mode when you are staying home and do not expect anyone to use the entrance door.
Use NO DELAY with AWAY mode when the premises will be vacant for extended periods of time such as vacations, etc.
When armed with NO DELAY, the system will sound an alarm if a protected door or window is opened, including the entrance door. You may leave through the entrance door during the exit delay period without causing an alarm, but an alarm will sound as soon as someone reenters.
To arm with NO DELAY:
Your user code**
** See Quick Arming paragraph.
Quick Arming
If Quick Arm was programmed by the installer, you do not need to enter the security code to arm the system. Instead, simply press and hold down the desired arming key for at least 2 seconds. The security code must always be used to disarm the system, however.
To arm if Quick Arm is active:
To arm with NO DELAY if Quick Arm is active:
least 2 seconds
IMPORTANT: The Babysitter Code and Installer Code cannot disarm the system unless it was used to arm the system. In addition, if the system is armed by pressing and holding the Quick-Arm buttons, neither the Babysitter Code nor Installer Code can disarm the system.
protection because the alarm system will arm STAY in this case. Consult with your installer for servicing of the entry exit zones or to turn off this feature if a check condition on entry exit zones occurs.
+ AWAY
or
AWAY
STAY
or
hold down for at least 2 seconds
AWAY
STAY
or
+
STAY
NO DELAY
then
NO DELAY
hold down for at
– 17 –
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Entry/Exit Delays
Exit Delay
Exit delay begins immediately after arming the system, and gives you time to leave through the designated exit door without setting off an alarm. A slow beeping will sound throughout the exit delay period, if programmed. During the last 10 seconds of the exit delay fast beeps will sound as a warning that the delay time is nearing its end. The exit beeps cannot be silenced.
Exit Alarms Exit Alarm Active To minimize false alarms sent to the alarm monitoring company, your system may have been programmed for this feature. Ask your installer if Exit Alarm is active for your system. Whenever you arm the system, the exit delay begins. If an entry/exit door or interior zone is faulted when the exit delay ends (e.g., exit door left open), the system sounds an alarm and starts the entry delay timer. If you disarm the system before the entry delay ends, the alarm sound stops and the message "CA" is displayed on the keypad, along with a zone number indicating the faulted zone. No message is sent to the alarm monitoring company. To clear the exit alarm condition, the open zone
must be made re-secured; to clear the display, enter your security code and press the
If you do not disarm the system before the entry delay ends, and an entry/exit door or interior zone is still open, the alarm sound continues and an "exit alarm" message is sent to the alarm monitoring company. The message "EA" is displayed on the keypad, along with a zone number indicating the faulted zone. The alarm will continue to sound until the system is disarmed or timeout ocurs. To stop
the alarm, the system must be disarmed by entering your security code and pressing the
the message "CA" is displayed on the keypad, indicating that the alarm has been cancelled (if this
feature is enabled by the installer). To clear the display, enter your security code and press the
key a second time. An exit alarm also results if an entry/exit door or interior zone is faulted within two minutes after the end of the exit delay.
OFF key.
OFF key; and
OFF
Entry Delay
Entry Delays give you time to disarm the system when you re-enter through the designated entrance door. You must disarm the system before the entry delay period ends, or an alarm will occur. The keypad beeps during the entry delay period, reminding you to disarm the system. There are two entry delays (if programmed). The first is for your primary entrance and the second can be used for a secondary entrance, where a longer delay is required to walk to the keypad to disarm the system. You
can also arm the system with no entry delay at all by using the
provide greater security while on the premises or while away for extended periods of time. See ARMING THE SYSTEM section for procedure. See your installer for delay times programmed for your system.
Exit Delay:
00-99 seconds
NO DELAY key when arming. This can
Entry Delay 1: 00-99 seconds Entry Delay 2: 00-99 seconds
LYNXR-2SIA Exit/Entry Delay Times
Exit Delay: 45-96, 120 seconds
Entry Delay 1: 30-96, 120, 180, 240 seconds Entry Delay 2: 30-96, 120, 180, 240 seconds
– 18 –
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Disarming the System
NOTE: The control will provide a long confirmation ding when it is disarmed using an RF Key Fob.
Use the
OF AUDIBLE NOTIFICATION section for information, which will help you to distinguish between fire and burglary alarm sounds.
If you return and the main burglary sounder is on, DO NOT enter the premises, but call the police from a nearby safe location. If you return after an alarm has occurred and the main sounder has shut itself off, the keypad will beep rapidly upon entering. This indicates that an alarm has occurred during your absence and an intruder may still be on the premises. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location.
To disarm the system and silence burglary alarms: + OFF
Your user code
During Entry Delay or when an Alarm Condition exists, the system will be disarmed as soon as the correct user code is entered on the keypad. Entering the OFF key is not required. The entry beeps or alarm sound can be silenced by pressing any key however, it will restart in 10 seconds if the correct User Code is not entered.
The READY indicator will light (if no alarms have occurred while armed) and the keypad will beep once to confirm that the system is disarmed.
OFF key to disarm the system and to silence alarm and trouble sounds. See the SUMMARY
**IMPORTANT**
Memory of Alarm
If an alarm occurs, the keypad displays the zone number (s) that caused the alarm and the type of alarm (e.g., FIRE ALARM). These messages remain displayed until cleared by a user.
To clear the display, note the zone number displayed and enter an OFF sequence (enter your security
code and press the
If the READY indicator is blinking, go to the displayed zone and correct the fault (close windows, etc.). If the fault cannot be corrected, notify your alarm company.
OFF key).
– 19 –
SECURING THE PREMISES
SECURING THE PREMISES
SECURING THE PREMISESSECURING THE PREMISES
Bypassing Protection Zones
Bypassing Individual Zones
Use the BYPASS key when you want to arm your system with one or more zones intentionally
unprotected. Bypassed zones are unprotected and will not cause an alarm when violated while your system is armed. All bypasses are removed when an OFF sequence (security code plus OFF) is performed. Bypasses are also removed if the arming procedure that follows the bypass command is not successful.
The system will not allow fire zones to be bypassed.
The system must be disarmed first.
To bypass a zone(s): + BYPASS
Your user code bypassed (e.g., 02, 03, etc.)
Important! All single-digit numbers must be preceded by a zero (for example, enter 02 for zone 2).
The keypad will provide a confirmation beep and display the word “BYPASS” along with each bypassed zone number. Wait for these zones to be displayed, to be sure that intended zones are bypassed.
Arm the system as usual when the keypad displays the READY LED on steady.
+ 2-digit zone number(s)
Forced Bypass
Your system may allow you to easily bypass all open (faulted) zones without having to enter zone numbers individually. Ask your installer if this feature is active.
+
To bypass a zone(s):
Your user code
In a few moments, all open zones will be displayed along with the word “BYPASS.” Wait for these zones to be displayed before arming. Arming the system before zones are displayed eliminates all bypasses.
Arm the system as usual when the keypad displays the READY LED on steady.
Displaying Bypassed Zones
The system allows you to determine what zones have been previously bypassed. Bypassed zones can be displayed only when the system is disarmed, and when the “BYPASS” message described above is displayed.
To display bypassed zone(s):
Your user code
In a few moments, all open zones will be sequentially displayed along with the word “BYPASS.”
+ BYPASS
+ BYPASS
FUNCTION
+ WAIT
for zone(s) to be
– 20 –
Loading...
+ 44 hidden pages