2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
2345678901234567890123456789012123456789
The D330 Mixer is a medium duty 30 quart mixer which develops 11/4 horsepower and features a timer,
thermal overload protection, and a #12 attachment hub as standard equipment. A variety of agitators are
available for the 30 quart bowl. A special 20 quart bowl and agitators are available options.
Bowl Guard is standard equipment on all D330 models.
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
23456789012345678901234567890121234567890123456789012345678901212345678901
Installation, Operation, and Care of
MODEL D330 MIXERS
SAVE THESE INSTRUCTIONS
GENERAL
Programmable Timer Controller is optional on D330 models.
A variety of attachments and accessories are available for all mixers. These are described in a separate
Use and Applications Handbook
which is furnished with each mixer.
INSTALLATION
UNPACKING
Immediately after unpacking the mixer, check for possible shipping damage. If this machine is found to
be damaged, save the packaging material and contact the carrier within 15 days of delivery.
Prior to installation, test the electrical service to assure that it agrees with the specifications on the machine
data plate.
LOCATION
Place the mixer in its operating location. There should be adequate space around the mixer for the user
to operate the controls and install and remove bowls. The area above the mixer should allow the top cover
to be removed for routine maintenance and servicing.
Holes are provided in the base for permanent bolting to the floor, although this is not necessary in normal
installations. Four plastic plugs are supplied with the mixer to plug these holes if they are not used.
– 3 –
ELECTRICAL CONNECTION
WARNING: ELECTRICAL AND GROUNDING CONNECTION MUST COMPLY WITH THE
APPLICABLE PORTION OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT.
ELECTRICAL DATA
Models Volts / Hz / Ph
D330 120 / 60 / 1 25.0 35 35 8 35 35 8
D330 208 / 60 / 1 14.0 20 20 12 20 20 12
D330 240 / 60 / 1 12.5 20 20 12 20 20 12
D330 208 / 60 / 3 5.0 15 6 14 15 10 14
D330 240 / 60 / 3 5.0 15 6 14 15 10 14
D330 480 / 60 / 3 2.5 15 3 14 15 6 14
Circuit Size (Minimum) & Fuse / Circuit Breaker Size (Maximum) compiled in accordance with the National Electrical Code (ANSI/NFPA 70), 1993 Edition.
Rated
Amps
Circuit Size
(Amps)
* Dual Element
Fuse Size *
(Amps)
Time-Delay Fuse
60°C Copper
Wire Size
Circuit Size
(Amps)
** Inverse Time
Circuit Breaker **
(Amps)
Circuit Breaker
60°C Copper
Wire Size
A hole for
3
⁄4" trade size conduit is located at the top
of the pedestal (Fig. 1). Make electrical connections
per the wiring diagram located on the inside of the Top
Cover.
Fig. 1
Check Rotation (Three-Phase Machines Only)
Three-phase machines must be connected so the planetary rotates in the direction of the arrow on the Drip
Cup. To check rotation:
Set the gear shift lever on 1.
Apply power to the mixer, set the Electro-Mechanical Timer on HOLD; or, if equipped with a
Programmable Timer Controller, set it on [ -- : -- ]. With the Bowl Support all the way up, momentarily
run the machine by pushing the START and then STOP buttons.
If rotation is incorrect, DISCONNECT ELECTRICAL POWER SUPPLY and interchange any two of
the incoming power supply leads.
– 4 –