Hobart HRW2S User Manual

Page 1
Item # _____________________________________
Quantity ___________________________________
C.S.I. Section 11400
HRW2S SERIES
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
Modular panel construction
Cam lock attachment
Stainless steel interior and exterior
Self-contained refrigeration system for units with
depth of 37.75"
OPTIONS
Refrigeration R22 R134A R404
Stainless steel floor
Pass thru
TWO WIDE RETARDER
MODEL CONFIGURATIONS
37.75" Interior Depth Two Door – (may be
shipped assembled) Three Single End or Four Single Side Load Racks or Two Double Racks
77.75" Interior Depth Two Door – Eight Single
End or Eight Single Side Load Racks or Four Double Racks
117.75" Interior Depth Two Door – Twelve
Single End or Twelve Single Side Load Racks or Six Double Racks
Specifications, Details and Dimensions on Inside and Back.
ACCESSORIES
Side trim One side Both sides
Interior light
Rear trim
HRW2S SERIES TWO WIDE RETARDER
F-40145 – HRW2S Series Two Wide Retarder Page 1 of 4
Page 2
HRW2S SERIES
37.75" Interior Depth Plan View
37.75" Interior Depth Side View
77.75" Interior Depth Plan View
77.75" Interior Depth Side View
TWO WIDE RETARDER
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
37.75" Interior Depth Front View
77.75" Interior Depth Front View
1 Water Supply 85" AFF 2 Electrical Supply 85" AFF 3 Drain 5" AFF Front or Rear
Page 2 of 4 F-40145 – HRW2S Series Two Wide Retarder
Page 3
HRW2S SERIES
117.75" Interior Depth Plan View
117.75" Interior Depth Side View
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
117.75" Interior Depth Front View
TWO WIDE RETARDER
1 Water Supply 85" AFF 2 Electrical Supply 85" AFF 3 Drain 5" AFF Front or Rear
F-40145 – HRW2S Series Two Wide Retarder Page 3 of 4
Page 4
Printed On Recycled Paper
HRW2S SERIES TWO WIDE RETARDER
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
SPECIFICATIONS
GENERAL:
37.75" Interior Depth Two Door – (may be shipped
assembled) Three Single End or Four Single Side Load Racks or Two Double Racks
77.75" Interior Depth Two Door – Eight Single End or Eight Single Side Load Racks or Four Double Racks
117.75" Interior Depth Two Door – Twelve Single End or Twelve Single Side Load Racks or Six Double Racks
CONSTRUCTION: Stainless steel interior and exterior is standard. The interior perimeter is supplied with bumpers on all sides to protect the finish.
CAPACITY: Door opening will accommodate 74" high racks.
INSULATION: The retarder cabinet is rigid and formed of stainless steel panels with polyurethane foam insulation and sealed with gaskets to form a strong, energy efficient, tight and sanitary enclosure.
HARDWARE AND FITTINGS: Heavy-duty, plastic­coated door handles positioned horizontally. Positive action door closure.
FREIGHT CLASS: 85
For proper installation, floor should be level within
1
8" per foot not to exceed 3⁄4".
DETAILS AND DIMENSIONS
NOTE: The 37.75" interior depth unit has self contained refrigeration system with a single evaporator. The 77.75" and
117.75" interior depth units have 2 evaporators and require remote refrigeration to be charged on-site. The recom­mended water hardness range is 2-4 grains per gallon. The recommended pH range is 7.0 to 8.0. The acceptable range for chloride concentration is 0-30 ppm. Consult your local water company and/or water conditioner dealer before using water on this equipment.
PHYSICAL DATA 37.75" INTERIOR DEPTH 77.75" INTERIOR DEPTH 117.75" INTERIOR DEPTH
Interior Dimensions 74.5" H x 37.75" D x 66" W 74.5" H x 77.75" D x 66" W 74.5" H x 117.75" D x 66" W
Rack Capacity
Net Door Opening Height 74.5" STD 74.5" STD 74.5" STD
Net Door Opening Width 64.5" 64.5" 64.5"
Number of Doors 2 2 2
Exterior Dimensions 99.5" H x 40.5" D x 75.5" W 99.5" H x 80.5" D x 75.5" W 99.5" H x 120.5" D x 75.5" W
Power Input (w/neutral) without compressor *see note 1
Power Input (w/neutral) with compressor *see note 1
Drain ½" FNPT To Air Gap ½" FNPT To Air Gap ½" FNPT To Air Gap
Refrigeration Supplied (Std)**
Remote (Optional)
* Neutral wire circuitry needed to provide 110-120V for miscellaneous control components. A separate line may be run or a
transformer option will be required if 110-120V is not available. Consult factory for 110-120V requirements. Consult factory for 50 Hz requirements. Electrical for remote refrigeration to be supplied by other.
** Refrigeration requirements are based on a minimum of 2 hours to attain retarding temperatures from proofing temperatures.
Consult factory for additional refrigeration requirements if faster times are needed.
3 single end or 4 single side
or 2 double side load
120V/50-60Hz/1 2.5A 120V/50-60Hz/1 2.5A 120V/50-60Hz/1 2.5A
208-240V/60Hz/1 12A N/A N/A
6500 BTU Condenser N/A N/A
One Evaporator Supplied
Minimum 6500 BTU Required
8 single end or 8 single side
or 4 double side load
Two Evaporator Supplied
Minimum 10000 BTU Required
12 single end or 12 single side
or 6 double side load
Two Evaporator Supplied
Minimum 10000 BTU Required
As continued product improvement is a policy of Hobart, specifications are subject to change without notice.
Page 4 of 4 F-40145 – HRW2S Series Two Wide Retarder
F-40145 (05/07) LITHO IN U.S.A. (H-01)