Item # _____________________________________
Quantity ___________________________________
C.S.I. Section 11400
HRW2S SERIES
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
STANDARD FEATURES
■ Modular panel construction
■ Cam lock attachment
■ Stainless steel interior and exterior
■ Self-contained refrigeration system for units with
depth of 37.75"
OPTIONS
❑ Refrigeration
❑ R22
❑ R134A
❑ R404
❑ Stainless steel floor
❑ Pass thru
TWO WIDE RETARDER
MODEL CONFIGURATIONS
❑ 37.75" Interior Depth Two Door – (may be
shipped assembled) Three Single End or Four
Single Side Load Racks or Two Double Racks
❑ 77.75" Interior Depth Two Door – Eight Single
End or Eight Single Side Load Racks or Four
Double Racks
❑ 117.75" Interior Depth Two Door – Twelve
Single End or Twelve Single Side Load Racks or
Six Double Racks
Specifications, Details and Dimensions on Inside and Back.
ACCESSORIES
❑ Side trim
❑ One side
❑ Both sides
❑ Interior light
❑ Rear trim
HRW2S SERIES TWO WIDE RETARDER
F-40145 – HRW2S Series Two Wide Retarder Page 1 of 4

HRW2S SERIES
37.75" Interior Depth
Plan View
37.75" Interior Depth
Side View
77.75" Interior Depth
Plan View
77.75" Interior Depth
Side View
TWO WIDE RETARDER
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
37.75" Interior Depth
Front View
77.75" Interior Depth
Front View
1 Water Supply 85" AFF 2 Electrical Supply 85" AFF 3 Drain 5" AFF Front or Rear
Page 2 of 4 F-40145 – HRW2S Series Two Wide Retarder

HRW2S SERIES
117.75" Interior Depth
Plan View
117.75" Interior Depth
Side View
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
117.75" Interior Depth
Front View
TWO WIDE RETARDER
1 Water Supply 85" AFF 2 Electrical Supply 85" AFF 3 Drain 5" AFF Front or Rear
F-40145 – HRW2S Series Two Wide Retarder Page 3 of 4

Printed On Recycled Paper
HRW2S SERIES
TWO WIDE RETARDER
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
SPECIFICATIONS
GENERAL:
37.75" Interior Depth Two Door – (may be shipped
assembled) Three Single End or Four Single Side Load
Racks or Two Double Racks
77.75" Interior Depth Two Door – Eight Single End or
Eight Single Side Load Racks or Four Double Racks
117.75" Interior Depth Two Door – Twelve Single End
or Twelve Single Side Load Racks or Six Double Racks
CONSTRUCTION: Stainless steel interior and exterior
is standard. The interior perimeter is supplied with
bumpers on all sides to protect the finish.
CAPACITY: Door opening will accommodate 74" high
racks.
INSULATION: The retarder cabinet is rigid and formed
of stainless steel panels with polyurethane foam
insulation and sealed with gaskets to form a strong,
energy efficient, tight and sanitary enclosure.
HARDWARE AND FITTINGS: Heavy-duty, plasticcoated door handles positioned horizontally. Positive
action door closure.
FREIGHT CLASS: 85
For proper installation, floor should be level within
1
⁄8" per foot not to exceed 3⁄4".
DETAILS AND DIMENSIONS
NOTE: The 37.75" interior depth unit has self contained refrigeration system with a single evaporator. The 77.75" and
117.75" interior depth units have 2 evaporators and require remote refrigeration to be charged on-site. The recommended water hardness range is 2-4 grains per gallon. The recommended pH range is 7.0 to 8.0. The acceptable range
for chloride concentration is 0-30 ppm. Consult your local water company and/or water conditioner dealer before using
water on this equipment.
PHYSICAL DATA 37.75" INTERIOR DEPTH 77.75" INTERIOR DEPTH 117.75" INTERIOR DEPTH
Interior Dimensions 74.5" H x 37.75" D x 66" W 74.5" H x 77.75" D x 66" W 74.5" H x 117.75" D x 66" W
Rack Capacity
Net Door Opening Height 74.5" STD 74.5" STD 74.5" STD
Net Door Opening Width 64.5" 64.5" 64.5"
Number of Doors 2 2 2
Exterior Dimensions 99.5" H x 40.5" D x 75.5" W 99.5" H x 80.5" D x 75.5" W 99.5" H x 120.5" D x 75.5" W
Power Input (w/neutral)
without compressor *see
note 1
Power Input (w/neutral)
with compressor *see
note 1
Drain ½" FNPT To Air Gap ½" FNPT To Air Gap ½" FNPT To Air Gap
Refrigeration Supplied
(Std)**
Remote (Optional)
* Neutral wire circuitry needed to provide 110-120V for miscellaneous control components. A separate line may be run or a
transformer option will be required if 110-120V is not available. Consult factory for 110-120V requirements. Consult factory
for 50 Hz requirements. Electrical for remote refrigeration to be supplied by other.
** Refrigeration requirements are based on a minimum of 2 hours to attain retarding temperatures from proofing temperatures.
Consult factory for additional refrigeration requirements if faster times are needed.
3 single end or 4 single side
or 2 double side load
120V/50-60Hz/1 2.5A 120V/50-60Hz/1 2.5A 120V/50-60Hz/1 2.5A
208-240V/60Hz/1 12A N/A N/A
6500 BTU Condenser N/A N/A
One Evaporator Supplied
Minimum 6500 BTU Required
8 single end or 8 single side
or 4 double side load
Two Evaporator Supplied
Minimum 10000 BTU Required
12 single end or 12 single side
or 6 double side load
Two Evaporator Supplied
Minimum 10000 BTU Required
As continued product improvement is a policy of Hobart, specifications are subject to change without notice.
Page 4 of 4 F-40145 – HRW2S Series Two Wide Retarder