Hobart FT1000D User Manual

Item # _____________________________________
Quantity ___________________________________
C.S.I. Section 11400
FT1000D ENERGY RECOVERY
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
STANDARD FEATURES
Pumped rinse system
Water usage 58 gph
Digital controls with machine diagnostics
Low temperature alert
Single point vent connection
36" access doors on prewash, power wash and
power rinse chambers, 25" door access on dual rinse chamber and ASR chamber
Start and stop switches at both ends
Doors open indicator
Drains open indicator
Door interlocks
3 H.P. prewash, and 5 H.P. power wash and
power rinse pump motors, all TEFC
Capless Auto Clean wash arms
Easy to remove scrap trays and baskets
Deep drawn tanks without welds
30" wide conveyor belt
Dual Rinse
Automatic Soil Removal system (ASR)
Auto Clean feature
Auto Delime feature
Energy Recovery
Front and rear panels
Variable speed conveyor
FLIGHT-TYPE DISHWASHER
MODEL
FT1000D Energy Recovery Flight-Type
Dishwasher
OPTIONS AT EXTRA COST
Electric Tank Heat
Steam Tank Heat
Booster Heater Electric Steam
Blower Dryer Electric Steam
6" higher than standard chamber
Multiple conveyor choices
Circuit breakers
Other options available, consult factory
ACCESSORIES
Feet Extended Flanged
Water hammer arrestor/PRV
Specications, Details and Dimensions on Inside and Back.
UL, NSF and LA approvals pending
DIRECTION OF OPERATION
Right to Left
Left to Right
VOLTAGE
208/60/3
240/60/3
480/60/3
Other voltages available – consult factory
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 1 of 20
FT1000D ENERGY RECOVERY FLIGHT-TYPE DISHWASHER
DESIGN: Fully automatic, ight-type dish machine
consisting of a load section with Automatic Soil Removal system, power recirculating prewash, power wash, power rinse, dual rinse and nal rinse section. Included with each machine will be exible plastic strip curtains to control overspray.
CONSTRUCTION: Stainless steel tank and chambers with No. 3 polish on appearance surfaces. Frame, legs and feet to be constructed of stainless steel. Inspection doors to be chamber width.
PUMPS: Recirculating stainless steel pumps with stainless steel impellers. Pump housing has easy to remove coverplate for access to impeller. All pumps are self-draining.
MOTORS: Totally enclosed fan cooled (TEFC) design with overload protection. Pump motors to be 3 H.P. for prewash and 5 H.P. for power wash and power rinse, with conveyor motor to be 1⁄3 H.P. Available in electrical specications of 208/60/3, 240/60/3 and 480/60/3.
CONTROLS: A stainless steel control center with electronic digital controls mounted at eye level. Power “On/Off” and “Start/Stop” switches integrated into keypad. Digital display indicates door(s) open, low temperature alert, tanks/nal rinse temperatures, Auto Clean and Auto Delime instructions and notica­tions, and other pertinent operating data. Additional “Start/Stop” switches are located at each end of machine. Conveyor speed button included on the control center to provide for the adjustable speed conveyor.
FLIGHT-TYPE CONVEYOR: Stainless steel side links, tie rods and conveyor tracks. Injection molded, resilient Duraex ight links.
VENT: Single built-in vent duct with dampers mounted in ventilation stack.
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
AUTOMATIC SOIL REMOVAL SYSTEM (ASR): Two foot section with specialized soil removal wash arms removes food soil from the machine before it reaches the prewash tank. System will pump food soil from the ASR tank into an external collector located under the load section, minimizing the need to pre-scrap dishes and reducing detergent consump­tion. Operator can easily remove and clean external collector without interruption of machine operation.
RECIRCULATING PREWASH SECTION: Prewash compartment is tted with upper and lower wash arms. Prewash ush down for prewash tank bed. Large removable one piece perforated stainless steel screen sloped downward to deep stainless steel scrap basket.
TANK HEAT: Power wash, power rinse and dual rinse tank water temperatures are thermostatically controlled. Low water protection is provided. Specify either electric or steam heat.
FINAL RINSE: Easily removed nal rinse arms.
ENERGY RECOVERY: Energy Recovery system
operates with a cold water line, capturing energy from exhaust air, and using it to elevate the temperature of the water entering the booster heater. The result is savings – both in hot water and in energy.
CONVEYOR DRIVE UNIT: Powered by a 1⁄3 H.P. motor. Trip mechanism provided on unload section. Jam protection is provided by load sensing switch at drive platform. Conveyor speed adjustment of 6.5 feet per minute to 8.5 feet per minute is provided on the digital display keypad.
DRAINS: Manual, hand-operated, located in each tank.
One automatic master drain to be used for Auto Clean and Auto Delime.
BLOWER DRYER (OPTIONAL): Includes (2) 1 H.P. fan motors with sealed ball bearings and overload protection. Blower functions only during conveyor operation.
Page 2 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
FT1000D ENERGY RECOVERY
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
No other control system allows easier monitoring.
The digital controls are placed in a convenient panel that lets operators verify proper operation and temperatures at a glance. Digital display indicates the unit is on, and conrms that the doors are closed. Automatic door interlocks prevent the pump and conveyor from operating if the doors are open. Easy-to-read digital display indicates accurate tem­peratures of the 150°F wash, 160°F power rinse, 160°F dual rinse and 180°F nal rinse — critical for proper HACCP system record-keeping.
Stainless steel pump is built for long life.
The stainless steel pump housing and impeller offer greater durability and long life. The pump motor is totally enclosed and fan cooled (TEFC) to protect it from water spray during dishroom clean-up.
Scrap baskets capture food particles and are easy to clean.
The sloped screens that carry scraps to the scrap baskets are steeper, so less soil gets into the tanks. The basket opening is larger for easy cleaning and basket handles have been designed for easy lift-out access. The load section also features a removable scrap basket which contains soil that is pumped from the ASR section. All scrap baskets and strainers are stainless steel for strength and durability.
The FT1000 Series saves water and energy.
The unit has the lowest water and energy consumption in
the industry, yet provides effective cleaning and sanitizing that meets NSF International requirements.
This is achieved through a carefully balanced ratio of water ow to pressure. Insulated doors and thermal layered curtain at load also reduce heat loss. The unit’s 58 gallons per hour rinse ow rate saves both water and the energy to heat it.
FLIGHT-TYPE DISHWASHER
Wider, variable speed conveyor offers increased throughput.
The conveyor on the FT1000 Series is wider so it can handle more ware. Result: more volume and versatility, quicker work. Its speed is easily adjustable for the type of ware, soiled condition, or workforce requirements. It runs at 6.5 -
8.5 feet per minute.
Energy Recovery system reclaims heat for energy.
The Energy Recovery system captures escaping heat and steam from the exhaust air and uses a heat exchanger to recycle it into energy. This free energy is used to preheat the incom­ing water supply before it enters the booster heater. The cold ground temperature water passes through a heat exchanger positioned directly in line with the machine’s exhaust system to capture the energy from the exhaust air to elevate the temperature of the water to 128° before it enters the booster heater.
Self-draining pumps help keep water clean.
Pumps are self-draining when the machine is shut down, so there is no residual water left in the pumps.
Installation is quick and easy with modular design, minimal wiring connections, and single point vent.
Modular design means the FT1000 installs quickly and reliably. Sections t through 42" doors. The control panel is already in place, premounted to the power wash/power rinse/ nal rinse section.
Wiring connections are minimal, and there is only a single vent connection, saving time and expense. The control box uses a “single plane” circuitry design for easy accessibil­ity during installation and service. The FT1000 is ready to run quickly.
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 3 of 20
FT1000D ENERGY RECOVERY
SEE NO
TE (e)
FLOOR LINE
7 7/8"
OVER FRAME "A"
3 15/16"
6" MINIMUM
ON THE TOP
FLOOR LIN
NOTE: REFER TO LATEST
NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
63 3/8"
ELECTRIC L-R
18 3/4"
37 1/2"
E1
E2
E3
E4
E5
E6
E7
E8
E9
V1
P3P4
2 5/8"
LOAD "B"
3"
P3
25 9/16"
9 15/16"
V1
E5
E4
E9
13' 1-9/16"
35 7/16" 35 7/16" 35 7/16" 25 9/16"
5 3/4"
11 13/16"
E3
E2
E1
E8
E6E7
P2
P1 P4
60"
52"
44 9/16"
EXHAUST HOOD SUPPLIED BY OTHERS
23 3/4"
6"
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
P2 P1
23 3/4"
55 11/16"
UNLOAD "C"
V1
62 3/4"
TE
(f)
EDITION OF NATIONAL ELECTRICAL CODE AND LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED.
E
36 1/2"
LOAD
END
6"
35"
ASR
40 3/8"
44 13/16"
see note (a)
PRE-
WASH
DIRECTION OF OPERATION
22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL 24" RECOMMENDED, WITH DETERGENT DISPENSER
POWER
WASH
POWER
RINSE
AUX
FNL
RNS
RNS
FT1021 (2-1/2'-13'-5-1/2') FT1022 (3-1/2'-13'-5-1/2') FT1023 (4-1/2'-13'-5-1/2') FT1023 (2-1/2'-13'-7-1/2') FT1024 (3-1/2'-13'-7-1/2') FT1025 (4-1/2'-13'-7-1/2') FT1025 (2-1/2'-13'-9') FT1026 (3-1/2'-13'-9') FT1027 (4-1/2'-13'-9') FT1027 (2-1/2'-13'-11') FT1028 (3-1/2'-13'-11') FT1029 (4-1/2'-13'-11') FT1030 (2-1/2'-13'-15') FT1031 (3-1/2'-13'-15') FT1032 (4-1/2'-13'-15') FT1032 (2-1/2'-13'-17') FT1033 (3-1/2'-13'-17') FT1034 (4-1/2'-13'-17')
MODEL NO.
UNLOAD
END
"A" "B" "C"
21' 4" 22' 3-3/4" 3' 7-1/4" 23' 3-19/32" 4' 7-3/32" 23' 3-1/2" 2' 7-1/2" 24' 3-1/4" 3' 7-1/4" 25' 3-3/32" 4' 7-3/32" 24' 11-1/4" 2' 7-1/2" 25' 11" 26' 10-27/32" 4' 7-3/32" 26' 10-7/8" 27' 10-5/8" 28' 10-15/32" 30' 6-3/16" 2' 7-1/2" 31' 5-15/16" 3' 7-1/4" 32' 5-25/32" 4' 7-3/32" 32' 5-3/4" 33' 5-1/2" 34' 5-11/32" 4' 7-3/32"
36 1/4"
2' 7-1/2"
3' 7-1/4"
2' 7-1/2" 3' 7-1/4" 4' 7-3/32"
2' 7-1/2" 3' 7-1/4"
89 3/8"
SEE NO
5' 7" 5' 7" 5' 7" 7' 6-1/2" 7' 6-1/2" 7' 6-1/2" 9' 2-1/4" 9' 2-1/4" 9' 2-1/4" 11' 1-7/8" 11' 1-7/8" 11' 1-7/8" 14' 9-3/16" 14' 9-3/16" 14' 9-3/16" 16' 8-3/4" 16' 8-3/4" 16' 8-3/4"
Page 4 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
FT1000D ENERGY RECOVERY
GENERAL NOTES:
(
THE CONTROL
TION
CLEARANCE FOR DOORWAYS.
ELECTRICAL WARNING:
E
ITH
SERVICE WIRE TEMPERATURE RATING: 90C.
PLUMBING NOTES:
Y,
(b)
(
(d)
(
T
SALES ENGINEERING.
VENTILATION NOTES:
SH,
Do not premix other chemicals and sodium hypochlorite (liquid bleach). Mixing may cause hazardous gas to form.
Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/o other local electrical codes.
Plumbing connections must comply with applicable sanitar codes. vary, some methods are shown on this drawing.
Pressur Important:
abo If ch
,
a 1/2" dia. Use only 6%
chemical Certain
attacked manual.
MODEL: FT1000 ENERGY RECO (ASR ELECTRIC L-R OPERA 00-949505 REV A
ELECTRICAL CONNECTIONS COMMON ON
E1
ND RINSE FEEDERS
E2 ELECTRIC CONNECTION (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS W/O CIRCUIT BREAKERS:
E3
E4
.
E5
E6
E7 1" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
.
1-1/4" CONDUIT, 79-1/8" AFF
PLUMBING CONNECTIONS:
P1
P2 COMMON COLD
P3
P4
D END OPTION IS SPECIFIED).
2" FPT. 7" AFF
VENTILATION REQUIREMENTS:
V1
BLE OF
95-3/8" AFF see note (f).
SERVICE CONNECTION W/O CIRCUIT BREAKERS
480/60/3
ELECTRIC TANK HEAT, WASH
ELECTRIC TANK HEAT, BOOSTER
480/60/3
25.8 35 35
MOTORS AND CONTROLS
480/60/3
MOTORS
SIZE
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (40-45 PSI WHEN EQUIPPED WITH AUTOCLEAN OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESSURE IS UNDER 15 PSI AT THE DISHWASHER, CONTAC
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES (g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS (h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS.
(j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
y, safety and plumbing
Drain and fill line configurations
e gauge not required on pumped rinse machines.
Chemical c ontainers sh ould be plac ed no higher than 10"
ve floor.
emical conta iners are to be placed in cabinet ad jacent to ma chine
hole is req uired in the cabinet to r un chemical supply line.
or 8.4% sod ium hypochlor ite (liquid bleach) as sanitizing
to insure proper operat ion of dishmachine.
materials in cluding silv er plate, aluminum and pewter a re
by sodium hyp ochlorite (li quid bleach). See instruc tional
, ER)
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 5 of 20
VERY
TION
r
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF
ELECTRIC CONNECTION, MOTORS & CONTROLS, 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, POWER RINSE TANK, 20 KW 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, WASH TA NK, 20 KW. 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, D UAL RINSE TANK, 10KW. 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, B OOSTER, 18KW.
WITH CIRCUIT BREAKERS:
E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, RINSE HEAT, BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED) (TB1) 2" CONDUIT, 79-1/8" AFF
E9 ELECTRIC CONNECTION, WASH HEAT & DUAL RINSE HEAT (TB2)
COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER, MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
AUTO CLEAN OPTION) 55°F WATER MINIMUM. 1" FPT, 5-1/2" AFF see notes (b) and (d).
COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED). 2" FPT. 7" AFF
COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA
MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
SERVICE CONNECTION WITH CIRCUIT BREAKERS
(2) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS, CONTROLS, POWER RINSE & BOOSTER HEAT(TB1)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
(5) SERVICE CONNECTIONS AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
RATED
AMPS
156.3
144.9
72.4
WASH, DUAL RINSE HEAT(TB2)
RATED
AMPS
96.1 125 125
91.6 125 125
45.8 60 60
ELECTRIC TANK HEAT, DUAL RINSE
(1) 10KW CONNECTION AS SHOWN BELOW
RATED
AMPS
30.0
28.6
14.3
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
200 200 175 175
90 90
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
35 35 35 35 20 20
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
WATER CONNECTION (FINAL RINSE WITH OR W/O THE
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICE
MAXIMUM
PROTECTIVE
DEVICES
1/3 HP 1/4 HP
3 1/2 HP
5 HP
5 HP 1/6 HP 1/2 HP 1/3 HP 1/3 HP
ELECTRIC L-R
, VENT FAN CONTROL.
ELECTRIC TANK HEAT, POWER RINSE
(1) 18 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3
(1) 22 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
(1) 18 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3
RATED
AMPS
54.0 70 70
51.5 70 70
25.8 35 35
RATED
AMPS
66.0 80 80
63.0 80 80
31.5 40 40
RATED
AMPS
54.0 70 70
51.5 70 70
RATED AMPS
48.2 60 60
41.8 50 50
20.9 25 25
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICE
FT1000D ENERGY RECOVERY
TE
SEE NO
FLOOR LINE
7 7/8"
OVER FRAME "A"
3 15/16"
6" MINIMUM
ON THE TOP
FLOOR LIN
NOTE: REFER TO LATEST
NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
63 3/8"
ELECTRIC R-L
P2 P1
23 3/4"
55 11/16"
V1
UNLOAD "C"
60"
52"
44 9/16"
EXHAUST HOOD SUPPLIED BY OTHERS
23 3/4"
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
P2
P1 P4
18 3/4"
V1
P3 P4
2 5/8"
P3
9 15/16"
V1
E5
E1
E6 E7
E2
E3
E8
5 3/4"
E4
E9
13' 1-9/16"
35 7/16"35 7/16"35 7/16"25 9/16"
25 9/16"
LOAD "B"
3"
11 13/16"
6"
37 1/2"
E1
E2
E3
E4
E5
E6
E7
E8
E9
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED.
E
89 3/8"
TE (e)
35"
36 1/4"
40 3/8"
44 13/16" see note (a)
UNLOAD
END
22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL 24" RECOMMENDED, WITH DETERGENT DISPENSER
FNL RNS
AUX RNS
POWER
RINSE
POWER
WASH
DIRECTION OF OPERATION
MODEL NO.
FT1021 (2-1/2'-13'-5-1/2') FT1022 (3-1/2'-13'-5-1/2') FT1023 (4-1/2'-13'-5-1/2') FT1023 (2-1/2'-13'-7-1/2') FT1024 (3-1/2'-13'-7-1/2') FT1025 (4-1/2'-13'-7-1/2') FT1025 (2-1/2'-13'-9') FT1026 (3-1/2'-13'-9') FT1027 (4-1/2'-13'-9') FT1027 (2-1/2'-13'-11') FT1028 (3-1/2'-13'-11') FT1029 (4-1/2'-13'-11') FT1030 (2-1/2'-13'-15') FT1031 (3-1/2'-13'-15') FT1032 (4-1/2'-13'-15') FT1032 (2-1/2'-13'-17') FT1033 (3-1/2'-13'-17') FT1034 (4-1/2'-13'-17')
PRE-
WASH
21' 4" 22' 3-3/4" 3' 7-1/4" 23' 3-19/32" 4' 7-3/32" 23' 3-1/2" 2' 7-1/2" 24' 3-1/4" 3' 7-1/4" 25' 3-3/32" 4' 7-3/32" 24' 11-1/4" 2' 7-1/2" 25' 11" 26' 10-27/32" 4' 7-3/32" 26' 10-7/8" 27' 10-5/8" 28' 10-15/32" 30' 6-3/16" 2' 7-1/2" 31' 5-15/16" 3' 7-1/4" 32' 5-25/32" 4' 7-3/32" 32' 5-3/4" 33' 5-1/2" 34' 5-11/32" 4' 7-3/32"
ASR
"A" "B" "C"
LOAD
END
2' 7-1/2"
3' 7-1/4"
2' 7-1/2" 3' 7-1/4" 4' 7-3/32"
2' 7-1/2" 3' 7-1/4"
6"
5' 7" 5' 7" 5' 7" 7' 6-1/2" 7' 6-1/2" 7' 6-1/2" 9' 2-1/4" 9' 2-1/4" 9' 2-1/4" 11' 1-7/8" 11' 1-7/8" 11' 1-7/8" 14' 9-3/16" 14' 9-3/16" 14' 9-3/16" 16' 8-3/4" 16' 8-3/4" 16' 8-3/4"
36 1/2"
62 3/4"
SEE NO
(f)
Page 6 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
FT1000D ENERGY RECOVERY
GENERAL NOTES:
(
THE CONTROL
TION
CLEARANCE FOR DOORWAYS.
ELECTRICAL WARNING:
E
ITH
SERVICE WIRE TEMPERATURE RATING: 90C.
PLUMBING NOTES:
Y,
(b)
(
(d)
(
T
SALES ENGINEERING.
VENTILATION NOTES:
SH,
Do not premix other chemicals and sodium hypochlorite (liquid bleach). Mixing may cause hazardous gas to form.
Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/o other local electrical codes.
Plumbing connections must comply with applicable sanitar codes. vary, some methods are shown on this drawing.
Pressur Important:
abo If ch
,
a 1/2" dia. Use only 6%
chemical Certain
attacked manual.
MODEL: FT1000 ENERGY RECO (ASR STEA R-L OPERA 00-949504 REV A
ELECTRICAL CONNECTIONS COMMON ON
E1
ND RINSE FEEDERS
E2 ELECTRIC CONNECTION (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS W/O CIRCUIT BREAKERS:
E3
E4
.
E5
E6
E7 1" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
.
1-1/4" CONDUIT, 79-1/8" AFF
PLUMBING CONNECTIONS:
P1
P2 COMMON COLD
P3
P4
D END OPTION IS SPECIFIED).
2" FPT. 7" AFF
VENTILATION REQUIREMENTS:
V1
BLE OF
95-3/8" AFF see note (f).
SERVICE CONNECTION W/O CIRCUIT BREAKERS
480/60/3
ELECTRIC TANK HEAT, WASH
ELECTRIC TANK HEAT, BOOSTER
480/60/3
25.8 35 35
MOTORS AND CONTROLS
480/60/3
MOTORS
SIZE
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (40-45 PSI WHEN EQUIPPED WITH AUTOCLEAN OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESSURE IS UNDER 15 PSI AT THE DISHWASHER, CONTAC
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES (g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS (h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS.
(j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
y, safety and plumbing
Drain and fill line configurations
e gauge not required on pumped rinse machines.
Chemical c ontainers sh ould be plac ed no higher than 10"
ve floor.
emical conta iners are to be placed in cabinet ad jacent to ma chine
hole is req uired in the cabinet to r un chemical supply line.
or 8.4% sod ium hypochlor ite (liquid bleach) as sanitizing
to insure proper operat ion of dishmachine.
materials in cluding silv er plate, aluminum and pewter a re
by sodium hyp ochlorite (li quid bleach). See instruc tional
, ER)
M
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 7 of 20
VERY
TION
r
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF
ELECTRIC CONNECTION, MOTORS & CONTROLS, 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, POWER RINSE TANK, 20 KW 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, WASH TA NK, 20 KW. 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, D UAL RINSE TANK, 10KW. 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, B OOSTER, 18KW.
WITH CIRCUIT BREAKERS:
E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, RINSE HEAT, BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED) (TB1) 2" CONDUIT, 79-1/8" AFF
E9 ELECTRIC CONNECTION, WASH HEAT & DUAL RINSE HEAT (TB2)
COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER, MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
AUTO CLEAN OPTION) 55°F WATER MINIMUM. 1" FPT, 5-1/2" AFF see notes (b) and (d).
COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED). 2" FPT. 7" AFF
COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA
MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
SERVICE CONNECTION WITH CIRCUIT BREAKERS
(2) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS, CONTROLS, POWER RINSE & BOOSTER HEAT(TB1)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
(5) SERVICE CONNECTIONS AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
RATED
AMPS
156.3
144.9
72.4
WASH, DUAL RINSE HEAT(TB2)
RATED
AMPS
96.1 125 125
91.6 125 125
45.8 60 60
ELECTRIC TANK HEAT, DUAL RINSE
(1) 10KW CONNECTION AS SHOWN BELOW
RATED
AMPS
30.0
28.6
14.3
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
200 200 175 175
90 90
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
35 35 35 35 20 20
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
WATER CONNECTION (FINAL RINSE WITH OR W/O THE
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICE
MAXIMUM
PROTECTIVE
DEVICES
1/3 HP 1/4 HP
3 1/2 HP
5 HP
5 HP 1/6 HP 1/2 HP 1/3 HP 1/3 HP
ELECTRIC R-L
, VENT FAN CONTROL.
ELECTRIC TANK HEAT, POWER RINSE
(1) 18 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3
(1) 22 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
(1) 18 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3
RATED
AMPS
54.0 70 70
51.5 70 70
25.8 35 35
RATED
AMPS
66.0 80 80
63.0 80 80
31.5 40 40
RATED
AMPS
54.0 70 70
51.5 70 70
RATED AMPS
48.2 60 60
41.8 50 50
20.9 25 25
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICE
FT1000D ENERGY RECOVERY
SEE NO
)
FLOOR LINE
3 15/16"
7 7/8"
OVER FRAME "A"
6" MINIMUM
ON THE TOP
NOTE: REFER TO LATEST
FLOOR LIN
Do not premix other chemicals and sodium hypochlorite (liquid bleach). Mixing may cause hazardous gas to form.
Pressure gau ge I
a I
,
a Use
chemical to C
a ma
63 3/8"
37 1/2"
E1
E2
E3
STEAM L-R
18 3/4"
V1
P4P3
2 5/8"
P3
15 11/16"
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
P1
55 3/16"
P2
51 15/16"
P4
44 9/16"
33"
P10
14 11/16"
P6
P7
5 15/16"
E3
68 13/16"
P8
9 15/16"
E2
E1
33 3/8"
2 15/16"
11 13/16"
P8
P6
23 1/8"
V1
P9
28 7/16"
38 1/4"
P5
P8
P8
6 3/4"
P10
11 9/16"
21 3/4"
23"
P7
P1
P9
23 3/4"
P2
P5
28 15/16"
55 11/16"
LOAD "B"
3"
LOAD
END
62 3/4"
TE
(h)
36 1/2"
6"
Page 8 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED.
35"
E
25 9/16"
ASR
13' 1-9/16"
35 7/16" 35 7/16" 35 7/16" 25 9/16"
5 3/4"
POWER
WASH
22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL 24" RECOMMENDED, WITH DETERGENT DISPENSER
40 3/8"
44 13/16"
see note (a)
PRE­WASH
DIRECTION OF OPERATION
POWER
RINSE
AUX
RNS
FNL RNS
UNLOAD "C"
EXHAUST HOOD SUPPLIED BY OTHERS
23 3/4"
6"
UNLOAD
END
mportant: Chemical containers should be placed no higher than 10"
bove floor.
f chemical c ontainers ar e to be place d in cabinet adjacent to machine
1/2" dia. h ole is requi red in the ca binet to run chemical supply line.
ertain mater ials includi ng silver pl ate, aluminum and p ewter are ttacked by sod ium hypochlo rite (liquid bleach). See instructiona l
nual.
not required on pumped ri nse machines .
only 6% or 8.4% sodium hypochlorite (liquid blea ch) as sanitizing
insure prop er operation of dishmachi ne.
SEE NOTE (g
36 1/4"
V1
89 3/8"
FT1000D ENERGY RECOVERY
GENERAL NOTES:
(
THE CONTROL
TION
CLEARANCE FOR DOORWAYS.
ELECTRICAL WARNING:
E
ITH
SERVICE WIRE TEMPERATURE RATING: 90C.
PLUMBING NOTES:
Y,
(b)
(
(d)
( SALES ENGINEERING.
VENTILATION NOTES:
SH,
NO
MODEL: FT1000 ENERGY RECO (ASR STEA L-R OPERA 00-949505 REV A
ELECTRICAL CONNECTIONS COMMON ON
E1
ND RINSE FEEDERS
E2 ELECTRIC CONNECTION (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS WITH &
E3
,
1" CONDUIT. 79-1/8" AFF
PLUMBING CONNECTIONS:
D END OPTION IS SPECIFIED).
VENTILATION REQUIREMENTS:
BLE OF
95-3/8" AFF see note (f).
vary, some methods are shown on this drawing.
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (40-45 PSI WHEN EQUIPPED WITH AUTOCLEAN OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESURE IS UNDER 15 PSI AT THE DISHWASHER, CONTACT
STEAM L-R
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF
W/O CIRCUIT BREAKERS:
ELECTRIC CONNECTION, MOTORS & CONTROLS
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER, MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION (FINAL RINSE WITH OR W/O THE AUTO CLEAN OPTION) 55°F WATER MINIMUM. 1" FPT, 5-1/2" AFF see notes (b) and (d).
P3 COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED). 2" FPT. 7" AFF
P4 COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA 2" FPT. 7" AFF
P5 COMMON STEAM CONNECTION (TANK HEAT). 1-1/2" FPT, 4-3/8" AFF (50 PSI MAX, 15-25 FLOWING PRESSURE) see note (e).
P6 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 16-15/16" AFF
P7 HOT RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 15-9/16" AFF
P8 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT), BUCKET TYPE TRAPS FURNISHED, 3 CONNECTIONS. 3/4" FPT, 11" AFF
P9 CONDENSAT E RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER OPTION IS SPECIFIED), BUCKET TYPE TRAP FURNISHED. 3/4" FPT, 4-3/4" AFF
V1 MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
, VENT FAN CONTROL.
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES (g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS (h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS. (j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
MODEL NO.
FT1021 (2-1/2'-13'-5-1/2') FT1022 (3-1/2'-13'-5-1/2') FT1023 (4-1/2'-13'-5-1/2') FT1023 (2-1/2'-13'-7-1/2') FT1024 (3-1/2'-13'-7-1/2') FT1025 (4-1/2'-13'-7-1/2') FT1025 (2-1/2'-13'-9') FT1026 (3-1/2'-13'-9') FT1027 (4-1/2'-13'-9') FT1027 (2-1/2'-13'-11') 26' 10-7/8" FT1028 (3-1/2'-13'-11') 27' 10-5/8" FT1029 (4-1/2'-13'-11') 28' 10-15/32" FT1030 (2-1/2'-13'-15') FT1031 (3-1/2'-13'-15') FT1032 (4-1/2'-13'-15') FT1032 (2-1/2'-13'-17') 32' 5-3/4" FT1033 (3-1/2'-13'-17') 33' 5-1/2" FT1034 (4-1/2'-13'-17')
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
, ER)
M
VERY
TION
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 9 of 20
"A" "B" "C"
2' 7-1/2"
3' 7-1/4" 9' 2-1/4"
2' 7-1/2" 11' 1-7/8" 3' 7-1/4" 11' 1-7/8" 4' 7-3/32" 11' 1-7/8"
2' 7-1/2" 16' 8-3/4" 3' 7-1/4" 16' 8-3/4"
5' 7" 5' 7" 5' 7"
7' 6-1/2"
21' 4" 22' 3-3/4" 3' 7-1/4" 23' 3-19/32" 4' 7-3/32" 23' 3-1/2" 2' 7-1/2" 7' 6-1/2" 24' 3-1/4" 3' 7-1/4" 25' 3-3/32" 4' 7-3/32" 7' 6-1/2" 24' 11-1/4" 2' 7-1/2" 9' 2-1/4" 25' 11" 26' 10-27/32" 4' 7-3/32" 9' 2-1/4"
30' 6-3/16" 2' 7-1/2" 14' 9-3/16" 31' 5-15/16" 3' 7-1/4" 14' 9-3/16" 32' 5-25/32" 4' 7-3/32" 14' 9-3/16"
34' 5-11/32" 4' 7-3/32" 16' 8-3/4"
Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.
Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations
SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS
(1) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE
(1) 10 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
RATED
AMPS
48.2
41.8
20.9
MOTORS
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
60 60 50 50 25 25
SIZE 1/3 HP 1/4 HP
3 1/2 HP
5 HP
5 HP 1/6 HP 1/2 HP 1/3 HP 1/3 HP
MAXIMUM
PROTECTIVE
DEVICES
FT1000D ENERGY RECOVERY
Do not premix other chemicals and sodium hypochlorite (liquid bleach). Mixing may cause hazardous gas to form.
Pressure gau ge I
a I
,
a Use
chemical to C
a ma
TE
SEE NO
FLOOR LINE
7 7/8"
3 15/16"
OVER FRAME "A"
6" MINIMUM
ON THE TOP
FLOOR LIN
NOTE: REFER TO LATEST
see note (a)
63 3/8"
60"
STEAM R-L
P2
P9
P1
P5
23 3/4"
28 15/16"
55 11/16"
23 1/16"
11 5/8"
P7
6 3/4"
P10
P9
P5
28 7/16"
38 1/4"
52"
44 9/16"
P6
23 1/8"
P2 P1 P4
32 15/16" 14 5/8"
5 7/8"
V1
11 13/16"
P6
P7
53 3/8"
22 5/8"
9 15/16"
P10
E1
88 3/4"
P8
E2
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
P8
E3
P8
15 11/16"
P8
18 3/4"
V1
P3 P4
2 5/8"
P3
37 1/2"
E1
E2
E3
V1
89 3/8"
TE (g)
36 1/4"
Page 10 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED.
35"
E
40 3/8"
44 13/16"
UNLOAD "C"
EXHAUST HOOD SUPPLIED BY
OTHERS
23 3/4"
UNLOAD
END
22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL 24" RECOMMENDED, WITH DETERGENT DISPENSER
13' 1-9/16"
35 7/16"35 7/16"35 7/16"25 9/16"
5 3/4"
6"
FNL RNS
AUX RNS
POWER
RINSE
POWER
WASH
DIRECTION OF OPERATION
mportant: Chemical containers should be placed no higher than 10"
bove floor.
f chemical c ontainers ar e to be place d in cabinet adjacent to machine
1/2" dia. h ole is requi red in the ca binet to run chemical supply line.
only 6% or 8.4% sodium hypochlorite (liquid blea ch) as sanitizing
ertain mater ials includi ng silver pl ate, aluminum and p ewter are ttacked by sod ium hypochlo rite (liquid bleach). See instructiona l
nual.
PRE-
WASH
not required on pumped ri nse machines .
insure prop er operation of dishmachi ne.
25 9/16"
ASR
LOAD "B"
3"
LOAD
END
62 3/4"
SEE NO
(h)
36 1/2"
6"
FT1000D ENERGY RECOVERY
GENERAL NOTES:
(
THE CONTROL
TION
CLEARANCE FOR DOORWAYS.
ELECTRICAL WARNING:
E
ITH
SERVICE WIRE TEMPERATURE RATING: 90C.
PLUMBING NOTES:
Y,
(b)
(
(d)
( SALES ENGINEERING.
VENTILATION NOTES:
SH,
NO
MODEL: FT1000 ENERGY RECO (ASR STEA R-L OPERA 00-949504 REV A
ELECTRICAL CONNECTIONS COMMON ON
E1
ND RINSE FEEDERS
E2 ELECTRIC CONNECTION (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS WITH &
E3
,
1" CONDUIT. 79-1/8" AFF
PLUMBING CONNECTIONS:
D END OPTION IS SPECIFIED).
VENTILATION REQUIREMENTS:
BLE OF
95-3/8" AFF see note (f).
vary, some methods are shown on this drawing.
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (40-45 PSI WHEN EQUIPPED WITH AUTOCLEAN OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESURE IS UNDER 15 PSI AT THE DISHWASHER, CONTACT
STEAM R-L
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF
W/O CIRCUIT BREAKERS:
ELECTRIC CONNECTION, MOTORS & CONTROLS
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER, MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION (FINAL RINSE WITH OR W/O THE AUTO CLEAN OPTION) 55°F WATER MINIMUM. 1" FPT, 5-1/2" AFF see notes (b) and (d).
P3 COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED). 2" FPT. 7" AFF
P4 COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA 2" FPT. 7" AFF
P5 COMMON STEAM CONNECTION (TANK HEAT). 1-1/2" FPT, 4-3/8" AFF (50 PSI MAX, 15-25 FLOWING PRESSURE) see note (e).
P6 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 16-15/16" AFF
P7 HOT RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 15-9/16" AFF
P8 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT), BUCKET TYPE TRAPS FURNISHED, 3 CONNECTIONS. 3/4" FPT, 11" AFF
P9 CONDENSAT E RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER OPTION IS SPECIFIED), BUCKET TYPE TRAP FURNISHED. 3/4" FPT, 4-3/4" AFF
V1 MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
, VENT FAN CONTROL.
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES (g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS (h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS. (j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
MODEL NO.
FT1021 (2-1/2'-13'-5-1/2') FT1022 (3-1/2'-13'-5-1/2') FT1023 (4-1/2'-13'-5-1/2') FT1023 (2-1/2'-13'-7-1/2') FT1024 (3-1/2'-13'-7-1/2') FT1025 (4-1/2'-13'-7-1/2') FT1025 (2-1/2'-13'-9') FT1026 (3-1/2'-13'-9') FT1027 (4-1/2'-13'-9') FT1027 (2-1/2'-13'-11') 26' 10-7/8" FT1028 (3-1/2'-13'-11') 27' 10-5/8" FT1029 (4-1/2'-13'-11') 28' 10-15/32" FT1030 (2-1/2'-13'-15') FT1031 (3-1/2'-13'-15') FT1032 (4-1/2'-13'-15') FT1032 (2-1/2'-13'-17') 32' 5-3/4" FT1033 (3-1/2'-13'-17') 33' 5-1/2" FT1034 (4-1/2'-13'-17')
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
, ER)
M
VERY
TION
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 11 of 20
"A" "B" "C"
2' 7-1/2"
3' 7-1/4" 9' 2-1/4"
2' 7-1/2" 11' 1-7/8" 3' 7-1/4" 11' 1-7/8" 4' 7-3/32" 11' 1-7/8"
2' 7-1/2" 16' 8-3/4" 3' 7-1/4" 16' 8-3/4"
5' 7" 5' 7" 5' 7"
7' 6-1/2"
21' 4" 22' 3-3/4" 3' 7-1/4" 23' 3-19/32" 4' 7-3/32" 23' 3-1/2" 2' 7-1/2" 7' 6-1/2" 24' 3-1/4" 3' 7-1/4" 25' 3-3/32" 4' 7-3/32" 7' 6-1/2" 24' 11-1/4" 2' 7-1/2" 9' 2-1/4" 25' 11" 26' 10-27/32" 4' 7-3/32" 9' 2-1/4"
30' 6-3/16" 2' 7-1/2" 14' 9-3/16" 31' 5-15/16" 3' 7-1/4" 14' 9-3/16" 32' 5-25/32" 4' 7-3/32" 14' 9-3/16"
34' 5-11/32" 4' 7-3/32" 16' 8-3/4"
Electrical and grounding connections must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.
Plumbing connections must comply with applicable sanitary, safety and plumbing codes. Drain and fill line configurations
SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS
(1) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE
(1) 10 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
RATED
AMPS
48.2
41.8
20.9
MOTORS
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
60 60 50 50 25 25
SIZE 1/3 HP 1/4 HP
3 1/2 HP
5 HP
5 HP 1/6 HP 1/2 HP 1/3 HP 1/3 HP
MAXIMUM
PROTECTIVE
DEVICES
FT1000D ENERGY RECOVERY
SEE NO
)
FLOOR LINE
7 3/16"
3 15/16"
OVER FRAME "A"
63 3/8"
6" MINIMUM
ON THE TOP
FLOOR LIN
NOTE: REFER TO LATEST
NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
W/BLOWER DRYER, ELECTRIC L-R
18 3/4"
37 1/2"
E1
E2
E3
E4
E5
E6
E7
E8
E9
V1
P3P4
2 5/8"
P3
9 15/16"
E5
E3
E4
E2
E1
E8
E9
E6E7
25 9/16"
3"
35 7/16" 35 7/16" 35 7/16" 25 9/16"
5 3/4"
11 13/16"
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
P2
P1 P4
V1
52"
44 9/16"
EXHAUST HOOD SUPPLIED BY OTHERS
43 5/16"
23 3/4"
6"
60"
P2 P1
23 3/4"
55 11/16"
UNLOAD "C"LOAD "B"
V1
62 3/4"
TE
(f)
36 1/2"
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED.
E
BLOWER/
DRYER
LOAD
END
6"
35"
ASR
40 3/8"
44 13/16"
see note (a)
PRE-
WASH
DIRECTION OF OPERATION
22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL 24" RECOMMENDED, WITH DETERGENT DISPENSER
POWER
WASH
POWER
RINSE
AUX
FNL
RNS
RNS
MODEL NO.
FT1021 (2-1/2'-13'-5-1/2') FT1022 (3-1/2'-13'-5-1/2') FT1023 (4-1/2'-13'-5-1/2') FT1023 (2-1/2'-13'-7-1/2') FT1024 (3-1/2'-13'-7-1/2') FT1025 (4-1/2'-13'-7-1/2') FT1025 (2-1/2'-13'-9') FT1026 (3-1/2'-13'-9') FT1027 (4-1/2'-13'-9') FT1027 (2-1/2'-13'-11') 26' 10-7/8" FT1028 (3-1/2'-13'-11') 27' 10-5/8" FT1029 (4-1/2'-13'-11') 28' 10-15/32" FT1030 (2-1/2'-13'-15') FT1031 (3-1/2'-13'-15') FT1032 (4-1/2'-13'-15') FT1032 (2-1/2'-13'-17') 32' 5-3/4" FT1033 (3-1/2'-13'-17') 33' 5-1/2" FT1034 (4-1/2'-13'-17')
UNLOAD
END
36 1/4"
"A" "B" "C"
21' 4" 22' 3-3/4" 3' 7-1/4" 23' 3-19/32" 4' 7-3/32" 23' 3-1/2" 2' 7-1/2" 7' 6-1/2" 24' 3-1/4" 3' 7-1/4" 25' 3-3/32" 4' 7-3/32" 7' 6-1/2" 24' 11-1/4" 2' 7-1/2" 9' 2-1/4" 25' 11" 26' 10-27/32" 4' 7-3/32" 9' 2-1/4"
30' 6-3/16" 2' 7-1/2" 14' 9-3/16" 31' 5-15/16" 3' 7-1/4" 14' 9-3/16" 32' 5-25/32" 4' 7-3/32" 14' 9-3/16"
34' 5-11/32" 4' 7-3/32" 16' 8-3/4"
2' 7-1/2"
3' 7-1/4" 9' 2-1/4"
2' 7-1/2" 11' 1-7/8" 3' 7-1/4" 11' 1-7/8" 4' 7-3/32" 11' 1-7/8"
2' 7-1/2" 16' 8-3/4" 3' 7-1/4" 16' 8-3/4"
89 3/8"
SEE NOTE (e
5' 7" 5' 7" 5' 7"
7' 6-1/2"
Page 12 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
FT1000D ENERGY RECOVERY
GENERAL NOTES:
(
THE CONTROL
TION
CLEARANCE FOR DOORWAYS.
ELECTRICAL WARNING:
E
ITH
SERVICE WIRE TEMPERATURE RATING: 90C.
PLUMBING NOTES:
Y,
(b)
(
(d)
(
T
SALES ENGINEERING.
VENTILATION NOTES:
SH,
Do not premix other chemicals and sodium hypochlorite (liquid bleach). Mixing may cause hazardous gas to form.
Electrical and grounding connection must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.
Plumbing connections must comply with applicable sanitar codes. vary, some methods are shown on this drawing.
Pressure gauge not required on pumped rinse machines. Important:
above floor If chemical containers are to be placed in cabinet adjacent to machine,
a 1/2" dia. hole is required in the cabinet to run chemical supply line Use only 6% or 8.4% sodium hypochlorite (liquid bleach) as sanitizing
chemical to insure proper operation of dishmachine Certain materials including silver plat
attacked manual.
MODEL: FT1000 ENERGY RECO (ASR ELECTRIC L-R OPERA 00-949507 REV A
ELECTRICAL CONNECTIONS COMMON ON
E1
ND RINSE FEEDERS
E2 ELECTRIC CONNECTIO (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS W/O CIRCUIT BREAKERS:
E3
E4
.
E5
E6
E7 1" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
.
1-1/4" CONDUIT, 79-1/8" AFF
PLUMBING CONNECTIONS:
P1
P2 COMMON COLD
P3
P4
D END OPTION IS SPECIFIED).
2" FPT. 7" AFF
VENTILATION REQUIREMENTS:
V1
BLE OF
95-3/8" AFF see note (f).
SERVICE CONNECTION W/O CIRCUIT BREAKERS
MOTORS
SIZE
480/60/3
ELECTRIC TANK HEAT, WASH
ELECTRIC TANK HEAT, BOOSTER
07 07
480/60/3
25.83535
MOTORS AND CONTROLS
480/60/3
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (45-50 PSI WHEN EQUIPPED WITH AUTOCLEAN OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESSURE IS UNDER 15 PSI AT THE DISHWASHER, CONTAC
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES (g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS (h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS.
(j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
y, safety and plumbing
Drain and fill line configurations
Chemical containers should be placed no higher than 10"
.
by sodium hypochlorite (liquid bleach). See instructional
, ER, B/D)
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 13 of 20
TION
e, aluminum and pewter are
VERY
s
.
W/BLOWER DRYER, ELECTRIC L-R
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF
ELECTRIC CONNECTION, MOTORS & CONTROLS, 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, POWER RINSE TANK, 20 KW 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, WASH TA NK, 20 KW. 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, D UAL RINSE TANK, 10KW. 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, B OOSTER, 18KW.
WITH CIRCUIT BREAKERS:
E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, RINSE HEAT, BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED) (TB1) 2" CONDUIT, 79-1/8" AFF
E9 ELECTRIC CONNECTION, WASH HEAT & DUAL RINSE HEAT (TB2)
COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER, MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
AUTO CLEAN OPTION) 55°F WATER MINIMUM. 1" FPT, 1-1/2" AFF see notes (b) and (d).
COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED). 2" FPT. 7" AFF
COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA
MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
SERVICE CONNECTION WITH CIRCUIT BREAKERS
(2) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS, CONTROLS, POWER RINSE & BOOSTER HEAT(TB1)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
(5) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE, B/D HEAT & BLOWERS
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
.
SPECS.
208/60/3 240/60/3 480/60/3
RATED
AMPS
156.3
144.9
72.4
WASH, DUAL RINSE HEAT(TB2)
RATED
AMPS
128.2 150 150
121.5 150 150
60.7 75 75
RATED
AMPS
62.1
58.5
29.3
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
200
175 175
90 90
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
80 80 70 70 35 35
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
N, VENT FAN CONTROL.
WATER CONNECTION (FINAL RINSE WITH OR W/O THE
ELECTRIC TANK HEAT, POWER RINSE
(1) 18KW CONNECTION AS SHOWN BELOW
MAXIMUM
PROTECTIVE
DEVICES
200
MAXIMUM
PROTECTIVE
DEVICE
MAXIMUM
PROTECTIVE
DEVICES
1/3 HP 1/4 HP
3 1/2 HP
5 HP
5 HP 1/6 HP 1/2 HP 1/3 HP 1/3 HP
ELEC.
SPECS.
208/60/3 240/60/3
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
ELEC.
SPECS.
208/60/3 240/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3
RATED AMPS
(1) 22 KW CONNECTION AS SHOWN BELOW
RATED AMPS
(1) 18 KW CONNECTION AS SHOWN BELOW
RATED
54.0 70 70
51.5 70 70
25.8 35 35
66.0 80 80
63.0 80 80
31.5 40 40
RATED
AMPS
54.07
51.57
AMPS
48.2 60 60
41.8 50 50
20.9 25 25
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
0 0
MAXIMUM
PROTECTIVE
DEVICE
FT1000D ENERGY RECOVERY
NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
TE
SEE NO
FLOOR LINE
7 7/8"
OVER FRAME "A"
3 15/16"
6" MINIMUM
ON THE TOP
FLOOR LIN
NOTE: REFER TO LATEST
63 3/8"
W/BLOWER DRYER, ELECTRIC R-L
23 3/4"
6"
P2
P1 P4
V1
9 15/16"
11 13/16"
E1
E6 E7
5 3/4"
E5
E3
E4
E2
E8
E9
55 11/16"
P2 P1
23 3/4"
60"
52"
44 9/16"
UNLOAD "C"
EXHAUST HOOD SUPPLIED BY OTHERS
43 5/16"
V1
13' 1-9/16"
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
18 3/4"
V1
P3 P4
2 5/8"
P3
35 7/16"35 7/16"35 7/16"25 9/16"
25 9/16"
LOAD "B"
3"
37 1/2"
E1
E2
E3
E4
E5
E6
E7
E8
E9
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED.
E
89 3/8"
TE (e)
35"
36 1/4"
40 3/8"
44 13/16" see note (a)
BLOWER/
UNLOAD
END
22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL 24" RECOMMENDED, WITH DETERGENT DISPENSER
DRYER
FNL RNS
AUX RNS
POWER
RINSE
POWER
WASH
DIRECTION OF OPERATION
MODEL NO.
FT1021 (2-1/2'-13'-5-1/2') FT1022 (3-1/2'-13'-5-1/2') FT1023 (4-1/2'-13'-5-1/2') FT1023 (2-1/2'-13'-7-1/2') FT1024 (3-1/2'-13'-7-1/2') FT1025 (4-1/2'-13'-7-1/2') FT1025 (2-1/2'-13'-9') FT1026 (3-1/2'-13'-9') FT1027 (4-1/2'-13'-9') FT1027 (2-1/2'-13'-11') 26' 10-7/8" FT1028 (3-1/2'-13'-11') 27' 10-5/8" FT1029 (4-1/2'-13'-11') 28' 10-15/32" FT1030 (2-1/2'-13'-15') FT1031 (3-1/2'-13'-15') FT1032 (4-1/2'-13'-15') FT1032 (2-1/2'-13'-17') 32' 5-3/4" FT1033 (3-1/2'-13'-17') 33' 5-1/2" FT1034 (4-1/2'-13'-17')
PRE-
WASH
ASR
"A" "B" "C"
21' 4" 22' 3-3/4" 3' 7-1/4" 23' 3-19/32" 4' 7-3/32" 23' 3-1/2" 2' 7-1/2" 7' 6-1/2" 24' 3-1/4" 3' 7-1/4" 25' 3-3/32" 4' 7-3/32" 7' 6-1/2" 24' 11-1/4" 2' 7-1/2" 9' 2-1/4" 25' 11" 26' 10-27/32" 4' 7-3/32" 9' 2-1/4"
30' 6-3/16" 2' 7-1/2" 14' 9-3/16" 31' 5-15/16" 3' 7-1/4" 14' 9-3/16" 32' 5-25/32" 4' 7-3/32" 14' 9-3/16"
34' 5-11/32" 4' 7-3/32" 16' 8-3/4"
LOAD
END
36 1/2"
6"
2' 7-1/2"
3' 7-1/4" 9' 2-1/4"
2' 7-1/2" 11' 1-7/8" 3' 7-1/4" 11' 1-7/8" 4' 7-3/32" 11' 1-7/8"
2' 7-1/2" 16' 8-3/4" 3' 7-1/4" 16' 8-3/4"
5' 7" 5' 7" 5' 7"
7' 6-1/2"
62 3/4"
SEE NO
(f)
Page 14 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
FT1000D ENERGY RECOVERY
GENERAL NOTES:
(
THE CONTROL
TION
CLEARANCE FOR DOORWAYS.
ELECTRICAL WARNING:
E
ITH
SERVICE WIRE TEMPERATURE RATING: 90C.
PLUMBING NOTES:
Y,
(b)
(
(d)
(
T
SALES ENGINEERING.
VENTILATION NOTES:
SH,
Do not premix other chemicals and sodium hypochlorite (liquid bleach). Mixing may cause hazardous gas to form.
Electrical and grounding connection must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.
Plumbing connections must comply with applicable sanitar codes. vary, some methods are shown on this drawing.
Pressure gauge not required on pumped rinse machines. Important:
above floor If chemical containers are to be placed in cabinet adjacent to machine,
a 1/2" dia. hole is required in the cabinet to run chemical supply line Use only 6% or 8.4% sodium hypochlorite (liquid bleach) as sanitizing
chemical to insure proper operation of dishmachine Certain materials including silver plat
attacked manual.
ELECTRICAL CONNECTIONS COMMON ON
E1
ND RINSE FEEDERS
E2 ELECTRIC CONNECTIO (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS W/O CIRCUIT BREAKERS:
E3
E4
.
E5
E6
E7 1" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
.
1-1/4" CONDUIT, 79-1/8" AFF
PLUMBING CONNECTIONS:
P1
P2 COMMON COLD
P3
P4
D END OPTION IS SPECIFIED).
2" FPT. 7" AFF
VENTILATION REQUIREMENTS:
V1
BLE OF
95-3/8" AFF see note (f).
SERVICE CONNECTION W/O CIRCUIT BREAKERS
MOTORS
SIZE
480/60/3
ELECTRIC TANK HEAT, WASH
ELECTRIC TANK HEAT, BOOSTER
07 07
480/60/3
25.83535
MOTORS AND CONTROLS
480/60/3
MODEL: FT1000 ENERGY RECOVERY (ASR ELECTRIC R-L OPERA 00-949506 REV A
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (45-50 PSI WHEN EQUIPPED WITH AUTOCLEAN OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESSURE IS UNDER 15 PSI AT THE DISHWASHER, CONTAC
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES (g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS (h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS.
(j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
y, safety and plumbing
Drain and fill line configurations
Chemical containers should be placed no higher than 10"
.
by sodium hypochlorite (liquid bleach). See instructional
, ER, B/D)
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 15 of 20
TION
e, aluminum and pewter are
s
.
W/BLOWER DRYER, ELECTRIC R-L
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF
ELECTRIC CONNECTION, MOTORS & CONTROLS, 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, POWER RINSE TANK, 20 KW 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, WASH TA NK, 20 KW. 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, D UAL RINSE TANK, 10KW. 1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, B OOSTER, 18KW.
WITH CIRCUIT BREAKERS:
E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, RINSE HEAT, BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED) (TB1) 2" CONDUIT, 79-1/8" AFF
E9 ELECTRIC CONNECTION, WASH HEAT & DUAL RINSE HEAT (TB2)
COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER, MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
AUTO CLEAN OPTION) 55°F WATER MINIMUM. 1" FPT, 1-1/2" AFF see notes (b) and (d).
COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED). 2" FPT. 7" AFF
COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA
MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
SERVICE CONNECTION WITH CIRCUIT BREAKERS
(2) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS, CONTROLS, POWER RINSE & BOOSTER HEAT(TB1)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
(5) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE, B/D HEAT & BLOWERS
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
.
SPECS.
208/60/3 240/60/3 480/60/3
RATED
AMPS
156.3
144.9
72.4
WASH, DUAL RINSE HEAT(TB2)
RATED
AMPS
128.2 150 150
121.5 150 150
60.7 75 75
RATED
AMPS
62.1
58.5
29.3
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
200
175 175
90 90
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
80 80 70 70 35 35
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
N, VENT FAN CONTROL.
WATER CONNECTION (FINAL RINSE WITH OR W/O THE
ELECTRIC TANK HEAT, POWER RINSE
(1) 18KW CONNECTION AS SHOWN BELOW
MAXIMUM
PROTECTIVE
DEVICES
200
MAXIMUM
PROTECTIVE
DEVICE
MAXIMUM
PROTECTIVE
DEVICES
1/3 HP 1/4 HP
3 1/2 HP
5 HP
5 HP 1/6 HP 1/2 HP 1/3 HP 1/3 HP
ELEC.
SPECS.
208/60/3 240/60/3
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
ELEC.
SPECS.
208/60/3 240/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3
RATED AMPS
(1) 22 KW CONNECTION AS SHOWN BELOW
RATED AMPS
(1) 18 KW CONNECTION AS SHOWN BELOW
RATED
54.0 70 70
51.5 70 70
25.8 35 35
66.0 80 80
63.0 80 80
31.5 40 40
RATED
AMPS
54.07
51.57
AMPS
48.2 60 60
41.8 50 50
20.9 25 25
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
0 0
MAXIMUM
PROTECTIVE
DEVICE
FT1000D ENERGY RECOVERY
SEE NO
)
FLOOR LINE
3 15/16"
OVER FRAME "A"
7 7/8"
6" MINIMUM
ON THE TOP
FLOOR LIN
NOTE: REFER TO LATEST
Pressure gauge not required on pumped rinse machines. Important:
above floor If chemical containers are to be placed in cabinet adjacent to machine,
a 1/2" dia. hole is required in the cabinet to run chemical supply line Use only 6% or 8.4% sodium hypochlorite (liquid bleach) as sanitizing
chemical to insure proper operation of dishmachine Certain materials including silver plat
attacked manual.
Do not premix other chemicals and sodium hypochlorite (liquid bleach). Mixing may cause hazardous gas to form.
63 3/8"
P1
P5
W/BLOWER DRYER, STEAM L-R
P8
15 11/16"
P8
18 3/4"
37 1/2"
E1
E2
E3
V1 P4P3
2 5/8"
P3
E3
P6
P7
68 13/16"
P8
9 15/16"
E2
E1
14 11/16"
5 15/16"
33 3/8"
2 15/16"
11 13/16"
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
55 3/16"
P2
51 15/16"
P4
44 9/16"
33"
P10
P10
6 3/4"
P8
23 1/8"
P6
V1
P9
28 7/16"
38 1/4"
11 9/16"
21 3/4"
23"
P7
P1
P9
23 3/4"
P2
P5
28 15/16"
55 11/16"
END
25 9/16"
3"
ASR
35"
LOAD "B"
LOAD
62 3/4"
TE
(f)
36 1/2"
6"
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED.
Page 16 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
E
13' 1-9/16"
35 7/16" 35 7/16" 35 7/16" 25 9/16"
5 3/4"
40 3/8"
44 13/16"
see note (a)
PRE-
WASH
DIRECTION OF OPERATION
22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL 24" RECOMMENDED, WITH DETERGENT DISPENSER
POWER
WASH
POWER
RINSE
UNLOAD "C"
EXHAUST HOOD SUPPLIED BY OTHERS
43 5/16"
23 3/4"
6"
V1
BLOWER/
DRYER
AUX
FNL
RNS
RNS
UNLOAD
END
36 1/4"
Chemical containers should be placed no higher than 10"
.
by sodium hypochlorite (liquid bleach). See instructional
e, aluminum and pewter are
89 3/8"
SEE NOTE (e
.
.
FT1000D ENERGY RECOVERY
GENERAL NOTES:
(
THE CONTROL
TION
CLEARANCE FOR DOORWAYS.
ELECTRICAL WARNING:
E
ITH
SERVICE WIRE TEMPERATURE RATING: 90C.
PLUMBING NOTES:
Y,
(b)
(
(d)
(
T
SALES ENGINEERING.
VENTILATION NOTES:
SH,
(j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
NO
MODEL: FT1000 ENERGY RECO (ASR STEA L-R OPERA 00-949507 REV A
ELECTRICAL CONNECTIONS COMMON ON
E1
ND RINSE FEEDERS
E2 ELECTRIC CONNECTIO (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS WITH &
E3
,
PLUMBING CONNECTIONS:
D END OPTION IS SPECIFIED).
VENTILATION REQUIREMENTS:
BLE OF
95-3/8" AFF see note (f).
Electrical and grounding connection must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.
Plumbing connections must comply with applicable sanitar codes. vary, some methods are shown on this drawing.
SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS
MOTORS
SIZE
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (45-50 PSI WHEN EQUIPPED WITH AUTOCLEAN OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESSURE IS UNDER 15 PSI AT THE DISHWASHER, CONTAC
W/BLOWER DRYER, STEAM L-R
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF
W/O CIRCUIT BREAKERS:
ELECTRIC CONNECTION, MOTORS & CONTROLS 1" CONDUIT. 79-1/8" AFF
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER, MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION (FINAL RINSE WITH OR W/O THE AUTO CLEAN OPTION) 55°F WATER MINIMUM. 1" FPT, 1-1/2" AFF see notes (b) and (d).
P3 COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED). 2" FPT. 7" AFF
P4 COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA 2" FPT. 7" AFF
P5 COMMON STEAM CONNECTION (TANK HEAT). 1-1/2" FPT, 4-3/8" AFF (50 PSI MAX, 15-25 FLOWING PRESSURE) see note (e).
P7 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 16-15/16" AFF
P8 HOT WATER RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 15-9/16" AFF
P9 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT), BUCKET TYPE TRAPS FURNISHED, 3 CONNECTIONS. 3/4" FPT, 11" AFF
P10 C ONDENSATE RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER OPTION IS SPECIFIED), BUCKET TYPE TRAP FURNISHED. 3/4" FPT, 4-3/4" AFF
V1 MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
N, VENT FAN CONTROL.
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES (g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS (h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS.
MODEL NO.
FT1021 (2-1/2'-13'-5-1/2') FT1022 (3-1/2'-13'-5-1/2') FT1023 (4-1/2'-13'-5-1/2') FT1023 (2-1/2'-13'-7-1/2') FT1024 (3-1/2'-13'-7-1/2') FT1025 (4-1/2'-13'-7-1/2') FT1025 (2-1/2'-13'-9') FT1026 (3-1/2'-13'-9') FT1027 (4-1/2'-13'-9') FT1027 (2-1/2'-13'-11') 26' 10-7/8" FT1028 (3-1/2'-13'-11') 27' 10-5/8" FT1029 (4-1/2'-13'-11') 28' 10-15/32" FT1030 (2-1/2'-13'-15') FT1031 (3-1/2'-13'-15') FT1032 (4-1/2'-13'-15') FT1032 (2-1/2'-13'-17') 32' 5-3/4" FT1033 (3-1/2'-13'-17') 33' 5-1/2" FT1034 (4-1/2'-13'-17')
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
, ER, B/D)
M
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 17 of 20
VERY
TION
"A" "B" "C"
2' 7-1/2"
3' 7-1/4" 9' 2-1/4"
2' 7-1/2" 11' 1-7/8" 3' 7-1/4" 11' 1-7/8" 4' 7-3/32" 11' 1-7/8"
2' 7-1/2" 16' 8-3/4" 3' 7-1/4" 16' 8-3/4"
21' 4" 22' 3-3/4" 3' 7-1/4" 23' 3-19/32" 4' 7-3/32" 23' 3-1/2" 2' 7-1/2" 7' 6-1/2" 24' 3-1/4" 3' 7-1/4" 25' 3-3/32" 4' 7-3/32" 7' 6-1/2" 24' 11-1/4" 2' 7-1/2" 9' 2-1/4" 25' 11" 26' 10-27/32" 4' 7-3/32" 9' 2-1/4"
30' 6-3/16" 2' 7-1/2" 14' 9-3/16" 31' 5-15/16" 3' 7-1/4" 14' 9-3/16" 32' 5-25/32" 4' 7-3/32" 14' 9-3/16"
34' 5-11/32" 4' 7-3/32" 16' 8-3/4"
5' 7" 5' 7" 5' 7"
7' 6-1/2"
Drain and fill line configurations
y, safety and plumbing
(1) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE
(1) 10 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
RATED
AMPS
57.8
50.2
25.1
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
70 70 60 60 30 30
1/3 HP 1/4 HP
3 1/2 HP
5 HP
5 HP 1/6 HP 1/2 HP 1/3 HP 1/3 HP
s
MAXIMUM
PROTECTIVE
DEVICES
FT1000D ENERGY RECOVERY
Pressure gauge not required on pumped rinse machines. Important:
above floor If chemical containers are to be placed in cabinet adjacent to machine,
a 1/2" dia. hole is required in the cabinet to run chemical supply line Use only 6% or 8.4% sodium hypochlorite (liquid bleach) as sanitizing
chemical to insure proper operation of dishmachine Certain materials including silver plat
attacked manual.
Do not premix other chemicals and sodium hypochlorite (liquid bleach). Mixing may cause hazardous gas to form.
TE
SEE NO
FLOOR LINE
7 3/16"
3 15/16"
OVER FRAME "A"
60"
63 3/8"
6" MINIMUM
ON THE TOP
FLOOR LIN
NOTE: REFER TO LATEST
W/BLOWER DRYER, STEAM R-L
P2
P1
P4
32 15/16"
14 5/8"
5 7/8"
V1
11 13/16"
55 11/16"
52"
44 9/16"
P7
P10
P2
P5
P1
23 3/4"
P9
23 1/16"
28 15/16"
6 3/4"
P9
P5
28 7/16"
38 1/4"
11 5/8"
P6
23 1/8"
P6
P7
53 3/8"
22 5/8"
9 15/16"
P10
E1
88 3/4"
P8
E2
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
P8
E3
P8
15 11/16"
P8
18 3/4"
V1
P3 P4
2 5/8"
P3
37 1/2"
E1
E2
E3
V1
89 3/8"
TE (e)
36 1/4"
Page 18 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS REQUIRE 35" TO BE REMOVED. EXTRA CLEARANCE SHOULD BE PROVIDED.
35"
E
40 3/8"
44 13/16" see note (a)
UNLOAD
END
UNLOAD "C"
EXHAUST HOOD SUPPLIED BY OTHERS
43 5/16"
BLOWER/
DRYER
22" HIGH X 29-13/16" WIDE OPENING WILL HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL 24" RECOMMENDED, WITH DETERGENT DISPENSER
23 3/4"
6"
FNL RNS
AUX
RNS
5 3/4"
POWER
RINSE
POWER
WASH
DIRECTION OF OPERATION
Chemical containers should be placed no higher than 10"
.
by sodium hypochlorite (liquid bleach). See instructional
PRE-
WASH
35 7/16"35 7/16"35 7/16"25 9/16"
25 9/16"
ASR
e, aluminum and pewter are
LOAD "B"
3"
LOAD
END
.
6"
36 1/2"
.
62 3/4"
SEE NO
(f)
FT1000D ENERGY RECOVERY
GENERAL NOTES:
(
THE CONTROL
TION
CLEARANCE FOR DOORWAYS.
ELECTRICAL WARNING:
E
ITH
SERVICE WIRE TEMPERATURE RATING: 90C.
PLUMBING NOTES:
Y,
(b)
(
(d)
(
T
SALES ENGINEERING.
VENTILATION NOTES:
SH,
(j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
NO
MODEL: FT1000 ENERGY RECO (ASR STEA R-L OPERA 00-949506 REV A
ELECTRICAL CONNECTIONS COMMON ON
E1
ND RINSE FEEDERS
E2 ELECTRIC CONNECTIO (SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS WITH &
E3
,
PLUMBING CONNECTIONS:
D END OPTION IS SPECIFIED).
VENTILATION REQUIREMENTS:
BLE OF
95-3/8" AFF see note (f).
Electrical and grounding connection must comply with the applicable portions of the National Electrical Code and/or other local electrical codes.
Plumbing connections must comply with applicable sanitar codes. vary, some methods are shown on this drawing.
SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS
MOTORS
SIZE
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT. FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE. THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT. INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (45-50 PSI WHEN EQUIPPED WITH AUTOCLEAN OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESSURE IS UNDER 15 PSI AT THE DISHWASHER, CONTAC
W/BLOWER DRYER, STEAM R-L
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A (MACHINE SERVICE VOLTAGE), 1/2" CONDUIT. 79-1/8" AFF
W/O CIRCUIT BREAKERS:
ELECTRIC CONNECTION, MOTORS & CONTROLS 1" CONDUIT. 79-1/8" AFF
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER, MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION (FINAL RINSE WITH OR W/O THE AUTO CLEAN OPTION) 55°F WATER MINIMUM. 1" FPT, 1-1/2" AFF see notes (b) and (d).
P3 COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED). 2" FPT. 7" AFF
P4 COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA 2" FPT. 7" AFF
P5 COMMON STEAM CONNECTION (TANK HEAT). 1-1/2" FPT, 4-3/8" AFF (50 PSI MAX, 15-25 FLOWING PRESSURE) see note (e).
P7 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 16-15/16" AFF
P8 HOT WATER RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED) 3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 15-9/16" AFF
P9 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT), BUCKET TYPE TRAPS FURNISHED, 3 CONNECTIONS. 3/4" FPT, 11" AFF
P10 C ONDENSATE RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER OPTION IS SPECIFIED), BUCKET TYPE TRAP FURNISHED. 3/4" FPT, 4-3/4" AFF
V1 MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
N, VENT FAN CONTROL.
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES (g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS (h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS.
MODEL NO.
FT1021 (2-1/2'-13'-5-1/2') FT1022 (3-1/2'-13'-5-1/2') FT1023 (4-1/2'-13'-5-1/2') FT1023 (2-1/2'-13'-7-1/2') FT1024 (3-1/2'-13'-7-1/2') FT1025 (4-1/2'-13'-7-1/2') FT1025 (2-1/2'-13'-9') FT1026 (3-1/2'-13'-9') FT1027 (4-1/2'-13'-9') FT1027 (2-1/2'-13'-11') 26' 10-7/8" FT1028 (3-1/2'-13'-11') 27' 10-5/8" FT1029 (4-1/2'-13'-11') 28' 10-15/32" FT1030 (2-1/2'-13'-15') FT1031 (3-1/2'-13'-15') FT1032 (4-1/2'-13'-15') FT1032 (2-1/2'-13'-17') 32' 5-3/4" FT1033 (3-1/2'-13'-17') 33' 5-1/2" FT1034 (4-1/2'-13'-17')
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
, ER, B/D)
M
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 19 of 20
VERY
TION
"A" "B" "C"
2' 7-1/2"
3' 7-1/4" 9' 2-1/4"
2' 7-1/2" 11' 1-7/8" 3' 7-1/4" 11' 1-7/8" 4' 7-3/32" 11' 1-7/8"
2' 7-1/2" 16' 8-3/4" 3' 7-1/4" 16' 8-3/4"
21' 4" 22' 3-3/4" 3' 7-1/4" 23' 3-19/32" 4' 7-3/32" 23' 3-1/2" 2' 7-1/2" 7' 6-1/2" 24' 3-1/4" 3' 7-1/4" 25' 3-3/32" 4' 7-3/32" 7' 6-1/2" 24' 11-1/4" 2' 7-1/2" 9' 2-1/4" 25' 11" 26' 10-27/32" 4' 7-3/32" 9' 2-1/4"
30' 6-3/16" 2' 7-1/2" 14' 9-3/16" 31' 5-15/16" 3' 7-1/4" 14' 9-3/16" 32' 5-25/32" 4' 7-3/32" 14' 9-3/16"
34' 5-11/32" 4' 7-3/32" 16' 8-3/4"
5' 7" 5' 7" 5' 7"
7' 6-1/2"
Drain and fill line configurations
y, safety and plumbing
(1) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE
(1) 10 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3 240/60/3 480/60/3
RATED
AMPS
57.8
50.2
25.1
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
70 70 60 60 30 30
1/3 HP 1/4 HP
3 1/2 HP
5 HP
5 HP 1/6 HP 1/2 HP 1/3 HP 1/3 HP
s
MAXIMUM
PROTECTIVE
DEVICES
FT1000D ENERGY RECOVERY FLIGHT-TYPE DISHWASHER
FT (ight type) Models—many additional variations of these model specications are available. Engineering data furnished on request. Numbers in parentheses, after model number from left to right, represent length in feet of the following respectively; Loading section, Washing and Power Rinsing sections, Unloading section.
Flight-type dishwasher with BLOWER-DRYER has the same specications as the Basic FT1000 Series EXCEPT for one additional Blower Motor (2 H.P. — 208-240/60/3 and 480/60/3) and is available on any model having either a 5* (without blower dryer), 7, 9, 11 or 13 foot unloading section.
Entire FT1000 Series is listed by UL and NSF and
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
meets requirements of ASSE Standard No. 1004.
FT1000 Series
(7, 9, 11 Load / 8 Center / 5*, 7, 9, 11, 13 Unload)
Machine Ratings (Mechanical)
Conveyor Speed — Feet per minute 6.5 - 8.5
Dishes per Hour 14,316
Overall Dimensions (H x W) — inches (standard height) 8011⁄16 (C) x 47 (B)
Motor — Horsepower ASR Soil - 1⁄4; ASR Wash - 1⁄3; Pre-Wash - 3; Wash - 5; Rinse - 5;
Tank Capacity — Gallons ASR - 5.6; Pre-Wash - 40; Wash - 40; Rinse - 40; Dual Rinse - 5.6
Pump Capacity
Gallons per minute—Weir Test Pre-Wash - 150; Wash - 292; Rinse - 292
Final Rinse Minutes of operation during one hour of continuous operation 60 at continuous loading condition
Rate of Final Rinse — Gallons per minute at 20 PSI ow pressure .98
Final Rinse Consumption — Gallons per hour at 20 PSI ow pressure 58
Exhaust Requirements — Cubic feet per minute with Blower Dryer
Electric Heat Requirements
Tank Heat - Kilowatt (Regulated)
Optional Electric Booster - Kilowatt
Optional Blower Dryer — Kilowatt 7.5 KW (functions only during conveyor operation)
Steam Heat Requirements
Steam Consumption
Tank Heat - Pounds per hour - maximum (Regulated) - based on 15 to 52 PSI steam at the machine and on the customer supplying nal rinse water at minimum (A) (20 PSIG)
Optional Steam Booster - Pounds per hour - maximum
- based on 20 PSI steam at 20 PSI water owing ­ 120°F incoming water raised to 190°F (70°F rise) (180°F minimum)
Peak Rate of Drain Flow — Gallons per minute Initial rate with full tanks 38
Shipping Weight Crated Varies by individual model - consult your Hobart representative
Disconnect switches are recommended for each power circuit connected
to dishwasher. These disconnect switches are NOT furnished by Hobart
and should be installed by the electrical contractor at the time of installation.
18KW - 110°F incoming water raised to 190°F (85°F rise) (180°F minimum)
(A) If only 10-12 PSIG Steam Pressure available at machine - specify Low Pressure Steam Option. (B) With all rear panels and plumbing removed, machine width is 391⁄8". (C) Highest item is control box - 8011⁄16". Can be adjusted lower 2" for door clearance. * 5 ft. unload available without blower dryer.
Conveyor - 1⁄3; Dual Rinse - 1⁄6; Final Rinse - 1⁄2
750
(at standard air conditions)
Circuit breakers optional at extra cost.
Total tank heat - 50KW (Wash, Rinse, Dual Rinse)
24 kw - 140° Incoming Water
Approximately 30 lbs. per hour = 1 boiler H.P. (BHP)
175 lbs./150°F Wash minimum/160°F Rinse minimum
99 lbs.
As continued product improvement is a policy of Hobart, specications are subject to change without notice.
Page 20 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
F40351 (01/14) LITHO IN U.S.A. (H-01)