Item # _____________________________________
Quantity ___________________________________
C.S.I. Section 11400
FT1000D ENERGY RECOVERY
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
STANDARD FEATURES
■ Pumped rinse system
■ Water usage 58 gph
■ Digital controls with machine diagnostics
■ Low temperature alert
■ Single point vent connection
■ 36" access doors on prewash, power wash and
power rinse chambers, 25" door access on dual
rinse chamber and ASR chamber
■ Start and stop switches at both ends
■ Doors open indicator
■ Drains open indicator
■ Door interlocks
■ 3 H.P. prewash, and 5 H.P. power wash and
power rinse pump motors, all TEFC
■ Capless Auto Clean wash arms
■ Easy to remove scrap trays and baskets
■ Deep drawn tanks without welds
■ 30" wide conveyor belt
■ Dual Rinse
■ Automatic Soil Removal system (ASR)
■ Auto Clean feature
■ Auto Delime feature
■ Energy Recovery
■ Front and rear panels
■ Variable speed conveyor
FLIGHT-TYPE DISHWASHER
MODEL
❑ FT1000D Energy Recovery Flight-Type
Dishwasher
OPTIONS AT EXTRA COST
❑ Electric Tank Heat
❑ Steam Tank Heat
❑ Booster Heater
❑ Electric
❑ Steam
❑ Blower Dryer
❑ Electric
❑ Steam
❑ 6" higher than standard chamber
❑ Multiple conveyor choices
❑ Circuit breakers
❑ Other options available, consult factory
ACCESSORIES
❑ Feet
❑ Extended
❑ Flanged
❑ Water hammer arrestor/PRV
Specications, Details and Dimensions on Inside and Back.
FT1000D ENERGY RECOVERY FLIGHT-TYPE DISHWASHER
UL, NSF and LA approvals pending
DIRECTION OF OPERATION
❑ Right to Left
❑ Left to Right
VOLTAGE
❑ 208/60/3
❑ 240/60/3
❑ 480/60/3
❑ Other voltages available – consult factory
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 1 of 20
FT1000D ENERGY RECOVERY
FLIGHT-TYPE DISHWASHER
DESIGN: Fully automatic, ight-type dish machine
consisting of a load section with Automatic Soil
Removal system, power recirculating prewash, power
wash, power rinse, dual rinse and nal rinse section.
Included with each machine will be exible plastic
strip curtains to control overspray.
CONSTRUCTION: Stainless steel tank and chambers
with No. 3 polish on appearance surfaces. Frame,
legs and feet to be constructed of stainless steel.
Inspection doors to be chamber width.
PUMPS: Recirculating stainless steel pumps with
stainless steel impellers. Pump housing has easy to
remove coverplate for access to impeller. All pumps
are self-draining.
MOTORS: Totally enclosed fan cooled (TEFC) design
with overload protection. Pump motors to be 3 H.P.
for prewash and 5 H.P. for power wash and power
rinse, with conveyor motor to be 1⁄3 H.P. Available in
electrical specications of 208/60/3, 240/60/3 and
480/60/3.
CONTROLS: A stainless steel control center with
electronic digital controls mounted at eye level.
Power “On/Off” and “Start/Stop” switches integrated
into keypad. Digital display indicates door(s) open,
low temperature alert, tanks/nal rinse temperatures,
Auto Clean and Auto Delime instructions and notications, and other pertinent operating data. Additional
“Start/Stop” switches are located at each end of
machine. Conveyor speed button included on the
control center to provide for the adjustable speed
conveyor.
FLIGHT-TYPE CONVEYOR: Stainless steel side
links, tie rods and conveyor tracks. Injection molded,
resilient Duraex ight links.
VENT: Single built-in vent duct with dampers
mounted in ventilation stack.
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
AUTOMATIC SOIL REMOVAL SYSTEM (ASR):
Two foot section with specialized soil removal wash
arms removes food soil from the machine before it
reaches the prewash tank. System will pump food soil
from the ASR tank into an external collector located
under the load section, minimizing the need to
pre-scrap dishes and reducing detergent consumption. Operator can easily remove and clean external
collector without interruption of machine operation.
RECIRCULATING PREWASH SECTION: Prewash
compartment is tted with upper and lower wash
arms. Prewash ush down for prewash tank bed.
Large removable one piece perforated stainless steel
screen sloped downward to deep stainless steel
scrap basket.
TANK HEAT: Power wash, power rinse and dual
rinse tank water temperatures are thermostatically
controlled. Low water protection is provided. Specify
either electric or steam heat.
FINAL RINSE: Easily removed nal rinse arms.
ENERGY RECOVERY: Energy Recovery system
operates with a cold water line, capturing energy from
exhaust air, and using it to elevate the temperature
of the water entering the booster heater. The result is
savings – both in hot water and in energy.
CONVEYOR DRIVE UNIT: Powered by a 1⁄ 3 H.P.
motor. Trip mechanism provided on unload section.
Jam protection is provided by load sensing switch
at drive platform. Conveyor speed adjustment of 6.5
feet per minute to 8.5 feet per minute is provided on
the digital display keypad.
DRAINS: Manual, hand-operated, located in each
tank.
One automatic master drain to be used for Auto
Clean and Auto Delime.
BLOWER DRYER (OPTIONAL): Includes (2) 1 H.P.
fan motors with sealed ball bearings and overload
protection. Blower functions only during conveyor
operation.
Page 2 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
FT1000D ENERGY RECOVERY
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
No other control
system allows
easier monitoring.
The digital controls are
placed in a convenient
panel that lets operators verify proper operation and
temperatures at a glance. Digital display indicates
the unit is on, and conrms that the doors are
closed. Automatic door interlocks prevent the pump
and conveyor from operating if the doors are open.
Easy-to-read digital display indicates accurate temperatures of the 150°F wash, 160°F power rinse,
160°F dual rinse and 180°F nal rinse — critical for
proper HACCP system record-keeping.
Stainless steel pump is built for long life.
The stainless steel pump housing and impeller offer
greater durability and long life. The pump motor is
totally enclosed and fan cooled (TEFC) to protect it
from water spray during dishroom clean-up.
Scrap baskets
capture food particles
and are easy to clean.
The sloped screens that
carry scraps to the scrap
baskets are steeper, so less
soil gets into the tanks. The basket
opening is larger for easy cleaning and basket
handles have been designed for easy lift-out access.
The load section also features a removable scrap
basket which contains soil that is pumped from the
ASR section. All scrap baskets and strainers are
stainless steel for strength and durability.
The FT1000
Series saves
water and
energy.
The unit has the
lowest water
and energy
consumption in
the industry, yet
provides effective cleaning and sanitizing that meets
NSF International requirements.
This is achieved through
a carefully balanced ratio
of water ow to pressure.
Insulated doors and thermal
layered curtain at load also
reduce heat loss. The unit’s
58 gallons per hour rinse ow
rate saves both water and the
energy to heat it.
FLIGHT-TYPE DISHWASHER
Wider, variable
speed conveyor
offers increased
throughput.
The conveyor
on the FT1000
Series is wider
so it can handle
more ware.
Result: more volume and versatility, quicker work. Its
speed is easily adjustable for the type of ware, soiled
condition, or workforce requirements. It runs at 6.5 -
8.5 feet per minute.
Energy Recovery system
reclaims heat for energy.
The Energy Recovery
system captures escaping
heat and steam from the
exhaust air and uses a heat
exchanger to recycle it into
energy. This free energy is
used to preheat the incoming water supply before it
enters the booster heater.
The cold ground temperature water passes through
a heat exchanger positioned directly in line with the
machine’s exhaust system to capture the energy
from the exhaust air to elevate the temperature of the
water to 128° before it enters the booster heater.
Self-draining pumps help keep water clean.
Pumps are self-draining when the machine is shut
down, so there is no residual water left in the pumps.
Installation is quick and easy with modular design,
minimal wiring connections, and single point vent.
Modular design means
the FT1000 installs quickly
and reliably. Sections t
through 42" doors. The
control panel is already in
place, premounted to the
power wash/power rinse/
nal rinse section.
Wiring connections are
minimal, and there is only
a single vent connection,
saving time and expense.
The control box uses a
“single plane” circuitry
design for easy accessibility during installation and
service. The FT1000 is
ready to run quickly.
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 3 of 20
FT1000D ENERGY RECOVERY
NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
ELECTRIC L-R
18 3/4"
37 1/2"
E1
E2
E3
E4
E5
E6
E7
E8
E9
V1
P3 P4
2 5/8"
LOAD "B"
3"
P3
25 9/16"
9 15/16"
V1
E5
E4
E9
13' 1-9/16"
35 7/16" 35 7/16" 35 7/16" 25 9/16"
5 3/4"
11 13/16"
E3
E2
E1
E8
E6 E7
P2
P1
P4
60"
52"
44 9/16"
EXHAUST HOOD
SUPPLIED BY
OTHERS
23 3/4"
6"
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
P2
P1
23 3/4"
55 11/16"
UNLOAD "C"
V1
62 3/4"
TE
(f)
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS
REQUIRE 35" TO
BE REMOVED. EXTRA
CLEARANCE SHOULD BE
PROVIDED.
E
36 1/2"
LOAD
END
6"
35"
ASR
40 3/8"
44 13/16"
see note (a)
PRE-
WASH
DIRECTION OF OPERATION
22" HIGH X 29-13/16"
WIDE OPENING WILL
HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL
24" RECOMMENDED,
WITH DETERGENT DISPENSER
POWER
WASH
POWER
RINSE
AUX
FNL
RNS
RNS
FT1021 (2-1/2'-13'-5-1/2')
FT1022 (3-1/2'-13'-5-1/2')
FT1023 (4-1/2'-13'-5-1/2')
FT1023 (2-1/2'-13'-7-1/2')
FT1024 (3-1/2'-13'-7-1/2')
FT1025 (4-1/2'-13'-7-1/2')
FT1025 (2-1/2'-13'-9')
FT1026 (3-1/2'-13'-9')
FT1027 (4-1/2'-13'-9')
FT1027 (2-1/2'-13'-11')
FT1028 (3-1/2'-13'-11')
FT1029 (4-1/2'-13'-11')
FT1030 (2-1/2'-13'-15')
FT1031 (3-1/2'-13'-15')
FT1032 (4-1/2'-13'-15')
FT1032 (2-1/2'-13'-17')
FT1033 (3-1/2'-13'-17')
FT1034 (4-1/2'-13'-17')
MODEL NO.
UNLOAD
END
"A" "B" "C"
21' 4"
22' 3-3/4" 3' 7-1/4"
23' 3-19/32" 4' 7-3/32"
23' 3-1/2" 2' 7-1/2"
24' 3-1/4" 3' 7-1/4"
25' 3-3/32" 4' 7-3/32"
24' 11-1/4" 2' 7-1/2"
25' 11"
26' 10-27/32" 4' 7-3/32"
26' 10-7/8"
27' 10-5/8"
28' 10-15/32"
30' 6-3/16" 2' 7-1/2"
31' 5-15/16" 3' 7-1/4"
32' 5-25/32" 4' 7-3/32"
32' 5-3/4"
33' 5-1/2"
34' 5-11/32" 4' 7-3/32"
36 1/4"
2' 7-1/2"
3' 7-1/4"
2' 7-1/2"
3' 7-1/4"
4' 7-3/32"
2' 7-1/2"
3' 7-1/4"
89 3/8"
SEE NO
5' 7"
5' 7"
5' 7"
7' 6-1/2"
7' 6-1/2"
7' 6-1/2"
9' 2-1/4"
9' 2-1/4"
9' 2-1/4"
11' 1-7/8"
11' 1-7/8"
11' 1-7/8"
14' 9-3/16"
14' 9-3/16"
14' 9-3/16"
16' 8-3/4"
16' 8-3/4"
16' 8-3/4"
Page 4 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
FT1000D ENERGY RECOVERY
SERVICE WIRE TEMPERATURE RATING: 90C.
Do not premix other chemicals and sodium
hypochlorite (liquid bleach).
Mixing may cause hazardous gas to form.
Electrical and grounding connections
must comply with the applicable portions
of the National Electrical Code and/o
other local electrical codes.
Plumbing connections must comply with
applicable sanitar
codes.
vary, some methods are shown on this drawing.
,
a 1/2" dia.
Use only 6%
MODEL:
FT1000 ENERGY RECO
(ASR
ELECTRIC
L-R OPERA
00-949505
REV A
ELECTRICAL CONNECTIONS
COMMON ON
E2 ELECTRIC CONNECTION
(SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
W/O CIRCUIT BREAKERS:
E3
E7
1" CONDUIT. 79-1/8" AFF
1-1/4" CONDUIT, 79-1/8" AFF
D END OPTION IS SPECIFIED).
2" FPT. 7" AFF
VENTILATION REQUIREMENTS:
V1
95-3/8" AFF see note (f).
SERVICE CONNECTION W/O CIRCUIT BREAKERS
ELECTRIC TANK HEAT, BOOSTER
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT
THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK
AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR
ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT.
FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT.
INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W
THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE
AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR
SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE
DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (40-45 PSI WHEN EQUIPPED WITH AUTOCLEAN
OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT
SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR
EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER
SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESSURE IS UNDER 15 PSI AT THE DISHWASHER, CONTAC
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES
(g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS
(h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS.
(j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
y, safety and plumbing
Drain and fill line configurations
e gauge not required on pumped rinse machines.
Chemical c ontainers sh ould be plac ed no higher than 10"
ve floor.
emical conta iners are to be placed in cabinet ad jacent to ma chine
hole is req uired in the cabinet to r un chemical supply line.
or 8.4% sod ium hypochlor ite (liquid bleach) as sanitizing
to insure proper operat ion of dishmachine.
materials in cluding silv er plate, aluminum and pewter a re
by sodium hyp ochlorite (li quid bleach). See instruc tional
, ER)
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 5 of 20
VERY
TION
r
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A
(MACHINE SERVICE VOLTAGE), 1/2" CONDUIT.
79-1/8" AFF
ELECTRIC CONNECTION, MOTORS & CONTROLS,
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, POWER RINSE TANK, 20 KW
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, WASH TA NK, 20 KW.
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, D UAL RINSE TANK, 10KW.
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, B OOSTER, 18KW.
WITH CIRCUIT BREAKERS:
E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, RINSE HEAT,
BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED)
(TB1) 2" CONDUIT, 79-1/8" AFF
E9 ELECTRIC CONNECTION, WASH HEAT & DUAL RINSE HEAT (TB2)
COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER,
MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
AUTO CLEAN OPTION) 55°F WATER MINIMUM.
1" FPT, 5-1/2" AFF see notes (b) and (d).
COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED).
2" FPT. 7" AFF
COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA
MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA
PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
SERVICE CONNECTION WITH CIRCUIT BREAKERS
(2) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS, CONTROLS, POWER RINSE & BOOSTER HEAT(TB1)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
(5) SERVICE CONNECTIONS AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
RATED
AMPS
156.3
144.9
72.4
WASH, DUAL RINSE HEAT(TB2)
RATED
AMPS
96.1 125 125
91.6 125 125
45.8 60 60
ELECTRIC TANK HEAT, DUAL RINSE
(1) 10KW CONNECTION AS SHOWN BELOW
RATED
AMPS
30.0
28.6
14.3
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
200 200
175 175
90 90
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
35 35
35 35
20 20
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
WATER CONNECTION (FINAL RINSE WITH OR W/O THE
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICE
MAXIMUM
PROTECTIVE
DEVICES
1/3 HP
1/4 HP
3 1/2 HP
5 HP
5 HP
1/6 HP
1/2 HP
1/3 HP
1/3 HP
ELECTRIC L-R
, VENT FAN CONTROL.
ELECTRIC TANK HEAT, POWER RINSE
(1) 18 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
(1) 22 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
(1) 18 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
RATED
AMPS
54.0 70 70
51.5 70 70
25.8 35 35
RATED
AMPS
66.0 80 80
63.0 80 80
31.5 40 40
RATED
AMPS
54.0 70 70
51.5 70 70
RATED
AMPS
48.2 60 60
41.8 50 50
20.9 25 25
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICE
FT1000D ENERGY RECOVERY
7 7/8"
OVER FRAME "A"
3 15/16"
NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
ELECTRIC R-L
P2
P1
23 3/4"
55 11/16"
V1
UNLOAD "C"
60"
52"
44 9/16"
EXHAUST HOOD
SUPPLIED BY
OTHERS
23 3/4"
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
P2
P1
P4
18 3/4"
V1
P3 P4
2 5/8"
P3
9 15/16"
V1
E5
E1
E6 E7
E2
E3
E8
5 3/4"
E4
E9
13' 1-9/16"
35 7/16" 35 7/16" 35 7/16" 25 9/16"
25 9/16"
LOAD "B"
3"
11 13/16"
6"
37 1/2"
E1
E2
E3
E4
E5
E6
E7
E8
E9
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS
REQUIRE 35" TO
BE REMOVED. EXTRA
CLEARANCE SHOULD BE
PROVIDED.
E
89 3/8"
TE (e)
35"
36 1/4"
40 3/8"
44 13/16"
see note (a)
UNLOAD
END
22" HIGH X 29-13/16"
WIDE OPENING WILL
HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL
24" RECOMMENDED,
WITH DETERGENT DISPENSER
FNL
RNS
AUX
RNS
POWER
RINSE
POWER
WASH
DIRECTION OF OPERATION
MODEL NO.
FT1021 (2-1/2'-13'-5-1/2')
FT1022 (3-1/2'-13'-5-1/2')
FT1023 (4-1/2'-13'-5-1/2')
FT1023 (2-1/2'-13'-7-1/2')
FT1024 (3-1/2'-13'-7-1/2')
FT1025 (4-1/2'-13'-7-1/2')
FT1025 (2-1/2'-13'-9')
FT1026 (3-1/2'-13'-9')
FT1027 (4-1/2'-13'-9')
FT1027 (2-1/2'-13'-11')
FT1028 (3-1/2'-13'-11')
FT1029 (4-1/2'-13'-11')
FT1030 (2-1/2'-13'-15')
FT1031 (3-1/2'-13'-15')
FT1032 (4-1/2'-13'-15')
FT1032 (2-1/2'-13'-17')
FT1033 (3-1/2'-13'-17')
FT1034 (4-1/2'-13'-17')
PRE-
WASH
21' 4"
22' 3-3/4" 3' 7-1/4"
23' 3-19/32" 4' 7-3/32"
23' 3-1/2" 2' 7-1/2"
24' 3-1/4" 3' 7-1/4"
25' 3-3/32" 4' 7-3/32"
24' 11-1/4" 2' 7-1/2"
25' 11"
26' 10-27/32" 4' 7-3/32"
26' 10-7/8"
27' 10-5/8"
28' 10-15/32"
30' 6-3/16" 2' 7-1/2"
31' 5-15/16" 3' 7-1/4"
32' 5-25/32" 4' 7-3/32"
32' 5-3/4"
33' 5-1/2"
34' 5-11/32" 4' 7-3/32"
ASR
"A" "B" "C"
LOAD
END
2' 7-1/2"
3' 7-1/4"
2' 7-1/2"
3' 7-1/4"
4' 7-3/32"
2' 7-1/2"
3' 7-1/4"
6"
5' 7"
5' 7"
5' 7"
7' 6-1/2"
7' 6-1/2"
7' 6-1/2"
9' 2-1/4"
9' 2-1/4"
9' 2-1/4"
11' 1-7/8"
11' 1-7/8"
11' 1-7/8"
14' 9-3/16"
14' 9-3/16"
14' 9-3/16"
16' 8-3/4"
16' 8-3/4"
16' 8-3/4"
36 1/2"
62 3/4"
SEE NO
(f)
Page 6 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
FT1000D ENERGY RECOVERY
SERVICE WIRE TEMPERATURE RATING: 90C.
Do not premix other chemicals and sodium
hypochlorite (liquid bleach).
Mixing may cause hazardous gas to form.
Electrical and grounding connections
must comply with the applicable portions
of the National Electrical Code and/o
other local electrical codes.
Plumbing connections must comply with
applicable sanitar
codes.
vary, some methods are shown on this drawing.
,
a 1/2" dia.
Use only 6%
MODEL:
FT1000 ENERGY RECO
(ASR
STEA
R-L OPERA
00-949504
REV A
ELECTRICAL CONNECTIONS
COMMON ON
E2 ELECTRIC CONNECTION
(SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
W/O CIRCUIT BREAKERS:
E3
E7
1" CONDUIT. 79-1/8" AFF
1-1/4" CONDUIT, 79-1/8" AFF
D END OPTION IS SPECIFIED).
2" FPT. 7" AFF
VENTILATION REQUIREMENTS:
V1
95-3/8" AFF see note (f).
SERVICE CONNECTION W/O CIRCUIT BREAKERS
ELECTRIC TANK HEAT, BOOSTER
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT
THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK
AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR
ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT.
FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT.
INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W
THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE
AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR
SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE
DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (40-45 PSI WHEN EQUIPPED WITH AUTOCLEAN
OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT
SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR
EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER
SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESSURE IS UNDER 15 PSI AT THE DISHWASHER, CONTAC
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES
(g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS
(h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS.
(j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
y, safety and plumbing
Drain and fill line configurations
e gauge not required on pumped rinse machines.
Chemical c ontainers sh ould be plac ed no higher than 10"
ve floor.
emical conta iners are to be placed in cabinet ad jacent to ma chine
hole is req uired in the cabinet to r un chemical supply line.
or 8.4% sod ium hypochlor ite (liquid bleach) as sanitizing
to insure proper operat ion of dishmachine.
materials in cluding silv er plate, aluminum and pewter a re
by sodium hyp ochlorite (li quid bleach). See instruc tional
, ER)
M
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 7 of 20
VERY
TION
r
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A
(MACHINE SERVICE VOLTAGE), 1/2" CONDUIT.
79-1/8" AFF
ELECTRIC CONNECTION, MOTORS & CONTROLS,
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, POWER RINSE TANK, 20 KW
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, WASH TA NK, 20 KW.
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, D UAL RINSE TANK, 10KW.
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, B OOSTER, 18KW.
WITH CIRCUIT BREAKERS:
E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, RINSE HEAT,
BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED)
(TB1) 2" CONDUIT, 79-1/8" AFF
E9 ELECTRIC CONNECTION, WASH HEAT & DUAL RINSE HEAT (TB2)
COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER,
MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
AUTO CLEAN OPTION) 55°F WATER MINIMUM.
1" FPT, 5-1/2" AFF see notes (b) and (d).
COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED).
2" FPT. 7" AFF
COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA
MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA
PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
SERVICE CONNECTION WITH CIRCUIT BREAKERS
(2) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS, CONTROLS, POWER RINSE & BOOSTER HEAT(TB1)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
(5) SERVICE CONNECTIONS AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
RATED
AMPS
156.3
144.9
72.4
WASH, DUAL RINSE HEAT(TB2)
RATED
AMPS
96.1 125 125
91.6 125 125
45.8 60 60
ELECTRIC TANK HEAT, DUAL RINSE
(1) 10KW CONNECTION AS SHOWN BELOW
RATED
AMPS
30.0
28.6
14.3
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
200 200
175 175
90 90
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
35 35
35 35
20 20
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
WATER CONNECTION (FINAL RINSE WITH OR W/O THE
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICE
MAXIMUM
PROTECTIVE
DEVICES
1/3 HP
1/4 HP
3 1/2 HP
5 HP
5 HP
1/6 HP
1/2 HP
1/3 HP
1/3 HP
ELECTRIC R-L
, VENT FAN CONTROL.
ELECTRIC TANK HEAT, POWER RINSE
(1) 18 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
(1) 22 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
(1) 18 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
RATED
AMPS
54.0 70 70
51.5 70 70
25.8 35 35
RATED
AMPS
66.0 80 80
63.0 80 80
31.5 40 40
RATED
AMPS
54.0 70 70
51.5 70 70
RATED
AMPS
48.2 60 60
41.8 50 50
20.9 25 25
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICE
FT1000D ENERGY RECOVERY
Do not premix other chemicals and sodium
hypochlorite (liquid bleach).
Mixing may cause hazardous gas to form.
37 1/2"
E1
E2
E3
STEAM L-R
18 3/4"
V1
P4 P3
2 5/8"
P3
15 11/16"
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
P1
55 3/16"
P2
51 15/16"
P4
44 9/16"
33"
P10
14 11/16"
P6
P7
5 15/16"
E3
68 13/16"
P8
9 15/16"
E2
E1
33 3/8"
2 15/16"
11 13/16"
P8
P6
23 1/8"
V1
P9
28 7/16"
38 1/4"
P5
P8
P8
6 3/4"
P10
11 9/16"
21 3/4"
23"
P7
P1
P9
23 3/4"
P2
P5
28 15/16"
55 11/16"
LOAD "B"
3"
LOAD
END
62 3/4"
TE
(h)
36 1/2"
6"
Page 8 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS
REQUIRE 35" TO
BE REMOVED. EXTRA
CLEARANCE SHOULD BE
PROVIDED.
35"
E
25 9/16"
ASR
13' 1-9/16"
35 7/16" 35 7/16" 35 7/16" 25 9/16"
5 3/4"
POWER
WASH
22" HIGH X 29-13/16"
WIDE OPENING WILL
HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL
24" RECOMMENDED,
WITH DETERGENT DISPENSER
40 3/8"
44 13/16"
see note (a)
PREWASH
DIRECTION OF OPERATION
POWER
RINSE
AUX
RNS
FNL
RNS
UNLOAD "C"
EXHAUST HOOD
SUPPLIED BY
OTHERS
23 3/4"
6"
UNLOAD
END
mportant: Chemical containers should be placed no higher than 10"
bove floor.
f chemical c ontainers ar e to be place d in cabinet adjacent to machine
1/2" dia. h ole is requi red in the ca binet to run chemical supply line.
ertain mater ials includi ng silver pl ate, aluminum and p ewter are
ttacked by sod ium hypochlo rite (liquid bleach). See instructiona l
nual.
not required on pumped ri nse machines .
only 6% or 8.4% sodium hypochlorite (liquid blea ch) as sanitizing
insure prop er operation of dishmachi ne.
SEE NOTE (g
36 1/4"
V1
89 3/8"
FT1000D ENERGY RECOVERY
SERVICE WIRE TEMPERATURE RATING: 90C.
MODEL:
FT1000 ENERGY RECO
(ASR
STEA
L-R OPERA
00-949505
REV A
ELECTRICAL CONNECTIONS
COMMON ON
E2 ELECTRIC CONNECTION
(SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
WITH &
,
1" CONDUIT. 79-1/8" AFF
D END OPTION IS SPECIFIED).
VENTILATION REQUIREMENTS:
95-3/8" AFF see note (f).
vary, some methods are shown on this drawing.
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT
THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK
AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR
ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT.
FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT.
INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W
THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE
AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR
SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE
DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (40-45 PSI WHEN EQUIPPED WITH AUTOCLEAN
OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT
SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR
EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER
SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESURE IS UNDER 15 PSI AT THE DISHWASHER, CONTACT
STEAM L-R
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A
(MACHINE SERVICE VOLTAGE), 1/2" CONDUIT.
79-1/8" AFF
W/O CIRCUIT BREAKERS:
ELECTRIC CONNECTION, MOTORS & CONTROLS
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER,
MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION (FINAL RINSE WITH OR W/O THE
AUTO CLEAN OPTION) 55°F WATER MINIMUM.
1" FPT, 5-1/2" AFF see notes (b) and (d).
P3 COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED).
2" FPT. 7" AFF
P4 COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA
2" FPT. 7" AFF
P5 COMMON STEAM CONNECTION (TANK HEAT).
1-1/2" FPT, 4-3/8" AFF (50 PSI MAX, 15-25 FLOWING PRESSURE) see note (e).
P6 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED)
1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 16-15/16" AFF
P7 HOT RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED)
3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 15-9/16" AFF
P8 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT),
BUCKET TYPE TRAPS FURNISHED, 3 CONNECTIONS.
3/4" FPT, 11" AFF
P9 CONDENSAT E RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER OPTION
IS SPECIFIED), BUCKET TYPE TRAP FURNISHED.
3/4" FPT, 4-3/4" AFF
V1 MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA
PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
, VENT FAN CONTROL.
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES
(g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS
(h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS.
(j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
MODEL NO.
FT1021 (2-1/2'-13'-5-1/2')
FT1022 (3-1/2'-13'-5-1/2')
FT1023 (4-1/2'-13'-5-1/2')
FT1023 (2-1/2'-13'-7-1/2')
FT1024 (3-1/2'-13'-7-1/2')
FT1025 (4-1/2'-13'-7-1/2')
FT1025 (2-1/2'-13'-9')
FT1026 (3-1/2'-13'-9')
FT1027 (4-1/2'-13'-9')
FT1027 (2-1/2'-13'-11') 26' 10-7/8"
FT1028 (3-1/2'-13'-11') 27' 10-5/8"
FT1029 (4-1/2'-13'-11') 28' 10-15/32"
FT1030 (2-1/2'-13'-15')
FT1031 (3-1/2'-13'-15')
FT1032 (4-1/2'-13'-15')
FT1032 (2-1/2'-13'-17') 32' 5-3/4"
FT1033 (3-1/2'-13'-17') 33' 5-1/2"
FT1034 (4-1/2'-13'-17')
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
, ER)
M
VERY
TION
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 9 of 20
"A" "B" "C"
2' 7-1/2"
3' 7-1/4" 9' 2-1/4"
2' 7-1/2" 11' 1-7/8"
3' 7-1/4" 11' 1-7/8"
4' 7-3/32" 11' 1-7/8"
2' 7-1/2" 16' 8-3/4"
3' 7-1/4" 16' 8-3/4"
5' 7"
5' 7"
5' 7"
7' 6-1/2"
21' 4"
22' 3-3/4" 3' 7-1/4"
23' 3-19/32" 4' 7-3/32"
23' 3-1/2" 2' 7-1/2" 7' 6-1/2"
24' 3-1/4" 3' 7-1/4"
25' 3-3/32" 4' 7-3/32" 7' 6-1/2"
24' 11-1/4" 2' 7-1/2" 9' 2-1/4"
25' 11"
26' 10-27/32" 4' 7-3/32" 9' 2-1/4"
30' 6-3/16" 2' 7-1/2" 14' 9-3/16"
31' 5-15/16" 3' 7-1/4" 14' 9-3/16"
32' 5-25/32" 4' 7-3/32" 14' 9-3/16"
34' 5-11/32" 4' 7-3/32" 16' 8-3/4"
Electrical and grounding connections
must comply with the applicable portions
of the National Electrical Code and/or
other local electrical codes.
Plumbing connections must comply with
applicable sanitary, safety and plumbing
codes. Drain and fill line configurations
SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS
(1) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE
(1) 10 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
RATED
AMPS
48.2
41.8
20.9
MOTORS
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
60 60
50 50
25 25
SIZE
1/3 HP
1/4 HP
3 1/2 HP
5 HP
5 HP
1/6 HP
1/2 HP
1/3 HP
1/3 HP
MAXIMUM
PROTECTIVE
DEVICES
FT1000D ENERGY RECOVERY
Do not premix other chemicals and sodium
hypochlorite (liquid bleach).
Mixing may cause hazardous gas to form.
7 7/8"
3 15/16"
OVER FRAME "A"
STEAM R-L
P2
P9
P1
P5
23 3/4"
28 15/16"
55 11/16"
23 1/16"
11 5/8"
P7
6 3/4"
P10
P9
P5
28 7/16"
38 1/4"
52"
44 9/16"
P6
23 1/8"
P2
P1
P4
32 15/16"
14 5/8"
5 7/8"
V1
11 13/16"
P6
P7
53 3/8"
22 5/8"
9 15/16"
P10
E1
88 3/4"
P8
E2
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
P8
E3
P8
15 11/16"
P8
18 3/4"
V1
P3 P4
2 5/8"
P3
37 1/2"
E1
E2
E3
V1
89 3/8"
TE (g)
36 1/4"
Page 10 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS
REQUIRE 35" TO
BE REMOVED. EXTRA
CLEARANCE SHOULD BE
PROVIDED.
35"
E
40 3/8"
44 13/16"
UNLOAD "C"
EXHAUST HOOD
SUPPLIED BY
OTHERS
23 3/4"
UNLOAD
END
22" HIGH X 29-13/16"
WIDE OPENING WILL
HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL
24" RECOMMENDED,
WITH DETERGENT DISPENSER
13' 1-9/16"
35 7/16" 35 7/16" 35 7/16" 25 9/16"
5 3/4"
6"
FNL
RNS
AUX
RNS
POWER
RINSE
POWER
WASH
DIRECTION OF OPERATION
mportant: Chemical containers should be placed no higher than 10"
bove floor.
f chemical c ontainers ar e to be place d in cabinet adjacent to machine
1/2" dia. h ole is requi red in the ca binet to run chemical supply line.
only 6% or 8.4% sodium hypochlorite (liquid blea ch) as sanitizing
ertain mater ials includi ng silver pl ate, aluminum and p ewter are
ttacked by sod ium hypochlo rite (liquid bleach). See instructiona l
nual.
PRE-
WASH
not required on pumped ri nse machines .
insure prop er operation of dishmachi ne.
25 9/16"
ASR
LOAD "B"
3"
LOAD
END
62 3/4"
SEE NO
(h)
36 1/2"
6"
FT1000D ENERGY RECOVERY
SERVICE WIRE TEMPERATURE RATING: 90C.
MODEL:
FT1000 ENERGY RECO
(ASR
STEA
R-L OPERA
00-949504
REV A
ELECTRICAL CONNECTIONS
COMMON ON
E2 ELECTRIC CONNECTION
(SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
WITH &
,
1" CONDUIT. 79-1/8" AFF
D END OPTION IS SPECIFIED).
VENTILATION REQUIREMENTS:
95-3/8" AFF see note (f).
vary, some methods are shown on this drawing.
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT
THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK
AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR
ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT.
FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT.
INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W
THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE
AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR
SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE
DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (40-45 PSI WHEN EQUIPPED WITH AUTOCLEAN
OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT
SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR
EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER
SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESURE IS UNDER 15 PSI AT THE DISHWASHER, CONTACT
STEAM R-L
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A
(MACHINE SERVICE VOLTAGE), 1/2" CONDUIT.
79-1/8" AFF
W/O CIRCUIT BREAKERS:
ELECTRIC CONNECTION, MOTORS & CONTROLS
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER,
MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION (FINAL RINSE WITH OR W/O THE
AUTO CLEAN OPTION) 55°F WATER MINIMUM.
1" FPT, 5-1/2" AFF see notes (b) and (d).
P3 COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED).
2" FPT. 7" AFF
P4 COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA
2" FPT. 7" AFF
P5 COMMON STEAM CONNECTION (TANK HEAT).
1-1/2" FPT, 4-3/8" AFF (50 PSI MAX, 15-25 FLOWING PRESSURE) see note (e).
P6 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED)
1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 16-15/16" AFF
P7 HOT RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED)
3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 15-9/16" AFF
P8 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT),
BUCKET TYPE TRAPS FURNISHED, 3 CONNECTIONS.
3/4" FPT, 11" AFF
P9 CONDENSAT E RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER OPTION
IS SPECIFIED), BUCKET TYPE TRAP FURNISHED.
3/4" FPT, 4-3/4" AFF
V1 MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA
PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
, VENT FAN CONTROL.
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES
(g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS
(h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS.
(j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
MODEL NO.
FT1021 (2-1/2'-13'-5-1/2')
FT1022 (3-1/2'-13'-5-1/2')
FT1023 (4-1/2'-13'-5-1/2')
FT1023 (2-1/2'-13'-7-1/2')
FT1024 (3-1/2'-13'-7-1/2')
FT1025 (4-1/2'-13'-7-1/2')
FT1025 (2-1/2'-13'-9')
FT1026 (3-1/2'-13'-9')
FT1027 (4-1/2'-13'-9')
FT1027 (2-1/2'-13'-11') 26' 10-7/8"
FT1028 (3-1/2'-13'-11') 27' 10-5/8"
FT1029 (4-1/2'-13'-11') 28' 10-15/32"
FT1030 (2-1/2'-13'-15')
FT1031 (3-1/2'-13'-15')
FT1032 (4-1/2'-13'-15')
FT1032 (2-1/2'-13'-17') 32' 5-3/4"
FT1033 (3-1/2'-13'-17') 33' 5-1/2"
FT1034 (4-1/2'-13'-17')
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
, ER)
M
VERY
TION
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 11 of 20
"A" "B" "C"
2' 7-1/2"
3' 7-1/4" 9' 2-1/4"
2' 7-1/2" 11' 1-7/8"
3' 7-1/4" 11' 1-7/8"
4' 7-3/32" 11' 1-7/8"
2' 7-1/2" 16' 8-3/4"
3' 7-1/4" 16' 8-3/4"
5' 7"
5' 7"
5' 7"
7' 6-1/2"
21' 4"
22' 3-3/4" 3' 7-1/4"
23' 3-19/32" 4' 7-3/32"
23' 3-1/2" 2' 7-1/2" 7' 6-1/2"
24' 3-1/4" 3' 7-1/4"
25' 3-3/32" 4' 7-3/32" 7' 6-1/2"
24' 11-1/4" 2' 7-1/2" 9' 2-1/4"
25' 11"
26' 10-27/32" 4' 7-3/32" 9' 2-1/4"
30' 6-3/16" 2' 7-1/2" 14' 9-3/16"
31' 5-15/16" 3' 7-1/4" 14' 9-3/16"
32' 5-25/32" 4' 7-3/32" 14' 9-3/16"
34' 5-11/32" 4' 7-3/32" 16' 8-3/4"
Electrical and grounding connections
must comply with the applicable portions
of the National Electrical Code and/or
other local electrical codes.
Plumbing connections must comply with
applicable sanitary, safety and plumbing
codes. Drain and fill line configurations
SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS
(1) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE
(1) 10 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
RATED
AMPS
48.2
41.8
20.9
MOTORS
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
60 60
50 50
25 25
SIZE
1/3 HP
1/4 HP
3 1/2 HP
5 HP
5 HP
1/6 HP
1/2 HP
1/3 HP
1/3 HP
MAXIMUM
PROTECTIVE
DEVICES
FT1000D ENERGY RECOVERY
FLOOR LINE
7 3/16"
3 15/16"
NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
W/BLOWER DRYER, ELECTRIC L-R
18 3/4"
37 1/2"
E1
E2
E3
E4
E5
E6
E7
E8
E9
V1
P3 P4
2 5/8"
P3
9 15/16"
E5
E3
E4
E2
E1
E8
E9
E6 E7
25 9/16"
3"
35 7/16" 35 7/16" 35 7/16" 25 9/16"
5 3/4"
11 13/16"
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
P2
P1
P4
V1
52"
44 9/16"
EXHAUST HOOD
SUPPLIED BY OTHERS
43 5/16"
23 3/4"
6"
60"
P2
P1
23 3/4"
55 11/16"
UNLOAD "C" LOAD "B"
V1
62 3/4"
TE
(f)
36 1/2"
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS
REQUIRE 35" TO
BE REMOVED. EXTRA
CLEARANCE SHOULD BE
PROVIDED.
E
BLOWER/
DRYER
LOAD
END
6"
35"
ASR
40 3/8"
44 13/16"
see note (a)
PRE-
WASH
DIRECTION OF OPERATION
22" HIGH X 29-13/16"
WIDE OPENING WILL
HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL
24" RECOMMENDED,
WITH DETERGENT DISPENSER
POWER
WASH
POWER
RINSE
AUX
FNL
RNS
RNS
MODEL NO.
FT1021 (2-1/2'-13'-5-1/2')
FT1022 (3-1/2'-13'-5-1/2')
FT1023 (4-1/2'-13'-5-1/2')
FT1023 (2-1/2'-13'-7-1/2')
FT1024 (3-1/2'-13'-7-1/2')
FT1025 (4-1/2'-13'-7-1/2')
FT1025 (2-1/2'-13'-9')
FT1026 (3-1/2'-13'-9')
FT1027 (4-1/2'-13'-9')
FT1027 (2-1/2'-13'-11') 26' 10-7/8"
FT1028 (3-1/2'-13'-11') 27' 10-5/8"
FT1029 (4-1/2'-13'-11') 28' 10-15/32"
FT1030 (2-1/2'-13'-15')
FT1031 (3-1/2'-13'-15')
FT1032 (4-1/2'-13'-15')
FT1032 (2-1/2'-13'-17') 32' 5-3/4"
FT1033 (3-1/2'-13'-17') 33' 5-1/2"
FT1034 (4-1/2'-13'-17')
UNLOAD
END
36 1/4"
"A" "B" "C"
21' 4"
22' 3-3/4" 3' 7-1/4"
23' 3-19/32" 4' 7-3/32"
23' 3-1/2" 2' 7-1/2" 7' 6-1/2"
24' 3-1/4" 3' 7-1/4"
25' 3-3/32" 4' 7-3/32" 7' 6-1/2"
24' 11-1/4" 2' 7-1/2" 9' 2-1/4"
25' 11"
26' 10-27/32" 4' 7-3/32" 9' 2-1/4"
30' 6-3/16" 2' 7-1/2" 14' 9-3/16"
31' 5-15/16" 3' 7-1/4" 14' 9-3/16"
32' 5-25/32" 4' 7-3/32" 14' 9-3/16"
34' 5-11/32" 4' 7-3/32" 16' 8-3/4"
2' 7-1/2"
3' 7-1/4" 9' 2-1/4"
2' 7-1/2" 11' 1-7/8"
3' 7-1/4" 11' 1-7/8"
4' 7-3/32" 11' 1-7/8"
2' 7-1/2" 16' 8-3/4"
3' 7-1/4" 16' 8-3/4"
89 3/8"
SEE NOTE (e
5' 7"
5' 7"
5' 7"
7' 6-1/2"
Page 12 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
FT1000D ENERGY RECOVERY
SERVICE WIRE TEMPERATURE RATING: 90C.
Do not premix other chemicals and sodium
hypochlorite (liquid bleach).
Mixing may cause hazardous gas to form.
Electrical and grounding connection
must comply with the applicable portions
of the National Electrical Code and/or
other local electrical codes.
Plumbing connections must comply with
applicable sanitar
codes.
vary, some methods are shown on this drawing.
Pressure gauge not required on pumped rinse machines.
Important:
above floor
If chemical containers are to be placed in cabinet adjacent to machine,
a 1/2" dia. hole is required in the cabinet to run chemical supply line
Use only 6% or 8.4% sodium hypochlorite (liquid bleach) as sanitizing
chemical to insure proper operation of dishmachine
Certain materials including silver plat
MODEL:
FT1000 ENERGY RECO
(ASR
ELECTRIC
L-R OPERA
00-949507
REV A
ELECTRICAL CONNECTIONS
COMMON ON
E2 ELECTRIC CONNECTIO
(SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
W/O CIRCUIT BREAKERS:
E3
E7
1" CONDUIT. 79-1/8" AFF
1-1/4" CONDUIT, 79-1/8" AFF
D END OPTION IS SPECIFIED).
2" FPT. 7" AFF
VENTILATION REQUIREMENTS:
V1
95-3/8" AFF see note (f).
SERVICE CONNECTION W/O CIRCUIT BREAKERS
ELECTRIC TANK HEAT, BOOSTER
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT
THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK
AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR
ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT.
FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT.
INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W
THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE
AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR
SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE
DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (45-50 PSI WHEN EQUIPPED WITH AUTOCLEAN
OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT
SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR
EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER
SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESSURE IS UNDER 15 PSI AT THE DISHWASHER, CONTAC
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES
(g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS
(h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS.
(j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
y, safety and plumbing
Drain and fill line configurations
Chemical containers should be placed no higher than 10"
.
by sodium hypochlorite (liquid bleach). See instructional
, ER, B/D)
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 13 of 20
TION
e, aluminum and pewter are
VERY
s
.
W/BLOWER DRYER, ELECTRIC L-R
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A
(MACHINE SERVICE VOLTAGE), 1/2" CONDUIT.
79-1/8" AFF
ELECTRIC CONNECTION, MOTORS & CONTROLS,
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, POWER RINSE TANK, 20 KW
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, WASH TA NK, 20 KW.
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, D UAL RINSE TANK, 10KW.
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, B OOSTER, 18KW.
WITH CIRCUIT BREAKERS:
E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, RINSE HEAT,
BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED)
(TB1) 2" CONDUIT, 79-1/8" AFF
E9 ELECTRIC CONNECTION, WASH HEAT & DUAL RINSE HEAT (TB2)
COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER,
MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
AUTO CLEAN OPTION) 55°F WATER MINIMUM.
1" FPT, 1-1/2" AFF see notes (b) and (d).
COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED).
2" FPT. 7" AFF
COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA
MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA
PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
SERVICE CONNECTION WITH CIRCUIT BREAKERS
(2) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS, CONTROLS, POWER RINSE & BOOSTER HEAT(TB1)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
(5) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE, B/D HEAT & BLOWERS
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
.
SPECS.
208/60/3
240/60/3
480/60/3
RATED
AMPS
156.3
144.9
72.4
WASH, DUAL RINSE HEAT(TB2)
RATED
AMPS
128.2 150 150
121.5 150 150
60.7 75 75
RATED
AMPS
62.1
58.5
29.3
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
200
175 175
90 90
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
80 80
70 70
35 35
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
N, VENT FAN CONTROL.
WATER CONNECTION (FINAL RINSE WITH OR W/O THE
ELECTRIC TANK HEAT, POWER RINSE
(1) 18KW CONNECTION AS SHOWN BELOW
MAXIMUM
PROTECTIVE
DEVICES
200
MAXIMUM
PROTECTIVE
DEVICE
MAXIMUM
PROTECTIVE
DEVICES
1/3 HP
1/4 HP
3 1/2 HP
5 HP
5 HP
1/6 HP
1/2 HP
1/3 HP
1/3 HP
ELEC.
SPECS.
208/60/3
240/60/3
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
ELEC.
SPECS.
208/60/3
240/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
RATED
AMPS
(1) 22 KW CONNECTION AS SHOWN BELOW
RATED
AMPS
(1) 18 KW CONNECTION AS SHOWN BELOW
RATED
54.0 70 70
51.5 70 70
25.8 35 35
66.0 80 80
63.0 80 80
31.5 40 40
RATED
AMPS
54.07
51.57
AMPS
48.2 60 60
41.8 50 50
20.9 25 25
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
0
0
MAXIMUM
PROTECTIVE
DEVICE
FT1000D ENERGY RECOVERY
NOTE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
7 7/8"
OVER FRAME "A"
3 15/16"
W/BLOWER DRYER, ELECTRIC R-L
23 3/4"
6"
P2
P1
P4
V1
9 15/16"
11 13/16"
E1
E6 E7
5 3/4"
E5
E3
E4
E2
E8
E9
55 11/16"
P2
P1
23 3/4"
60"
52"
44 9/16"
UNLOAD "C"
EXHAUST HOOD
SUPPLIED BY
OTHERS
43 5/16"
V1
13' 1-9/16"
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
18 3/4"
V1
P3 P4
2 5/8"
P3
35 7/16" 35 7/16" 35 7/16" 25 9/16"
25 9/16"
LOAD "B"
3"
37 1/2"
E1
E2
E3
E4
E5
E6
E7
E8
E9
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS
REQUIRE 35" TO
BE REMOVED. EXTRA
CLEARANCE SHOULD BE
PROVIDED.
E
89 3/8"
TE (e)
35"
36 1/4"
40 3/8"
44 13/16"
see note (a)
BLOWER/
UNLOAD
END
22" HIGH X 29-13/16"
WIDE OPENING WILL
HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL
24" RECOMMENDED,
WITH DETERGENT DISPENSER
DRYER
FNL
RNS
AUX
RNS
POWER
RINSE
POWER
WASH
DIRECTION OF OPERATION
MODEL NO.
FT1021 (2-1/2'-13'-5-1/2')
FT1022 (3-1/2'-13'-5-1/2')
FT1023 (4-1/2'-13'-5-1/2')
FT1023 (2-1/2'-13'-7-1/2')
FT1024 (3-1/2'-13'-7-1/2')
FT1025 (4-1/2'-13'-7-1/2')
FT1025 (2-1/2'-13'-9')
FT1026 (3-1/2'-13'-9')
FT1027 (4-1/2'-13'-9')
FT1027 (2-1/2'-13'-11') 26' 10-7/8"
FT1028 (3-1/2'-13'-11') 27' 10-5/8"
FT1029 (4-1/2'-13'-11') 28' 10-15/32"
FT1030 (2-1/2'-13'-15')
FT1031 (3-1/2'-13'-15')
FT1032 (4-1/2'-13'-15')
FT1032 (2-1/2'-13'-17') 32' 5-3/4"
FT1033 (3-1/2'-13'-17') 33' 5-1/2"
FT1034 (4-1/2'-13'-17')
PRE-
WASH
ASR
"A" "B" "C"
21' 4"
22' 3-3/4" 3' 7-1/4"
23' 3-19/32" 4' 7-3/32"
23' 3-1/2" 2' 7-1/2" 7' 6-1/2"
24' 3-1/4" 3' 7-1/4"
25' 3-3/32" 4' 7-3/32" 7' 6-1/2"
24' 11-1/4" 2' 7-1/2" 9' 2-1/4"
25' 11"
26' 10-27/32" 4' 7-3/32" 9' 2-1/4"
30' 6-3/16" 2' 7-1/2" 14' 9-3/16"
31' 5-15/16" 3' 7-1/4" 14' 9-3/16"
32' 5-25/32" 4' 7-3/32" 14' 9-3/16"
34' 5-11/32" 4' 7-3/32" 16' 8-3/4"
LOAD
END
36 1/2"
6"
2' 7-1/2"
3' 7-1/4" 9' 2-1/4"
2' 7-1/2" 11' 1-7/8"
3' 7-1/4" 11' 1-7/8"
4' 7-3/32" 11' 1-7/8"
2' 7-1/2" 16' 8-3/4"
3' 7-1/4" 16' 8-3/4"
5' 7"
5' 7"
5' 7"
7' 6-1/2"
62 3/4"
SEE NO
(f)
Page 14 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
FT1000D ENERGY RECOVERY
SERVICE WIRE TEMPERATURE RATING: 90C.
Do not premix other chemicals and sodium
hypochlorite (liquid bleach).
Mixing may cause hazardous gas to form.
Electrical and grounding connection
must comply with the applicable portions
of the National Electrical Code and/or
other local electrical codes.
Plumbing connections must comply with
applicable sanitar
codes.
vary, some methods are shown on this drawing.
Pressure gauge not required on pumped rinse machines.
Important:
above floor
If chemical containers are to be placed in cabinet adjacent to machine,
a 1/2" dia. hole is required in the cabinet to run chemical supply line
Use only 6% or 8.4% sodium hypochlorite (liquid bleach) as sanitizing
chemical to insure proper operation of dishmachine
Certain materials including silver plat
ELECTRICAL CONNECTIONS
COMMON ON
E2 ELECTRIC CONNECTIO
(SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
W/O CIRCUIT BREAKERS:
E3
E7
1" CONDUIT. 79-1/8" AFF
1-1/4" CONDUIT, 79-1/8" AFF
D END OPTION IS SPECIFIED).
2" FPT. 7" AFF
VENTILATION REQUIREMENTS:
V1
95-3/8" AFF see note (f).
SERVICE CONNECTION W/O CIRCUIT BREAKERS
ELECTRIC TANK HEAT, BOOSTER
MODEL:
FT1000 ENERGY RECOVERY
(ASR
ELECTRIC
R-L OPERA
00-949506
REV A
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT
THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK
AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR
ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT.
FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT.
INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W
THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE
AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR
SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE
DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (45-50 PSI WHEN EQUIPPED WITH AUTOCLEAN
OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT
SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR
EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER
SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESSURE IS UNDER 15 PSI AT THE DISHWASHER, CONTAC
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES
(g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS
(h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS.
(j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
y, safety and plumbing
Drain and fill line configurations
Chemical containers should be placed no higher than 10"
.
by sodium hypochlorite (liquid bleach). See instructional
, ER, B/D)
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 15 of 20
TION
e, aluminum and pewter are
s
.
W/BLOWER DRYER, ELECTRIC R-L
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A
(MACHINE SERVICE VOLTAGE), 1/2" CONDUIT.
79-1/8" AFF
ELECTRIC CONNECTION, MOTORS & CONTROLS,
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, POWER RINSE TANK, 20 KW
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, WASH TA NK, 20 KW.
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, D UAL RINSE TANK, 10KW.
1" CONDUIT. 79-1/8" AFF
ELECTRIC TANK HEAT CONNECTION, B OOSTER, 18KW.
WITH CIRCUIT BREAKERS:
E8 ELECTRIC CONNECTION, MOTORS, CONTROLS, RINSE HEAT,
BOOSTER HEAT (WHEN CIRCUIT BREAKER OPTION IS SPECIFIED)
(TB1) 2" CONDUIT, 79-1/8" AFF
E9 ELECTRIC CONNECTION, WASH HEAT & DUAL RINSE HEAT (TB2)
COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER,
MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
AUTO CLEAN OPTION) 55°F WATER MINIMUM.
1" FPT, 1-1/2" AFF see notes (b) and (d).
COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED).
2" FPT. 7" AFF
COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA
MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA
PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
SERVICE CONNECTION WITH CIRCUIT BREAKERS
(2) SERVICE CONNECTIONS AS SHOWN BELOW
MOTORS, CONTROLS, POWER RINSE & BOOSTER HEAT(TB1)
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
(5) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE, B/D HEAT & BLOWERS
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
.
SPECS.
208/60/3
240/60/3
480/60/3
RATED
AMPS
156.3
144.9
72.4
WASH, DUAL RINSE HEAT(TB2)
RATED
AMPS
128.2 150 150
121.5 150 150
60.7 75 75
RATED
AMPS
62.1
58.5
29.3
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
200
175 175
90 90
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
80 80
70 70
35 35
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
N, VENT FAN CONTROL.
WATER CONNECTION (FINAL RINSE WITH OR W/O THE
ELECTRIC TANK HEAT, POWER RINSE
(1) 18KW CONNECTION AS SHOWN BELOW
MAXIMUM
PROTECTIVE
DEVICES
200
MAXIMUM
PROTECTIVE
DEVICE
MAXIMUM
PROTECTIVE
DEVICES
1/3 HP
1/4 HP
3 1/2 HP
5 HP
5 HP
1/6 HP
1/2 HP
1/3 HP
1/3 HP
ELEC.
SPECS.
208/60/3
240/60/3
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
ELEC.
SPECS.
208/60/3
240/60/3
(1) SERVICE CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
RATED
AMPS
(1) 22 KW CONNECTION AS SHOWN BELOW
RATED
AMPS
(1) 18 KW CONNECTION AS SHOWN BELOW
RATED
54.0 70 70
51.5 70 70
25.8 35 35
66.0 80 80
63.0 80 80
31.5 40 40
RATED
AMPS
54.07
51.57
AMPS
48.2 60 60
41.8 50 50
20.9 25 25
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
MAXIMUM
PROTECTIVE
DEVICES
0
0
MAXIMUM
PROTECTIVE
DEVICE
FT1000D ENERGY RECOVERY
Pressure gauge not required on pumped rinse machines.
Important:
above floor
If chemical containers are to be placed in cabinet adjacent to machine,
a 1/2" dia. hole is required in the cabinet to run chemical supply line
Use only 6% or 8.4% sodium hypochlorite (liquid bleach) as sanitizing
chemical to insure proper operation of dishmachine
Certain materials including silver plat
Do not premix other chemicals and sodium
hypochlorite (liquid bleach).
Mixing may cause hazardous gas to form.
W/BLOWER DRYER, STEAM L-R
P8
15 11/16"
P8
18 3/4"
37 1/2"
E1
E2
E3
V1
P4 P3
2 5/8"
P3
E3
P6
P7
68 13/16"
P8
9 15/16"
E2
E1
14 11/16"
5 15/16"
33 3/8"
2 15/16"
11 13/16"
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
55 3/16"
P2
51 15/16"
P4
44 9/16"
33"
P10
P10
6 3/4"
P8
23 1/8"
P6
V1
P9
28 7/16"
38 1/4"
11 9/16"
21 3/4"
23"
P7
P1
P9
23 3/4"
P2
P5
28 15/16"
55 11/16"
END
25 9/16"
3"
ASR
35"
LOAD "B"
LOAD
62 3/4"
TE
(f)
36 1/2"
6"
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS
REQUIRE 35" TO
BE REMOVED. EXTRA
CLEARANCE SHOULD BE
PROVIDED.
Page 16 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
E
13' 1-9/16"
35 7/16" 35 7/16" 35 7/16" 25 9/16"
5 3/4"
40 3/8"
44 13/16"
see note (a)
PRE-
WASH
DIRECTION OF OPERATION
22" HIGH X 29-13/16"
WIDE OPENING WILL
HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL
24" RECOMMENDED,
WITH DETERGENT DISPENSER
POWER
WASH
POWER
RINSE
UNLOAD "C"
EXHAUST HOOD
SUPPLIED BY OTHERS
43 5/16"
23 3/4"
6"
V1
BLOWER/
DRYER
AUX
FNL
RNS
RNS
UNLOAD
END
36 1/4"
Chemical containers should be placed no higher than 10"
.
by sodium hypochlorite (liquid bleach). See instructional
e, aluminum and pewter are
89 3/8"
SEE NOTE (e
.
.
FT1000D ENERGY RECOVERY
SERVICE WIRE TEMPERATURE RATING: 90C.
(j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
MODEL:
FT1000 ENERGY RECO
(ASR
STEA
L-R OPERA
00-949507
REV A
ELECTRICAL CONNECTIONS
COMMON ON
E2 ELECTRIC CONNECTIO
(SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
WITH &
D END OPTION IS SPECIFIED).
VENTILATION REQUIREMENTS:
95-3/8" AFF see note (f).
Electrical and grounding connection
must comply with the applicable portions
of the National Electrical Code and/or
other local electrical codes.
Plumbing connections must comply with
applicable sanitar
codes.
vary, some methods are shown on this drawing.
SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT
THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK
AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR
ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT.
FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT.
INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W
THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE
AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR
SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE
DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (45-50 PSI WHEN EQUIPPED WITH AUTOCLEAN
OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT
SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR
EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER
SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESSURE IS UNDER 15 PSI AT THE DISHWASHER, CONTAC
W/BLOWER DRYER, STEAM L-R
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A
(MACHINE SERVICE VOLTAGE), 1/2" CONDUIT.
79-1/8" AFF
W/O CIRCUIT BREAKERS:
ELECTRIC CONNECTION, MOTORS & CONTROLS
1" CONDUIT. 79-1/8" AFF
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER,
MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION (FINAL RINSE WITH OR W/O THE
AUTO CLEAN OPTION) 55°F WATER MINIMUM.
1" FPT, 1-1/2" AFF see notes (b) and (d).
P3 COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED).
2" FPT. 7" AFF
P4 COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA
2" FPT. 7" AFF
P5 COMMON STEAM CONNECTION (TANK HEAT).
1-1/2" FPT, 4-3/8" AFF (50 PSI MAX, 15-25 FLOWING PRESSURE) see note (e).
P7 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED)
1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 16-15/16" AFF
P8 HOT WATER RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED)
3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 15-9/16" AFF
P9 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT),
BUCKET TYPE TRAPS FURNISHED, 3 CONNECTIONS.
3/4" FPT, 11" AFF
P10 C ONDENSATE RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER OPTION
IS SPECIFIED), BUCKET TYPE TRAP FURNISHED.
3/4" FPT, 4-3/4" AFF
V1 MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA
PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
N, VENT FAN CONTROL.
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES
(g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS
(h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS.
MODEL NO.
FT1021 (2-1/2'-13'-5-1/2')
FT1022 (3-1/2'-13'-5-1/2')
FT1023 (4-1/2'-13'-5-1/2')
FT1023 (2-1/2'-13'-7-1/2')
FT1024 (3-1/2'-13'-7-1/2')
FT1025 (4-1/2'-13'-7-1/2')
FT1025 (2-1/2'-13'-9')
FT1026 (3-1/2'-13'-9')
FT1027 (4-1/2'-13'-9')
FT1027 (2-1/2'-13'-11') 26' 10-7/8"
FT1028 (3-1/2'-13'-11') 27' 10-5/8"
FT1029 (4-1/2'-13'-11') 28' 10-15/32"
FT1030 (2-1/2'-13'-15')
FT1031 (3-1/2'-13'-15')
FT1032 (4-1/2'-13'-15')
FT1032 (2-1/2'-13'-17') 32' 5-3/4"
FT1033 (3-1/2'-13'-17') 33' 5-1/2"
FT1034 (4-1/2'-13'-17')
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
, ER, B/D)
M
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 17 of 20
VERY
TION
"A" "B" "C"
2' 7-1/2"
3' 7-1/4" 9' 2-1/4"
2' 7-1/2" 11' 1-7/8"
3' 7-1/4" 11' 1-7/8"
4' 7-3/32" 11' 1-7/8"
2' 7-1/2" 16' 8-3/4"
3' 7-1/4" 16' 8-3/4"
21' 4"
22' 3-3/4" 3' 7-1/4"
23' 3-19/32" 4' 7-3/32"
23' 3-1/2" 2' 7-1/2" 7' 6-1/2"
24' 3-1/4" 3' 7-1/4"
25' 3-3/32" 4' 7-3/32" 7' 6-1/2"
24' 11-1/4" 2' 7-1/2" 9' 2-1/4"
25' 11"
26' 10-27/32" 4' 7-3/32" 9' 2-1/4"
30' 6-3/16" 2' 7-1/2" 14' 9-3/16"
31' 5-15/16" 3' 7-1/4" 14' 9-3/16"
32' 5-25/32" 4' 7-3/32" 14' 9-3/16"
34' 5-11/32" 4' 7-3/32" 16' 8-3/4"
5' 7"
5' 7"
5' 7"
7' 6-1/2"
Drain and fill line configurations
y, safety and plumbing
(1) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE
(1) 10 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
RATED
AMPS
57.8
50.2
25.1
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
70 70
60 60
30 30
1/3 HP
1/4 HP
3 1/2 HP
5 HP
5 HP
1/6 HP
1/2 HP
1/3 HP
1/3 HP
s
MAXIMUM
PROTECTIVE
DEVICES
FT1000D ENERGY RECOVERY
Pressure gauge not required on pumped rinse machines.
Important:
above floor
If chemical containers are to be placed in cabinet adjacent to machine,
a 1/2" dia. hole is required in the cabinet to run chemical supply line
Use only 6% or 8.4% sodium hypochlorite (liquid bleach) as sanitizing
chemical to insure proper operation of dishmachine
Certain materials including silver plat
Do not premix other chemicals and sodium
hypochlorite (liquid bleach).
Mixing may cause hazardous gas to form.
FLOOR LINE
7 3/16"
3 15/16"
W/BLOWER DRYER, STEAM R-L
P2
P1
P4
32 15/16"
14 5/8"
5 7/8"
V1
11 13/16"
55 11/16"
52"
44 9/16"
P7
P10
P2
P5
P1
23 3/4"
P9
23 1/16"
28 15/16"
6 3/4"
P9
P5
28 7/16"
38 1/4"
11 5/8"
P6
23 1/8"
P6
P7
53 3/8"
22 5/8"
9 15/16"
P10
E1
88 3/4"
P8
E2
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
P8
E3
P8
15 11/16"
P8
18 3/4"
V1
P3 P4
2 5/8"
P3
37 1/2"
E1
E2
E3
V1
89 3/8"
TE (e)
36 1/4"
Page 18 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher
EDITION OF NATIONAL
ELECTRICAL CODE AND
LOCAL BUILDING CODES
FOR PROPER CLEARANCE
NOTE: STRAINER PANS
REQUIRE 35" TO
BE REMOVED. EXTRA
CLEARANCE SHOULD BE
PROVIDED.
35"
E
40 3/8"
44 13/16"
see note (a)
UNLOAD
END
UNLOAD "C"
EXHAUST HOOD
SUPPLIED BY
OTHERS
43 5/16"
BLOWER/
DRYER
22" HIGH X 29-13/16"
WIDE OPENING WILL
HANDLE 18" X 26" BUN PANS
NOTE: CLEARANCE FROM WALL
24" RECOMMENDED,
WITH DETERGENT DISPENSER
23 3/4"
6"
FNL
RNS
AUX
RNS
5 3/4"
POWER
RINSE
POWER
WASH
DIRECTION OF OPERATION
Chemical containers should be placed no higher than 10"
.
by sodium hypochlorite (liquid bleach). See instructional
PRE-
WASH
35 7/16" 35 7/16" 35 7/16" 25 9/16"
25 9/16"
ASR
e, aluminum and pewter are
LOAD "B"
3"
LOAD
END
.
6"
36 1/2"
.
62 3/4"
SEE NO
(f)
FT1000D ENERGY RECOVERY
SERVICE WIRE TEMPERATURE RATING: 90C.
(j) BACK DRAFT PREVENTER RECOMMENDED (REQUIRED ON MACHINES EQUIPPED WITH ER)
MODEL:
FT1000 ENERGY RECO
(ASR
STEA
R-L OPERA
00-949506
REV A
ELECTRICAL CONNECTIONS
COMMON ON
E2 ELECTRIC CONNECTIO
(SWITCH CONTACTS) 1/2" CONDUIT. 79-1/8" AFF
ELECTRICAL CONNECTIONS
WITH &
D END OPTION IS SPECIFIED).
VENTILATION REQUIREMENTS:
95-3/8" AFF see note (f).
Electrical and grounding connection
must comply with the applicable portions
of the National Electrical Code and/or
other local electrical codes.
Plumbing connections must comply with
applicable sanitar
codes.
vary, some methods are shown on this drawing.
SERVICE CONNECTION WITH & W/O CIRCUIT BREAKERS
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
a) THE CONTROL BOX IS ATTA CHED TO THE CENTER SECTION, AND
BOX IS ROTATED 90 DEGREES ALLOWING THE CENTER SECTION TO FIT
THROUGH A 42" WIDE, 7' DOOR OPENING.
WITH BACK PANEL AND END CAPS REMOVED, CONTROL PANEL HINGED BACK
AND ALL REAR PIPING REMOVED, OVERALL WIDTH OF MACHINE IS 40".
AFF = ABOVE FINISHED FLOOR
ALL DIMENSIONS TAKE FROM THE FLOOR LINE MAY INCREASE 3-1/4" WITH
LEG ADJUSTMENT.
FOR CONVENIENCE WHEN CLEANING, CUSTOMER SHOULD INSTALL WATER
TAP NEAR MACHINE WITH 30 FT. OF HEAVY DUTY HOSE WITH SQUEEZE VALVE.
THIS DRAWING IS SUPPLIED AS A REFERENCE FOR CONNECTION INFORMA
ONLY. IT WILL NOT BE UTILIZED FOR MANUFACTURING OF UNIT.
INSULATED TOP COVER TOP COVER PANELS CAN BE TEMPORARILY REMOVED
FROM THE PRE-WASH, WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4"
LECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY W
THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE
AND/OR OTHER ELECTRICAL CODES.
PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITAR
SAFETY AND PLUMBING CODES.
RECOMMENDED WATER HARDNESS TO BE 3 GRAINS OR LESS PER
GALLON FOR BEST RESULTS.
RECOMMENDED BUILDING FLOWING HOT WATER PRESSURE TO THE
DISHWASHER IS 30-35 PSI.
c) RECOMMENDED BUILDING FLOWING COLD WATER PRESSURE TO THE
DISHWASHER IS 20 PSI (45-50 PSI WHEN EQUIPPED WITH AUTOCLEAN
OPTION IS SPECIFIED). IF COLD WATER IS LESS THAN 55°F CONTACT
SALES ENGINEERING.
WATER HAMMER ARRESTOR (MEETING ASSE-1010 STANDARD OR
EQUIVALENT) TO BE SUPPLIED (BY OTHERS) IN FINAL RINSE WATER
SUPPLY LINE AT SERVICE CONNECTION.
e) IF STEAM PRESSURE IS UNDER 15 PSI AT THE DISHWASHER, CONTAC
W/BLOWER DRYER, STEAM R-L
ALL MODELS:
ELECTRIC CONNECTION, DETERGENT A
(MACHINE SERVICE VOLTAGE), 1/2" CONDUIT.
79-1/8" AFF
W/O CIRCUIT BREAKERS:
ELECTRIC CONNECTION, MOTORS & CONTROLS
1" CONDUIT. 79-1/8" AFF
P1 COMMON HOT WATER CONNECTION (AUTOMATIC FILL) 140°F WATER,
MINIMUM, 1" FPT, 5-1/2" AFF see notes (b) AND (d).
P2 COMMON COLD WATER CONNECTION (FINAL RINSE WITH OR W/O THE
AUTO CLEAN OPTION) 55°F WATER MINIMUM.
1" FPT, 1-1/2" AFF see notes (b) and (d).
P3 COMMON DRAIN CONNECTION, (WHEN DRAIN TO LOAD END IS SPECIFIED).
2" FPT. 7" AFF
P4 COMMON DRAIN CONNECTION, (WHEN DRAIN TO UNLOA
2" FPT. 7" AFF
P5 COMMON STEAM CONNECTION (TANK HEAT).
1-1/2" FPT, 4-3/8" AFF (50 PSI MAX, 15-25 FLOWING PRESSURE) see note (e).
P7 STEAM RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED)
1" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 16-15/16" AFF
P8 HOT WATER RELIEF VALVE, (WHEN STEAM BOOSTER OPTION IS SPECIFIED)
3/4" FPT, MUST BE PIPED TO OPEN DRAIN RECEIVER IN THE FLOOR. 15-9/16" AFF
P9 CONDENSATE RETURN, GRAVITY CONNECTION (TANK HEAT),
BUCKET TYPE TRAPS FURNISHED, 3 CONNECTIONS.
3/4" FPT, 11" AFF
P10 C ONDENSATE RETURN, GRAVITY CONNECTION (WHEN STEAM BOOSTER OPTION
IS SPECIFIED), BUCKET TYPE TRAP FURNISHED.
3/4" FPT, 4-3/4" AFF
V1 MINIMUM OF 24" SQUARE VENT HOOD (SUPPLIED BY OTHERS) CAPA
PROVIDING 706 CFM EXHAUST (AT STANDARD AIR CONDITIONS).
N, VENT FAN CONTROL.
(f) THIS DIMENSION IS SUBJECT TO NORMAL SHEET METAL TOLERANCES
(g) THE VENT STACK AND ITS ENCLOSURE CAN BE TEMPORARILY REMOVED FROM
THE ENERGY RECOVERY UNIT TO YIELD 81-78" CLEARANCE FOR DOORWAYS
(h) THE INSULATED TOP COVER PANELS CAN BE TEMPORARILY REMOVED FROM THE PREWA
WASH OR POWER RINSE SECTIONS TO YIELD 61-3/4" CLEARANCE FOR DOORWAYS.
MODEL NO.
FT1021 (2-1/2'-13'-5-1/2')
FT1022 (3-1/2'-13'-5-1/2')
FT1023 (4-1/2'-13'-5-1/2')
FT1023 (2-1/2'-13'-7-1/2')
FT1024 (3-1/2'-13'-7-1/2')
FT1025 (4-1/2'-13'-7-1/2')
FT1025 (2-1/2'-13'-9')
FT1026 (3-1/2'-13'-9')
FT1027 (4-1/2'-13'-9')
FT1027 (2-1/2'-13'-11') 26' 10-7/8"
FT1028 (3-1/2'-13'-11') 27' 10-5/8"
FT1029 (4-1/2'-13'-11') 28' 10-15/32"
FT1030 (2-1/2'-13'-15')
FT1031 (3-1/2'-13'-15')
FT1032 (4-1/2'-13'-15')
FT1032 (2-1/2'-13'-17') 32' 5-3/4"
FT1033 (3-1/2'-13'-17') 33' 5-1/2"
FT1034 (4-1/2'-13'-17')
TE: OVERALL LENGTH OF MACHINE IS DIMENSION "A" + 11 3/4"
, ER, B/D)
M
F40351 – FT1000D Energy Recovery Flight-Type Dishwasher Page 19 of 20
VERY
TION
"A" "B" "C"
2' 7-1/2"
3' 7-1/4" 9' 2-1/4"
2' 7-1/2" 11' 1-7/8"
3' 7-1/4" 11' 1-7/8"
4' 7-3/32" 11' 1-7/8"
2' 7-1/2" 16' 8-3/4"
3' 7-1/4" 16' 8-3/4"
21' 4"
22' 3-3/4" 3' 7-1/4"
23' 3-19/32" 4' 7-3/32"
23' 3-1/2" 2' 7-1/2" 7' 6-1/2"
24' 3-1/4" 3' 7-1/4"
25' 3-3/32" 4' 7-3/32" 7' 6-1/2"
24' 11-1/4" 2' 7-1/2" 9' 2-1/4"
25' 11"
26' 10-27/32" 4' 7-3/32" 9' 2-1/4"
30' 6-3/16" 2' 7-1/2" 14' 9-3/16"
31' 5-15/16" 3' 7-1/4" 14' 9-3/16"
32' 5-25/32" 4' 7-3/32" 14' 9-3/16"
34' 5-11/32" 4' 7-3/32" 16' 8-3/4"
5' 7"
5' 7"
5' 7"
7' 6-1/2"
Drain and fill line configurations
y, safety and plumbing
(1) SERVICE CONNECTIONS AS SHOWN BELOW
ELECTRIC TANK HEAT, DUAL RINSE
(1) 10 KW CONNECTION AS SHOWN BELOW
ELEC.
SPECS.
208/60/3
240/60/3
480/60/3
RATED
AMPS
57.8
50.2
25.1
ASR PUMP
ASR SOIL
PREWASH
WASH
POWER RINSE
DUAL RINSE
PUMPED RINSE
EXHAUST
CONVEYOR
MINIMUM
SUPPLY
CONDUCTOR
AMPACITY
70 70
60 60
30 30
1/3 HP
1/4 HP
3 1/2 HP
5 HP
5 HP
1/6 HP
1/2 HP
1/3 HP
1/3 HP
s
MAXIMUM
PROTECTIVE
DEVICES
FT1000D ENERGY RECOVERY
FLIGHT-TYPE DISHWASHER
FT (ight type) Models—many additional variations of
these model specications are available. Engineering
data furnished on request. Numbers in parentheses,
after model number from left to right, represent length
in feet of the following respectively; Loading section,
Washing and Power Rinsing sections, Unloading
section.
Flight-type dishwasher with BLOWER-DRYER has
the same specications as the Basic FT1000 Series
EXCEPT for one additional Blower Motor (2 H.P. —
208-240/60/3 and 480/60/3) and is available on any
model having either a 5* (without blower dryer), 7, 9,
11 or 13 foot unloading section.
Entire FT1000 Series is listed by UL and NSF and
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
meets requirements of ASSE Standard No. 1004.
FT1000 Series
(7, 9, 11 Load / 8 Center / 5*, 7, 9, 11, 13 Unload)
Machine Ratings (Mechanical)
Conveyor Speed — Feet per minute 6.5 - 8.5
Dishes per Hour 14,316
Overall Dimensions (H x W) — inches (standard height) 80 11⁄16 (C) x 47 (B)
Motor — Horsepower ASR Soil - 1⁄4 ; ASR Wash - 1⁄3 ; Pre-Wash - 3; Wash - 5; Rinse - 5;
Tank Capacity — Gallons ASR - 5.6; Pre-Wash - 40; Wash - 40; Rinse - 40; Dual Rinse - 5.6
Pump Capacity
Gallons per minute—Weir Test Pre-Wash - 150; Wash - 292; Rinse - 292
Final Rinse — Minutes of operation during
one hour of continuous operation 60 at continuous loading condition
Rate of Final Rinse — Gallons per minute
at 20 PSI ow pressure .98
Final Rinse Consumption — Gallons per hour
at 20 PSI ow pressure 58
Exhaust Requirements — Cubic feet per minute
with Blower Dryer
Electric Heat Requirements —
Tank Heat - Kilowatt (Regulated)
Optional Electric Booster - Kilowatt
Optional Blower Dryer — Kilowatt 7.5 KW (functions only during conveyor operation)
Steam Heat Requirements —
Steam Consumption
Tank Heat - Pounds per hour - maximum
(Regulated) - based on 15 to 52 PSI steam at
the machine and on the customer supplying
nal rinse water at minimum (A) (20 PSIG)
Optional Steam Booster - Pounds per hour - maximum
- based on 20 PSI steam at 20 PSI water owing 120°F incoming water raised to 190°F (70°F rise)
(180°F minimum)
Peak Rate of Drain Flow — Gallons per minute
Initial rate with full tanks 38
Shipping Weight Crated Varies by individual model - consult your Hobart representative
Disconnect switches are recommended for each power circuit connected
to dishwasher. These disconnect switches are NOT furnished by Hobart
and should be installed by the electrical contractor at the time of installation.
18KW - 110°F incoming water raised to 190°F (85°F rise) (180°F minimum)
(A) If only 10-12 PSIG Steam Pressure available at machine - specify Low Pressure Steam Option.
(B) With all rear panels and plumbing removed, machine width is 391⁄8 ".
(C) Highest item is control box - 8011⁄16 ". Can be adjusted lower 2" for door clearance.
* 5 ft. unload available without blower dryer.
Conveyor - 1⁄3 ; Dual Rinse - 1⁄6 ; Final Rinse - 1⁄2
750
(at standard air conditions)
Circuit breakers optional at extra cost.
Total tank heat - 50KW (Wash, Rinse, Dual Rinse)
24 kw - 140° Incoming Water
Approximately 30 lbs. per hour = 1 boiler H.P. (BHP)
175 lbs./150°F Wash minimum/160°F Rinse minimum
99 lbs.
As continued product improvement is a policy of Hobart, specications are subject to change without notice.
Page 20 of 20 F40351 – FT1000D Energy Recovery Flight-Type Dishwasher