Hobart 1HG85CF General Manual

Item # _____________________________________
Quantity ___________________________________
C.S.I. Section 11400
1HG85CF WITH KLEENSCREEN
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
STANDARD FEATURES
Computer control with digital character display. Completely programmable with 10 menu driven product keys. Adjusts from 200° to 390°F. User selectable melt modes. Automatic boil out modes. Programmable Celsius and Fahrenheit temperature scales.
Boil Out ByPass™ for easy removal of boil out solution.
Drain valve interlock switch – shuts burners off automatically when ltering or discarding shortening.
6" casters adjustable – 2 locking, 2 non-locking.
Electronic ignition on computer control fryers.
Drawn (seamless) 18 gauge, stainless steel lter
pan. 100 lbs. capacity. Dishwasher safe.
Paperless stainless steel lter screen lters from both sides = 462 sq. inches. Complimentary 3 pack of micro ltration fabric envelopes lter area = 515 sq. inches.
1⁄3 H.P. motor and pump circulates frying compound at a rate of 8.0 gallons per minute.
Patented solenoid activated one touch push button switch to engage pump motor.
High temperature discard hose for ushing and discarding shortening.
■ 1⁄2" I.D. 3⁄4" O.D. rear gas connection.
11⁄4" full port drain valve.
Primary crumb catch basket.
Tank brush, stainless steel crumb scoop and
clean-out rod.
120 volt, 50/60 Hz, 1 phase.
One year limited parts and labor warranty.
10 years limited fry tank warranty.
PLUS® FILTRATION SYSTEM
MODEL
1HG85CF with KleenScreen PLUS® Filtration
System – Built-in lter system for 1HG85CF Series Fryer
ACCESSORIES
Stainless steel tank cover doubles as a work top.
Micro-ltration fabric envelopes – 6 lters/per
package
“Add-On” Frymate™ VX21S – eld installed.
Twin basket lifts – factory installed
Single basket lifts – factory installed
Extra set of twin baskets
Single basket
10" stainless steel removable splash guard –
eld installed
Flexible gas hose with quick disconnect.
Specications, Details and Dimensions on Reverse Side.
1HG85CF WITH KLEENSCREEN PLUS
FILTRATION SYSTEM
SPECIFY TYPE OF GAS
Natural Gas
Propane Gas
SPECIFY ALTITUDE
Natural Gas above 2,000 ft.
Propane Gas above 3,000 ft.
F-40282 – 1HG85CF with KleenScreen PLUS® Filtration System Page 1 of 2
1HG85CF WITH KLEENSCREEN
E1
PLUS® FILTRATION SYSTEM
SPECIFICATIONS
85-90 lbs. capacity gas fryer, Hobart Model No. 1HG85CF. Stainless steel cabinet. Set of four 6" adjustable casters 2 locking, 2 non-locking. Stainless steel fry tank with ve heat exchanger tubes with a large "V" shaped cold zone. 11⁄4" full port ball type drain valve. Twin fry baskets with plastic coated handles. 150,000 BTU/hr. input. Computer control with digital character display. Completely programmable with 10 menu driven product keys. Adjusts from 200° to 390°F. User select­able melt modes. Automatic boil out modes. Programmable Celsius and Fahrenheit temperature scales. Patented Built-in KleenScreen PLUS® lter system, that accommodates one 85 lb. fryer. Filter pan is constructed of 18 gauge stainless steel.
1
3 H.P. motor/pump circulates hot frying compound at the rate of 8 gallons per minute, activated by a patented “hands free” solenoid push button. Each lter comes standard with paperless stainless steel mesh lter screen plus a complimen­tary package of KleenScreen PLUS® Micro-Filtration Fabric Envelopes. 1HG85CF comes on casters with a high tempera­ture discard/ush hose, primary crumb catch basket, tank brush, scoop and clean-out rod. Drain valve interlock switch turns fryer's burners off when drain valve is opened. Standard with tank brush, stainless steel crumb scoop and clean-out rod. Requires 120 volt, 50/60 Hz, 1 phase power supply. CSA design certied. NSF Listed.
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
IM P O RTANT
1. A combination valve with pressure regulator is provided with this unit.
Natural Gas 4.0" (102 mm) W.C. Propane Gas 10.0" (254 mm) W.C.
2. An adequate ventilation system is required for Commercial Cooking Equipment. Information may be obtained by writing to the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. When writing refer to NFPA No. 96.
3. All models require a 6" (152 mm) clearance at both sides and rear adjacent to combustible construction.
4. All models require a 16" (407 mm) minimum clearance to adjacent open top burner units.
5. This appliance is manufactured for commercial installation only and is not intended for home use.
SERVICE CONNECTIONS:
P1 1⁄2 " I.D. 3⁄4" O.D (12.7/19.0 mm ) NPT common rear gas
connection.
E1 120 volt, 60 Hz, 1 phase electrical connection (lter
pump).
DETAILS AND DIMENSIONS
Front View
1HG85CF Series
MODEL
1HG85CF 100 lbs.
FILTER PAN
CAPACITY
As continued product improvement is a policy of Hobart, specications are subject to change without notice.
Side View
1HG85CF Series
FILTER AREA
SCREEN/
FABRIC ENVELOPE
462 sq. in. 515 sq. in.
MOTOR PUMP
1
3 H. P.
1750 RPM
8 gal./min.
Top View
1HG85CF Series
ELECTRIC/
AMPS
115 V
5.0A
ELECTRIC
POWER
115 V
50/60 Hz
1 Ph
Page 2 of 2 F-40282 – 1HG85CF with KleenScreen PLUS® Filtration System
F-40282 (03/10) LITHO IN U.S.A. (H-01)
Loading...