Heat & Glo Heat-Out Installation & Operation Instructions -

0 (0)
Heat & Glo Heat-Out Installation & Operation Instructions -

Heat-Out Air Kit

- Installation & Operation Instructions -

INTRODUCTION

The HEAT-OUT accessory kit expels warm air from the fireplace to the outside of the building. This will allow the fireplace to be operated with less heat entering the room.

PRELIMINARY PREPARATION

1. Contents of kit: (See Figures)

DESCRIPTION

SERVICE PART NO.

 

 

Fall/Exterior Wall Assembly

660-100A

 

 

Damper Plate

660-133

 

 

Interior Firestop

660-140

 

 

Rear Collar

660-131

 

 

Fan Junction Box

660-137

 

 

Exterior Cap

660-135A

 

 

Hardware Bag

660-900A

 

 

On/Off Switch

130-511

 

 

1/2 oz Tube of Silicone

418-400

 

 

If any parts are missing or damaged, contact your Dealer before starting installation. DO NOT install a damaged kit. Be sure to also reference the fireplace Installer's Guide.

2.This kit is tested and safe when installed in accordance with this installation manual. It is your responsibility to read all instructions before starting installation and to follow these instructions carefully during installation.

3.Installation of this kit MUST be performed by a qualified service technician.

4.The HEAT-OUT kit is carefully engineered and must be installed only as specified. If you modify it or any of its components you will void the warranty, and you may possibly cause a fire hazard. Installation must be done according to applicable local, state, provincial, and/or national codes.

5.CAUTION: All wiring should be done by a qualified electrician and shall be in compliance with local codes and with the National Electric Code ANSI/NFPA No. 70current (In the United States), or with the current CSC22.1 Canadian Electric Code (in Canada).

6.Plan the location of the fireplace. If the vent system is going to be a horizontal termination off the top of the fireplace, the HEAT-OUT kit MUST be installed before the fireplace horizontal vent system/termination.

NOTE: The HEAT-OUT kit CANNOT be used if the fireplace is placed in a 45 - degree corner installation. The back of the fireplace MUST be positioned against an outside wall.

7. The bottom of the exterior cap MUST be a MINIMUM of 12 - in. (305 mm) above finished grade. Plan the location of the fireplace accordingly.

INSTALLATION

Install the Heat-Out kit following instructions in the fireplace Installer's Guide.

WIRING

1.Install the wall switch (provided in the kit) at a convenient location. This switch will control the HEAT - OUT fan. A variable speed type switch must NOT be used.

2.Wire 110 VAC service TO the wall switch and FROM the wall switch to the fan junction box. Use wire nuts to secure the 110VAC service wires to the hot and neutral fan wires and screw the 110VAC ground wire to the junction box. See Wiring Diagram - Figure 1.

3.Screw the fan junction box to the fan housing. See Figure 1.

Printed in U.S.A. Copyright 2003

 

Hearth & Home Technologies Inc., 20802 Kensington Boulevard, Lakeville, MN 55044

660-900D 3/03