Harman Stove Company XL User Manual

Page 1
ShadowLight XL
Direct Vent Gas Fireplace Insert
Owners Manual
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
FOR YOUR SAFETY: WHAT TO DO IF YOU SMELL GAS
• Do not touch electrical switches.
• Do not try to light any appliance.
• Open windows.
• Extinguish any open flame.
• Do not use the phone in your building.
• Immediately call your gas supplier from a neighbor's phone.
• Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
R2
8/06
ADVETISSEMENT: Quinconque ne respect pas à la lettre les instructions dans le présent manuel risque de déclencher un incendie ou une explosion entraíant des dommages matérials, des lésions corporelles ou la perte de vies humaines.
L’installation et service doit être exécuté par un qualifié installer, agence de service ou le fourmisseur de gaz.
Ne pas entreposer ni utiliser d'essence ni d'autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones se trouvant dans le batiment où vous trouvez.
• Evacuez la pièce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, ap­pelez le service dos incendies.
Tested by Intertek Testing Services/Warnock Hersey; 8431 Murphy Drive, Middleton, WI 53562
Part #3-90-00395
Page 2
2
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Installation and service must be performed by a qualified installer, service agency, or the gas sup­plier.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type(s) of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
ADVETISSEMENT: Quinconque ne respect pas à la lettre les instructions dans le présent manuel risque de déclencher un incendie ou une explosion entraíant des dommages matérials, des lésions corporelles ou la perte de vies humaines.
L’installation et service doit être exécuté par un qualifié installer, agence de service ou le fourmis­seur de gaz.
Ne pas entreposer ni utiliser d'essence ni d'autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
Cet appareil peut être installé dans un maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
Cet appareil doit être utilisé uniquement avec les types de gas indiqués sur la plaque signalétique. Ne pas l’utiliser avec d’autres gas sauf si un kitde conversion cerifié est installé.
“In the Commonwealth of Massachusetts, this product must be installed by a licensed Massachusetts Plumber or Gas Fitter”
IMPORTANT
The Shadowlight XL is manufactured and shipped set up for LP gas (Propane). Conversion kits (page 14) are available to convert to natural gas or back to LP gas.
It is important to mark the fuel label accordingly so that the value is easily identified as to which fuel it is set up for.
Manufactured by:
Harman Stove Co.
352 Mountain House Road
Halifax, PA 17032
Page 3
TABLE OF CONTENTS
INTRODUCTION ...........................................................4
SPECIFICATIONS ......................................................... 5
OPERATION ...................................................................8
How to Light the Fire ................................................ 9
How to Turn Off the Fire ......................................... 10
INSTALLATION ........................................................... 11
Clearances ...............................................................12
Connecting to a Gas Supply .................................... 13
Converting to Natural Gas .......................................15
Converting to High Altitude .................................... 17
Venting .....................................................................18
Installing into a Fireplace ........................................20
Options ....................................................................24
3
MAINTENANCE .......................................................... 25
Removing the Glass .................................................25
Replacing the Gasket ............................................... 25
Cleaning the Glass ................................................... 25
Cleaning the Log Set and Firebox ........................... 25
Convection Blower Service Access.................. .......26
WIRING DIAGRAM .....................................................27
PARTS LIST ....................................... ......................... 28
TROUBLE SHOOTING ................................................30
WARRANTY .................................................................34
Page 4
4
Introduction
The installation of the ShadowLight XL Fireplace Insert must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z233.1 (NFPA
54). Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les Codes d'installation CAN/CGA-B149.
The ShadowLight XL Fireplace Insert may be installed in mobile homes.
CAUTION: This appliance must be vented to the outside.
Installation and repair of the ShadowLight XL Fireplace Insert should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean. Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.
S'ASSURER QUE LE BRÛLEUR ET LE COMPARTIMENT DES COMMANDES SONT PROPRES. VOIR LES INSTRUCTIONS D'INSTALLATION ET D'UTILISATION QUI ACCOMPAGNENT L'APPAREIL.
When operating your Harman ShadowLight XL Fireplace Insert, respect basic safety standards.
Read these instructions carefully before you attempt to operate the heater. Failure to do so may result in damage to property or personal injury and may void the product warranty.
Consult with your local building code agency and insurance representative before you begin your installation to ensure compliance with local codes, including the need for permits and follow-up inspections.
Observing required clearances to combustible materials, proper connection to an approved venting system, and the accessibility of the gas and electrical supply must all be considered when planning the installation of a ShadowLight XL Fireplace Insert.
Install the ShadowLight XL Fireplace Insert only in a listed solid-fuel burning factory-built fireplace or a masonry solid-fuel burning fireplace. The Fireplace
Insert and vent should be enclosed when installed in, or when passing through, a living area where children may come in contact with it.Z21.88-2002-CSA 2.33­2002,CAN/CGA2.17.
Listed Direct Vent Gas Fireplace Heater
Radiateur Ventile
Model: ShadowLight XL Gas Fireplace Insert
WHI #
• Not for use with solid fuel. Not for use with air filters. Ne doit pas etre utilise avec un combustible solide.
• Also for use in mobile (manufactured) homes after home is sited.
• Tested to ANSI Z21.88-2002 / CSA2.33-2002 / CAN-CGA-2.17-M91
• For use with natural gas or propane. A conversion kit, as supplied by the manufacturer, shall be used to convert this room heater to the alternate fuel. Pour utilisation, avec le gaz naturel et le propane. Une trousse de
conversion fournie par le fabricant doit etre utilisee pour passer d’un combustible a l’autre.
• Keep burner and control compartment clean. See installation and operating instructions accompanying appliance. S’assurer que le bruleur et le compartiment des commandes sont propres. Voir les instructions d’installation et d’utilisation qui accompagnent l’appareil.
During repairs or maintenance of this unit, all sealing gaskets or high temperature silicone seals on the heat exchanger module must be in­spected for damage and replaced, if necessary, to prevent any leakage of exhaust into the living areas.
Electrical Rating: 115 VAC, 60 Hz, < 1.15 AMP
RATINGS
Input Rating(Btu/hr)(0-2000 ft)(0-610m) Input Rating(Btu/hr)(2000-4500ft)(610-1375m) Min. Input Rating(Btu/hr) Orifices (DMS)(0-2000 ft)(0-610m) Orifices (DMS)(2000-4500ft)(610-1375m) Manifold Pressure (in w.c./kPa) Min. Manifold Pressure (in w.c./kPa) Min. Inlet Pressure (in w.c./kPa)
MANTEL CLEARANCE: Combustible mantle up to 8” in depth must be at least 43” above unit base. CAUTION: Do not operate the appliance with glass removed, cracked or broken. Replacement of panel(s) should be done by a licensed or qualified service person. CAUTIONNER: N’orére l’appareil avec le verre enlevé, craque ou casse. Le remplacement du panneau(s) devrait être fait par une personne de service qualifie ou autorise.
CAUTION: Hot while in operation. Do not touch. Severe burns may result. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away. ATTENTION: Les surfaces sont chaudes en service. Ne touchez pas. Risque de brulure grave. Tenez les enfants, les vatements, le mobilier, l’essence et autres liquides produisant des vapeurs inflammables B distance.
This appliance is only for use with the type of gas indicated on the rat­ing plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner’s manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used.
A LABEL (LOCATED NEAR THE BURNER SYSTEM MOD­ULE) STATES THE FUEL FOR WHICH THE HEATER IS EQUIPPED.
Manufactured by Harman Stove Company 352 Mountain House Road, Halifax, PA 17032 20 Airport Road, West Lebanon, NH 03784
• Homologue Pour Le Canada
• Do not remove this label.
NATURAL 35,000 34,000 21,600 31 33
3.5/.87
1.3/.32
5.0/1.24
PROPANE 35,000 34,500 20,900 50 51
2.5
3.6/.9
11.0/2.75
SAFETY LABEL
Page 5
30”
40”
Front View
Minimum Opening Size: 29”
Inlet
Outlet
Specifications
5
14”
Top View
13”
Side View
Front View
Page 6
Specifications
6
On-Off- Thermostat Switch
Glass Door
Face Bolt
Burner
Lighting Instructions
Igniter
Blower Speed Switch
Pilot
Burner Plate
Face Bolt
Leveling Bolt
Hi-Low Knob
Latch Handle
On-Off-Pilot Knob
Safety Label
Leveling Bolt
Page 7
Vent
7
Air Intake
Specifications
On-Off Thermostat Switch
On-Off Thermostat Switch Connector
Leveling Bolt
RATINGS NATURAL PROPANE
Input Rating (Btu/hr)(0-2,000 ft)(0-610m) 35,000 BTU 35,000 BTU
Input Rating(Btu/hr)(2000-4500ft)(610-1375m) 34,000 BTU 34,500 BTU
Min. Input Rating (Btu/hr) 21,600 BTU 20,900 BTU
Orifices (DMS)(0-2000 ft)(0-610m) 31 50
Orifices (DMS)(2000-4500ft)(610-1375m) 33 51
Manifold Pressure (in w.c./kPa) 3.5 / .87 10.0 / 2.49
Minimum Manifold Pressure (in w.c./kPa) 1.3 / .32 3.6 / 0.9
Minimum Inlet Pressure (in w.c./kPa) 5.0 / 1.25 11.0 / 2.74
Maximum Output (BTU/hr)(0 to 4,500 ft.)(0 to 1,375 m)(Blower off) 27,600 28,600
Page 8
8
Operation
Warning
Doors Are Hot While In Operation. Wear Gloves
and Only Touch Doors On The Handles.
Door Handles
PILOT
Pilot Location Shown Above
Blower Speed Switch
Lift bottom grill with index finger and fold down to access controls
Pull lighting instruction
Piezo Igniter Button
plate out to view text.
Push back in before
closing grills.
ON-OFF/ THERMOSTAT Switch
ON
OFF
THERMOSTAT
UP - ON MIDDLE - OFF DOWN - THERMOSTAT
Page 9
Operation
Operation
HOW TO LIGHT THE FIRE
1. STOP! Read the safety information on the front cover.
9
High-Low
2. If using the optional thermostat, set thermostat to the lowest setting.
3. Turn off electric power to the appliance.
4. Turn the ON-OFF/THERMOSTAT switch to the OFF position.
5. Push in the gas control knob slightly and turn it clockwise to “OFF.” NOTE: THE KNOB CANNOT BE TURNED FROM “PILOT” TO “OFF” UNLESS IT IS PUSHED IN SLIGHTLY. DO NOT FORCE IT.
6. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow instructions on the front cover. If you don’t smell gas, go to the next step.
7. Set the High-Low Regulator to High by turning it fully counterclockwise.
8. Press in the gas control knob slightly and turn coun­terclockwise to “PILOT.”
9. Find the pilot by looking at the location shown in the picture on page 8.
10. Push the control knob fully down and hold. Im­mediately push the red piezo ignitor button to light the pilot. It is normal to have to push the red button several times before the pilot ignites. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release the knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9.
A LABEL ON THE BURNER SYSTEM MOD­ULE STATES THE FUEL FOR WHICH THE HEATER IS EQUIPPED. It is not marked at the factory since it can be converted.
DURING INSTALLATION THIS LABEL MUST BE MARKED FOR THE TYPE OF FUEL IT WILL USE. (PROPANE OR NATURAL GAS)
Detailed lighting instructions can be lo­cated above the safety label. See picture on page 16.
• If the knob does not pop up when released, stop and immediately call your service technician or gas supplier.
• If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service tech­nician or gas supplier.
• Let the pilot burn for 5 to 10 minutes prior to turning on the main burner.
11. Turn the gas control knob counterclockwise to “ON.”
12. Place the ON-OFF/THERMOSTAT switch in the ON position or in the THERMOSTAT position if the optional thermostat is used.
13. Turn on the electric power to the heater.
14. Set the optional thermostat to the desired room temperature.
Page 10
10
Operation
Air Shutter Adjustment
15. Set the High-Low Regulator to desired setting: Turn
fully counterclockwise for High and fully clockwise for Low.
NOTE: An odor, resulting from the initial heating of new
materials in your heater, is not unusual during the first fire, and in most cases will disappear after an hour or two.
HOW TO TURN OFF THE FIRE
1. If using optional thermostat, set thermostat to the
lowest position.
2. Turn off the electric power to the appliance.
3. Turn the ON-OFF/THERMOSTAT switch to the OFF
position.
4. Push in the gas control knob slightly and turn it
clockwise to “OFF.”
NOTE: The knob cannot be turned from “PILOT” to
“OFF” unless it is pushed in slightly. Do not force it.
Normal Flame pattern. Note: Flames will vary in height and position depending on the placement and the amount of ember wool.
AIR SHUTTER ADJUSTMENT
The adjuster can be accessed with a phillips screw driver just above the valve . Turn the adjuster clockwise to increase flame height and counterclockwise to de­crease. See above left. Adjusting the flames too high will cause them to have black tips and cause sooting. Sooting can cause the glass to get dirty.
Warning: The unit and adjuster may be hot. Wear gloves and arm protection if making adjustments while in operation.
PILOT FLAMES
If pilot flames are less than shown at left, have your service technician increase the pilot flame height.
Spark
Pilot
Pilot Flame Size
Ignitor Electrode
Pressing the ignitor button should produce a spark between the ignitor electrode and the pilot where shown above.
Page 11
Only For Qualified Installers
Packing List
Installation
11
Inside the Insert Box
ShadowLight XL Insert Log set Bag of rock wool Owners Manual Restrictor Plates
Inside Face Box
ShadowLight XL Face Right Door Left Door Hardware Pack
Page 12
12
Installation
Installation
“In the Commonwealth of Massachusetts, this product must be installed by a licensed Massachusetts Plumber or Gas Fitter”
Due to high temperatures, the ShadowLight XL Fireplace Insert should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the Shadow­Light XL Gas Fireplace Insert.
Clothing or other flammable materials should not be placed on or near the ShadowLight XL.
Surveiller les enfants. Garder les vêtements,
les meubles, l'essence ou autres liquides à
vapeur inflammables lin de l'appareil.
Only For Qualified Installers
CLEARANCES
The following clearances to combustibles must be
observed:
Unit to mantel 8” or smaller or combustible trim, unprotected ...13" (305 mm)
In addition to these clearances, adequate acces-
sibility clearance for servicing and proper operation must be maintained.
Only use Authorized Harman Service or Repair parts when working on your Shadowlight XL gas fireplace insert.
13”
Clearance from top of unit to mantel and combustible trim, unprotected
8”
13”
Page 13
Only For Qualified Installers
Making The Connection
The gas inlet is located on the bottom right side of the fireplace. The inlet fitting is 1/2” male flare fitting designed for 1/2” stainless flex pipe. This fitting can be removed to provide 3/8” female pipe thread.
A separate gas shut-off valve and a 1/8” N.P.T. plugged tapping should be installed immediately up­stream of the connection to the appliance.
The ShadowLight XL Direct Vent Gas Heater must be disconnected from the gas supply piping during any pressure testing of that system at pressures in excess of 1/2 psig (3.5 kPa).
The ShadowLight XL gas control valve must be in the OFF position during any pressure testing of the gas supply system at pressures equal to or less than 1/2 psig (3.5 kPa).
WARNING: To avoid pipe compounds from enter­ing into the gas train, apply compounds only to male pipe threads and do not apply compound to the first two threads.
Installation
13
Test Class
CONNECTING THE SHADOWLIGHT XL
FIREPLACE INSERT TO A GAS SUPPLY
Gas Line
CAUTION: TEST ALL JOINTS FOR LEAKS BE­FORE OPERATING.
Gas Pressure Requirements:
Correct gas pressure and the use of a properly sized gas supply line are essential for the safe and ef­ficient performance of this appliance. Make sure that the plumber or gas supplier checks the gas supply line and gas pressure at installation.
NOTE: Improper gas pressure can affect heater performance, flame color, or cause pilot outage.
Natural Gas:
Maximum inlet pressure 7.0” w.c. (1.74 kPa) Minimum inlet pressure 5.0” w.c. (1.25 kPa) Gas manifold pressure 3.5” w.c. (0.87 kPa)
LP Gas:
Maximum inlet pressure 13” w.c. (3.24 kPa) Minimum inlet pressure 11” w.c. (2.74 kPa) Gas manifold pressure 10” w.c. (2.49 kPa)
Note: Stove is built for propane. A conversion must be done to accomodate natural gas.
Do not connect the venting to the flue of a chimney that serves a separate solid-fuel burning appliance.
DO NOT USE THIS HEATER IF ANY PART HAS BEEN UNDER WATER, EXPOSED TO MOISTURE, OR SHOWS SIGNS OF CORROSION. IMMEDIATELY CALL A QUALlFlED SERVICE TECHNICIAN TO IN­SPECT THE HEATER AND REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.
Page 14
Inside Diameter
14
Installation
Only For Qualified Installers
Converting to Natural Gas
“This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the owner instructions sup­plied with the kit.”
Burn Only the Fuel for Which the Heater is
Equipped
This Conversion Kit Shall Be Installed By A
Qualified Service Agency.
The ShadowLight XL Fireplace Insert will burn either natural gas or propane, but requires a change over kit for converting to natural gas.
Cer equipenent de conversion sera installe par une agence qualifiee de service conformement aux instruc­tions du fabricant et toutes exigencies et codes appli­cables de l’autorises avoir la jurisdiction. Si l’information dans cette Instruction n’est pas suivie exactement, un feu, explosion ou production de protoxyde de carbone peut resulter le dommages causer de propriete, perte ou blessure personnelle de vie. L’agence qualifiee de service est esponsable de l’installation proper de cet equipement. L’installation n’est pas proper et complete jusqu’a l’operation de l’appareil converti est cheque suivant les criteres etablis dans les instructions de pro­prietaire provisionnees avec l’equipement.
Caution: Before proceeding with the conversion, the ga s su pply must be sh ut off prior to disconnecting the electrical power.
Note: The higher the orifice number the smaller the hole in the tip. For example, a number 52 orifice has a larger hole than a number 60 orifice.
The label located on the inner stove base must be marked for the type of fuel the unit will use at the time of installation.
LP and Natural Gas Conversion Kits
Pilot Orifice
Main Orifice #31 (Nat. Gas) Main Orifice #50 (LP)
Conversion label
Valve Conversion Module
Conversion Instructions
Do not stike glass or close door with excessive force. Breakage of glass and/or damage to door may result.
Natural Gas Kit Part No. 1-00-00384 LP Kit Part No. 1-00-00385
These kits are only for use in the
ShadowLight XL Insert.
Page 15
Only For Qualified Installers
Converting to Natural Gas
Installation
15
1
Door Hooks
Door Latches
Remove door by pulling latches out as shown and pulling the bottom of the door out from the unit about 3”. Then lift the door slightly up and off the hooks.
3
Remove air plate by lifting it up about 3 inches and then out of firebox. Be careful not to damage side brick panels
4
2
Remove log. Next, remove screw, washer and spacer from the center of the rear brick panel. Using one hand, gently push the side brick/relief door open slightly and using the other pull the top of the rear brick panel forward and remove it.
Remove the screws mounting the intake air deflector and lift it from the firebox. Next locate the screw holding the burner tube to the firebox floor and remove it. Now the #50 LPG burner orifice can be removed using a 1/2” deep well socket and replaced with a # 31 natural gas orifice.
Remove screw holding pilot air deflectors, and the deflectors, to allow access to the pilot tower. using a 7/16” wrench, take out the LP orifice and replace it with the natural gas orifice. Reassemble components adjusting pilot air deflectors allowing burner tube to slide over them and into place. Pilot orfices are marked NG and LP appropriately.
Burner
Pilot
The pilot must be placed in accordance with the above sketch for proper burner ignition.
Page 16
16
Installation
5
Only For Qualified Installers
Remove three screws to change knob assembly. Install NG knob assembly in place of the LP assembly. Be sure screws are tight.
Safety Label
6
Place conversion sticker (provided in Kit) on the valve. This is to permanently mark the valve that it has been converted to Natural Gas. This label is important in the event that the valve is ever removed and mixed in with other valves. Reassemble all components removed during the conversion process.
7
Mark the proper box on the fuel label with a permanent marker. Note: If no conversion is made, the box for propane must still be marked.
8
When installation has been completed, verify the gas inlet and manifold pressures are within specifications. The safety label, located inside the bottom of the unit, will have the information needed to verify correct operation. To read the safety label, pull the label out away from the unit. Be sure to use the information for the type of gas that it will be using.
You must check the unit for any gas leaks using soapy water or an electronic style leak detector.
Use soap and water and/or a gas detector to check for leaks before lighting the pilot.
Page 17
Converting to High Altitude
Specifications
17
1
Door Hooks
Door Latches
Remove door by pulling latches out as shown and pulling the bottom of the door out from the unit about 3”. Then lift the door slightly up and off the hooks.
3
Remove air plate by lifting it up about 3 inches and then out of firebox. Be careful not to damage side brick panels
4
2
Remove log. Next, remove screw, washer and spacer from the center of the rear brick panel. Using one hand, gently push the side brick/relief door open slightly and using the other pull the top of the rear brick panel forward and remove it.
Remove the screws mounting the intake air deflector and lift it from the firebox. Next locate the screw holding the burner tube to the firebox floor and remove it. Now the burner orifice can be removed using a 1/2” deep well socket and replaced with orifice required for type of fuel being used. Refer to safety label for orifice size.
If this is a new unit, the Natural Gas Conversion Kit must be used when installing the Natural Gas High Altitude Kit.
Page 18
18
Installation
Preliminary steps to prepare for the installation of the ShadowLight XL Fireplace Insert
Remove the chimney cap if one exists so that the flue may be cleaned and the venting installed.
Remove any existing hearth accessories such as glass doors, spark screens, andirons, and grates.
Clean the chimney thoroughly to remove ash, soot, and any obstructions, and then clean ash, soot, dust, and debris from the fireplace.
The damper must be locked open to allow the 3" venting to pass through. If it is necessary to modify the damper area to allow passage of the venting, the modifications should be allowed under local codes. Confirm any planned changes with local building officials.
Only For Qualified Installers
Venting
Use Only Approved Venting
Observe local codes when venting the ShadowLight XL. If no local codes exist, follow ANSI Z21.88-2002 installation code.
Do not connect the venting to the flue of a chimney that serves a separate solid-fuel burning appliance.
The venting manufacturer's installation instructions must be followed exactly.
The most efficient venting systems are those that have a minimum number of bends and minimal horizontal runs.
WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.
Exhaust restrictor plates must be installed depending on type of gas and chimney height. See page 20 to determine restrictor.
“Warning: Failure to position parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.”
Page 19
Only For Qualified Installers
Installation
19
Use Only Approved Venting
This appliance has been tested and is listed for installation with Simpson Duravent GS and Duraflex AL venting components. The warranty will be voided, and serious fire, health, or other safety hazards may result from any of the following actions:
• Installation of any damaged Simpson Duravent
component.
• Unauthorized modification of the Simpson Du-
ravent System.
• Installation of any component part not manufac-
tured or approved by Simpson Duravent.
• Installation other than as instructed by Simpson
Duravent and the appliance manufacturer.
Consult your local building codes before begin­ning the installation, and follow the manufacturer’s instructions exactly. The Simpson Duravent venting components listed below are approved for use with the ShadowLight XL Direct Vent Gas Insert.
Chimney Cap Components
A bead of silicone goes between the top of the tile liner and the flashing to seal the cap to the chimney
Flashing
Tile Liner
Vent Pipe
Air Intake Pipe
Typical Chimney
Figure__
Duraflex AL - Flexible Aluminum Pipe Lengths
Size Length Stock #
High Wind Cap Stock# 991
Chimney Liner Termination Kit. Includes flashing. Stock # 923GK
Air Intake
Flashing
3” 25’ 2270 3” 35’ 2280 3” 50’ 2290
Minimum vertical vent pipe length is 10 Feet. Maximum horizontal distance is 36”.
Vent
Uncoil the three inch aluminum chimney liners on the ground and measure to make sure the pipes are long enough. Mark one of the liners at both ends with paint and use it for the exhaust side connection. Once they are in the chimney it allows easier identification of intake and exhaust connections.
Page 20
20
Installation
Only For Qualified Installers
Venting and Installation
1
Feed chimney liners down the chimney and through the damper.If the fireplace opening does not allow enough room to connect the flue liners to the stove it is necessary to separate the exhaust/ intake pipe adapter from the stove body. Approximately 4 inches clearance above the top of the glass door is needed to allow connection of the liners. This must be determined by the installer.
3
Remove the screw, washer and spacer from the center of the rear brick panel. Using one hand, gently push out on the side brick /relief door to allow clearance for removing the rear brick panel.
2
Door Latches
Open the glass door by pulling out on the 2 latches located on the bottom of the door frame. Pull the bottom out a couple of inches and lift the door off of the stove body and set safely out of the way. Remove the bag of rock wool, packaging materials and log set from inside the firebox.
Skip steps 3 thru 5 not need removed for in
if intake / exhaust adapter does
stallation.
4
Remove 2 screws holding exhaust cover plate onto the rear of the firebox and remove cover.
Page 21
Only For Qualified Installers
Installation
21
5
Using a 1/2” deep well socket loosen the nut that was under the exhaust cover plate until it is flush with the end of the threads. Pull the exhaust clamp down from notch in firebox top. Lift the clamp assembly up and disconnect it from the intake / exhaust adapter.
Remove exhaust adapter from the top of the stove assembly being careful not to damage the sealing gasket.
6
7
The flue restrictor can be installed after flex pipes are connected and stove is in fireplace opening. To change or install restrictor remove glass door then remove log . Next remove screw, washer and spacer in the rear brick panel and remove the brick panel while holding relief door open with one hand. Remove the 2 screws holding the exhaust cover onto the rear of the firebox.
To remove a restrictor push the front of the plate upward and pull down on the rear side bringing it into the firebox.
To install a restrictor, hold plate vertically and slide up into exhaust connector through the back of the firebox. Push bottom of plate back allowing it to set onto lip inside the exhaust adapter.
8
Look through to connect “J” bolt.
Flue Restrictor
Determine the flue restrictor needed for this application and install into the exhaust pipe on the stove adapter.
Propane uses the 2” ID restrictor for 10’ to 16’ and
the 1.75” ID for the 16’ to 36’ chimneys.
Natural gas uses no restrictor from 10’ to 16’ and
the 1.75” restrictor from 16’ to 36’.
Lay cardboard or an old cloth onto the fireplace hearth to keep from damaging it. If the pipe adapter has been removed from the stove body connect the flex pipes to the intake/exhaust adapter assembly, be sure to use the correct pipe on the exhaust connector, the one that was marked with paint earlier. Tie a string to the exhaust adapter so you can pull the adapter onto stove body.
Check stove to opening side clearance. If there is not enough room to reach beside stove while it is installed you may want to remove the gas line from the valve assembly and connect it to your supply line inside the fireplace first, then reconnect to the gas valve.
Set stove into fireplace opening. Connect the pipe adapter or flex liners to the stove. To reconnect the pipe adapter use the string or reach through the exhaust passage and pull the adapter onto the stove body. While looking through the center exhaust port located toward the front of the firebox, connect the “J“ bolt to the adapter. Next slide the clamping adapter into the notch in the firebox top and tighten the nut. Remove the string when completed.
Page 22
22
Installation
Only For Qualified Installers
9
Connect the gas pipe to the stove unit. If the pipe adapter was removed from the stove, replace all components back onto the stove in the reverse order from which they were removed.
11
Place rock wool on burner as shown above. The wool should be placed loosely and lightly. This wool forms the glowing ember bed and will look different depending on placement. Reinstall the glass door assembly and close the latches.
Do not stike glass or close door with excessive force. Breakage of glass and/or damage to door may result.
10
Place log set in firebox. Center the logs right to left and push back against the log stop.
The power cord comes out the right side of the unit from the factory. The power cord may be changed to the left side before installing the face. Start by bringing the plug end of the cord back through the side of the firebox, and lifting the strain relieved cord section up from body notches. Keeping the cord along the front of the stove bottom run the plug end under the label holding brackets and out the same area on the other side of the stove body. Press the strain relieved cord section into the notches on the left side of the stove body and secure the cord to the front bottom section of the stove using wire ties.
12
Back out the 4 face clamping bolts far enough to install the face. Slide the face onto the firebox assembly until the slots are just fully under the heads of the bolts and are all even, then tighten the 4 bolts as shown above. Check to see if the back of the stove face meets with the fireplace opening as neatly as possible, some adjustment may be necessary. If the face is slid too far back under the bolts the glass door will not be able to be removed without taking the face off first. Some applications may be required to be installed that way.
Page 23
Only For Qualified Installers
Installation
23
13
Install the face doors by hanging them on the hinges. Note: a brass washer goes between the hinges. The finished installation should look like this.
Installation Check List
1. Verify unit is assembled for correct gas application. If not, install conversion kit available from Harman Stove Company.
2 Make sure gas line is installed in the fireplace to a point that it can be reached during installation.
3. Install inlet and vent pipes into chimney.
4. Remove glass door by pulling out on the two latches at the bottom of the door. Then lift up and out on the door.
5. Remove flex pipe adapter from the stove body if there is not enough clearance to do the connection as­sembled.
6. Protect hearth with drop cloth or cardboard.
7. Install flue restrictor if needed
8. Connect flex pipes to pipe adapter, and if removed, connect adapter to stove body. Keep marked flex liner to the exhaust side.
Brass Washer
14
Finish installing chimney cap. Secure flex pipes to cap base using screws, be sure to connect the painted flex pipe for exhaust to the proper side on the base. Now secure base to the chimney using screws, silicone, a combination of the two, or another approved method.
The appliance must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current NFPA 70 National Electric Code or CSA C22.1-Canadian Electrical Code.
“This appliance is equipped with a three prong (grounded) plug for protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG.”
9. Reinstall all components that were removed if the pipe adapter was removed from the stove body.
10. Connect Gas line to the unit. Check for leaks using an approved method.
11. Change power cord to opposite side of unit if de­sired.
12. Install log, rock wool and glass door
13. Install Face assembly and adjust to opening.
14. Install chimney cap and mounting adapter
15. Check for leaks, then verify correct operation of stove.
Page 24
24
Installation
Thermostat
Part # 3-20-12080
Only For Qualified Installers
Connecting the Optional Thermostat
If the optional thermostat is used, it must be plugged into the terminal strip located in the lower left front corner of the heater.
When installing a millivolt control system, use only a special low resistance thermostat. DO NOT USE A REGULAR HEATING THERMOSTAT.
Be sure that all electrical connections are clean, free from corrosion, and tight. Inspect connections periodically to confirm that no corrosion has built up over time.
When properly installed and maintained, a millivolt control system should give many years of trouble-free service.
It is important to use the proper gauge wire for the length used.
Burner Button
RECOMMENDED WIRE GAUGES
Maximum Wire Length Gauge
100’ 14 60’ 16 40’ 18 25’ 20 15’ 22
Remote Control
The button on the remote control can be used to turn the burner on and off.
This remote uses an ultrasonic control method and does not need to be pointed directly at the fireplace.
A hand held sending unit, receiving unit, mounting bracket and all wiring are included when you order the remote control.
Part # 1-00-7911
Installation instructions are packed with remote kit.
Page 25
Maintenance
25
A qualified service technician recommended by your Harman dealer should conduct an annual inspection and maintenance of your fireplace, its venting, and the installation to keep it running safely and efficiently. The following procedures should be performed only by a qualified service person. The gas supply should be turned off whenever a maintenance procedure is performed.
If the glass front, or front access door are removed for servicing, they must be replaced prior to operating the fireplace.
Replacing the Glass and Gasket
The ShadowLight XL uses part no. 3-44-00539 fiberglass gasket in the front door. Should it ever need replacement, use only the proper replacement gasket that is available from your Harman dealer. To replace the gasket, follow this procedure.
1. Lay glass front face down.
2. Bend the four tabs up far enough to remove the glass.
3. Remove glass from frame. Discard gasket.
4. Install new gasket around glass (thick side toward stove).
5. Place glass in frame.
6. Bend tabs to secure glass. Not too tight.
7. Reinstall glass door by placing the door on the hooks at the top of the opening as shown. swing the bottom of the door in to the unit. Close the two latches to secure the door.
Removing the Glass Door
Remove door by pulling latches out as shown and pulling the bottom of the door out from the unit about 3 inches. Then lift the door slightly up and off the hooks.
DO NOT STRIKE OR SLAM GLASS.
WA R N I N G : D O NOT O PERAT E T H I S APPLIANCE WITH THE GLASS FRONT REMOVED, CRACKED OR BROKEN. REPLACEMENT OF GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON. NEVER USE SUBSTITUTE MATERIALS.
Cleaning the Glass
The glass may be cleaned with ordinary household glass cleaner and a soft cloth or paper towel.
WARNING: Never clean the glass when it is hot. Do not use abrasive cleaners on the glass.
Inspecting the Venting
An inspection of both pipes of the venting system should be made during the annual service appointment. They must have no blockage and be in good condition. The vent manufacturer’s instructions may provide specific suggestions or details on vent inspection. Any sections that are taken apart for the inspection must be reassembled and sealed as required.
Cleaning the Log Set and Firebox
During the annual inspection and maintenance appointment, the service person should clean dust, lint, and any light accumulation from the logs and the firebox area. An extra-soft brush should be used on the logs as they are extremely fragile; a vacuum cleaner may be used on the firebox. If at any time the logs cannot be removed or installed without forcing, the cause must be found. The logs must never be forced.
Page 26
26
Maintenance
Air Out
Air Flow
To prevent damage to the heater, it is essential that air flows freely into the bottom grill and out of the top grill. Do not place objects in front of the grills.
Cleaning the Burners
To clean the burners, the face, glass front, and log set must be removed. Remove the burner assembly as described on page 15.
With the burner removed, inspect all of the holes to make sure they are unobstructed. Use a small drill or wire to clean any obstructed holes. Remove any rust or other buildup that may have accumulated.
Air In
The flow of convection air must not be obstructed.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. “Verify proper operation after servicing.”
“Attention: Au moment de l’entretien des commandes, eriquetez tous les fils avant le debranchement. Des erreurs de c>blage peuvent entraTun fonctionnement inadequar et dangereux.”
The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
Replace burner in reverse order.
Replacing The Blower
To replace the blower the stove must be removed from the fireplace.
1. Shut off power and gas to stove
2. Remove face assembly
3. Remove glass door
4. Remove log, Rear brick panel and firebox rear cover plate.
5. Loosen nut on “J” bolt under the cover and remove “J” bolt
6. Disconnect power cord and gas line
7. Protect hearth
8. Remove stove from fireplace being careful not to damage flex pipes while removing adapter from the top of the stove.
9. Remove rear cover from stove body
10. Disconnect wires from blower motor
11. Remove screws mounting blower to blower mount
12. Replace blower.
“If the vent/air intake system is disassembled for any reason, reinstall per the instructions provided for the initial installation.”
Only use Authorized Harman Service or Repair parts when working on your Shadowlight XL gas fireplace insert.
13. Assemble in reverse order.
Page 27
MAGENTA
A
MAGENT
External Thermostat/
Remote Terminals
MAGENTA
Wiring Diagrams
Low Voltage DIagram
27
MAGENTA
Blower
Blower Switch
Power Cord
Variable Speed Switch
High Voltage DIagram
Page 28
28
Shadowlight XL Parts
16. Body Weldment 1-89-384300
17. Flue Access Cover 2-00-384307
18. AIr Plate Assembly 1-10-384307
19. Low Voltage Harness 3-20-384329
20. Air Deflector 2-00-384311
21. Control Panel Assembly 1-10-384130
22. Relief Door Assembly(6parts)
2-00-384322-1 left relief door
2-00-384322-2 right relief door
2-00-384326-1 left relief dr gasket retainer
2-00-384326-2 right relief door gasket retainer
3-44-384327 relief door gasket
3-31-03291 relief door spring
23. HCS ¼-20 x 3 Relief Bolt: 3-30-1252030013
1. Face Assembly 1-00-384200
2. Glass Door Assembly 1-10-384148
3. Glass 3-40-18502900
4. Label Bracket Assy. 1-10-384136
5a. Side Brick Panel 3-40-384319 (1 left, 2 right)
5b. Rear Brick Panel 3-40-384318
6. Valve Assembly 1-10-384329
7. Power Cord 3-20-384328
8. Blower Mount 2-00-384315
9. Rear Cover 2-00-384317
10. Blower Motor 3-21-32080
11. Tail Pipe Weldment 1-00-384314
12. Restrictors 2-00-384321(2”) 2-00-384323 (1.75”)
13. Tail pipe Gasket 3-44-384328
14. “J” Bolt
15. Flue Clamp Weldment 1-10-384343
Page 29
Burner Module Parts
29
1. Piezo Igniter 3-40-08220
2. Spacers 3-31-90309017
3. Snap Disc 3-20-408412
4. #10 Tek Screws 3-30-511007517
5. Valve Mounting Screws 3-30-10050081
6. 1/4” x 20 nuts 3-30-80252013
7. 1/4” x 20 x 1/2” bolts 3-30-1252005014
8. 5/12” x 18 x 6” Pan Headbolt 3-30-631186001
9. 5/16” x 18 nuts 3-30-80311813
10. Adjuster Disc 2-00-384142
11. Gas Tube 2-00-384128
12. Control Valve 3-40-820653
13. Burner Floor 2-00-384329
14. OPS Elbow 3-40-08779
15. Tube Box Top 2-00-384135
16. Pilot Cover Rear 2-00-384346
17. Pilot Cover Front 2-00-384345
18. Pilot Assembly 3-40-08715
19. #10 x 3/4” Tek Screws 3-30-511007517
20. Pilot SEaler Plate 2-00-384120
Page 30
30
Trouble Shooting
Manifold Pressure
Natural Gas
Inlet Pressure 5
3.5 inches
(High-Low Regulator turned fully counter-clockwise.)
To connect test gauges, insert screwdriver into port and turn counter-clockwise one to two turns. Then install gauge hose onto fitting.
Pilot Adjuster
to 7 inches
If pre ssures a re not ac cordin g to specification, contact your Authorized Harman Dealer.
Manifold Pressure
10 inches
(High-Low Regulator turned fully counter-clockwise.)
To connect test gauges, insert screwdriver into port and turn counter-clockwise one to two turns. Then install gauge hose onto fitting.
Propane
Inlet Pressure 11
to 13 inches
If pressures are not according to specification, contact your Authorized Harman Dealer.
Pilot Adjuster
Page 31
Pilot does not light after many tries
Trouble Shooting
31
Look to see if a spark jumps from the ignitor electrode to the pilot when the ignitor button is pushed.
Yes
No
Check igniter wire and connections from piezo ignitor to ignitor ceramic at pilot.
OK
Check Igniter Ceramic for cracks
OK
Check Piezo Igniter to make sure the small wire on the mounting flange is grounded.
OK
Replace Piezo Igniter
Bad
Bad
Bad
Reconnect or replace
Igniter wire.
Replace
Clean paint or rust from around mounting hole.
Is gas turned “on”?
Yes
Is there gas in tank (LP) or line (NG)
Yes
Purge gas line to stove
OK
Check pilot orifice and pilot line for blockage.
No
No
Turn on gas valve
Replenish supply
Page 32
32
Trouble Shooting
Pilot does not stay lit
Check inlet pressure
Good
Check size of pilot flames
Good
Check Milivolt output of thermocouple. Should be 10 or more MV.
Good
Replace Valve
Bad
Bad
Bad
Correct inlet pressure
Adjust pilot adjustment to achieve proper flame.
Replace Thermocouple
Page 33
Main Burner will not light (with valve in “on” position)
Trouble Shooting
33
Is Pilot lit
Yes
Check Thermopile voltage at terminals marked TP on valve. Should be approximately 200 mv with switch “on” and approximately 400 mv with switch “off”.
OK
Check switch, wires, and wiring connectors.
OK
no
too low
bad
Light pilot
Replace Thermopile
Correct problem
Replace valve
Page 34
34
HARMAN GOLD WARRANTY 6 YEAR TRANSFERABLE LIMITED WARRANTY (Residential)
1 YEAR LIMITED WARRANTY (Commercial)
Harman Stove Company warrants its products to be free from defects in material or workmanship, in normal use and service, for a period of 6 years from the date of sales invoice and for mechanical and electrical failures, in normal use and service, for a period of 3 years from the date of sales invoice.
If defective in material or workmanship, during the warranty period, Harman Stove Company will, at its option, repair or replace the product as described below.
The warranty above constitutes the entire warranty with respect to Harman Stove Company products. HAR­MAN STOVE COMPANY MAKES NO OTHER WARRANTY, EXPRESSED OR IMPLIED, INCLUDING “ANY” WARRANTY OF MERCHANTABILITY, OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. No employee, agent, dealer, or other person is authorized to give any warranty on behalf of Harman Stove Company. This warranty does not apply if the product has been altered in any way after leaving the factory. Harman Stove Company and its agents assume no liability for “resultant damages of any kind” arising from the use of its products. In addition, the manufacturer and its warranty administrator shall be held free and harmless from liability from dam­age to property related to the operation, proper or improper, of the equipment.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF.
THESE WARRANTIES APPLY only if the device is installed and operated as recommended in the user’s manual.
THESE WARRANTIES WILL NOT APPLY if abuse, accident, improper installation, negligence, or use beyond rated capacity causes damage.
HOW TO MAKE A CLAIM - Any claim under this warranty should be made to the dealer from whom this ap­pliance was purchased. Then contact is made with manufacturer, giving the model and serial numbers, the date of purchase, your dealer’s name and address, plus a simple explanation of the nature of the defect. Extra costs such as mileage and overtime are not covered. Nuisance calls are not covered by these warranties.
THIS WARRANTY IS LIMITED TO DEFECTIVE PARTS - REPAIR AND/OR REPLACEMENT AT HARMAN STOVE COMPANY’S OPTION AND EXCLUDES ANY INCIDENTAL AND CONSEQUENTIAL DAMAGES CONNECTED THEREWITH.
WARRANTY EXCLUSIONS: Failure due, but not limited to, fire, lightning, acts of God, power failures and/or surges, rust, corrosion and venting problems are not covered. Damage and/or repairs including but not limited to; remote controls, filters, fuses, knobs, glass, ceramic brick panels, ceramic fiber afterburners, door packing, tile, ceramic log sets, paint, batteries or battery back-up and related duct work are not covered. Also excluded from this warranty are consumable or normal wear items including but not limited to; flame guides, grates, coal bars, after­burner hoods, fire brick, gaskets. Additional exclusions for corn stoves are burnpot housing weldment, burnpot grate weldment (pellet or corn), burnpot front plate (pellet or corn), burnpot front plate lock, corn auger extension, ceramic insert, and ceramic insert plate. Additional or unusual utility bills incurred due to any malfunction or defect in equip­ment and the labor cost of gaining access to or removal of a unit that requires special tools or equipment are not covered. Maintenance needed to keep the stove in “good operating condition” is not covered. This includes, but is not limited to, cleaning, adjustment of customer controls and customer education. Labor, materials, expenses and/or equipment needed to comply with law and/or regulations set forth by any governmental agencies are not covered.
This Warranty provides specific legal rights and the consumer may have other rights that vary from state to state.
In the event of change in ownership, the remaining portion of this warranty may be transferred to the new owner by sending the new owner information and a transfer fee of $25.00 US to the Harman Stove Company.
PLEASE READ THE LITERATURE BY THE MANUFACTURER FOR THE VARIOUS ACCESSORY DE­VICES. THE MANUFACTURER WARRANTS THESE ACCESSORY DEVICES, NOT HARMAN STOVE COM­PANY OR THEIR WARRANTY ADMINISTRATOR. FURTHERMORE, THESE ACCESSORY DEVICES MUST BE INSTALLED AND USED ACCORDING TO THE RECOMMENDATIONS OF THE MANUFACTURER.
REMEDIES - The remedies set forth herein are exclusive and the liability of seller with respect to any contract or sale or anything done in connection therewith, whether in Contract, in tort, under any warranty, or otherwise, shall not, except as herein expressly provided, exceed the price of the equipment or part of which such liability is based.
CLARIFY - The above represents the complete warranty, which is given in connection with stoves, manu­factured by Harman Stove Company. No other commitments, verbal or otherwise, shall apply except by a written addendum to this warranty.
Loading...