Haier HSU-09LB11T, HSU-07LEK03, HSU-09LD11T, HSU-12LB11T, HSU-12LD11T Installation Manual

...
0 (0)
Installation Manual of Room Air Conditioner
No.0010518787
Read this manual before installation
1.Driver
2.Ha
cksaw
3.Hole core d
4.Spanner(17,19 and 26mm)
5.
Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Fla
ring tool
8.Kni
fe
9.Nipper 12.Reamer
10.Gas leakage detector or soap-and-
water solution
11.Measuring tape
Explain sufficiently the operating means to the user according to this manual.
A
B
C
D
E
F
G
Optional parts for piping
Mark
Parts name
Non-adhesi
ve tape
Adhesi
ve tape
Saddle(L.S) with scr
ews
Connecting elect
ric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole c
over
Arrangement of piping directions
Rear left
Rear right
Left
Below
Right
The marks from to in the figure are the parts numbers.
The distance between the indoor unit and the floor should be more than 2m.
A
G
Attention must be paid to the rising up of drain hose
mc5na
h
ter
om
m
c
0
1
n
a
h
t
e
r
o
m
m
c
0
1
n
a
h
t
e
r
o
m
A
C
No. Accessory parts
Remote controller
R-03 d
ry battery
Mounting plate
Drain hose
Steel nail, cement
Screw
Plastic cap
Drain-elbow
Cover
Cushion
1
1
2
3
4
5
6
7
8
9
10
2
1
1
6
4
1
1
4
1
Number of articles
Accessory parts
4X50
4X25
Pipe supporting plate
11
Connecting cable
1
m
c
0
1
n
a
h
t
e
r
o
m
m
c
0
6
n
a
h
t
e
r
o
m
m
c
5
1
n
a
h
t
e
r
o
m
m
c
0
1
n
a
h
t
e
r
o
m
D
E
Note:Cooling only units don't have Drain-elbow
Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation
Selection of pipe
To this unit, both liquid and gas pipes
Iow temperature in operation. Use optional parts for piping set
insulation material.
2
Liquid pipe ( )
For 05 07 09 108
6.35mm(1/4")
Gas pipe ( )
9.52mm(3/8")
For 12 18 138
12.7mm(1/2")
HSU-09HEK03
HSU-09LEK03
HSU-12HEK03
HSU-12LEK03
6.35mm(1/4")
HSU-09LEK13 HSU-12LEK13 HSU-07LEK03 HSU-07HEK03
1.Fitting of the Mounting Plate and Positioning of the wall Hole
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
When the mounting plate is first fixed
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
Make a hole of 60 mm in diameter, slightly descending to outside the wall. Install piping hole cover and seal it off with putty after installation
Indoor unit
(Section of wall hole)
Piping hole pipe
Outdoor side
Thickness of wall
Indoor side
Wall hole
60mm
G
A=145mm
B= 60mm
30mm
HSU-09LEK03/ (DB) HSU-12LEK03/ (DB)
HSU-18LEK13
60mm
30mm
HSU-108CH09 HSU-138CH09
30mm
HSU-12LEK13-M
< 12K
Floor fixing dimensions of the outdoor unit
(Unit:mm)
Floor fixing dimensions of the outdoor unit (Unit:mm)
140
500
140
256
113.5
583
113.5
19 5. 3
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
140 140415
280
15.88mm(5/8")
9.52mm(3/8")
For >24
HSU-24LEK13
A=145mm
B= 60mm
A=145mm
B=
HSU-18HEK03
18K
HSU-24HEK03
24K
HSU-18LEK03/ (DB)
HSU-18LK2S3
HSU-12LEK03-Y3
HSU-24LK2S3
HSU-18LEK03-Y3
HSU-24LEK03-Y2
HSU-09CK2S3
HSU-09LEK03-Y3
HSU-12CK2S3
HSU-108CH09 HSU-138CH09
HSU-09LB11T HSU-09LD11T HSU-12LB11T HSU-12LD11T
HSU-18LD11T
HSU-18LB11T
HSU-24LD11T
HSU-05LEK03-Y HSU-07LEK03-Y HSU-09LEK03-Y HSU-12LEK03-Y
HSU-18LEK03-Y
HSU-09LB11 HSU-09LD11
HSU-22LB11 HSU-22LD11
HSU-12LB11
HSU-12LD11
HSU-18LB11
HSU-18LD11
HSU-09LEK03-Y2
HSU-12LEK03-Y2 HSU-18LEK03-Y2
HSU-24LEK03-Y3
HSU-18LEK03
HSU-09CK2W3 HSU-09CK6B3 HSU-12CK2W3 HSU-12CK6B3 HSU-18LK2W3 HSU-18LK6B3
SAS-09HEK3 SAS-12HEK3
SAS-18HEK3
SAS-24HEK3
HSU-12LEK03-Y5
HSU-09LEK03-Y5
HSU-12LH03
HSU-09LH03
HSU-18LEK03-Y5 HSU-18LH03
HSU-24LEK03-Y5
HSU-24LH03
Floor fixing dimensions of the outdoor unit (Unit:mm)
HSU-12HH03
HSU-09HH03
HSU-18HH03
HSU-24HH03
HSU-12HEG03
HSU-09HEG03
HSU-18HEG03
HSU-24HEG03
HSU-18LEK03-Y5(6) HSU-18LH03
HSU-12LEK03-Y5(6) HSU-12LH03
HSU-18LEK03-Y6
HSU-18HH03 HSU-18HEG03 HSU-18LEK03-Y6
YKS-18HEK03
YKS-24HEK03
HSU-12LEK03-Y6
HSU-09LK03
HSU-12LK03 HSU-18LK03
HSU-12LEK03-Y4
HSU-09LEK03-Y4
HSU-24LEK03-Y4
HSU-24LEK03-Y6
HSU-18LK2W3 HSU-18LK6B2
HSU-24LK2S2
HSU-12CK6B2
HSU-24LEG03(T3)
HSU-18LEG03(T3) HSU-18HEG03(T3)
HSU-18LEG03(T3) HSU-18HEG03(T3)
shall be insulated as they become
or pipes covered with equivalent
HSU-18LK0G3
HSU-24HEG03(T3)
HSU-12HEK03-Y5
HSU-24LEK03
HSU-18LEK03EK1
HSU-12LKN03 HSU-18LKN03
HSU-09LKN03
HSU-30LEG13(T3) HSU-30HEG13(T3)
HST-30LEG13(T3) HST-30HEG13(T3)
HST-18LEG13(T3) HST-18HEG13(T3)
HST-24LEG13(T3) HST-24HEG13(T3)
HSU-12HEG13(T3)
HSU-07LEK03/Y
HSU-05LEK03
HSU-26HEK03
HSU-24LEAA13(T3) HSU-24HEAA13(T3)
HSU-09LEE12
HSU-09LEW12
HSU-12LEE12 HSU-12LEW12
HSU-18LEE12 HSU-18LEW12
HSU-24LEE12 HSU-24LEW12
HST-18LEG03(T3)
HST-24LEG03(T3)
HST-18LEG03(T3)