Groen SSB-10G Installation Manual

OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
This manual provides information for:
MODELS SSB-3G/5G/10G & (2)SSB-3G/5G/10G Domestic SMARTSTEAM100™ BOILERLESS STEAMER
· Self Contained
· Gas Heated
· Capacity: SSB-3G=3 Steamer Pans Per Cavity SSB-5G=5 Steamer Pans Per Cavity SSB-10G=10 Steamer Pans Per Cavity
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
POST IN A PROMINENT LOCATION
Instructions to be followed in the event user smells gas. This information shall be obtained by consulting your local gas supplier. As a minimum, turn off the gas and call your gas company and your authorized service agent. Evacuate all personnel from the area.
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and main thoroughly before installing or servicing this equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage, including concealed dam­age. Unified Brands suggests that if you are suspicious of damage to make a notation on the delivery receipt. It will be the responsibility of the consignee to file a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be current and accurate at the time of printing/creation. Unified Brands recommends referencing our product line websites, unifiedbrands.net, for the most updated product information and specifications.
PART NUMBER 145144, REV. L (10/09)
PART NUMBER 145144, REV. H (12/07)
tenance instructions
.ECNEREFER ERUTUF ROF DENIATER EB TSUM LAUNAM SIHT
1055 Mendell Davis Drive
Jackson, MS 39272
888-994-7636, fax 888-864-7636
groen.com
IMPORTANT –– READ FIRST –– IMPORTANT
WARNING: THE UNIT MUST BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY
AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES.
CAUTION: SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
CAUTION: DO NOT INSTALL THE UNIT IN ANY WAY WHICH WILL BLOCK THE REAR VENTS, OR
WITHIN 2 INCHES OF A HEAT SOURCE SUCH AS A BRAISING PAN, DEEP FRYER, CHAR BROILER OR KETTLE.
CAUTION: LEVEL THE UNIT FRONT TO BACK, AND PITCH IT SLIGHTLY TO THE FRONT, TO AVOID
DRAINAGE PROBLEMS.
WARNING: FOLLOW THE WIRING DIAGRAM EXACTLY WHEN CONNECTING A UNIT TO AVOID
DAMAGE OR INJURY. WIRING DIAGRAM IS LOCATED ON THE INSIDE OF THE RIGHT PANEL.
CAUTION: DO NOT USE PLASTIC PIPE. DRAIN MUST BE RATED FOR BOILING WATER.
WARNING: DO NOT CONNECT THE DRAIN DIRECTLY TO A BUILDING DRAIN.
WARNING: BLOCKING THE DRAIN IS HAZARDOUS.
IMPORTANT: IMPROPER DRAIN CONNECTION WILL VOID WARRANTY.
IMPORTANT:
DO NOT ALLOW ANY WATER TRAPS IN THE DRAIN LINE. A TRAP CAN CAUSE PRESSURE TO BUILD UP INSIDE THE CAVITY DURING STEAMING, WHICH WILL MAKE THE DOOR GASKET LEAK.
WARNING: WHEN YOU OPEN THE DOOR, STAY AWAY FROM STEAM COMING OUT OF THE UNIT.
STEAM CAN CAUSE BURNS.
WARNING: BEFORE CLEANING THE OUTSIDE OF THE STEAMER, DISCONNECT THE ELECTRIC
POWER SUPPLY. KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS. NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT.
WARNING: ALLOW COOKING CHAMBER TO COOL COMPLETELY BEFORE CLEANING.
WARNING: USE MILD CLEANING AGENTS ONLY. CAREFULLY READ THE WARNINGS AND FOLLOW
THE DIRECTIONS ON THE LABEL OF EACH CLEANING AGENT. USE SAFETY GLASSES AND RUBBER GLOVES AS RECOMMENDED BY CLEANING AGENT MANUFACTURER.
WARNING: DO NOT PUT HANDS OR TOOLS INTO THE COOKING CHAMBER UNTIL THE FAN HAS
STOPPED TURNING.
WARNING: DO NOT OPERATE THE UNIT UNLESS THE REMOVABLE RIGHT SIDE PANEL HAS BEEN
RETURNED TO ITS PROPER LOCATION.
NOTICE: DO NOT USE A CLEANING AGENT THAT CONTAINS ANY SULFAMIC ACID, OR ANY
CHLORIDE, INCLUDING HYDROCHLORIC ACID. IF THE CHLORIDE CONTENT OF ANY PRODUCT IS UNCLEAR, CONSULT THE MANUFACTURER. DO NOT USE A CLEANING OR DELIMING AGENT THAT CONTAINS MORE THAN 30% PHOSPHORIC ACID.
NOTICE: DO NOT USE ANY DEGREASER THAT CONTAINS POTASSIUM HYDROXIDE OR SODIUM
HYDROXIDE OR THAT IS ALKALINE.
WARNING: USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR
AUTHORIZED DISTRIBUTOR VOIDS ALL WARRANTIES AND CAN RESULT IN BODILY INJURY TO THE OPERATOR AND DAMAGE THE EQUIPMENT. SERVICE BY OTHER THAN FACTORY-AUTHORIZED PERSONNEL WILL VOID ALL WARRANTIES.
WARNING: HIGH VOLTAGE EXISTS INSIDE CONTROL COMPARTMENTS. DISCONNECT FROM BRANCH
CIRCUIT BEFORE SERVICING. FAILURE TO DO SO CAN RESULT IN INJURY OR DEATH.
2 OM-SSB-G
OM-SSB-3G/5G/10GF
Table of Contents
OPERATOR WARNINGS......................................................................................................................................... 2
REFERENCES......................................................................................................................................................... 3
EQUIPMENT DESCRIPTION................................................................................................................................... 4
INSPECTION AND UNPACKING ............................................................................................................................ 4
INSTALLATION AND STARTUP ............................................................................................................................. 5
OPERATION ............................................................................................................................................................ 9
CLEANING............................................................................................................................................................. 11
MAINTENANCE..................................................................................................................................................... 13
TROUBLESHOOTING........................................................................................................................................... 13
PARTS LIST........................................................................................................................................................... 15
WIRING DIAGRAM .................................................................................................................................................. 19
References
UNDERWRITERS LABORATORIES, INC. NATIONAL FIRE PROTECTION ASSOCIATION 333 Pfingsten Road 60 Batterymarch Park Northbrook, Illinois 60062 Quincy, Massachusetts 02269
NFPA/70 The National Electrical Code NFPA/ 54 The National Fuel Gas Code
NATIONAL SANITATION FOUNDATION
3475 Plymouth Road
Ann Arbor, Michigan 48106
SERVICE LOG....................................................................................................................................................... 20
WARRANTY PROTECTION .................................................................................................................................. 21
NSF INTERNATIONAL 789 N. Dixboro Rd. P.O. Box 130140 Ann Arbor, Michigan 48113-0140
OM-SSB-G 3
OM-SSB-3G/5G/10GF
Equipment Description
Your Groen SSB-3G/5G/10G or (2)SSB-3G/5G/10G
SmartSteam100 Boilerless Steamer is designed to
give years of service. It has a stainless steel cavity (cooking chamber) which is served by a gas-heated atmospheric steam generating reservoir. A powerful blower circulates the steam in the cavity to increase
heating efficiency.
Each cavity holds up to three, five or ten steam table
pans (12” x 20” x 21/2” deep) as shown below.
An 18-guage stainless steel case encloses the cavity, the steam generating reservoir and the control compartment that houses electrical components.
Door hinges are field-reversible (the door may be set
to open from the left or right). Operating controls are on the front panel.
Your Groen SmartSteam100 Boilerless Steamer will be delivered completely assembled in a heavy shipping carton strapped to a skid. On receipt, inspect carton carefully for exterior damage.
CAUTION SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
Carefully cut the straps and detach the sides of the carton from the skid. Pull the carton up off the unit. Be careful to avoid personal injury or equipment damage from staples which might be left in the carton walls.
The SSB- 3G/5G/10G steamers are equipped with
electronic controls. These units are readily identified
by their unique control panels. Steamer function is controlled by touch pad controls and a rotary timer dial.
The drain system on all models includes a spray condenser, which cools drain water.
Write down the model number, serial number and installation date. Keep this information for reference. Space for these entries is provided at the top of the Service Log in the back of this manual.
Inspection and Unpacking
240 109
310 141
475 215
272 123
345 156
555 252
SSB-3G 3 2 0 0
(2)SSB-3G 6 4 0 0
SSB-5G 5 3 0 0
(2)SSB-5G 10 6 0 0
SSB-10G 10 6 20 10
(2)SSB-10G 20 12 40 20
SSB
Steamer
12 x 20 x 2-1/2
(steamer)
12 x 20 x 4
(steamer)
13 x 18
(half size
bake)
18 x 26
(bake)
PANS PER CAPACITY PER TYPE
When starting installation, check packing materials to make sure loose parts such as the condensate drip tray are not discarded with this material.
SSB Steamer
Weight (LBS)
Weight (KGS)
SSB-3G Table Top
SSB-3G W/Stand
(2) SSB-3G W/Stand
SSB-5G Table Top
SSB-5G W/Stand
(2)SSB-5G W/Stand
SSB-10G W/Stand 452 205
(2)SSB-10G W/Stand 764 347
4 OM-SSB-G
1. Installation
Minimum Clearances:
SmartSteam100 Boilerless Steamer requires the following minimum clearances to any surface, combustible or non­combustible.
Right Side 2 inches Left Side 2 inches Rear 6 inches
Steam Free Zone
: The SmartSteam100 Boilerless Steamer can be damaged by steam from external sources. Do not install the steamer over a steam venting drain. Ensure that steam is not present in an area bounded by the footprint of the steamer and a circle 18 inches in radius about the right rear corner of the steamer (see
figure below).
Install and operate the gas appliance in a well ventilated area. Adequate air must be supplied to replenish the air used for combustion. Installation must conform with local codes and/or with the Naitonal Fuel Gas Code, ANSI Z223.1/NFPA-54 (latest edition) or the National Gas and Propane Code CSA B149.1 as applicable.
Any item which might obstruct or restrict the flow of air for combustion and ventilation must be removed. Do not obstruct the flue cover or rear vents after
THE AREA DIRECTLY AROUND THE APPLIANCE MUST BE CLEARED OF ALL COMBUSTIBLE MATERIAL. FAILURE TO FOLLOW THESE INSTRUCTIONS CAN CAUSE BODILY INJURY AND/OR PROPERTY DAMAGE.
The steamer must be disconnected from the gas supply system during any pressure testing of that system which has test pressures in excess of1/
2
PSI (3.45 kPa).
2. Electrical Supply Connection
Provide 115 VAC, 60 HZ, 1 PH, 15 AMP service. Bring wire in through hole in the lower left back panel. Each cavity requires a separate cord for connections. Local codes and/or the National Electrical Code should be observed in accordance with ANSI/NFPA 70. AN
ELECTRICAL GROUND IS REQUIRED.
The wiring diagram is located in the service compartment and in this manual. Maximum load is 21/2AMPs. In Canada, provide electrical service in accordance with the Canadian Electrical Code, CSA C22.2 Part 1 and/or local codes.
3. Gas Supply Connection
Connection to the gas supply shall be in accordance with the chart below.
OM-SSB-3G/5G/10GF
Installation and Startup
WARNING
THE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO WORK WITH GAS,
ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES. THE UNIT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN THE COMMONWEALTH OF MASSACHUSETTS.
CAUTION
DO NOT INSTALL THE UNIT WITH THE REAR VENTS BLOCKED OR WITHIN 2 INCHES OF A HEAT SOURCE SUCH AS A BRAISING PAN, DEEP FAT FRYER, CHARBROILER OR KETTLE.
TO AVOID DRAINAGE PROBLEMS, LEVEL THE UNIT FRONT TO BACK, AND PITCH SLIGHTLY TO
THE FRONT.
NPT Pipe Size Required
1
/
2
1
/
2
1
/
2
1
/
2
SSB-Steamer
SSB-3G
(2)SSB-3G
SSB-5G
(2)SSB-5G
3
/
4
3
/
4
SSB-10G
(2)SSB-10G
18 -inch
radius
SMARTSTEAM
(top view)
457 mm
OM-SSB-G 5
After the unit has been connected to the gas supply, all gas joints must be checked for leaks. Do NOT use flame checking for leaks. A thick soap solution or other suitable leak detector should be used.
For a Unit on casters:
A. The installation shall be made with a
connector that complies with the standard for connectors for movable gas appliances; ANSI Z21.69.CSA 6.16, and a quick­disconnect device that complies with the standard for quick-disconnect devices for use with gas fuel, ANSI Z21.41.CSA 6.9.
B. Adequate means must be provided to limit
the movement of the appliance without depending on the connector and the quick­disconnect device or its associated piping to limit the appliance movement.
C. The location where the restraining device
may be attached to the appliance shall be in acordance with Groen specifications for the device.
4. Water Connection(s)
Install a check valve to prevent back flow in the incoming cold water line, as required by local plumbing codes. Water pressure in the line should be between 30 and 60 PSI. If pressure is above 60 PSI, a pressure regulator will be needed. These pressures must provide the 1.5 gallons per
minute required for
proper steamer function.
A3/4inch female NH connector (garden hose type) is used to attach the water supply to the
inlet valve. Minimum inside diameter of the
water feed line is1/2inch. Use a washer in the
hose connection. Do not allow the connection to leak, no matter how slowly. Do not over-tighten hose connections.
This equipment is to be installed to comply
with the basic plumbing code of the Building Officials
and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA).
NOTE: Local code may also require check valves in the water supply line.
5. Drain Connection
Level the steamer front to back, and pitch it slightly to the rear (maximum1/4inch) by adjusting the optional legs or the bullet feet on the optional stand.
WARNING: DO NOT CONNECT THE DRAIN DIRECTLY TO A BUILDING DRAIN. BLOCKING THE DRAIN IS HAZARDOUS.
There must be a free air gap between the end of the hose and the building drain. The free air gap should be as close as possible to the unit drain. There must also be no other elbows or restrictions between the unit drain and the free air gap.
CAUTION DO NOT USE PLASTIC PIPE. DRAIN MUST BE RATED FOR BOIILING WATER.
Install the drain line with a constant downward pitch.
IMPORTANT: Do not allow water traps in the line. A trap can cause pressure in the cavity, which
may cause the door gasket to leak.
Proper Drain Line Connection –– Drain Line must have a constant downward pitch of at least
1
/4” per foot. Observe local code regarding air
gap spacing and drain connections.5.
In Canada, the installation must conform to the Canadian Gas Code, CAN 1-B149, Installation Codes for Gas Burning Appliances and Equipment and/or local codes.
Ratings for Gas SmartSteam100
*Measured on top of gas valve
*Operating
BTU Pressure
3G NG
3G LP
5G NG
5G LP
54,000
54,000
62,000
62,000
4.30” WC
10.5” WC
4.25” WC
10.5” WC
5” WC
12” WC
5” WC
12” WC
14” WC
14” WC
14” WC
14” WC
10G NG
10G LP
106,000
106,000
4.30” WC
10.5” WC
5” WC
12” WC
14” WC
14” WC
Drain ID Hose Size
Required (IN)
1.5”
2.5”
1.5”
2.5”
SSB-Steamer
SSB-3G
(2)SSB-3G
SSB-5G
(2
2.0”
2.0”
SSB-10G
(2)SSB-10G
)SSB-5G
6 OM-SSB-G
OM-SSB-3G/5G/10GF
6. Factory-Stacked Units
This section is applicable only if you are installing factory-stacked units.
Installing stacked steamers is similar to installing a single unit. The steamers are stacked and assembled at the factory and delivered with the water connections and drain hoses required for a single point connection.
A. Water Connection
The same water supply connection is used for both units. At the water inlet valve a3/4inch female NH connector (gardenhose type) isused for the water supply.
B. Electrical Supply Connection
Separate electrical connections will be required for each steamer to be stacked. Each steamer unit must have it’s own branch circuit protection.
C. Gas Connection
A single gas connection is required for both steamers. Gas supply must be adequate under all conditions as listed on page 6.
D. Drain Connection
Steamers must be leveled front to back, and pitched to the front (maximum 1/4inch) by adjusting the bullet feet on the cabinet or stand base.
For all factory-stacked SSB steamers, a 21/2inch ID hose is attached to the unit drain. It must be rated for boiling water.
7. Counter-Mounted Units
This section is applicable if the steamer will be mounted to a counter. All four edges of the bottom of the steamer must be sealed with RTV to the counter if the 4 inch legs are not used. Counter must be made of a noncombustible material such as metal or tile.
WARNING: DO NOT STACK SSB STEAMERS WHEN LEGS ARE USED.
OM-SSB-G 7
OM-SSB-3G/5G/10GF
Initial Startup
After the SmartSteam100 Boilerless Steamer has been installed, test it to ensure that the unit is operating correctly.
1. Remove all literature and packing materials from the interior and exterior of the unit.
2. Make sure the water supply line is open.
3. Make sure that the gas supply line is open
and that the manual knob on the main gas valve is turned to the ON position. This valve is at the rear on the right side of the unit.
4. Turn on electrical service to the unit. The steamer will not operate without electrical power. Do not attempt to operate the unit during a power failure.
NOTE: The door MUST be closed for the main burner to work.
5. To turn the unit on, press the ON switch on the control panel.
6. When the steam generating reservoir has filled with water, the main burners will ignite automatically. Within 20 minutes or less the R
EADY light will come on, indicating
that the water has reached its standby
temperature. When the READY light is displayed, you may take any one of the following steps;
a. Push TIMED and set the timer knob to the
desired steaming time.
b. Push MANUAL for continuous steaming.
c. Push STOP to let the unit stay at
ready condition.
WARNING WHEN YOU OPEN THE DOOR, STAY AWAY FROM STEAM COMING OUT OF THE UNIT. STEAM CAN CAUSE BURNS.
7. To shut down the unit, press the OFF switch.
The steam generating reservoir will then fill with cold water and drain.
8. If the steamer operates as described, the unit is functioning correctly and ready for USE.
NOTE: For operation at high altitudes (2000 feet and above), please consult the Groen Foodservice Engineering Department.
8 OM-SSB-G