GE
Sensing
DewPro MMR101
Specifications
Sensing Element
Polymer; capacitance
RH Range
0 to 100%
RH Accuracy
±2% up to 150°F (65°C)
Temperature Sensor
Platinum RTD
Temperature Accuracy
±2°F (±1.1°C)
Operating Temperature Range
Process: 32°F to 300°F (0°C to 150°C)
Electronics: -40°F to 185°F (-40°C to 85°C)
Maximum Operating Pressure
150 psi (10.2 bar)
Electronics
Microcontroller operated, loop-powered
Loop Power Supply
24 VDC nominal, 12 to 30 VDC range
Outputs
Two fully isolated 4 to 20 mA current loops (moisture and
temperature) patented (U.S. patent #5,677,476)
Hardware Selectable Units
0% to 100% RH, -40°F to 212°F or -40°C to 100°C dew
point (up to 320°F or 150°C under system pressure),
0 to 1000 g/m3absolute humidity, and 0 to 1000 g/kg
mixing ratio dry air, wet buld temperature, volume %
Standard Temperature Output
32°F to 300°F (0°C to 150°C) range
Optional Display
Four-digit numeric display with bar graph and matrix
position indication. Four user interface keys for unit
selections, output adjustments and ranging.
Protection
Type 4X/IP67
Probe Tube
16 in (400 mm) 316 stainless steel, 0.5 in diameter.
Adjustable insertion length from 3 in (80 mm) to 14.25 in
(362 mm). 9 in (225 mm) also available.
Typical Mounting Adapter
1/2 in tube x 1/2 in NPT-M or G 1/2 compression fitting;
flanges and other sizes available upon request
Sensor Guard
40 micron sintered filter, 316 stainless steel cap
Weight
4.4 lb (2 kg)
European Compliance
Complies with EMC Directive 89/336/EEC and
PED 97/23/EC for DN< 25
Optional Certification/Approvals
• FM IS Class I,II,III, Division 1, Groups A,B,C,D,E,F&G, T4
• FM XP-IS Class I, Division 1, Groups A,B,C&D, T5
• FM NI Class I, Division 2, Groups A,B,C&D, T4A
DIP Class II,III, Division 1, Groups E,F&G, T4
• ATEX II 3G EEx nA IIC T4
.50 in
(12.7 mm)
5.44 in (138.0 mm)
3.11 in
(79.0 mm)
AF 1.62 in
Epoxy-coated
cast aluminum
housing that
meets
Type 4X/IP67
requirements
M20 or 1/2 in
NPT conduit or
cable gland
5.06 in
(188.5 mm)
16.24 in
(412.4 mm)
©2005 GE. All rights reserved.
920-061A
All specifications are subject to change for product improvement without notice.
DewPro®is a registered trademark of GE. GE®is a registered trademark of General
Electric Co.
g
www.gesensing.com
DewPro MMR101 with optional display
Sintered end cap