GE Industrial Solutions Galaxy Manager User Manual

Galaxy Manager

User’s Guide Select Code 193-104-107 Comcode 108988201 Issue 4.3 Preliminary January 2004
User’s Guide Select Code 193-104-107 Comcode 108988201 Issue 4.3 Preliminary January 2004
Galaxy Manager
Notice:
The information, specifications, and procedures in this manual are subject to change without notice. Lineage Power assumes no responsibility for any errors that may appear in this document.
© 2008 Lineage Power All International Rights Reserved Printed in U.S.A.
Galaxy Manager

Table of Contents

1 Overview / Introduction
Customer Service Contacts 1 - 2
Customer Service, Technical Support,
Product Repair and Return, and Warranty Service 1 - 2 Customer Training 1 - 2 On-Line Power Systems Product Manuals 1 - 2 EasyView and Gateway Software 1 - 2
2 Specifications
3 User Screens
Intro Page 3 - 1 System Overview 3 - 3
Site Symbols 3 - 3 Managed Site Quick Links 3 - 4 Alarm Button 3 - 5 Screen Links 3 - 5 Site List Screen Link 3 - 6
System Information Page 3 - 6
Office Record 3 - 7 Reserve & Recharge Time 3 - 7 Trending 3 - 8 Gateway 3 - 9 Alarms 3 - 9
System Reports 3 - 10
Overview of All Sites 3 - 10 Canned Report - Capacity report 3 - 11 Generic Data Viewer 3 - 12
Active Alarms 3 - 13
Acknowledging Alarms 3 - 13
Alarm History 3 - 15
Print, Pie, and Bar 3 - 15
Engineering Tools 3 - 16 Reserve & Recharge Time Calculator 3 - 16
Office Temperature 3 - 17 End Cell Voltage 3 - 17 Plant Load 3 - 17
Issue 4.3 Preliminary January 2004 Table of Contents - 1
Galaxy Manager
Rectifier Capacity 3 - 17 Battery Strings 3 - 17 Hours of Reserve 3 - 17 Total Effective Reserve AH 3 - 17 Hours to 95% Recharge 3 - 18
Rectifier Recharge Factor 3 - 18 Cable Sizing Calculator 3 - 18 Lineage Power Website 3 - 20 Help 3 - 20
2 - Table of Contents Issue 4.3 Preliminary January 2004
Galaxy Manager

List of Figures

Figure 2-1: Gateway Networking Diagram 2 - 2
Figure 3-1: Gateway Manager Home Page 3 - 1
Figure 3-2: System Overview Screen 3 - 3
Figure 3-3: “Drilled Down” Lower Level Map 3 - 4
Figure 3-4: Gateway Manager Screen Links 3 - 5
Figure 3-5: Concord System Data 3 - 6
Figure 3-6: Galaxy Manager Trend Data 3 - 8
Figure 3-7: Galaxy Gateway Login from the Live Data Link 3 - 9
Figure 3-8: System Reports 3 - 10
Figure 3-9: Canned Report - Data Spreadsheet 3 - 10
Figure 3-10: Canned Report - Capacity Report 3 - 11
Figure 3-11: System Reports - Generic Data Viewer 3 - 12
Figure 3-12: Active Alarms 3 - 13
Figure 3-13: Acknowledge Alarms Screen 3 - 14
Figure 3-14: Alarm History Viewer 3 - 15
Figure 3-15: Battery Reserve Calculator 3 - 16
Figure 3-16: Cable Sizing Calculator, Centralized
Architecture 3 - 19
Figure 3-17: Cable Sizing Calculator, Distributed
Architecture 3 - 20
Issue 4.3 Preliminary January 2004 List of Figures - 1
Galaxy Manager

1 Overview / Introduction

Galaxy Manager enables the secure and timely management of geographically distributed power systems. Its graphical interface gives the user an intuitive view of the status of all sites and their systems on geographic maps. Continuously recorded site data as well as the system configuration are maintained in a relational database. Users can drill down through the maps or site listings to view specific equipment readings, print various reports, and interact with various graphical charts. At all times, the server is continuously monitoring for alarm conditions and status changes across the sites being managed. All collected data and monitored sites are also remotely accessible through the network from the Galaxy Manager, permitting password protected configuration changes and upgrades.
Alarm data for sites being monitored can be viewed from geographic regional maps, through a live alarm viewer. Past site alarms are also available in a history log. Several power management utilitiy tools are provided, including a system cable sizing tool and a battery reserve/ recharge time calculator that uses the data from a specific site and provides data for "what if" scenarios. Direct links to Lineage Power internet pages are also provided to permit easy access to product data sheets, manuals, and ordering guides. (External sites will not be accessible if the system is not connected to the Internet). Galaxy Manager is furnished by Lineage Power as a complete hardware and software package, requiring only a 10Base-T (RJ-45) physical connection to the user’s LAN/WAN intranet network. To be monitored by Galaxy Manager, equipment must be accessible on this intranet through one of the following:
• a Galaxy Gateway monitoring and control system
• a Galaxy Manager Portal
• another Galaxy Manager compatible data gathering unit.
This manual introduces Galaxy Manager and the views and controls it offers. Help and guidance with specific issues may be requested via an email to Lineage Power at galaxy.manager@lineagepower.com. Please be sure to include your return email address so that we may respond. Your suggestions and questions are welcomed so that we may continue to improve the product.
Issue 4.3 Preliminary January 2004 Overview / Introduction 1 - 1
Galaxy Manager
Recommended server configuration:
Main processor and processor speed: Intel-based CPU, 2 GHz Memory: 256 MB Number of hard drives / size: One 40 GB Operating system: Windows 2000 Professional or Server; Fedora Linux CD-ROM: CD-RW Network Card: 10/100 Mbs network interface card
Client requirements:
Microsoft Internet Explorer 6.0 or later Intranet connectivity Display: 1024 x 768 VGA (Recommended: 1280 x 1024) Optional: Sound card and speaker

Customer Service Contacts

Customer Service, Technical Support, Product Repair and Return, and Warranty Service

For customers in the United States, Canada, Puerto Rico, and the US Virgin Islands, call 1-800-THE-1PWR (1-800-843-1797). This number is staffed from 7:00 am to 5:00 pm Central Time (zone 6), Monday through Friday, on normal business days. At other times this number is still available, but for emergencies only. Services provided through this contact include initiating the spare parts procurement process, ordering documents, product warranty administration, and providing other product and service information.
For other customers worldwide the 800 number may be accessed after first dialing the AT&T Direct country code for the country where the call is originating, or you may contact your local field support center or your sales representative to discuss your specific needs.

Customer Training Lineage Power offers customer training on many Power Systems

products. For information call 1-972-284-2163. This number is answered from 8:00 a.m. until 4:30 p.m., Central Time Zone (Zone 6), Monday through Friday.

Downloads and Software

To download the latest product information, product software and software upgrades, visit our web site at http://www.lineagepower.com
1 - 2 Overview / Introduction Issue 4.3 Preliminary January 2004
Galaxy Manager

2 Specifications

A simplified depiction of a power management network is shown in Figure 2-1. The key components are the power systems, the remote users of the system, the server that manages the retrieval, storage and application tools that present and manipulate the data, and the network and protocols that allow everything to communicate. Galaxy Manager is the software manager and host system shown connected at the top of this network.
A complete monitoring package including a host system and the Galaxy Manager software is available. The Galaxy Manager host system consists of a dedicated PC / server for power network management. It is supplied by Lineage Power with the Galaxy Manager software and all appropriate business application tools pre-loaded. This system is fully configured and tested prior to shipping.
If only the Galaxy Manager software is ordered, the customer-provided server should meet the following minimum specifications:
Main processor and processor speed: Intel-based CPU, 2 GHz
Memory: 256 MB
Number of hard drives / size: One 40 GB
Operating system: Windows 2000 Professional or Server, or
UNIX (e.g. RedHat Version 9)
CD-ROM: CD-RW
Display: 17” diagonal, 1280 x 1024 resolution
16MB VGA or DVI with VGA adapter
Speaker: Internal audio speaker
Network Card: 10/100 Mbs network interface card
Issue 4.3 Preliminary January 2004 Specifications 2 - 1