ISBus interface board
for AV-300i Drives
INSTRUCTIONS
GE Industrial SystemsGE Industrial Systems
Page 2
These instructions do not purport to cover all details or variations in equipment, nor to provide every possible contingency to be met during installation, operation, and maintenance. If further information is desired or if particular problems arise that are not covered sufficiently for the purchaser’s purpose, the matter should be referred to GE Industrial Systems.
This document contains proprietary information of General Electric Company, USA and is furnished to its customer solely to assist that customer in the installation, testing, operation, and/or maintenance of the equipment described. This document shall not be reproduced in whole or in part nor shall its contents be disclosed to any third party without the written approval of GE Industrial Systems.
© 1999 by General Electric Company, USA. All rights reserved.
Page 3
Table of contents
1. HARDWARE DESCRIPTION .................................................... 4
1.1 MOUNTING .......................................................................................... 4
1.2. JUMPERS ............................................................................................. 5
1.3. LEDS ..................................................................................................... 5
1.4 DIMENSIONS AND WEIGHT ................................................................ 6
Page 4
GEI-100424

1. HARDWARE DESCRIPTION

1.1 MOUNTING

The ISBus card is supplied with standoffs, screws, washers and a ISBus connectors.
1 . Switch the drive off.
2. Fasten the ISBus card to the drive regulation board by means of screws (B) and standoffs (A). The SBI-Drive connector (C) must be connected between X0 (on Regulation board) and X0 (on ISBus card).
3 . Switch on the drive. 4 . The LED H1 lights up.
NOTE:
NOTE:
4
B
C
A
Tx Rx Tx
ISBus functionality requires A V300i software version 2.00 or higher
Refer to GEH 6380 for ISBus cabling and hookup.
—————— Expansion board ——————
Page 5
ISBus
NOTE:
Do not interchange generic ISBus and Ethernet cables with A V-300i keypad and SBI cables. Doing so will damage A V-300i components.

1.2. JUMPERS

S1 Reserved for internal test purpose; leave open.

1.3. LEDS

H1 _____________________ +5V power supply. H2 _____________________ 1.OFF – No modulation received.
2. One flash per second – receiving modulation, reset state.
3. Two flashes per second – offline state.
4. Three flashes per second – standby state.
5. Solid on - online.
H3 _____________________ data transfer in progress on ISBus when lit.
LEDs on connector Rx Tx (X1) function the same as LEDs H2 and H3. LEDs on X2 (Tx) connector have some functionality of the LEDs H2 - H3.
—————— Expansion board ——————
5
Page 6
GEI-100424

1.4 DIMENSIONS AND WEIGHT

88mm
145 mm
Rx TxTx
Dimensions_________________________________H=145 mm [5.7 “], L = 88
[3.4“] , D = 27.5 [1 “] Weight_____________________________________79 g [2.78 oz] Degree of protection__________________________IP00 +24V Power requirements______________________ 100 mA average, 190 mA max
Refer to GEH 6380 for ISBus cabling construction to connectors RxTx (X1) and Tx (X2)
6
—————— Expansion board ——————
Page 7
Page 8
ISBus GEI-100424 10/99
Rev. 0.0 / 12.10.99
We bring good things to life.