LME LOWMOUNT ® II LUMINAIRE
NUVATION ™ Electronic Ballast
Low Bay Enclosed – Optical Sliding Disconnect Series
APPLICATIONS
• For 10-25 ft. (3-8 meter) applications in factories, canneries, textile, metal, chemical,
rubber, food, cement and other industrial applications.
SPECIFICATION FEATURES:
• 1598 Listed
Suitable for Damp Location
• 1598 Listed for metal halide lamps in polymeric
lamp containment barriers.
• Enclosed and gasketed optical
• Charcoal ltered optics
• UV stabilized injection molded prismatic
refractor for low brightness
• Alzak nish on reector.
• Stick relampable via access door
• 55° C ambient, standard
• Nuvation ™ electronic ballast:
• Dimming Option — dims lamp to 50% of rated
lamp wattage.
• Two piece heavy-duty die cast aluminum housing
• Integral optical mounting design for GELS
“Sliding Disconnect”
ORDERING NUMBER LOGIC
LME
PRODUCT
IDENT
XXX
LME =
Lowmount
II
Disconnect
Luminaire
with
NnVation
electronic
ballast
W
COLOR
X
W =
White
Polyester
Powder
40
WATTAGE
XX
25 = 250
32 = 320
35 = 350
40 = 400
N
LIGHT
SOURCE
X
E =
Energy
Act
Compliant
Pulse MH
N =
Ballast will
operate
Pulse
Start or
Ceramic
Metal
Halide
Lamps
Note:
Lamp is
vertical
base up.
Lamp
is not
included.
PHOTOMETRIC SELECTION TABLE
EA, EP OPTICAL - Enclosed Acrylic/Polycarbonate with Trap Door
Light Socket Photometric Optical Photometry
Wattage Source Position Curve Code Code
400 MH 2.1 177129 EA VE
320, 350 P (MH) 2.1 177129 EA VE
400 P (MH) 2.1 177129 EA VE
Note: Lexan, Polycarbonate lens reduce light levels by 10%
Note: See page T-34 of Product Selection Guide, GEA-12000, for Alternative
lens material explanation
Note: Lexan is a registered Trademark of GE Plastic
G
VOLTAGE
X
G = 208-277
Discrete
Voltages
must be
specied
when
ordering
cord & plug
assemblies:
2 = 208
3 = 240
4 = 277
E
BALLAST
TYPE
X
E=
Electronic
C=
Dimming
EA
OPTICAL
CODE
XX
EA =
Enclosed
Acrylic
w/Trap Door
VE
PHOTOMETRY
CODE
XX
VE = Fixed
• Attractive round ballast housing
design with white polyester paint nish
• Integral air gap between optical
mounting and ballast for optimum
temperature control and thermal
management
• Slide-on mounting box adaptor with
3/4-in pendant and thru feed capability
for ease of installation and mounting.
• External wattage selection port for
selection of 250, 320, 350 & 400 watt
choices.
• Safety chain provisions
• Mogul base socket – E39 standard
• Shipped as components: Ballast, Optical.
Magnapack available for ballast.
11
MOUNTING
CODE
XX
11= Pendant Slide on Box
15 = Prewire with Loop, Cord and Plug part “Power
Hook”. (Order Receptacle/Hook Box separately)
Discrete Voltages must be specied when ordering
cord & plug assemblies below:
31 = Prewired with Hook, 3 ft. (0.9 meters) #16/3 Cord
and NEMA PLUG
33 = Prewired with Loop, 3 ft. (0.9 meters) #16/3 Cord
and NEMA PLUG (Order Locking Receptacle
Separately, if required)
MODULAR PREWIRE
41 = ACS with 3 ft (.9 meter) cord & Hook
69 = ACS with 6 ft (1.8 meter) cord & Hook
43 = ACS with 3 ft (.9 meter) cord & Loop
70 = ACS with 6 ft (1.8 meter) cord & Loop
PLUG-N-GO
51 = Plug-N-Go with 3 ft. (0.9 meter) Cord & Hook
71 = Plug-N-Go with 6 ft. (1.8meter) Cord & Hook
53 = Plug-N-Go with 3 ft. (0.9 meter) Cord & Loop
72 = Plug-N-Go with 6 ft. (1.8 meter) Cord & Loop
Note: ACS = Flex 3+
Plug-N-Go = FSC Series
All Electronic devices are susceptible to transient voltage spikes. For facilities
where the lighting circuits are not protected from transient voltage spikes
a (TVSS) Transient Voltage Surge Suppression system is recommended.
To protect the NuVation ballast a T VS protection system must be able to
suppress a 3000V ring wave as described in ANSI/IEEE C62.41 B1.
X
OPTIONS
X
Q = Automatic
switched quartz
S = Exclusionary
mogul base socket
for MH open xtures
W = Wet Location
(Available for use with
Mountings 11 and 15
only)
I-24/2008
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
LME LOWMOUNT
NUVATION
® II LUMINAIRE
™
Electronic Ballast
Low Bay Enclosed – Optical Sliding Disconnect Series
DIMENSIONS
When optical assembly contains a quartz socket an additional
1.125 inches (29mm) must be added to the overall height due to
double stack disconnect.
NOTES
See explanation on “Optical Flexibility” Page I-4. See References.
REFERENCES
See Page I-104 for start of Accessories.
See Page I-117 for Component Ordering Logic.
See Page I-129 for Explanation of Options and Other Terms Used.
3/4 in. NPSC
Thread
FIXTURE DIMENSIONS
15.00 in. Dia.
(381mm)
Fixture Height
28.55 in.
(725mm)
29.98 in. Dia. (761mm)
DATA
Approximate Net Weight lbs kgs
Ballast and Optical 23-33 10-15
BALLAST DATA
* 13% Improvement in Pulse Start Metal Halide lamp lumen maintenance vs. magnetic.
* 6% improvement in Ceramic Metal Halide lamp lumen maintenance vs. magnetic.
* 50% lower ballast losses than typical CWA magnetic HID ballast.
* Lamp wattage regulation of +/-2% change for +/-10% change in line voltage.
* Ballast is rated for use with voltage range between 208 and 277 with +/-10% line voltage tolerance, 50/60 Hz, and will
automatically sense voltage within specied range.
* Ballast input current total harmonic distortion (THD) of less than 15% when operated at nominal line voltage.
* Ballast is thermally protected to shut o when operating temperatures are
above unacceptable levels for the ballast safe and reliable operation.
* Ballast has an end-of-lamp-life detection and shutdown circuit.
* The ballast shall have a minimum starting temperature of –20 degrees F
and maximum operating ambient of 55 degrees C..
* Ballast is capable of operating pulse start metal halide or ceramic metal halide lamp types.
* Five-Year Fixture Failure Warranty.
* Meets requirements of FCC rules and regulations, Title 47 CFR part 18 for nonconsumer equipment.
Dimming Ballast
* The ballast is supplied with a violet (+) and gray (-) wire for dimming control connections.
* Ballast dims to fty percent of rated lamp wattage.
* Dimming voltage is 0-10V where 10V is high wattage and 0 is fty percent of rated lamp wattage.
* Ballast operates the lamp at high wattage for 15 minutes at start up.
* Ballast operates lamp at high wattage for fteen minutes after operating in dim mode for twenty-four hours.
Relamp Access Door
INPUT WATTAGE TABLE
Lamp Line Input
Wattage Voltage Watts
400 277 428
400 240 432
400 208 435
350 277 377
350 240 380
350 208 383
320 277 346
320 240 347
320 208 349
250 277 276
250 240 272
250 208 271
® Registered Trademark of General Electric Company
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
TM
Trademark of General Electric Company
Data subject to change without notice
2008/I-25