Frymaster J1X, J2X Master Jet Operation Manual

Installation, Operation, Service, and Parts Manual
J1C, J1X, and J2X Master Jet
Series Gas Fryers
PRINTED IN THE USA
service@frymaster.com
Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.
1-800-551-8633
www.frymaster.com
NOVEMBER 2009
* 8 1 9 6 5 1 3 *
NOTICE
This appliance is intended for professional use only and is to be operated by qualified
personnel only. A Frymaster and DEAN Authorized Service Agent (ASA) or other qualified
professional should perform installation, maintenance, and repairs. Installation, maintenance,
or repairs by unqualified personnel may void the manufacturer’s warranty. See Chapter 1 of
this manual for definitions of qualified personnel.
NOTICE
This equipment must be installed in accordance with the appropriate national and local codes of
the country and/or region in which the appliance is installed. See NATIONAL CODE
REQUIREMENTS in Chapter 2 of this manual for specifics.
NOTICE TO U.S. CUSTOMERS This equipment is to be installed in compliance with the basic plumbing code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation
Manual of the U.S. Food and Drug Administration.
NOTICE
Drawings and photos used in this manual are intended to illustrate operational, cleaning and
technical procedures and may not conform to onsite management operational procedures.
NOTICE TO OWNERS OF UNITS EQUIPPED WITH COMPUTERS
U.S.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. While this device is a verified Class A device, it has been shown to meet the Class B limits.
CANADA
This digital apparatus does not exceed the Class A or B limits for radio noise emissions as set out by the ICES-003 standard of the Canadian Department of Communications.
Cet appareil numerique n’emet pas de bruits radioelectriques depassany les limites de classe A et B prescrites dans la norme NMB-003 edictee par le Ministre des Communcations du Canada.
DANGER
Improper installation, adjustment, maintenance or service, and unauthorized alterations or
modifications can cause property damage, injury, or death. Read the installation, operating,
and service instructions thoroughly before installing or servicing this equipment. Only qualified
service personnel may convert this appliance to use a gas other than that for which it was
originally configured.
DANGER
No structural material on the fryer should be altered or removed to accommodate placement of
the fryer under a hood. Questions? Call the Frymaster/Dean Service Hotline at 1-800-551-8633.
DANGER
Adequate means must be provided to limit the movement of this appliance without depending
upon the gas line connection. Single fryers equipped with legs must be stabilized by installing
anchor straps. All fryers equipped with casters must be stabilized by installing restraining
chains. If a flexible gas line is used, an additional restraining cable must be connected at all
times when the fryer is in use.
DANGER
The front ledge of the fryer is not a step! Do not stand on the fryer. Serious injury can result
from slips or contact with the hot oil.
DANGER
Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any
other appliance.
DANGER
Instructions to be followed in the event the operator smells gas or otherwise detects a gas leak
must be posted in a prominent location. This information can be obtained from the local gas
company or gas supplier.
DANGER
The crumb tray in fryers equipped with a filter system must be emptied into a fireproof container
at the end of frying operations each day. Some food particles can spontaneously combust if left
soaking in certain shortening material.
WARNING
Do not bang fry baskets or other utensils on the fryer’s joiner strip. The strip is present to seal
the joint between the fry vessels. Banging fry baskets on the strip to dislodge shortening will
distort the strip, adversely affecting its fit. It is designed for a tight fit and should only be
removed for cleaning.
NOTICE
IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS
EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED
DIRECTLY FROM FRYMASTER/DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS,
AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS
WARRANTY WILL BE VOID. FURTHER, FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE
LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH
ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF
ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE CENTER.
RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.
J1C, J1X, & J2X Master Jet Series Atmospheric Gas
Fryers
TABLE OF CONTENTS
PAGE #
CHAPTER 1: General Information
1.1 Parts Ordering and Service Information........................................................................................................ 1-1
1.2 Safety Information ........................................................................................................................................ 1-1
1.3 Equipment Description.................................................................................................................................. 1-2
1.4 Installation, Operating, and Service Personnel.............................................................................................. 1-2
1.5 Definitions..................................................................................................................................................... 1-3
1.6 Shipping Damage Claim Procedure .............................................................................................................. 1-3
CHAPTER 2: Installation Instructions
2.1 General Installation Requirements................................................................................................................ 2-1
2.2 Leg Installation ............................................................................................................................................. 2-3
2.3 Pre-Connection Preparations......................................................................................................................... 2-3
2.4 Connection to Gas Line................................................................................................................................. 2-4
2.5 Converting to Another Gas Type .................................................................................................................. 2-7
CHAPTER 3: Operating Instructions
3.1 Start-Up Procedure........................................................................................................................................ 3-1
3.2 Boiling-Out the Frypot.................................................................................................................................. 3-3
3.3 Shutting Down the Fryer............................................................................................................................... 3-4
CHAPTER 4: Filtration Instructions........................................................................................................................... 4-1
CHAPTER 5: Preventive Maintenance
5.1 Fryer Preventive Maintenance Checks and Services..................................................................................... 5-1
5.2 Annual/Periodic System Inspection .............................................................................................................. 5-4
CHAPTER 6: Operator Troubleshooting
6.1 Introduction................................................................................................................................................... 6-1
6.2 Troubleshooting Thermostat Controlled Fryers............................................................................................ 6-1
6.3 Troubleshooting Abnormal Burner Operation .............................................................................................. 6-2
CHAPTER 7: Service Procedures
7. Service Procedures Reference Picture (Figure 1).......................................................................................... 7-1
7.1 Replace Controlling or High-Limit Thermostat............................................................................................ 7-2
7.2 Calibrating a Thermostat after Installation.................................................................................................... 7-2
7.3 Replace the Pilot Generator Cartridge........................................................................................................... 7-3
7.4 Adjust the Pilot Flame................................................................................................................................... 7-3
7.5 Burner Gas Pressure Adjustment .................................................................................................................. 7-4
7.6 Replacing the Gas Valve....................................................................................................
7.7 Removing the Main Burner Assembly.......................................................................................................... 7-5
7.8 Replacing a Burner Deflector........................................................................................................................ 7-5
7.9 Alignment and Adjustment of Burner Deflector Assemblies........................................................................ 7-6
7.10 Replacing the Frypot..................................................................................................................................... 7-6
CHAPTER 8: Service Parts
8.1 Main Components......................................................................................................................................... 8-1
8.2 Frypot Components....................................................................................................................................... 8-2
8.3 Burner Components ...................................................................................................................................... 8-4
8.4 Accessories ................................................................................................................................................... 8-6
8.5 Thermostat Components ............................................................................................................................... 8-7
........................... 7-4
FRYMASTER DOMESTIC WARRANTY
WHAT IS COVERED
This warranty covers all defects in workmanship and material in all commercial cooking appliances and computer/controller equipment manufactured by Frymaster and sold within the domestic United States, except as excluded below.
WHO IS COVERED
This warranty covers only the original purchaser of Frymaster commercial cooking appliances and computer/controller equipment. This warranty is not trans­ferable. You must have your original sales receipt for warranty coverage.
WHAT WE WILL DO
We will repair or replace the defective appliance, component, or part. Such repair or replacement will be at the expense of Frymaster, LLC; except that travel over 100 miles or two hours, overtime, and holiday charges will be at the expense of the purchaser.
FRYPOT WARRANTY
Stainless steel frypots on all fryers, except as noted below, are warranted against manufacturing defects and/or weld seam failure for the lifetime of the fryer; parts and labor, except after one year, the warranty is limited to replacement parts. Stainless frypots for models listed below are warranted for the length of time indicated.
5 Years 7 Years 10 Years GF14, GF40 H55 (Effective Pasta Systems May 1, 1998) (Gas and Electric) Gas Protector Rethermalizer Water Bath Station (Gas and Electric)
H55 and gas Protector® combustion chamber (infrared burners and structural components to mount the burners) warranted against defective material or workmanship for 7 years, parts and labor.
FENWAL THERMOSTATS
Warranted for two years, parts and labor, except after one year, the warranty is limited to replacement parts.
OTHER PARTS
All other parts components are warranted for one year from the date of purchase (parts and labor).
SHORTENING DISPOSAL UNIT
Warranted for 90 days parts and labor. In addition, the pump is warranted for one year, parts only.
REPLACEMENT PARTS AND DROP-IN FRYERS (J1X & J2X)
Parts, 90 days, no labor Mild steel frypot, 90 days, no labor Stainless Steel frypots, 1 year, 90 days labor Computers, 1 year, no labor
HOW TO GET SERVICE
Contact our Authorized Service Agent to obtain warranty service. To find the name and location of the nearest ASA call your dealer, or call the Frymaster Service Hotline, 800-551-8633. You can also go to the Frymaster website, www.frymaster.com, click on Service, click on Locator, key in zip code and it will give you the ASA for that zip code. When calling for service, please furnish the model number, serial number, series code number, voltage of your appliance, and a description of the problem. You must keep your sales receipt for proof of your date of purchase.
WHAT THIS WARRANTY DOES NOT COVER
THE WARRANTIES PROVIDED BY FRYMASTER, LLC DO NOT APPLY IN THE FOLLOWING INSTANCES:
+ Damage due to misuse, abuse, alteration, or accident. + Improper or unauthorized repair. + Failure to follow installation procedures, operation instructions and/or scheduled maintenance procedures as prescribed in your Frymaster
+ Damage in shipment. + Removal, alteration, or obliteration of the rating plate. + Changes in adjustment and calibrations after thirty (30) days from equipment installation date. + Failure to program computer appliances in accordance with programming procedures prescribed in your Frymaster Service and Owner’s Manual. + Equipment exported to foreign countries. + Normal maintenance items such as electric bulbs, fuses, gaskets, o-rings, interior and exterior finishes. + Travel over 100 miles or two hours, overtime or holiday charges; all of which must be paid for by the purchaser. + Consequential damages (the cost of repairing other property which is damaged), loss of time, profits, use or any other non-fryer related inciden-
Service and Owner’s Manual.
tal damages of any kind.
GENERAL EXCLUSIONS No warranty is provided for any Frymaster fryer used in a mobile installation or concession. Warranty protection is only offered for fryers installed in
accordance with the procedures described in the Frymaster Service and Owner’s Manual. Drop-in units, such as J1X and J2X, receive parts warranty only.
There are no implied warranties of merchantability of fitness for any particular use or purpose. This warranty is the only and complete statement with respect to warranties of your commercial cooking appliances and computer/controller equipment manufactured by Frymaster. There are no other documents or oral statements for which Frymaster will be responsible.
www.frymaster.com Frymaster Domestic
J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
CHAPTER 1: INTRODUCTION
1.1 Parts Ordering and Service Information
In order to assist you as quickly as possible, the Frymaster Authorized Service Agency (ASA) or Service Department representative requires certain information about your equipment. Most of this information is printed on a data plate affixed to the inside of the fryer door.
Parts orders must be placed directly with your local ASA or distributor. Included with fryers when shipped from the factory is a list of Frymaster ASAs. If you do not have access to this list, contact the Frymaster Technical Service Department at 1-800-551-8633 or 1-318-865-1711.
When ordering parts, the following information is required:
Model Number: Serial Number: Type of Gas or Voltage: Item Part Number: Quantity Needed:
Service information may be obtained by contacting your local ASA. Information may also be obtained by calling the Frymaster Technical Service Department at 1-800-551-8633 or 1-318-865-
1711.
When requesting service, please have the following information ready:
Model Number: Serial Number: Type of Gas:
In addition to the model number, serial number, and type of gas, please be prepared to describe the nature of the problem and have ready any other information that you think may be helpful in solving your problem.
1.2 Safety Information
Before attempting to operate your unit, read the instructions in this manual thoroughly.
Your fryer is equipped with a high limit thermostat, which detects high temperatures and shuts off gas to the burner assembly should the controlling thermostat fail.
Additionally, J2X fryers are equipped with a safety switch built into the drain valve to prevent burner ignition while the drain valve is open.
Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the ones below.
1-1
J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
CHAPTER 1: INTRODUCTION
CAUTION
CAUTION boxes contain information about actions or conditions that may cause or result in a
malfunction of your system.
WARNING
WARNING boxes contain information about actions or conditions that may cause or result in
damage to your system, and which may cause your system to malfunction.
DANGER
DANGER boxes contain information about actions or conditions that may cause or result in injury to personnel, and which may cause damage to your system and/or cause your system to
malfunction.
1.3 Equipment Description
J1C, J1X, and J2X Master Jet Series gas fryers are designed for all-purpose frying applications. They come equipped with thermostat controllers for controlling the temperature of cooking cycles.
J1C Series gas fryers are tabletop fryers designed for limited space and all-purpose frying. J1C frypot capacity is 15-20 pounds.
J1X and J2X Series gas fryers are drop-in units designed for limited space and all-purpose frying. J1X frypot capacity is 15-20 pounds. J2X frypot capacity is 30-40 pounds. The J2X is equipped with a drain safety switch.
All three models are of an open-pot design and have a hand-sized opening into the deep cold zone, which makes cleaning the stainless frypot quick and easy. All fryers are shipped with a package of standard accessories. Each fryer is adjusted, tested, and inspected at the factory before crating for shipment.
Frypots are constructed of welded, heavy-gauge stainless steel. Heating is supplied by a burner assembly having multiple gas jets, which are focused on metal targets located around the lower side of the frypot. The burner assembly can be configured for natural gas, propane, or manufactured gas. The frypot is drained with a manual ball valve.
Master Jet Series Atmospheric fryers are equipped with a thermostat probe for precise temperature control. The probe is located on the centerline of the frypot for rapid response to changes in loads and to provide the most accurate temperature measurement.
1.4 Installation, Operating, and Service Personnel
Operating information for Frymaster equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.6.
All installation and service on Frymaster equipment must be performed by qualified, certified, licensed, and or/authorized installation or service personnel, as defined in Section 1.6.
1-2
J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
CHAPTER 1: INTRODUCTION
1.5 Definitions
QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL
Qualified/authorized operating personnel are those who have carefully read the information in this manual and have familiarized themselves with the equipment functions, or who have had previous experience with the operation of the equipment covered in this manual.
QUALIFIED INSTALLATION PERSONNEL
Qualified installation personnel are individuals, or firms, corporations, or companies, which, either in person or through a representative, are engaged in and are responsible for the installation of gas­fired appliances. Qualified personnel must be experienced in such work, be familiar with all gas precautions involved, and have complied with all requirements of applicable national and local codes.
QUALIFIED SERVICE PERSONNEL
Qualified service personnel are those that are familiar with Frymaster equipment and who have been authorized by Frymaster, L.L.C. to perform service on Frymaster equipment. All authorized service personnel are required to be equipped with a complete set of service and parts manuals, and to stock a prescribed minimum amount of Frymaster equipment parts.
A list of Frymaster Authorized Service Agencies (ASA) was included with the fryer when it was shipped from the factory. Failure to use qualified service personnel will void the Frymaster Warranty on your equipment.
1.6 Shipping Damage Claim Procedure
Your Frymaster equipment was carefully inspected and packed before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the equipment for transport.
What to do if your equipment arrives damaged:
1. File a claim for damages immediately, regardless of the extent of damages.
2. Inspect for and record all visible loss or damage, and ensure that this information is noted on
the freight bill or express receipt and is signed by the person making the delivery.
3. Concealed loss or damage that was unnoticed until the equipment was unpacked should be
recorded and reported to the freight company or carrier immediately upon discovery. A concealed damage claim must be submitted within 15 days of the date of delivery. Ensure that the shipping container is retained for inspection.
FRYMASTER L.L.C. DOES NOT ASSUME RESPONSIBILITY FOR
DAMAGE OR LOSS INCURRED IN TRANSIT.
1-3
J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
CHAPTER 2: INSTALLATION INSTRUCTIONS
2.1 General Installation Requirements
Qualified, licensed, and/or authorized installation or service personnel, as defined in Section
1.6 of this manual, should perform all installation and service on Frymaster equipment.
Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and/or authorized installation or service personnel as defined in Section 1.6 of this manual.
Failure to use qualified, licensed, and/or authorized installation or service personnel (as defined in Section 1.6 of this manual) to install, convert, to another gas type or otherwise service this equipment will void the Frymaster warranty and may result in damage to the equipment or injury to personnel.
Where conflicts exist between instructions and information in this manual and local or national codes or regulations, installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed.
DANGER
Building codes prohibit a fryer with its open tank of hot oil being installed beside an
open flame of any type, including those of broilers and ranges.
Upon arrival, inspect the fryer carefully for visible or concealed damage. (See Shipping Damage Claim Procedure in Chapter 1.)
DANGER
Frymaster appliances equipped with legs are for stationary installations. Appliances
fitted with legs must be lifted during movement to avoid damage to the appliance
and bodily injury. Questions? Call 1-800-551-8633.
PROPER INSTALLATION IS ESSENTIAL FOR EFFICIENT, TROUBLE-FREE OPERATION OF YOUR FRYER. ANY UNAUTHORIZED ALTERATIONS MADE TO THIS EQUIPMENT WILL VOID THE FRYMASTER WARRANTY.
Upon arrival, inspect the fryer carefully for visible or concealed damage. (See Shipping Damage Claim Procedure in Chapter 1.)
2-1
J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
CHAPTER 2: INSTALLATION INSTRUCTIONS
2.1 General Installation Requirements (cont.)
CLEARANCE AND VENTILATION
DANGER
No structural material on the fryer should be altered or removed to accommodate
placement of the fryer under a hood. Questions? Call the Frymaster/Dean Service
Hotline at 1-800-551-8633.
DANGER
This appliance must be installed with sufficient ventilation to prevent the occurrence
of unacceptable concentrations of substances harmful to the health of personnel in
the room in which it is installed.
The fryer(s) must be installed with a 6" (150 mm) clearance at both sides and back when installed adjacent to combustible construction; no clearance is required when installed adjacent to noncombustible construction. A minimum of 24" (600 mm) clearance should be provided at the front of the fryer.
An important consideration of efficient fryer operation is ventilation. Ensure the fryer is installed so flue gas is removed efficiently and the kitchen ventilation system does not produce drafts that interfere with proper burner operation.
The fryer flue opening must not be placed close to the intake of the exhaust fan, and the fryer must never have its flue extended in a "chimney" fashion. An extended flue changes the combustion characteristics of the fryer, causing longer recovery time. It also frequently causes delayed ignition. To provide the airflow necessary for good combustion and burner operation, the areas surrounding the fryer front, sides, and rear must be kept clear and unobstructed.
Fryers must be installed in an area with an adequate air supply and adequate ventilation. Adequate distances must be maintained from the flue outlet of the fryer to the lower edge of the ventilation filter bank. Filters should be installed at an angle of 45 degrees. Place a drip tray beneath the lowest edge of the filter. For U.S. installation, NFPA standard No. 96 states, "A minimum distance of 18 inches (450 mm) should be maintained between the flue outlet and the lower edge of the grease filter." Frymaster recommends that the minimum distance be 24 inches (600 mm) from the flue
outlet to the bottom edge of the filter when the appliance consumes more than 120,000 BTU per hour.
Information on construction and installation of ventilating hoods can be found in the NFPA standard cited above. A copy of the standard may be obtained from the National Fire Protection Association, Battery March Park, Quincy, MA 02269.
2-2
J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
CHAPTER 2: INSTALLATION INSTRUCTIONS
2.1 General Installation Requirements (cont.)
NATIONAL CODE REQUIREMENTS
The type of gas for which the fryer is equipped is stamped on the data plate attached to the inside of the fryer door. Connect a fryer stamped "NAT" only to natural gas, those stamped "PRO" only to propane gas, and those stamped "MFG" only to manufactured gas.
Installation shall be made with a gas connector that complies with national and local codes. Quick­Disconnect devices, if used, shall likewise comply with national and local codes.
2.2 Leg Installation
DANGER
DO NOT install this appliance without legs.
Depending upon the specific configuration ordered, the fryer might have been shipped without installed legs. If legs are installed, you may skip this section and proceed to Section 2.3, Pre­Connection Preparations.
If your fryer requires the installation of legs, install them in accordance with the instructions included in your accessory package.
2.3 Pre-Connection Preparations
DANGER
Do not connect this appliance to the gas supply before completing each step in this
section.
DANGER
Do not attach an apron drain board to a single fryer. The fryer may become
unstable, tip over, and cause injury. The appliance area must be kept free and clear
of combustible materials at all times.
After the fryer has been positioned under the fry station exhaust hood, ensure the following has been accomplished:
1. Level fryers equipped with legs by screwing out the legs approximately 1 inch, and then
adjust them so that the fryer is level and at the proper height in the exhaust hood. Frymaster recommends that the minimum distance from the flue outlet to the bottom edge of the filter be 24 inches (600 mm) when the appliance consumes more than 120,000 BTU per hour.
2-3
J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
CHAPTER 2: INSTALLATION INSTRUCTIONS
2.3 Pre-Connection Preparations (cont.)
2. Refer to the data plate on the inside of the fryer door to verify that the fryer burner is
configured for the proper type of gas before connecting the gas line quick-disconnect device or piping from the gas supply line.
3. Verify the minimum and maximum gas supply pressures for the type of gas to be used in
accordance with the accompanying tables:
Standard Incoming Gas Pressure
for J1C, J1X, and J2X
Gas
Natural
LP
Minimum
(J1C/J1X)
6" W.C.
1.5 kPa
15 mbar
10" W.C.
2.5 kPa
25 mbar
Maximum (J1C/J1X)
14" W.C.
3.49 kPa
34.9 mbar 14" W.C.
3.49 kPa
34.9 mbar
Minimum
(J2X)
6" W.C.
1.5 kPa
15 mbar
11" W.C.
2.74 kPa
27.4 mbar
Maximum
(J2X)
14" W.C.
3.49 kPa
34.9 mbar 14" W.C.
3.49 kPa
34.9 mbar
2.4 Connection to Gas Line
DANGER
Before connecting new pipe to this appliance, the pipe must be blown out
thoroughly to remove all foreign material. Foreign material in the burner and gas
controls will cause improper and dangerous operation.
DANGER
When pressure-testing incoming gas supply lines, disconnect the fryer from the gas
line if the test pressure will be ½ PSIG (3.45 kPa, 13.84 inches W.C.) or greater to
avoid damage to the fryer’s gas tubes and gas valve(s).
2-4
J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
CHAPTER 2: INSTALLATION INSTRUCTIONS
The size of the gas line used for installation is very important. If the line is too small, the gas pressure at the burner manifold will be low. This may cause slow recovery and delayed ignition. The incoming gas supply line should be a minimum of ½" (13 mm) in diameter. Refer to the chart below for the minimum sizes of connection piping.
Gas Connection Pipe Sizes
(Minimum incoming pipe size should be ½" (13 mm))
Gas
Connecting Pipe Size
(J1C/J1X)
Connecting Pipe Size
(J2X)
Natural ¾" (19 mm) ¾" (19 mm)
LP/Propane ½" (13 mm) ½" (13 mm)
Manufactured 1" (25 mm) 1" (25 mm)
1. Connect the quick-disconnect hose to the fryer quick-disconnect fitting under the front of the
fryer and to the building gas line.
NOTE: Some fryers are configured for a rigid connection to the gas supply line. These units are connected to the gas supply line at the rear of the unit.
When using thread compound, use very small amounts on male threads only. Use a pipe thread compound that is not affected by the chemical action of LP gases (Loctite PST567 sealant is one such compound). DO NOT apply compound to the first two threads. Applying compound to the first two threads will cause clogging of the burner orifices and control valve.
2. Open the gas-supply valve to the fryer and check all piping, fittings, and gas connections for
leaks. A soap and water solution should be used for this purpose.
2-5
J1C, J1X, & J2X MASTER JET SERIES GAS FRYERS
CHAPTER 2: INSTALLATION INSTRUCTIONS
DANGER
All connections must be sealed with a joint compound suitable for the gas being
used and all connections must be tested with a solution of soapy water before
lighting any pilots.
Never use matches, candles, or any other ignition source to check for leaks. If gas
odors are detected, shut off the gas supply to the appliance at the main shut-off
valve and immediately contact the local gas company or an authorized service
agency for service.
3. Close the fryer drain valve and fill the frypot with water and boil-out solution to the bottom OIL­LEVEL line at the rear of the frypot. Light the fryer and perform the boil-out procedures that are
described in the "Lighting Instructions" and "Boiling Out the Frypot" topics found in Chapter 3 of this manual.
DANGER
"Dry-firing" your unit will cause damage to the frypot and can cause a fire. Always
ensure that melted shortening, cooking oil, or water is in the frypot before firing your
unit.
4. The burner manifold pressure should be checked at this time by the local gas company or an authorized service agent. The tables below indicate the proper burner manifold pressures:
Standard Burner Manifold
Gas Pressure for J1C, J1X, and J2X
Gas Pressure – J1C & J1X Pressure – J2X
4" W.C.
Natural
LP
1.0 kPa
10 mbar
10" W.C.
2.5 kPa
25 mbar
5. Check the thermostat calibration according to the Thermostat Calibration instructions in Chapter 5.
3" W.C. .75 kPa
7.5 mbar
8.25" W.C.
2.0 kPa
20 mbar
2-6
Loading...
+ 30 hidden pages