Franke FUJI FFPD20400, FUJI FFPD20480 Installation Manual

LIMITED LIFETIME WARRANTY
All faucets installed in a private residence will carry a limited lifetime warranty on all mechanical parts to be free of manufacturing defects in material and workmanship under normal usage. All chrome finishes carry a limited lifetime warranty; all other finishes are warranted for five (5) years from the original date of purchase.
Marine and Outdoor Installation
warranted for Marine and Outdoor installations.
The Franke warranty is limited to the above conditions and to the warranty period specified herein and is exclusive. Franke DISCLAIMS all other warranties, expressed or implied, including IMPLIED WARRANTIES OF MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE. This warranty gives you specific legal rights that may vary from state to state.
Further information
For any further information about our products, about the installation of
REV.0 02/2016
AC92IST555LL2MWFS
STANDARD MAINTENANCE AND TROUBLESHOOTING
1. Shut o the water supply to the faucet.
2. Turn on the faucet briey to relieve any pressure inside the faucet.
3. Move the faucet handle to the “ OFF” position.
4.
Remove the plastic cover C from the handle A.
5. Remove the screw B using an allen key.
6. Pull the lever base A from the body .
7.
Unscrew the cap D.
8.
Unscrew the cartridge lock nut E.
9.
Lift ceramic disk cartridge F from the body and replace it with new cartridge. Ensure the two lugs on bottom of the cartridge sit properly in the allocated holes at the base of the body.
10. Re-assemble faucet in reverse order.
11. Test for leakage.
GENERAL MAINTENANCE
Clean aerator periodically for any buildup . Do not use harsh detergents, solvents, chemical agents, metallic sponges, etc. that could harm the surface and damage the nish. Clean only with a soft sponge and soapy water.
SPARE / REPLACEMENT LIST
Franke Kitchen Systems 800 Aviation Parkway Smyrna, TN 37167, USA Phone: 800-626-5771 Email: ks-customerservice.us@franke.com
them or about the guarantee, please contact our customer service department:
the original purchaser of its faucets effective January 1, 2003.
: Franke faucets are NOT
Franke Kitchen Systems,LLC extends the following warranty to
REPLACING THE CARTRIDGE
**
Must specify finish
"CH" chrome "SN" satin nickel
(i.e. F20001CH or F20001SN)
A+B+C Handle assembly
F20027** F20028 F20029
E. Lock nut F. Cartridge
G. Washer G1/2" H. Check Valve 1.75gpm
F20034
F20006
F20010
M. N. O. P. Q.
F20015
Escutcheon + sealing o-ring
Mounting hardware kit
Supply hoses Base plate + Base gasket Plastic flange
F20016**
D. Cap
F20017
F20026**
INSTALLATION MANUAL
FUJI
FFPD20400 Chrome FFPD20480 Satin Nickel
G+H+I+J+K. Pull Down spray assembly
J+K+L.
Aerator + Aerator key
F20036**
F20031
F20032**
TECHNICAL DATA
NOTE:
CONTENTS IN BOX
INSTALLATION INSTRUCTIONS
1. Remove all contents from the package and check for completeness.
2.
Turn o water supply.
Recommended Water Pressure Max. Water Pressure Recommended Hot Water Temp. Hole Size For Faucet
Certies this faucet complies with ASME A112.18.1 / CSA B125.1 & NSF 61, NSF 372 and AB1953
Flow Rate 1.6 GPM at 45 PSI
30-75 PSI
100 PSI 100° F
1 3/8”
1 Faucet assembly 2 Aerator key 3 Escutcheon 4 Sealing o-ring
5 Base plate 6 Base plate gasket
7 Plastic flange 8 Rubber washer 9 Fixing plate
10 Fixing nut 11 Supply hoses
3. Cut a mounting hole 1 3/8 diameter (35mm) in the desired position in counter top or sink (if one isn’t available).
4.
Place the escutcheon(3) and the sealing o-ring (4) over the base of the faucet. If your application has 3 holes to cover, install the base plate (5) and base plate gasket (6) over the holes and install the faucet. If your application is a single hole, the base plate (5) and base plate gasket (6) are optional.
ATTENTION: The base plate gasket should be sitting between the countertop and faucet base plate.
DO NOT use putty or other sealant at this location.
NOTES:
Solid surface i nstallation
: The countertop mounting sur face needs to be at and free of debris otherwise the faucet may not sit properly. For tile installations, avoid installing faucet near or on top of grout lines. This may cause a weak joint between the faucet and the counter and could cause leaks.
5.
Install the mounting hardware to the base of faucet body in
the following order - plastic flange (7), rubber washer (8),
fixing plate (9) as shown.
6. Tighten with the fixing nut (10) on the base of faucet body.
7.Connect the
flexible supply ho
ses (11) to the water supply in the
house.
8. Remove the aerator using the aerator key (2), turn on water, ush the faucet for any debris and check for leaks. Reinstall the aerator and ensure ever ything is functioning properly.
Contact us immediatly if you see inconsistencies.
Phone: (1- 800-626-5771) website: www.frankeksd.com
email: ks-customerservice.us@franke.com
Loading...