Franke FUD 5007 I XS Instructions For Use And Installation

Instructions for use and installation
Cooker Hood
Bedienungsanleitung und Einrichtung
FUD 5007 I XS
GB
DE
2
2
INDEX
RECOMMENDATIONS AND SUGGESTIONS.....................................................................................................................3
CHARACTERISTICS.............................................................................................................................................................4
INSTALLATION...................................................................................................................................................................... 7
USE......................................................................................................................................................................................17
MAINTENANCE...................................................................................................................................................................19
INHALTSVERZEICHNIS
EMPFEHLUNGEN UND HINWEISE...................................................................................................................................22
CHARAKTERISTIKEN.........................................................................................................................................................23
MONTAGE...........................................................................................................................................................................26
BEDIENUNG........................................................................................................................................................................36
WARTUNG...........................................................................................................................................................................38
EN
DE
EN
3
3
RECOMMENDATIONS AND SUGGESTIONS
The Instructions for Use apply to several versions of this appliance. Accord-
ingly, you may find descriptions of individual features that do not apply to your specific appliance.
INSTALLATION
• The manufacturer will not be held liable for any damages resulting from in­correct or improper installation.
• The minimum safety distance between the cooker top and the extractor hood is 650 mm (some models can be installed at a lower height, please re­fer to the paragraphs on working dimensions and installation).
• Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood.
• For Class I appliances, check that the domestic power supply guarantees adequate earthing.
Connect the extractor to the exhaust flue through a pipe of minimum diame-
ter 120 mm. The route of the flue must be as short as possible.
• Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.).
• If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air.
USE
• The extractor hood has been designed exclusi vely for dom estic use to elimi­nate kitchen smells.
• Never use the hood for purposes other than for which it has been designed.
• Never leave high naked flames under the hood when it is in operation.
• Adjust the flame in tensity to dire ct it on to the bottom of the pan only, ma king sure that it does not engulf the sides.
• Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames.
• Do not flambè under the range hood; risk of fire
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concern­ing use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appli­ance.
MAINTENANCE
• Switch off or unplug the appliance from the mains supply before carrying out any maintenance work.
• Clean and/or replace the Filters after the specified time period (Fire hazard).
• Clean the hood using a damp cloth and a neutral liquid detergent.
The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be hande d over to the applicable coll ection point for the recycling of electrical a nd el ectr on ic e quipm e nt. By ens ur ing t his pr oduct is disp os ed of c orr ect ly , you will help prevent po tential negative consequenc es for the environment and hum an health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
EN
4
4
CHARACTERISTICS
Components (Apollo-Jupiter model)
Ref. Q.ty Product Components 1 1 Hood Canopy complete with: Controls, Light, Filters, Motor. 2 1 Hood support Plate (with lamp holder) 3 1 Power supply cable lock 4 1 Cable raceway 5 1 Lampshade 6 6 Lamps 14 1 Pawl Ref. Q.ty Installation Components 11 4 Wall plugs ø 10 12h 4 Screws M5 x 70 12c 1 Screws 2.9 x 9.5 12d 4 Chrome plated glass fixing Pin/Screw 12g 1 Screw for pawl Q.ty Documentation
1 Instruction Manual
EN
5
5
APOLLO-JUPITER (20 Kg)
2
12h
11
12c
4
3
5
12d
12g
14
1
12d
12d
12d
6
EN
6
6
Dimensions
APOLLO
JUPITER
EN
7
7
INSTALLATION
This hood is design ed to be mou nte d on the ceil ing/on a shelf, above a free-standing Hob (min. 650 mm), in:
Ducting version: Evacuation to the outside.
Recirculation version: Internal recirculation.
Warning: The F-Light hood is a system comprising hood + lamp, so that two separate electric al
wiring systems must be provided, one for the hood and one for the lamp.
Sequence of operations - Installation
• Preparing for installation
• Drilling the Ceiling/Shelf and Fixing the support plate
• Connections
• Fitting the hood body
• Functional Check
• Disposal of Packaging
Fitting the Limiter pawl
• Unfasten the 3 screw that join the parts of the Plate (of different shapes and/or sizes) using the wrench provided.
• Take the Pawl and fix it to the plate on the bracket in the position indicated in the figure, using the screw provided.
• Take the bulb holders and slot them onto the brackets provided, which can be seen by their fork-shaped ends.
Warning: the clamps used to fix the wires
must not be cut.
• Tighten the Screw fixing the bulb holders to the bracket, in such a way as to hold the latter between the 2 washers.
EN
8
8
Ceiling/Shelf drilling and Plate Fixing
CEILING/SHELF DRILLING
• Use a plumb-line and mark the centre of the cooking hob on the Support Ceiling/Shelf.
• Rest the plate against the ceiling/shelf, taking care to keep the limit pawl that has just been fitted in a position facing the installer and the cooking hob (the limit pawl must not be con­fused with the other 4 used to fix the steel cables that move the Hood).
• Mark on the ceiling the centres of the holes in the plate.
• Drill the following points:
• Ceilings in solid concrete: As per concrete plugs used.
• Ceilings in hollow bricks with 20 mm resistance thickness: Drill a hole ø 10 mm (insert
Plugs 11 supplied immediately).
• Ceilings with Wood Beams: As per Wood Screws used (not supplied).
• Wooden shelf, with a resistant thickness of 15 mm: drill a hole ø 7 mm.
• Feeding the electric supply cable: drill a hole ø 10 mm.
Warning: there will be two lines to be connected: a direct electric line for the hood power
supply and another line with a switch for the lamp.
• Insert two screws, crossing them and leaving 4-5 mm from the ceiling:
• for solid concrete, concrete plugs, not provided.
• for hollow bricks with approx. 20 mm resistance thickness, screws 12h, provided.
• for wooden beams, wood screws, not provided.
• for wooden shelves, screws with washers and nuts, not provided.
EN
9
9
FIXING THE PLATE
• Lift up the fixing plate, taking care to ensure that the limit pawl is positioned frontally.
• Fit the slots onto the two screws previously inserted in the ceiling, and turn until they are at the centre of the adjustment slot.
• Tighten the two screws completely and screw in the other two provided; before locking the screws completely it is possible to make adjustments by turning the piece, making sure that the screws do not come out of the adjustment slot.
• The unit must be securely fastened both due to the weight of the Hood and the stress caused by occa­sional sideways pressure on the Appliance when in position. Once the unit has been fixed, make sure that the plate is stable.
• In all cases where the Ceiling is not sufficiently strong at the point of suspension, the Installation technician must strengthen it with suitable plates and counterplates, anchored to structurally sound elements.
2
1
1
2
EN
1
10
CONNECTING HOOD-PLATE CABLES
N.B. Before continuing with installation it is necessary to move the hood to a height
of at least 650 mm from the cooker hob, using a support or the assistance of an­other person.
This is essen tial, as the hood cables must necessarily be connected to the plate
fitted to the ceiling without the weight of the hood bearing on the structure.
• The cable fixing system is made up of 3 parts:
• Threaded Pawls (a) already mounted on the ceiling plate.
• Cable clamp screws (b) provided.
• Safety knobs (c) provided.
• Pass the cables connected to the hood ca­nopy into the respective holes in the plate cover, after dismantling
• Insert the cable
raceway 4 in the opening on the plate cover and pass the hood power supply cable through it.
4
a
b
c
EN
1
11
• Attention to the direction of the plate fixed to the ceiling (the limit pawl on the plate fastened to the ceiling has a corresponding hole on the plate cover and on the hood canopy).
• Insert the cables into the safety knobs (c)
with the thread at the top.
• Insert the cables into the cable clamp
screws (b)
B
C
EN
1
12
• Pass the cables through the slots in the threaded pawls (a) and screw the cable locking screws (b) to the pawls them­selves.
• When the operation has been completed the result must be as shown in the figure for all 4 ca­bles.
• At this point we have all 4 cables con­nected to the plate
Bring the cables under tension by push­ing them upwards so that they slide in­side the cable clamp screw and slide out of the slot in the threaded pawl.
This is possible because the cable clamp screw has a system that, if mounted properly, allows the cables to slide in­side it in one direction only, and pre­vents it from sliding in the other direc­tion.
Attention, the cables all have the same length to facilitate the operation of the final level. The front left cable must not be slacker than the others.
EN
1
13
• At this point it is possible to connect up the hood, and the lamp if there is one, to the power supply using the respective power cables.
Connections
AIR OUTLET - DUCTING VERSION
To install the hood in the ducting version, please refer to the instructions provided in the duct-
ing kit specific to the hood.
AIR OUTLET – RECIRCULATION VERSION
• Open the lighting unit by pulling on the notch provided.
• Remove the grease filter.
• Make sure that the Activated charcoal odour filter has been fitted.
• Close the plate cover using the 3 screws removed previously and the wrench provided
• At this point the Hood is sus­pended.
EN
1
14
LEVELLING THE HOOD
• The hood mobile unit must be levelled to allow the movement to operate properly.
• The hood is levelled by adjusting the safety pawls.
• Rest a spirit level on the hood.
• When the safety knobs are pressed upwards, movement of the hood is “unlocked”. By in­serting or extracting the cable from the cable clamp screw it is possible to make adjust­ments that allow the mobile hood body to be levelled.
• Once the hood has been set level, the safety knobs must be tightened again.
Warning:
• Please check that all 4 cables are stretched.
• Please check that all 4 cables were not damaged during installation.
• It must be remembered that the minimum distance between the hood and the cooking hob must be 650mm.
• The mobile unit (hood canopy) must have a maximum stroke of 900 mm in case of recirculation version and in the case of the ducting kit of 750mm.