Technical Data

The Fluke 87V-Ex is the ATEX-certified intrinsically safe version of the most popular meter in the world, the Fluke 87V. Intrinsically safe (I.S.) are protective methods employed in potentially explosive atmospheres. ATEX is the most stringent I.S. standard in Europe for products used in hazardous locations. Certified I.S. tools are designed to prevent the release of sufficient energy to cause ignition of flammable material.

I.S. standards apply to all equipment that can create one or more of a range of defined potential explosion sources such as electrical sparks, static electricity and mechanical friction. I.S. tools are designed for industries such as petro-chemical, grain processing, oil platforms and refineries, pharmaceutical and pipelines as well as other hazardous environments. For more information on intrinsic safety, visit www.fluke.com/ex.

Features:

Unique function for accurate voltage and frequency measurements on variable speed motor drives (VSD’s)

Atex 137 safety rating for use in zone 1 and zone 2

CAT IV 600 V safety approval for non-Ex industrial environments

Large display with bright, two-level backlight makes the 87V-Ex very easy to read

Built-in thermometer (probe included)

True-rms ac voltage and current for accurate measurements on non-linear signals

4-1/2 digit mode for precise measurements (20,000 counts)

Measure up to 1000 V and 10 A (ac/dc)

Frequency to 200 kHz and % duty cycle

Resistance, continuity and diode test

10,000 µF capacitance range for components and motor caps

Min/Max-Average and Peak capture to record transients and variations automatically

Relative mode to remove test lead interference on resistance measurements

Auto and manual ranging for maximum flexibility

Analog bargraph for fast changing or unstable signals

Input Alert provides audible warning against wrong use of input jacks

Safety ratings

ATEX safety rating: II 2 G EEx ia IIC T4

Electrical safety rating: EN61010-1 CAT IV 600 V and CAT III, 1000 V