Fluke 1743, 1735 Data Sheet

3000A/6000A Flex 4
for 174x and 173x PQ Analyzers
These current probe sets have been designed for applications with Fluke 1735 and Fluke 1740 series products for accurate non-intrusive measurement of AC currents. Using latest technologies (integrated memory for calibration data) provides current ranges from 0.8 A up to 6000 A in a frequency range of 40 Hz to 5 kHz. The flexis are approved for the required installation category.
Technical Data
Electrical specifications
Input ranges || L1, L2, L3, N 30/300/3000/6000 A ac Measuring range 0.8 A to 6000 A ac Intrinsic error <2 % of | Position influence max. ± 2 % of m.v. for distance conductor to measuring head >30 mm Stray field influence <± 2 A for | Temperature coefficient <0.05 % / K Current transformer ratio : 999 kA / | Ratio selection by job programming for 174x series
by setup menu for 1735
Connection 3-phase, 3-phase + N
2-phase L1 and L3 (2W-meter-method) 7 pole connector
|
= 500 A ac and distance to measuring head >200 mm
ext
|
General specifications
Cable length 4 m Length of measuring head 122 cm Operating temperature range -10 °C to +70 °C Storage temperature range -20 °C to +90 °C Operating humidity 10 % to 80 % (non-condensing) Weight 1.5 kg Environment temperature range +18 °C to +26 °C Humidity 20 % to 75 % r.h. Current Nominal value |n, sinusoidal waveform, 48 Hz to 65 Hz, distortion factor:
< 1 %, no dc component, stray field <40 A/m, conductor centred within LEM~flex
Safety standards IEC/EN61010-1:2001
IEC/EN61010-2-032:2002 IEC/EN61010-031:2002
EMC standards
IEC/EN 61326-1:2006
Safety 1000 V CAT III, 600 V CAT IV, pollution degree 2
The application of the LEM~flex on uninsulated conductors is limited to 1000 V ac r.m.s. or dc to ground and frequencies below 1 kHz.
Symbols
Do not apply around or remove from HAZARDOUS LIVE conductors, without using protective gloves.
Product is protected by double insulation.
Risk of Danger. Important information. See Instruction Sheet.
Canadian Standards Association has certified that the product meets applicable U.S. and Canadian Standards.
Conforms to relevant European Union directives.
Ordering information
3000/6000A FLEX 4: 3024472
3000A/6000A 36 inch Flexi Probe, 4 Phase
Fluke. Keeping your world up and running.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2009 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 11/2009 3564612A D-EN-N
Modification of this document is not permitted without written permission from Fluke Corporation.
®
2 Fluke Corporation 3000A/6000A Flex 4 for 174x and 173x PQ Analyzers