www.fairchildsemi.com 2
DM74LS367A
Absolute Maximum Ratings(Note 1)
Note 1: The “Absolute Maximum Ratin gs” are those v alues beyon d which
the safety of the dev ice cannot be guaranteed. T he device sh ould not be
operated at these limits. The parametric values defined in the Electrical
Characteristics tables are not guaranteed at the absolute maximum ratings.
The “Recommend ed O peratin g Cond itions” t able w ill defin e the co ndition s
for actual device operation.
Recommended Operating Conditions
Electrical Characteristics
over recommended operating free air temperature range (unless otherwise noted)
Note 2: All typicals are at VCC = 5V, TA = 25°C.
Note 3: Not more than one output should be shorted at a time, and the duration should not exceed one second.
Note 4: I
CC
is measured with the DATA inputs grounded and the OUTPUT CONTROLS at 4.5V.
Note 5: Both G
inputs are at 2V.
Note 6: Both G
inputs at 0.4V.
Switching Characteristics
at VCC = 5V and TA = 25°C
Note 7: CL = 5 pF.
Supply Voltage 7V
Input Voltage 7V
Operating Free Air Temperature Range 0°C to +70°C
Storage Temperature Range −65°C to +150°C
Symbol Parameter Min Nom Max Units
V
CC
Supply Voltage 4.75 5 5.25 V
V
IH
HIGH Level Input Voltage 2 V
V
IL
LOW Level Input Voltage 0.8 V
I
OH
HIGH Level Output Current −2.6 mA
I
OL
LOW Level Output Current 24 mA
T
A
Free Air Operating Temperature 0 70 °C
Symbol Parameter Conditions Min
Typ
Max Units
(Note 2)
V
I
Input Clamp Voltage VCC = Min, II = −18 mA −1.5 V
V
OH
HIGH Level VCC = Min, IOH = Max
2.4 3.4 V
Output Voltage VIL = Max, VIH = Min
V
OL
LOW Level VCC = Min, IOL = Max
0.35 0.5
Output Voltage VIL = Max, VIH = Min V
IOL = 12 mA, VCC = Min 0.25 0.4
I
I
Input Current @ Max Input Voltage VCC = Max, VI = 7V 0.1 mA
I
IH
HIGH Level Input Current VCC = Max, VI = 2.7V 20 µA
IIL LOW Level VCC = Max, VI = 0.5V (Note 5) A Input −20 µA
Input Current VCC = Max, VI = 0.4V (Note 6) A Input −0.4
mA
VCC = Max, VI = 0.4V G Input −0.4
I
OZH
Off-State Output Current with VCC = Max, VO = 2.4V
20 µA
HIGH Level Output Voltage Applied VIH = Min, VIL = Max
I
OZL
Off-State Output Current with VCC = Max, VO = 0.4V
−20 µA
LOW Level Output Voltage Applied VIH = Min, VIL = Max
I
OS
Short Circuit Output Current VCC = Max (Note 3) −20 −100 mA
I
CC
Supply Current VCC = Max (Note 4) 14 24 mA
RL = 667Ω
Symbol Parameter
CL = 50 pF CL = 150 pF
Units
Min Max Min Max
t
PLH
Propagation Delay Time LOW-to-HIGH Level Output 16 25 ns
t
PHL
Propagation Delay Time HIGH-to-LOW Level Output 16 25 ns
t
PZH
Output Enable Time to HIGH Level Output 30 40 ns
t
PZL
Output Enable Time to LOW Level Output 30 40 ns
t
PHZ
Output Disable Time from HIGH Level Output (Note 7) 20 ns
t
PLZ
Output Disable Time from LOW Level Output (Note 7) 20 ns