FAAC DTG User Manual

DTG
SAFETY EDGE INPUT TERMINALS
TEST
SWITCH
CODE SWITCH
KEYS
9 VOLT ALKALINE OR LITHIUM BATTERY
ANTENNA
TEST
INDICATOR
ATTACH DTG TO PLATE
3.88"
1.77"
WELD PLATE
TO GATE
Installation Instructions
(800) 421-1587 www.linearcorp.com
DESCRIPTION
The DTG is part of Linear’s Delta-3 product line and is compatible with all Delta-3 products. In a typical installation, the DTG is mounted on a motorized gate, door or barrier arm and wired to a standard exterior safety edge sensor which presents a closed circuit across the connecting wires when an object is hit during the closing of a gate. To insure full compatibility with all gate edge safety features, Linear recommends Miller gate edge sensors. If the edge sensor is pressed for a minimum of 1/8 second, the DTG transmits a message to the receiver to reverse the movement of the gate. The DTG circuit board has been coated to prevent moisture damage and is mounted inside a weather resistant fiberglass box. The mounting box attaches to the gate through sealed interior mounting screws.
TYPICAL
INSTALLATION
STEP 1
remove cover.
Remove Cover.
REMOVE
COVER
DTG
TRANSMITTER
SAFETY EDGE
SENSOR
Loosen the four screws on transmitter top and
LOOSEN
SCREWS
STEP 2
and details.
Locate Parts.
GATE
OPERATOR
Refer to diagram below for transmitter parts location
STEP 3
instructions included with the product.
Mount Safety Edge.
Mount safety edge according to manufacturer’s
INSTALL SAFETY EDGE
STEP 4
secure position. Use the template attached to mark the location for the transmitter. You may have to attach a metal or wood plate to mount transmitter. Use a 3/32" bit and drill holes. Attach DTG to gate using the four #6 self-tapping drill point screws.
Mount DTG.
Choose a location as high as possible on gate in a
STEP 5
Assemble Cable Grip.
Unscrew the cable grip about 3/4 of the way
and thread the safety edge cable through the cable entry on the transmitter.
TO SAFETY EDGE
LY
B
M
E
S
S
A
P
I
R
G
E
L
B
A
C
STEP 6
Attach Cable.
Attach safety edge cable to terminals as shown.
Tighten cable grip assembly using pliers to assure a water tight seal.
ATTACH EDGE SENSOR CABLE TO TERMINALSTO SAFETY EDGE
STEP 7
DTG Code Setting.
To set a code, select any valid combination of ON and OFF positions for the switch keys numbered 1 - 8. Refer to receiver installation instructions to code receiver switches.
USE A PAPER CLIP TO SET THE EIGHT KEYS
8
7
6
5
4
3
2
1
O
N
O
F
F
STEP 9
Wire Receiver.
Wire receiver obstacle output to obstacle input on
operator. Refer to operator and receiver wiring instructions.
GATE OPERATOR
DRG
Digital Gate Receiver
CHANNEL
ONE
GRAY
MANUAL ACCESS REQUEST
1
COMMON
2
RELAY
3
24 V RADIO POWER
OBSTACLE INPUT
YELLOW
CHANNEL
TWO
1
2
COMMON OBSTACLE
STEP 8
Test Safety Edge.
Test safety edge connection by pressing the
safety edge. The test indicator light should come on.
TEST INDICATOR SHOULD LIGHT WHEN SAFETY EDGE IS PRESSED
PRESS WITH HAND
STEP 10
Test System.
Activate the gate to close. As the gate is closing, press
the safety edge with your hand. Gate should stop and reverse.
CAUTION! DO not stand in the path of the closing gate.
PRESS SAFETY EDGE
WARNING! NO AUTOMATIC SUPERVISION OF A DAMAGED GATE EDGE SENSOR IS PROVIDED. USER IS CAUTIONED TO TEST THE TRANSMITTER REGULARLY.
CLOSE GATE
STEP 11
Replacing Batteries.
If LED indicator fails to light when test button
is pushed, replace with a 9 volt alkaline or lithium battery.
UNSNAP
BATTERY CLIP
WARNING! NO LOW BATTERY REPORTS ARE SENT WHEN THE BATTERY GETS WEAK. USER IS CAUTIONED TO TEST THE TRANSMITTER MONTHLY.
REMOVE BATTERY
FROM HOLDER
This product is warranted to the consumer against defects in material and workmanship for one year from the date of purchase. This warranty applies to first retail buyers of new dev ices. Warrantor will repair, or at its option, replace, any device it finds that requires service under this warranty, and will return t he repaired or repla ced device to the con sumer at the warrantor’s cost. For warranty service and shipping inst ructions contact warrantor at the addr ess shown below. Devices must be sent to warrantor for service at owner’s expense. The remedies provided by this warranty are exclusive. Implied warranties under state law are to the one year period of this written warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. In order to be protected by this warranty, save your proof of purchase and send copy with equipment should repair be required. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
Linear radio controls provide a reliable communications link and fill an important need in portable wireless signaling. However, there are some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio s ignals that occur on or near their operating frequencies, regardless of code settings.
Changes or modifications to the device may void FCC compliance.
Infrequently used radio links should be tested regularly to protect against undet ected int erf erence or fau lt.
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.
Copyright  1999 Linear Corporation 211906 B
LIMITED WARRANTY
IMPORTANT !!!