CVT-OPTW
Operations Manual
Wiegand Splitter
EXP-1000 Part 15 Class A
CVT-OPTW_MAN_111711
FCC Part 15 COMPLIANCE
Physical
2.313” x 1.625” x 0.625-
Temp
Storage(-55˚C to + 150˚C) Operating(-40˚C to +80˚C)
Humidity
95% (non-condensing) Input
+5VDC @100mA
Power
Output
Data I/O
Interface
Reader 0- 30VDC LED - 0 - 30VDC Analog 0 - 5 VDC
Electrical and Mechanical Specifications
This device complies with part 15 of the FCC Rules.
Cypress Computer Systems, Inc. Lapeer, MI 48446 www.cypresscomputer.com
© 2011 Cypress Computer Systems Inc.
The CVT-OPTW is designed to provide isolation between different Wiegand signal
Data 1 IN
Ground
Data 0 IN
Data 1 OUT
Data 0 OUT
Pullup +5V
Pullup +5V
+5 VDC
Ground
sources.
The CVT-OPTW allows multiple readers and panels to be connected together
The CVT-OPTW also allows systems with different voltage levels to be electrically connected together.
J1 Connector
Gnd - Input Ground
• Data 0 In - Wiegand Data Input 5- 24 VDC
• Data 1 In- Wiegand Data Input 5 - 24 VDC
J2 Connector
5 vdc - Input - regulated 5 vdc @ 30ma
• Pullup +5V - Connection to pullup resistor 1k @ 5VDC
• Data 0 OUT - Open collector Wiegand data output
• Pullup +5V - Connection to pullup resistor 1k @ 5VDC
• Data 1 OUT - Open collector wiegand data output
• Gnd - Output ground
Notes:
1. Input Ground and Output Ground are electrically isolated.
2. +5VDC (Regulated) is required to operate converter.
Data 1 IN
Ground
Data 0 IN
Previous versions of the CVT-OPTW had internal pullup resistors internal connected to the
Data 1 OUT
Data 0 OUT
+5 VDC
Ground
Data 1 OUT
Data 0 OUT
+5 VDC
Ground
Data 1 IN
Ground
Data 0 IN
output ports. These pullup resistors were wired to the +5VDC supply. This newer version provides the option of connecting the pullup resistors in order to allow connection as a true open collector output.
With the pullup resistors connected as indicated in the above diagram, the new OPTW is equivalent to the previous version.
If voltage levels other than 5 volts are required at the output, then do not connect the internal pullup resistors. The outputs are now open collector and will work with voltages from 5 to 24 VDC. Depending on the system, pullup resistors to the higher voltage may be required.