Carrying out control using control buttons............................. 25
Carrying out control using a web browser (Web control) ......26
Carrying out control using timer settings ...............................26
Procedures for new timer settings.............................................. 27
Setting the mail notification function28
If a problem notification e-mail message
has been sent30
Application lock function31
Troubleshooting32
Projectors cannot be monitored or controlled ....................... 32
An e-mail message is not sent when a problem
occurs with a projector........................................................ 32
Switching application lock between enabled
and disabled........................................................................ 31
Enabling the lock ....................................................................... 31
Disabling the lock ...................................................................... 31
Setting a password for cancelling application lock ................ 31
Tasks that can be done using EMP Monitor
EMP Monitor lets you carry out operations such as checking the statuses of
multiple EPSON projectors that are connected to a network at a computer
monitor, and controlling the projectors from the computer.
Following are brief descriptions of the monitoring and control functions that
can be carried out using EMP Monitor.
• Registering projectors for monitoring and control
- Projectors on the network can be searched for automatically, and you can
then select projectors to be registered from the projectors that are detected.
- You can enter the IP addresses for target projectors to register them.
• Registered projectors can also be assigned to groups so that they
can be monitored and controlled in groups
• Monitoring the statuses of registered projectors
- The power status (ON/OFF) for projectors and problem and warning
statuses can be checked visually by means of icons.
- You can select groups of projectors or a single projector that you are
interested in, and then check the cumulative lamp operating time or check
the details of information on input sources, problems and warnings for
these projectors.
• Controlling registered projectors
- Projectors can be selected in groups or as single projectors, and you can
then carry out operations for the selected projectors such as turning the
power on and off and switching their input sources.
- Web control functions can be used to change the settings in the projector's
configuration menu.
- If there are certain control actions which are carried out regularly at
particular times or on particular days, you can use "Timer Settings" to
register timer settings.
• E-mail notification function settings
You can set e-mail addresses for problem notifications to be sent to if a
problem occurs with a projector that has been registered.
Projector A
Projector B
TIP
To enable projectors to be monitored and controlled even when they
are in standby mode*, make the following settings at the projectors.
The settings that need to be made will vary depending on the projector
you are using.
s "Configuration menus" in the projector's User's Guide.
• Set "Network Monitoring" to "ON".
• Set "Standby Mode" to "Network ON".
* When the projector's (Power) indicator is lit orange
4
Group A
I want to turn on the
power for Group A
projectors.
Group B
EMP Monitor
System configuration example
Operating environment
5
Compatible computers
Macintosh computers cannot be used.
OS98SE/Me/NT4.0/2000 Professional/XP Home Edition/XP
Professional
• Internet Explorer Ver. 5.0 or later must be installed.
CPUPentium MMX 166 MHz or higher (Pentium II 233 MHz
or higher recommended)
Memory
capacity
Free hard disk
space
DisplaySVGA (800× 600) or higher resolution, 32 bit or higher
* Operations carried out at the computer may become slow depending on the
number of projectors being managed. If this happens, use a computer with
higher specifications.
* EMP Monitor cannot be used in environments which do not allow pings to
be transmitted.
64 MB or more (128 MB or more recommended)
50 MB or more
display colour
Installing EMP Monitor
If using Windows 2000, NT4.0 or XP, the computer must be started up in
Administrator mode.
Place the "EPSON Projector Software for Monitoring"
2
CD-ROM in the computer's CD-ROM drive.
The installer automatically starts up.
From here, continue with the installation by following
3
the on-screen messages.
Before starting operations
Check the following points before starting up EMP Monitor.
• EMP Monitor must be installed on the computer to be used for
monitoring and control.
• The computer and the projectors must be connected to the network.
• If using Windows 2000, NT4.0 or XP, the computer must be started up in
Administrator mode.
When using EMP-6000/821/81/61
• A commercially-available serial ⇔ TCP/IP conversion adapter and a
connection cable are required in order to use EMP Monitor.
s"Standby mode" in the projector's User's Guide
• Make the settings for the serial ⇔ TCP/IP conversion adapter before
connecting to the projector.
PROCEDURE
Turn the computer on, and quit all running
1
applications.
Registering and deleting projectors for monitoring
6
This operation is carried out when starting EMP Monitor for the first time after
it has been installed and when you would like to add projectors. Once a
projector has been registered, the status for the projector will be displayed
automatically each time EMP Monitor is started from that point onwards.
Projector] - [EMP Monitor V4.10] in that order to start
EMP Monitor.
The main window will be displayed.
2
"Grouping view"
The operations to register projectors using the automatic search will
vary depending on where the projectors are connected to in the
network.
• When registering a projector that is located in the same segment
that the computer the EMP Monitor is installed in is associated
with. s"Registering projectors using automatic search (Searching
for and registering projectors that are located in the same segment)"
p.7
• When registering projectors that are in multiple segments of the
network s"Setting the range of addresses to do an automatic
search and registration" p.9
Registering and deleting projectors for monitoring
7
Registering projectors using automatic search
(Searching for and registering projectors that are
located in the same segment)
PROCEDURE
f Procedures for automatic search
Right-click in "Grouping view" and select "New" -
1
"Projector (automatic search)".
The "Create new projector (automatic registration)" window
will be displayed.
• If "Detail list view" is displayed, select "New" - "Projector
(automatic search)" from the "Edit" menu.
Click [Search].
2
Automatic search will be carried out, and the names of the
projectors that have been detected will be displayed.
• If a projector does not appear in the list, use "Registration by
specifying an IP address (Manual registration)". sp.11
TIP
• You can also carry out this operation by selecting "Projector
(automatic search)" from "New" in the "Edit" menu.
⇔
• Projectors that are using a serial
cannot be detected.
TCP/IP conversion adapter
Registering and deleting projectors for monitoring
8
f Procedures for registration
Select the projector(s) to be registered, and then click
3
[Edit].
The following window will be displayed.
Make the necessary settings while referring to the following
table.
Projector
name
IP addressThis shows the IP address for the registered projector.
Use Serial ⇔
TCP/IP
conversion
adaptor.
Port NumberThis cannot be selected when registering projectors
Monitor
Password
DescriptionYou can enter some kind of memo about the projector.
MonitorSelect this when you want monitoring to start.
This shows the name that has been registered on the
projector.
This cannot be selected when registering projectors
using automatic search.
using automatic search.
If a Monitor Password has been set for the projector,
be sure to enter the Monitor Password that has been
set. If the correct password is not entered at this time,
it will not be possible to monitor and control the
projector even though it is registered.
The details you enter here will be displayed at the
projector properties.
Up to a maximum of 60 bytes can be entered.
Display nameEnter the name of the projector(s) to be displayed in
"Grouping view" or "Detail list view".
Up to a maximum of 32 bytes can be entered.
A space cannot be used as the first character.
Display iconSelect the icon(s) to be displayed in "Grouping view"
or "Detail list view".
Parent groupSelect when registering a projector in a group.
If no groups have been created, this cannot be
selected. s"Registering several projectors to a
monitoring group all at once" p.12
4
After entering the details, click [Register] to start the
registration. When the message is displayed, click
[OK].
To continue registering other projector(s), repeat Steps 3 and 4.
TIP
Projectors that have been registered using automatic search are
searched for again by projector name each time EMP Monitor is
started.
Registering and deleting projectors for monitoring
5
To end the registration operation, click the in the
top-right corner of the window or click [Cancel].
The icon(s) of the projector(s) you registered will be displayed
in "Grouping view" or "Detail list view".
Refer to "Monitoring window layout" for details on using the
"Grouping view" and "Detail list view".
sp.16
Setting the range of addresses to do an automatic
search and registration
TIP
Projectors that are using a serial ⇔ TCP/IP conversion adapter
cannot be detected.
PROCEDURE
Select the "Specify an address range and search"
2
check box and then enter the starting address and
ending address in the range.
Click [Search].
3
Automatic searching will be carried out, and the names of the
projectors that have been detected will be displayed.
9
f Procedures for automatic search
Right-click in "Grouping view" and select "New" -
1
"Projector (automatic search)".
The "Create new projector (automatic registration)" window
will be displayed.
• If "Detail list view" is displayed, select "New" - "Projector
(automatic search)" from the "Edit" menu.
Registering and deleting projectors for monitoring
10
f Procedures for registration
Select the projector(s) to be registered, and then click
4
[Edit].
The following window will be displayed.
Make the necessary settings while referring to the following
table.
Projector
name
IP addressThis shows the IP address for the registered projector.
Use Serial⇔
TCP/IP
conversion
adaptor.
Port NumberThis cannot be selected when registering projectors
Monitor
Password
DescriptionYou can enter some kind of memo about the projector.
MonitorSelect this when you want monitoring to start.
This shows the name that has been registered on the
projector.
This cannot be selected when registering projectors
using automatic search.
using automatic search.
If a Monitor Password has been set for the projector,
be sure to enter the Monitor Password that has been
set. If the correct password is not entered at this time,
it will not be possible to monitor and control the
projector even though it is registered.
The details you enter here will be displayed at the
projector properties.
Up to a maximum of 60 bytes can be entered.
Display nameEnter the name of the projector(s) to be displayed in
"Grouping view" or "Detail list view".
Up to a maximum of 32 bytes can be entered.
A space cannot be used as the first character.
Display iconSelect the icon(s) to be displayed in "Grouping view"
or "Detail list view".
Parent groupSelect when registering a projector in a group.
If no groups have been created, this cannot be
selected. s"Registering several projectors to a
monitoring group all at once" p.12
After entering the details, click [Register] to start the
5
registration. When the message is displayed, click
[OK].
To continue registering other projector(s), repeat Steps 4 and 5.
To end the registration operation, click in the top-
6
right corner of the window or click [Cancel].
The icon(s) of the projector(s) you registered will be displayed
in "Grouping view" or "Detail list view".
Refer to "Moitoring window layout" for details on using the
"Grouping view" and "Detail list view".
sp.16