Epson EXPRESSION 836 MonacoScan User Guide

MonacoSCAN User’s Guide
For Microsoft® Windows® 95, Windows 98, Windows NT® 4.0,
and Apple® Power Ma ci nt os h
®

Copyright Notice

All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SEIKO EPSON CORPORATION. The information contained herein is designed only for use with this EPSO N scanner. EPSON is not responsible for any use of this information as applied to other scanners.
Neither SEIKO EPSON CORPORATION nor its aff iliates shall be liable to the purchaser of this product or third parties for damages, losses, costs, or expenses incurred by purchaser or third parties as a result of: accident, misuse, or abuse of this product or unauthorized modifications, repairs, or alterations to this product, or (excluding the U.S.) failure to strictly comply with SEIKO EPSON CORPORATION’s operating and maintenance instructions.
SEIKO EPSON CORPO RATIO N and its affiliates shall not be liable for any damages or problems arising from the use of any options or any consumable products other than those designated as Original EPSON Produc ts or EPSON Approved Products by SEIKO EPSON CORPORATION.
EPSON is a registered trademark of SEIKO EPSON CORPORATION. EPSON Expression is a registered trademark of Epson America, Inc.
MonacoSCAN is a trademark of Monaco Systems. General Notice: Other product names used herein are for identification purposes only and may be
trademarks of their respective companies. Copyright © 1999 by Epson America, Inc., Torrance, California, USA MNCOSCN0699-R1
6/99
Page 2

Contents

Introduction 4
System Requirements 5 Where to Get Help 5
Calibrating with MonacoSCAN 6
Scanning the IT8 Target 7 Selectin g Your Targe t and Referenc e F iles 10 Cropping the Target Image 12 Calibrati ng and Evalu at ing the Res ult s 20 Saving Your Calibration Profile 22
Loading th e M onacoSCAN Separ at ion Table 23
Photosh op 3.0 or 4.0 23 Photoshop 5.0 24
Page 3

Introduction

Monaco SC AN™ color m anagem ent software lets you create a unique input profile for your scanner by calibrating the scanner colors. When you use the pro f ile, th e c olors in your s c anned ima ge m ore closely m at c h t he colors in the original.
To create an input pro fi le, yo u f irs t scan the indu s tr y -s ta ndard IT8 ta rget image that came with your scanner and save it as a TIFF file. Then you use MonacoSCAN to compare the TIFF file with a color reference file. Monaco SC AN reports a m easure of th e c olor differences and creates an input prof ile t hat adjusts f or t hose differ enc es as you scan.
MonacoSCAN also comes with an output device profile you can load into Adobe you’ll outp ut on a MatchP rint.™
See your scanner on your system. Then se e t hese sect i ons fo r i nstru cti o ns on cr eati ng yo ur input prof ile and using th e output prof ile f or color separations:
Calibrating with MonacoSCANLoading th e M onacoSCAN Separ at ion Table
®
Photoshop® as a separ at ion table for s of t proofing images that
Setup Guide
for instructions on installing MonacoSCAN
Page 4

System Requirements

Before ins t alling Mona c oSCAN, mak e sure your sy stem meets t he following requireme nt s .
Windows System Requirements
PC with a Pentium® or higher pro c es s or ◗ Microsoft Windows 95, Windows 98, or Windows NT 4.020MB RAM av ailable for MonacoSCANVGA or hig her standard monitor w it h a 24-bit displa y adapter
Macintosh System Requirements
Apple Power Macintosh computer running system 7.5 or later
operating system
20MB RAM av ailable for MonacoSCANColor mon it or w it h a 24-bit display adap te r

Where to Get Help

If you need help usi ng MonacoSCAN, co nt act Monaco S yste ms te chni cal support as follows:
World Wid e W eb addres s : m o n acosys.com Electronic mail address: support@monacosys.com Telephone numbe r: (978) 749- 9944
Page 5

Calibrating with MonacoSCAN

When you ca librate your s c anner colo rs w ith M onacoSCAN, you’ll be performi ng these proc edures:
Scanning the IT8 TargetSelectin g Your Targe t and Referenc e F ilesCropping the Target ImageCalibrati ng and Evalu at ing the Res ult sSaving Your Calibration Profile
When you ’re ready to load your calibration pr of ile into your ap plic ation, follow the ins t ructions in yo ur application docume nt at ion.
Page 6
Handle the IT8 target very carefully. If it becomes bent, torn, or scratched, it won't be able to give you a true calibrated profile.
You cannot use the enclosed IT8 target to create a prof ile for transpa rencies.

Scanning the IT8 Target

Before scanning the IT8 target for reflective images that comes with MonacoSCAN, make sure you have successfully installed your scanning applicat ion program and either the EPSON LaserSof t® SilverFa st® plug-in for Photoshop.
®
TWAIN Pro driv er or the
See the docum ent ation that came in the target package for information on caring for your target and purchasing replacem ents or transparency targets, if necess ary .
target date
You may h av e already verified that yo ur s c anner and software are working b y fol low ing the inst ruc t ions in your s c anner
Setup Guide
. If you
haven’t scanned yet, be sure to try it before scanning the IT8 target.
target name
Page 7
1 Make sure y our scanner is turned on and its docum ent table glass is
clean and lint-free.
2 Place the IT8 ta rge t facedown on the docu ment table with i ts upper left
corner aligned with th e upper left c orner of the sca nning area.
3 Start your application and open your scanning software (either EPSON
TWAIN P ro or LaserSo f t S ilv erF ast) as desc ribed in its online
Guide
.
User’s
If you’re c reating the profile fo r s ca nning with EPSON TWAIN Pro, use TWAIN Pro to scan the target. If you’re creating the profile fo r LaserSoft SilverFast, use SilverFast to scan it.
4 Click the Preview (EPSON T W AIN Pro) or Prescan (LaserSoft
SilverFa s t) but t on t o prescan th e t arget image.
5 Now turn off the automatic features in the scanning software.
In SilverFast, hold do w n t he Alt (Windows ) or option (Macintosh) key and click th e Auto Adjust button t o t urn off the automatic adjustment feature.
In EPSON TWAIN Pro, click the Reset button on th e Preview window to turn off all the automatic adjustment features.
6 In SilverFast, adjust th e f ram e on the image until it cont ains only the
IT8 target . In EPSON T W AI N Pro, draw a m arquee around the ed ges of the IT8
target image.
7 Click the Scan (or Scan R GB) button to scan the target.
Page 8