92
Special Features
60 Watts
LPS60 Series
Electrical Specs
VDE 0805/EN60950 (IEC950) 11774-3336-1255
(LC #86665)
UL UL1950 E132002 CSA CSA 22.2-234 Level 3 LR53982C NEMKO EN 60950/EMKO-TUE P95100123
(74-sec) 203
CB Certificate and report 1521, 1522, 1523, 1524 CE Mark (LVD)
• Universal input
• 3” x 5” footprint
• Remote sense
• Built-in EMI filter
• Low output ripple
• Adjustable output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX60 enclosure kit available
Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C
Electromagnetic susceptibility: designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing 5% to 95%
Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions.
Input
Input range 85-264 VAC
120-300 VDC Frequency 47-440 Hz Inrush current <18 A peak @ 115 VAC;
<36 A peak @ 230 VAC,
cold start @ 25°C Input current 1.5 A max. (RMS) @ 115 VAC Efficiency 70% typical at full load EMI filter FCC Class B conducted
CISPR 22 Class B conducted
EN55022 class B conducted
VDE 0878 PT3 class B conducted Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power 60 W for convection;
80 W with 30 CFM forced air Adjustment range -5, +10% minimum Hold-up time 20 ms @ 60 W load, 115 VAC nominal
line Overload protection Short circuit protection on all outputs.
Case overload protected @ 110-
145% above peak rating Overvoltage protection 5 V output: 5.7-6.7 VDC. Other
outputs 10% to 25% above nominal
output Remote sense Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
Environmental
Safety
Total Power: 60-80 Watts Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Single
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44(1384) 843-355
AMERICAS
5810 Van Allen Way Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
93
www.astecpower.com
Ordering Information
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Model Output Minimum Maximum Load with Maximum Load with Peak Regulation2 Ripple Number Voltage Load Convection Cooling 30 CFM Forced Air Load1 P/P (PARD)3
LPS61 3.3 V 2 A 12 A 16 A 18 A ±2% 33 mV LPS62 5 V 0 A 12 A 16 A 18 A ±2% 50 mV LPS63 12 V 0 A 5 A 6.7 A 7.5 A ±2% 120 mV LPS64 15 V 0 A 4 A 5.3 A 6 A ±2% 150 mV LPS65 24 V 0 A 2.5 A 3.3 A 3.8 A ±2% 240 mV LPS68 48 V 0 A 1.3 A 1.7 A 1.9 A ±2% 480 mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
Connector LPS61 LPS62 LPS63 LPS64 LPS65 LPS68
SK1-1 Neutral Neutral Neutral Neutral Neutral Neutral SK1-3 Line Line Line Line Line Line
SK2-1 3.3 V +5 V +12 V +15 V +24 V 48 V SK2-2 3.3 V +5 V +12 V +15 V +24 V 48 V SK2-3 3.3 V +5 V +12 V +15 V +24 V 48 V SK2-4 Common Common Common Common Common Common SK2-5 Common Common Common Common Common Common SK2-6 Common Common Common Common Common Common SK201-1 +Sense +Sense +Sense +Sense +Sense +Sense SK201-2 -Sense -Sense -Sense -Sense -Sense -Sense
Mating Connectors
AC Input: Molex 09-50-8031 (USA)
09-91-0300 (UK) PINS: 08-58-0111
DC Outputs: Molex 09-50-8061 (USA)
09-91-0600 (UK) PINS: 08-58-0111
Remote Sense: Molex 22-01-2025
PINS: 08-50-0114
Astec Connector Kit #70-841-006, includes all of the above
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±.02”.
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings at 115 VAC input, 25°C unless otherwise stated.
6. Warranty: 1 year
7. Weight: 0.75 lb. / 0.34 kg
Pin Assignments
3.00"
(
76.2)
2.55"
(64.8)
0.22" (5.6)
0.22" (5.6)
4.56"
(115.8)
5.00" (127)
1.65"
(41.9)
0.12" (3)
SK 1
SK 2
1 2 3 4 5 6
0.15" (4)
DIA (4 places)
GND
1 3
N L
M1
M2
Remote Sense
Connector
_
+
SK201
Voltage Adj. Pot
Power Derating Curve
Output
Power
(Watts)
0°C
20W
40W
60W
80W
10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Tem
p
erature – °C
0W
Natural
Convection
Cooling
40W
30W
30 CFM Forced Air Cooling