Special Features
Electrical Specs
350 Watts
LPS350 Series
Input range 85-264 VAC; 120-300 VDC Frequency 47-440 Hz Inrush current 38 A max., cold start @ 25°C Efficiency 75% typical at full load EMI filter FCC Class B conducted and radiated
CISPR 22 Class B conducted and radiated EN55022 Class B conducted and radiated VDE 0878 PT3 Class B conducted and
radiated. Power factor 0.99 typical Safety ground leakage current <0.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power With cover: 350 W with 30 CFM forced
air,
(-C) (-CF) (-CEF) Adjustment range 2:1 wide ratio Supervisory outputs 5 V @ 500 mA regulated, 12 V @ 150 mA x2 Hold-up time 20 ms @ 350 W load, 115 VAC nominal
line
at factory voltage setting Overload protection Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating Overvoltage protection 5 V output: 5.7-6.7 VDC. Other models
10% to 25% above nominal output
Logic Control
Power failure TTL logic signal goes high 50-150 msec
after 5 V output. It goes low at least 4
msec before loss of regulation Remote on/off Requires an external contact (N.O or
N.C) to inhibit outputs DC-OK TTL logic goes high 50-150 msec after
the output. It goes low when there is
loss of regulation. Remote sense Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection protected.
• Active power factor correction
• IEC EN6100-3-2 compliance
• Remote sense
• Power fail and remote inhibit
• Single wire current sharing
• Built-in EMI filter
• Low output ripple
• Supervisory output 5 V and 12 V
• Overvoltage protection
•Overload protection
• Thermal overload protection
• DC power good
•Cover -C
• 130 KHz switching frequency
• Optional with fan cover -CF
• Optional end-mounted fan - CEF
Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C
Electromagnetic susceptibility: Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity: Operating; non-condensing 5% to 95%
Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances
0.7 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions
VDE 0805/EN60950 (IEC950) 21310-3336-0001 ULUL1950 E186249 CSA CSA 22.2-234 Level 5 LR109492C NEMKO EN 60950/EMKO-TUE P98102115
(74-sec) 203
BABT EN60950/BS7002 608857, 608858, 609097 CB Certificate and report 5734, 6280, 6281 CE Mark (LVD)
Environmental
Total Power: 350 Watts Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Single