rev 12.01.01
America’s (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211 Asia (HK): 852-2437-9662
112
Special Features
Electrical Specs
150 Watts
LPS150 Series
Input
Input range 85-132 VAC
or 170-264 VAC automatically
selected.
220-300 VDC
Frequency 47-63 Hz
Inrush current 38 A max, cold start @ 25°C
Efficiency 75% typical at full load
EMI filter FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Safety ground
leakage current <0.5 mA @ 50/60 Hz, 264 VAC input
Output
Maximum power 110 W convection (75 W with cover)
150 W with 30 CFM forced air
(130 W with cover)
Adjustment range ±5% minimum
Hold-up time 20 ms @ 110 W load, 115/230 VAC
nominal line
Overload protection Short circuit protection. Case overload
protected @ 110% to 145% above
peak rating
Overvoltage protection 5 V output: 5.7 to 6.7 VDC. Other
outputs 10% to 25% above nominal
output
Logic Control
Power Failure TTL Logic signal goes high 50-150
msec after 5 V output. It goes low at
least 3 ms before loss of regulation.
Remote inhibit Requires an external TTL high signal to
inhibit outputs.
Remote sense Compensates for 0.5 V lead drop
minimum, will operate without
remote sense connected. Reverse
connection protected.
• Auto ranging input
• Remote sense
• Remote inhibit
•Power fail
• Single wire current sharing
• Built-in EMI filter
• Low output ripple
• Adjustable output
• 135 khz switching frequency
• Overvoltage protection
• Overload protection
• Optional cover (-C suffix).
Operating temperature: 0° to 50°C ambient;
derate each output at 2.5% per degree from 50°
to 70°C
Electromagnetic susceptibility: Designed to
meet IEC 801, -2, -3, -4, -5,-6, Level 3
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.75 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditions
VDE 0805/EN60950 (IEC950) 11774-3336-1260 (LC#88585)
UL UL1950 EI32002
CSA CSA 22.2-234 Level 3 LR53982
NEMKO EN 60950/EMKO-TUE P95102999
(74-sec) 203
BABT EN60950/BS7002 607019
CB Certificate and report 2062
CE Mark (LVD)
Environmental
Safety
Total Power: 110-150 Watts
Input Voltage: 85-132 / 170-264 VAC
220-300 VDC
# of Outputs: Single