Emerson LK65 Owner's Manual

WARNING: Over lamping the light kit result with a blown fuse. Before replacing the fuse, shut off the electrical supply at the main fuse box or circuit breaker panel. The fuse is loca­ ted on the top surface of the light kit housing. Replacement fuse shall be rated 125VAC, and
1.25A. Do do exceed the 1.25A maximum curr­ ent rating. Replace the old lamps with new 60W maximum candelabra lamps. Restore electrical power to the light kit at the main fuse box or circuit breaker panel.
the
LK65
2.47
BP7406
74060000
1/09
09/09
74060000
BP7406
LK65
Safety Instructions
WARNING: To avoid fire, shock, and serious personal injury, follow all
instructions carefully.
1. Read your Owner's Manual carefully before installing the light fixture. Retain Owner's Manual for future reference.
2. Be careful of the fan and blades when cleaning, painting, or working near the fan. Before installing or servicing the light fixture or ceiling fan, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3.Do not exceed the wattage indicated on fixture (two 60-watt candelabra base bulbs maximum).
ADDITIONAL SAFETY INSTRUCTIONS FOR INSTALLATION
1. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring.
2.Make certain no bare wires are exposed outside the wire connectors.
3.All wiring must conform to National and Local Electrical Codes.
4.Follow the recommended instructions for the proper method of wiring your new light fixture. If you feel you do not have enough electrical wiring knowledge or experience, have your fixture installed by a licensed electrician. Any electrical work not described in this manual should be performed by a licensed electrician.
WARNING: To reduce the risk of possible fire and electrical shock, install only on Emerson CF and F Series Ceiling Fans. This light fixture is not
to be used with CF652, CF653, CF670, CF680, CF742, and CF2000 Series Ceiling Fans installed in damp or wet locations.
2
1.Remove the cover from the switch housing below ceiling fan. Replace the screws loosely in the switch housing. Do not tighten. (Figure 4.)
2.Carefully pull down white and blue wires from the switch housing and remove wire connectors.
Do not install or use the light fixture if any part is missing or damaged. Contact your dealer for replacement.
WARNING
To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring.
WARNING
Installation on Emerson Fans Having a Modular
Switch Cup with Center Screw
Do not install or use the light fixture if any part is missing or damaged. Contact your dealer for replacement.
WARNING
To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring.
WARNING
1.Remove the switch cup from the cover plate by removing the three screws around the side of the switch cup (Figure 1).
2.Disconnect the motor connector from the switch cup connector.
Figure 1
3.Remove the center screw from the switch cup (Figure 1).
4.Carefully locate the white and blue wires (labeled either "L" or "LIGHT") in the switch cup and remove the wire connectors from the wires.
5.Install the black and white wires from the light fitter and thread the switch cup onto the light fitter. Hold wires taut while installing switch cup to prevent the wires from twisting. Install and tighten the lockwasher and nut onto the fitter (Figure 2).
6.Position the light fitter so that the chain bushing in the light fitter aligns with the pull chain in the switch cup (Figure 2).
7.Connect the white wire from the switch cup to the white wire of the light fitter (Figure 2). Connect the blue wire from the switch cup to the black wire of the light fitter. Use listed wire connectors (previously removed in Step 4) to make connections (Figures 2 and 3).
Figure 2
Figure 3
WARNING: To avoid possible fire or electrical shock, make certain no bare wire strands are exposed outside wire connectors.
8.Carefully tuck all wires and splices into
the switch cup (Figure 2).
9. Connect the motor connector to the switch cup connector.
10. Position the cup/light fitter on the cover plate and install the three screws that were previously removed (Figure 1) and tighten securely.
11. Remove the wooden ball and pass the fan switch chain through the bushing in the fitter.
12. Proceed to “Installation of Glass Globe” section.
To avoid possible fire or electric shock, be careful not to pinch wires between switch cup and the cover plate.
WARNING
To avoid possible fire hazard, do not exceed wattage indicated on the fixture.
WARNING
Installation on Emerson
Fans Having Two-Piece
Die-Cast Switch
Housings
3
MOTOR CONNECTOR
SCREWS
SWITCH CUP
CENTER SCREW
COVER PLATE
SWITCH CUP CONNECTOR
MOTOR CONNECTOR
BLACK WIRE
BLUE WIRE
HEX NUT
SCREWS
LOCKWASHER
SWITCH CUP
LIGHT FIXTURE
COVER PLATE
SWITCH CUP CONNECTOR
WIRE CONNECTORS
WHITE WIRES
FAN SWITCH CHAIN
THREADED NIPPLE
CHAIN BUSHING
SOCKET
GLOBE