EMERSON LDO10C Service Manual

LDO10C Series
RoHS
50 Watts C-Class Non-Isolated
Total Power: 50 Watts Input Voltage: 3-13.8 Vdc No. of Outputs: Single
Embedded Power for Business-Critical Continuity
SXX06E Rev. 08.01.06 Page 1 of 2
Rev. 04.30.08
LDO10C
1 of 5
Special Features
•10 A current rating
Adjustable output voltage:
•Excellent transient response
•Power enable (5 pin model)
•Minimum airflow
•Small package
•Termination voltage
capability
•RoHS compliant
Electrical Specifications
Output
Output voltage See Note 5 0.59-5.1 V Output setpoint accuracy 0.1% trim resistors ±1.0% Line regulation Low line to high line ±0.2% Load regulation Full load to min. load ±0.5% Min./max. load 0 A/10 A Overshoot At turn-on 0.5% max. Undershoot At turn-off 100 mV max. Ripple and noise
5 Hz to 20 MHz
Transient response See Notes 1, 2 130 mV max. deviation
Input
Input voltage range 3-13.8 Vdc Input current Minimum load
Input current (max.) See Note 3 10 A @ lo max. Start-up time Power up
See Note 1 20 mV
15 µs recovery to
within regulation band
Remote OFF
Remote ON/OFF
Vin=5 V,
Vout=2.5 V
50 mA
5 mA
3 ms 2 ms
Safety
UL, cUL CAN/CSA 22.2 No. E139421 TÜV Product Service (EN60950) Certificate No. TBD CB Report and Certificate to IEC60950
General
Efficiency (high input) Vin=5 V, Vo=2.5 V, lo=10 A 91% typical Switching frequency Fixed 620 kHz Approvals and standards
(pending)
Material flammability UL94V-0 Weight 1.899 g (0.067 oz.) MTBF 12 V @ 40 °C,
100% load Bellcore 332
Coplanarity Surface mount models 150 µm
> 8,220,210 hours
EN60950
UL/cUL6950
Embedded Power for Business-Critical Continuity
Rev. 04.30.08
LDO10C
2 of 5
Environmental Specifications
Thermal performance See Note 5
Protection
Short-circuit Hiccup, non-latching Overvoltage protection Hiccup, non-latching
Recommended System Capacitance
Input See Note 6 0 µF Output See Note 7 0 µF
Ordering Information
Output
Power (Max.)
50 W 3-13.8 Vdc N/A 0.59-5.1 V 0 A 10 A 94% ±0.2% ±0.5% LDO10C-005W05-VJ 50 W 3-13.8 Vdc N/A 0.59-5.1 V 0 A 10 A 94% ±0.2% ±0.5% LDO10C-005W05-HJ 50 W 3-13.8 Vdc N/A 0.59-5.1 V 0 A 10 A 94% ±0.2% ±0.5% LDO10C-005W05-SJ
Input
Voltage
Operating ambient, temperature Non-operating
Output
OVP Output
Voltage
Current
(Min.)
-40 °C to +70 °C
-40 °C to +125 °C
Output Current
(Max.)
Efciency
(Typical)
Regulation Line Load
Model
Number
(3,5)
Part Number System with Options
3
2
1
4
5
LDO10C
Remote ON/OFF
V
in
GND
R
trim
(for trim down)
C
in
R L O A D
V
ou
t
C
out
Embedded Power for Business-Critical Continuity
Rev. 04.30.08
LDO10C
3 of 5
Product Family
LDO 10 C 00 5W 05 V
Product Family
LDO = C-Class LDO Series
Rated Output Current
Rated Output Current
10 = 10 Amp
Performance
Performance
C = Cost Optimized
Input Voltage
Input Voltage
00 = 3-13.8 V
Number of Pins and
Type of Output
Number of Pins and Type of Output
5W = 5 Pins and Wide Output
Output Voltage
Output Voltage
05 = 0.59-5.1 V
Output Voltage Adjustment of the LDO03C Series
The ultra-wide output voltage trim range offers major advantages to users who select the LDO010C series. It is no longer necessary to purchase a variety of modules in order to cover different output voltages. The output voltage can be trimmed in a range of 0.59-5.1 Vdc. When the LDO03C converter leaves the factory, the output has been adjusted to the default voltage of 0.59 V.
Notes:
1 Measured as per recommended system capacitance. See Application Note 186. 2 di/dt = 10 A/µs, Vin = Nom, Tc = 25 °C, load change = 0.50 lo to full lo and full lo
to 0.50. 3 External input fusing is recommended. 4 Additional part numbers may be available with different output voltages. 5 Airflow dependent, 100 LFM minimum required. 6 No capacitors needed for ripple current capability. 7 No capacitors needed for stability. 8 NOTICE: the input voltage must be greater than the programmed output
voltage. the max duty cycle is 95%. These non-isolated dc-dc modules are buck
converters.
Figure 1: Standard Application Drawing
Mounting Option
Mounting Option
V = Vertical H = Horizontal S = Surface
RoHS Compliance
(8)
J
RoHS Compliance
J = Pb free (RoHS 6/6 compliant) Y = non PB-free (TSE 5/6 compliant)
Mechanical Drawings
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
2 Places ±0.030 (±0.76) 3 Places ±0.010 (±0.25)
0.071 (1.80)
0.650 (16.51)
0.410 (10.41)
4X 0.067 TYP (1.70)
0.16 ± 0.010 (4 ± 0.25)
1
0.050 (1.27) TYP
0.062 (1.57) REF
0.45 (11.35)
0.055 (1.40) REF
0.025 (0.64) ± .001 SQ PINS TYP
5
Dimensions in Inches (mm)
Tolerances (unless otherwise specified)
2 Places ±0.030 (±0.76) 3 Places ±0.010 (±0.25)
0.062 (1.57)
0.025 (0.64)± .001 SQ PIN TYP
0.52 (13.13)
0.125 (3.18) TYP
0.055 (1.40) REF
REF
0.071 (1.80)
0.650 (16.51)
0.410 (10.41)
4X 0.067 (1.70)
TYP
0.035 (0.89)
0.050 (1.27)
0.580 (14.73)
15
6
Vertical Mount
Dimensionsininches(mm).Tolerances(unlessotherwisespecied)2Places±0.030(±0.76)3Places±0.010(±0.25)
Pin Assignments
Pin No. Function
1. Enable
2. Vin
3. Common/RTN
4. Vout
5. Trim
Embedded Power for Business-Critical Continuity
Rev. 04.30.08
LDO10C
4 of 5
Horizontal Mount
Dimensionsininches(mm).Tolerances(unlessotherwisespecied)2Places±0.030(±0.76)3Places±0.010(±0.25)
Pin Assignments
Pin No. Function
1. Enable
2. Vin
3. Common/RTN
4. Vout
5. Trim
6. Mech Pin (Horz/SMT only)
Figure 2: Vertical Mount Mechanical Drawing
Figure 3: Horizontal Mount Mechanical Drawing
0 (0.00)
0.071 (1.80)
0.138 (3.51)
0.205 (5.21)
0.272 (6.91)
0.339 (8.61)
0.050 (1.27)
0.360 (9.14)
0.410 (10.41)
0.650 (16.51)
0.035 (0.89) REF
0.580 (14.73)
0.062 (1.57) REF
0.040 (1.02) REF
0.52 (13.13)
0.055 (1.40) REF
0.125 (3.18) TYP
0.025 (0.64) REF
1
7
6
5
LDO10C­005W05-SJ
Surface Mount
Dimensionsininches(mm).Tolerances(unlessotherwisespecied)2Places±0.030(±0.76)3Places±0.010(±0.25)
Figure 4: Surface Mount Mechanical Drawing
Pin Assignments
Pin No. Function
1. Enable
2. Vin
3. Common/RTN
4. Vout
5. Trim
6. Mech Pin
* This is a Preliminary Datasheet. Emerson
Network Power reserves the right to make changes to the information contained herein without notice and assumes no liability as a result of its use or application.
Embedded Power for Business-Critical Continuity
SXX06E Rev. 08.01.06 Page 1 of 2
Rev. 04.30.08
LDO10C
Americas
5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355
Asia (HK)
1/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong Telephone: +852 2176 3333 Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com techsupport.embeddedpower @emerson.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
Emerson Network Power. The global leader in enabling business-critical continuity.
AC Power Connectivity
DC Power Embedded Computing
Embedded Power
Monitoring Outside Plant Power Switching & controls Precision Cooling Racks & Integrated Cabinets Services
Surge Protection
EmersonNetworkPower. com
Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.
5 of 5