Emerson 24000CVF Instruction Manual

Instruction Manual
D103360X012
24000CVF/SVF Valves
Baumann™ 24000CVF Carbon and 24000SVF Stainless Steel Flanged Control Valves
February 2021
Contents
Introduction 1...................................
Scope of Manual 1.............................
Educational Services 2.........................
Maintenance 3.................................
Installation 3..................................
Air Piping 3...................................
Disassembly 4................................
Lapping the Metal Seat 7.......................
Replacing Packing 7...........................
Actuator and Valve Body Reassembly 7...........
Parts Ordering 8................................
Dimensions and Weights 19......................
Figure 1. Baumann Control Valve with FIELDVUE™ Digital Valve Controller
W9745-3
24000CVF with
DVC6200
W9746-1
24000SVF with
DVC2000
Introduction
The Baumann 24000CVF and 24000SVF line of pneumatic control valves (figure 1) may be used for the control of pressure, temperature, level, and flow. These valves are available with CL150 or 300 and EN PN10-40 flanged end connections.
The high performance 24000CVF and SVF designs feature low deadband and hysteresis, high flow capacity, superb control characteristics, tight shutoff, and advanced packing systems to meet demanding service conditions. The rugged, compact and light weight control valves are ideal for use in tight piping systems where space is a premium.
Scope of Manual
This instruction manual includes installation, maintenance, and parts information for the Baumann 24000CVF carbon steel and SVF stainless flanged control valves.
Do not install, operate, or maintain Baumann 24000CVF or 24000SVF control valves without being fully trained and qualified in valve, actuator, and accessory installation, operation, and maintenance. To avoid
personal injury or property damage, it is important to carefully read, understand, and follow all the contents of this manual, including all safety cautions and warnings. If you have any questions about
these instructions, contact your Emerson sales office
www.Fisher.com
before proceeding.
24000CVF/SVF Valves
February 2021
Instruction Manual
D103360X012
WARNING
Always wear protective gloves, clothing and eyewear when performing any installation operations to avoid personal injury.
Personal injury or property damage caused by sudden release of pressure or bursting of pressure retaining parts may result if service conditions exceed those for which the product was intended. To avoid injury or damage, provide a relief valve for over pressure protection as required by government or accepted industry codes and good engineering practices.
Check with your process or safety engineer for any additional measures that must be taken to protect against process media.
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this instruction manual.
CAUTION
This valve is intended for a specific range of pressures, temperatures and other application specifications. Applying different pressures and temperatures to the valve could result in parts damage, malfunction of the control valve or loss of control of the process. Do not expose this product to service conditions or variables other than those for which the product was intended. If you are not sure what these conditions are you should contact your Emerson sales office complete specifications. Provide the product serial numbers (shown on the nameplate) and all other pertinent information.
for more
WARNING
If you move or work on an actuator installed on a valve with loading pressure applied, keep your hands and tools away from the stem travel path to avoid personal injury. Be especially careful when removing the stem connector to release all loading on the actuator stem whether it be from air pressure on the diaphragm or compression in the actuator springs.
Likewise take similar care when adjusting or removing any optional travel stop. Refer to the relevant actuator Maintenance Instructions.
If hoisting the valve, take care to prevent people from being injured in case the hoist or rigging slips. Be sure to use adequate sized hoists and chains or slings to handle the valve.
Personal injury could result from packing leakage. Valve packing is tightened before shipment; however, the packing might require some readjustment to meet specific service conditions.
Educational Services
For information on available courses for Baumann 24000CVF/SVF valves, as well as a variety of other products, contact:
Emerson Automation Solutions Educational Services - Registration Phone: 1-641-754-3771 or 1-800-338-8158 E-mail: education@emerson.com emerson.com/fishervalvetraining
2
Instruction Manual
D103360X012
24000CVF/SVF Valves
February 2021
Maintenance
WARNING
Avoid personal injury and property damage from sudden release of process pressure or bursting of parts. Before performing any maintenance operations:
D Do not remove the actuator from the valve while the valve is still pressurized.
D Always wear protective gloves, clothing, and eyewear when performing any maintenance operations.
D Disconnect any operating lines providing air pressure, electric power, or a control signal to the actuator. Be sure the
actuator cannot suddenly open or close the valve.
D Use bypass valves or completely shut off the process to isolate the valve from process pressure. Relieve process pressure
on both sides of the valve. Drain the process media from both sides of the valve.
D Depending on the actuator construction, it will be necessary to manage the pneumatic actuator spring
pre-compression. It is essential to refer to the relevant actuator instructions in this manual to perform safe removal of the actuator from the valve.
D Use lock‐out procedures to be sure the above measures stay in effect while you work on the equipment.
D The valve packing box may contain process fluids that are pressurized, even when the valve has been removed from the
pipeline. Process fluids may spray out under pressure when removing the packing hardware or packing rings, or when loosening the packing box pipe plug.
D Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
Note
Whenever a gasket seal is disturbed by removing or shifting gasketed parts, install a new gasket during reassembly. This provides a good gasket seal because the used gasket may not seal properly.
Installation
1. Before installing the valve in the pipeline, thoroughly clean the line of all dirt, welding chips, scale, oil or grease, and
other foreign material.
2. Install the valve so the controlled fluid will flow through the valve body in the direction indicated by the arrow cast
on the valve body.
3. A three-valve bypass must be used to permit removal of the control valve from the line without shutting down the
system.
4. In case of a heat-insulated installation, insulate the valve body only, not the bonnet.
WARNING
To avoid personal injury or property damage, do not attempt to do any work on a valve while the system is in operation. The valve must be isolated 100% from the active system and the isolated line voided of pressure and/or hazardous fluids.
Air Piping
1. For an air-to-extend actuator (air-to-close action), connect the actuating air pressure line to the 1/4 NPT opening in
the upper diaphragm case. For an air-to-retract actuator (air-to-open action) connect the actuating air pressure line to the 1/4 NPT in the lower diaphragm case.
2. Use 6.4 mm (1/4 inch) O.D. tubing or equivalent for all air lines. If air line exceeds 8 m (25 ft) in length, 9.5 mm (3/8
inch) tubing is preferred. Air lines must not leak. Air pressure not to exceed 2.5 barg (35 psig).
3
24000CVF/SVF Valves
February 2021
Instruction Manual
D103360X012
Disassembly
WARNING
If there is evidence of process fluid under pressure leaking from the joint, retighten the valve body/joint nuts. Return to the Warning at the beginning of the Maintenance section to ensure proper steps have been taken to isolate the valve and relieve process pressure.
CAUTION
D When assembling or disassembling the valve, do not turn the valve stem while the plug is touching the valve seat. This
will damage the valve's seating surfaces.
D When adjusting the valve stem, do not grip the stem directly with pliers or a wrench. This will damage the surface of the
stem, and cause damage to the packing in the valve. Instead, counter-tighten the two locknuts (key 27) on the stem (key 5). This will allow you to turn the stem by turning the locknuts (key 27) with a wrench.
D When placing the valve in a vise, do not clamp the rounded sides of the valve. This will distort the shape of the casting,
and will ruin the valve. Caution must be taken not to damage the serrated flange faces.
D Mount the valve in a vise by clamping one flange below the serrated surface. Caution must be taken not to damage the
serrated flange faces.
Actuator Removal
Access to the internal components of the valve body can be accomplished with the actuator removed. For actuator maintenance see the Baumann Pneumatic Actuators Instruction Manual (D103352X012
).
Air-to-Close Actuators
1. Disconnect the air supply to the actuator and remove the air tubing.
2. Loosen the drive nut (key 9) and then remove the plug and stem (keys 4 and 5) assembly by holding the actuator
stem still while unthreading the plug and stem assembly clockwise.
3. Remove the stem locknuts (key 27), travel indicator (key 58), and yoke drive nut (key 9).
4. Remove the actuator from the valve.
Air-to-Open Actuators
1. Using flexible tubing, apply sufficient air pressure to the actuator to lift the plug off the seat.
2. Loosen the drive nut (key 9) and then remove the plug and stem (keys 4 and 5) assembly by holding the actuator
stem still while unthreading the plug and stem assembly clockwise.
3. Remove the stem locknuts (key 27), travel indicator (key 58), and yoke drive nut (key 9).
4. Remove the actuator from the valve.
5. Disconnect the air supply to the actuator and remove the air tubing.
Valve Body Disassembly
1. After removing the actuator, remove the hex nuts (key 12), lift bonnet (key 8), and plug and stem
(keys 4 and 5) from the valve body (key 1). A new valve body gasket (key 49) should be installed each time the valve is disassembled.
2. Loosen the packing spring load by removing the packing follower (key 10).
4
Instruction Manual
D103360X012
24000CVF/SVF Valves
February 2021
Remove the plug and stem assembly by pulling it out through the bottom of the bonnet (key 8) while rotating the stem (key 5). This will help prevent damage to the packing components.
Note
Handle the parts carefully to avoid damaging the seating and guiding surfaces. Wipe the parts with a clean soft cloth and examine for signs of wear or damage.
3. Use a seat ring tool made according to the dimensions in figure 2 and table 1 to remove the seat ring (key 2) as
follows:
a. Insert the tool into the valve body. Be certain the tool lugs are engaged in the corresponding recesses in the seat
ring.
b. Use a 1/2 inch drive breaker bar or impact wrench having sufficient torque capability to remove the seat ring.
Seat ring installation torque is provided in table 2 for reference. Connect the breaker bar or impact wrench, and if needed, a impact-rated extension bar, to the square drive of the seat ring tool.
c. Remove the seat ring (key 2) from the valve body. Make sure the seat ring tool is held at a right angle to the seat
ring during removal to prevent the tool from disengaging from the lugs of the seat ring.
d. Inspect parts for wear or damage that would prevent proper operation of the valve body.
Figure 2. Seat Ring Tool Dimensions
C
A
A
C
E
E
.502.508
SQUARE DRIVE
D
D
B
F
F
1
A
D
CC
.502.508
SQUARE DRIVE
B
1
A
B
D
C
NPS 1/2, 3/4, 1
NPS 1/2, 3/4, 1
1
MAX ALLOWABLE CENTER DRILL  0.532
NPS 1 1/2
NPS 2
5
24000CVF/SVF Valves
February 2021
Instruction Manual
D103360X012
Table 1. Seat Ring Tool Dimensions (see figure 2)
Part Number DN NPS
GE96219X012
GE96219X022 25 1 1.52 2.3 0.40 0.25 0.35 0.20
GE96219X032 40 1-1/2 2.06 0.9 0.55 0.30 - - - - - -
GE96219X042 50 2 2.74 1.0 0.55 0.44 - - - - - -
15 20
1/2 3/4
A B C D E F
Inch
1.32 2.0 0.38 0.26 0.29 0.19
Table 2. Seat Ring Assembly and Torque Tool
VALVE SIZE
NPS (Inch)
24000CVF/SVF
151 Low Flow 177 Low Flow
0.375
Port Diameter
Installation Torque (lbwft) 80 80 80 100 100
1. Male end used for trim 151,177, and port diameters .25 and .375
2. Female end used for port diameters .8125 and 1.0625
0.8125
1.0625
(1)
(1)
(1)
0.25
(1)
(2)
(2)
1.25 - - - - - - - - - GE96219X032 - - -
1.5 - - - - - - - - - GE96219X032 GE96219X042 2 - - - - - - - - - - - - GE96219X042
1/2
(15)
GE96219X012 GE96219X012 GE96219X022 - - - - - ­GE96219X012 GE96219X012 GE96219X022 - - - - - ­GE96219X012 GE96219X012 GE96219X022 - - - - - ­GE96219X012 GE96219X012 GE96219X022 - - - - - ­GE96219X012 GE96219X012 GE96219X022 - - - - - -
- - - - - - GE96219X022 - - - - - -
3/4
(20)
(DN)
1
(25)
1-1/2
(40)
2
(50)
4. Low Flow Trims:
e. For Baumann 151 trim (figure 5) unscrew the seat subassembly (key 51) from the seat ring (key 2) with a 5/8
inch socket wrench. When reassembling, hand tighten the subassembly (key 51) and then rotate 1/8 of a turn with the 5/8 inch socket to lock in place.
Note
If changing to Baumann 151 trim, for correct flow characteristics, be sure the valve is reversed in the pipeline so that flow direction is flow down.
f. For Baumann 177 trim (figure 6) unscrew the retainer nut (key 24) using a 3/4 inch socket wrench. Remove the
gland (key 23) and insert (key 25). Replace the insert (key 25), making sure that the tapered portion faces up. If replacement of the housing (key 26) is required, use a 5/8 inch socket wrench.
5. NOLEEK Bellows Trim: Refer to figure 7 and table 9. Hold the bellows bonnet and push down on the stem to expose the plug retaining pin (key 21). Using a small punch, tap pin (key 21) out. To replace the new plug retaining pin (key
21), be sure the plug and stem are aligned to expose the hole (figure 7). With a needle nose pliers, slide the pin (key
21) into the hole.
WARNING
Be sure the plug retaining pin (key 21) is flush inside the hole and not exposed on either side of the plug or damage could happen to the bonnet interior.
6
Loading...