Electrolux DE 6250, DE 6260, CHDE 6260 User Manual

DE 6250 DE 6260 CHDE 6260 335 D
Dunstabzugshaube Afzuigkap Hotte Cooker Hood
Montage- und Gebrauchsanweisung Installatie- en gebruiksaanwijzing Notice d’utilisation et d’installation Operating and Installation Instructions
Contents
Safety warnings 3 8
For the user 3 8 For the installer 3 8
Description of the Appliance 4 0
Extractor version 40 Recirculation Version 40
Hood Operation 4 1
Maintenance and care 41
Metal grease filter 42 Open the metal grease filter 42 Charcoal filter 43 Changing the light bulb 44
What to do if 45
Service and spare parts 4 6
Technical Details 47
Electrical connection 4 7
Printed on recycled paper AEG - putting words into action
37
Safety warnings
For the user
The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam.
Always cover lighted elements, to prevent excess heat from damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames.
Also, when frying, keep the deep frying pan on the cooker top/cooker under careful control.
The hot oil in the frying pan might ignite due to overheating.
The risk of self-ignition increases when the oil being used is dirty .
It is extremely important to note that overheating can cause a fire.
Never carry out any flambé cooking under the hood.
Always disconnect the unit from the power supply before
carrying out any work on the hood, including replacing the light bulb (take the cartridge fuse out of the fuse holder or switch off
the automatic circuit breaker).
It is very important to clean the hood and replace the filter at the recommended intervals. Failure to do so could cause grease deposits to build up, resulting in a fire hazard.
For the installer
When used as an extractor unit, the hood must be fitted with a 120mm diameter hose.
When installing the hood, make sure you respect the following minimum distance from the top edge of the cooking hob/ring surfaces: electric cookers 600 mm gas cookers 650 mm coal and oil cookers 700 mm min.
The national standard on fuel-burning systems specifies a maximum depression of 0.04 bar in such rooms.
The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed.
The air outlet installation must comply with the regulations laid down by the relevant authorities.
When the unit is used in its extractor version, a sufficiently large ventilation hole must be provided, with dimensions that are approximately the same as the outlet hole.
38
National and regional building regulations impose a number of restrictions on using hoods and fuel-burning appliances connected to a chimney , such as coal or oil room-heaters and gas fires, in the same room.
Hoods can only be used safely with appliances connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approximately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood.
If you have any doubts, contact the relevant controlling authority or building inspectors office.
Since the rule for rooms with fuel burning appliances is outlet hole of the same size as the ventilation hole, a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood.
If the hood is used in its filtering function, it will operate simply and safely in the above conditions without the need for any of the aforementioned measures.
When the hood is used in its extractor function, the following rules must be followed to obtain optimal operation:
short and straight outlet hose keep bends in outlet hose to a minimum never install the hoses with an acute angle, they must
always follow a gentle curve only keep the hose as large as possible (preferably the same diameter as the outlet hole).
Failure to observe these basic instructions will drastically reduce the performance and increase the noise levels of the extractor hood.
39
Description of the Appliance
The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam.
The hood is supplied as an extractor unit and can also be used in a recirculation mode by fitting one charcoal filter (available from your local Service Force Centre).
Extractor version
In this version fumes are extracted to the outside via a hose.
In order to obtain the best performance the hose should have a
diameter equal to the outlet hole.
Recirculation Version
The air is filtered through a charcoal filter and returned to the kitchen.
Y ou will need an original AEG charcoal filter for the recirculation
function. (Available from your local Service Force Centre).
Insert the charcoal filter into the lugs of the frame above using the 2 red lugs E to retain it, press the red lugs inwards, and insert the charcoal filter in the frame. Fig. 1.
40
E
E
E
Fig. 1
Hood Operation
Best results are obtained by using a low speed for normal conditions and high speed when odours are more concentrated. Turn the hood on a few minutes before you start cooking then you will get an underpressure in the kitchen. It should be left on after cooking for about 15 minutes or until all odours have disappeared. The control switches are located on the units front panel:
ON OFF Intensive speed
Light switch
The hood is also equipped with a micro-switch which can be found under the lower runner of the visor on the right hand side.
With this micro-switch, the appliance may be automatically switched on and off by opening and closing the pull-out panel, but only if the fan speed has already been set and the light button is turned to I”.
Motor switch
Maintenance and care
The hood must always be disconnected from the electricity supply before beginning any maintenance work.
Never insert pointed objects in the motors protective grid.
Wash the outside surfaces using a delicate detergent solution. Never
use caustic detergents or abrasive brushes or powders.
Only ever clean the switch panel and filter grille using a damp cloth and delicate detergents.
It is extremely important to clean the unit and change the filters at the recommended intervals. Failure to do so will cause grease deposits to build up that could constitute a fire hazard.
41
Metal grease filter
The purpose of the grease filters is to aspirate grease particles which form during cooking and it must always be used, either in the external evacuation or internal recycling function. Attention: the metal grease filters must be removed and washed, either by hand or in the dishwasher, every four weeks.
Open the metal grease filter
Model CHDE 6260:T o remove the grease filters, first pull the handles upwards, then extract the filter outwards. Fig. 2a.
Model 335 D:T o remove the grease filters, first remove the grid (see Fig. 2a) and take out the grease filters oushing on the locking springs Z. Fig. 2b.
Hand washing
Soak grease filters for about one hour in hot water with a grease­loosening cleaner, then rinse of f thoroughly with hot water . Repeat the process if necessary . Refit the grease filters when they are dry .
Dishwasher
Place grease filters in the dishwasher. Select most powerful washing programme and highest temperature, at least 65°C. Repeat the process. Refit the grease filters when they are dry . When washing the metal grease filter in the dishwasher a slight discolouration of the filter can occur, this does not have any impact on its performance.
Clean the inner housing using a hot detergent solution only (never use caustic detergents, abrasive powders or brushes).
42
Z
Fig. 2a Fig. 2b
Charcoal filter
The charcoal filter should only be used if you want to use the hood in the recirculation function.
T o do this you will need an original AEG charcoal filter (available from your local Service Force Centre).
The charcoal filter cannot be washed nor regenerated. The charcoal filter should be replaced every 12 months under normal use. Replacement filters are available from your local Service Force Centre.
Fitting the charcoal filter:
Insert the charcoal filter into the lugs of the frame above using the 2 red lugs E to retain it, press the red lugs inwards, and insert the charcoal filter in the frame. Fig. 3.
Removing:
Press both red lugs E upwards (towards the inside of the housing) and remove the charcoal filter downwards. Bild. 3.
Always specify the hood model code number and serial number when ordering replacement filters. This information is shown on the registration plate located on the inside of the unit.
The charcoal filter can be ordered from your local Service Force Centre.
E
E
E
Fig. 3
43
Warning
Failure to observe the instructions on cleaning the unit and changing the filters will cause a fire hazard. Y ou are therefore strongly recommended to follow these instructions.
The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations.
Changing the light bulb
Disconnect the cooker hood from the main supply .
Remove the grease filter/s or the grid (model 335 D).
Replace the old bulb with a new one of the same type.
Refit the grease filter/s or the grid.
If the light does not come on, make sure the bulb has been inserted
correctly before contacting your local Service Force Centre.
44
What to do if
If your appliance fails to work properly please carry out the following checks.
Symptom Solution
The cooker hood will not start... Check that:
The hood is connected to the electricity supply. Check that a fan speed has been selected
The cooker hood is not working Check that: effectively .. The fan speed is set high
enough for the task. The grease filters are clean. The kitchen is adequately vented to allow the entry of fresh air. If set up for recirculation, check that the charcoal filter is still effective. If set up for extraction, check that the ducting and outlets are not blocked.
The cooker hood has The safety cut-out device has been switched off during operation... tripped.
Turn off the hob and then wait for the device to reset. If the hood has been installed below the heights indicated in the installation instructions the motor will cut-out frequently which will damage the hood.
If after all these checks, the problem persists, contact your local Service Force Centre, quoting the model and serial number. Please note that it will be necessary to provide proof of purchase for any in-guarantee service calls. In-guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown.
45
Service and spare parts
In the event of your appliance requiring service, or if you wish to purchase spare parts, contact your local AEG Service Force Centre by telephoning
08705 929 929
Y our call will be automatically routed to the Service Centre covering your post code area. For the address of your local Service Force Centre and further informa­tion about Service Force, please visit the website at www.serviceforce.co.uk
Please ensure that you have read the section What to do if.... as the
engineer will make a charge if the fault is not a mechanical or electrical breakdown even the appliance is under warranty .
Please note that proof of purchase is required for in-guarantee service calls.
Help us to help you
Please determine your type of enquiry before writing or telephoning. When you contact us we need to know:
Y our name
Address and post code
T elephone number
Clear and concise details of the fault
Name and model of the appliance*
E number*
* This information can be found on the rating plate, which can be seen when the grease filters are removed.
46
Technical Details
Model: CHDE 6260 335D
DE 6260 DE 6250
Maximum absorbed power: 330 W 230 W
Fuse rating: T6A 250V T6A 250V Motor absorption: 2 x 125 W 1 x 150 W Lighting: 2 x 40 W 2 x 40 W Duct diameter Ø 120 mm Ø 120 mm
Length of the cable: 150 cm 150 cm
Electrical connection
Safety warnings for the electrician
The electric outlet should be placed on the wall inside the chimney . The hood has a power cable, 150 cm, with earth connection and the rated voltage is 220 - 240 V (CHDE 6260/335D) - 230V (DE 6260 - DE 6250).
Connect the hood to the mains supply via a double pole switch which has 3 mm minimum separation between the contacts. The switch must be accessible at all times. The following is valid in the United Kingdom only:
- the wire which is coloured green and yellow must be connected to the terminal which is marked with the letter E or by the earth symbol ( ), or coloured green or green and yellow;
- the wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black, -
- the wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.
47
600
120
C
C:4.1
C:4.2
A
B
1
2
3
C:4
D
D:4
5
6
7
3 x 2,9x13 mm
4 x 5,0x45 mm (DE 6260) 2 x 5,0x45 mm (DE 5260)
2 x
(DE 6260)
4 x 8 mm (DE 6260) 2 x 8 mm (DE 5260)
C
600
130
400 min
340
130
560 min
135
599
400
270
650 min
120
135
560
11 - 3.1
8
9
10
11 - 3.2
B
2 x
10 x 4,5x13 mm (DE 6260)
8 x 4,5x13 mm (DE 6250)
6 x 4,5x16 mm
566
420 min.
340
270
650 min
D
2 3
DE 6250-ml DE 6260-ml
A
AEG Hausgeräte GmbH Postfach 1036 D-90327 Nürnberg
http://www.aeg.hausgeraete.de
© Copyright by AEG
LI1R6A
1
2
6
2,9 x 13 mm
2,9 x 13 mm
3
Ø 120 mm
Ø 120 mm
3.1
3.2
54 - 100 mm
4 x 4,5x13
(330 D - 350 D )
2 x 4,5x13
(430 D - 450 D)
7
a
ab 0
17 - (C) 16 33 19
36
}
b
(D)
6 x 4,5x13
=
=
8
4 6
C: 4.2
C:4
3 x 4,5x16
153
D:4
153
600 528
35
¯ 8 mm
510
9
348
4
5
19 mm
C:4.1
DE 6250
10
330/350 D
100/120 mm Ø
11
5 7
3.1
120 mm Ø
3.2
430/450 D
16 - 20 mm
120 mm Ø
AEG Hausgeräte GmbH Postfach 1036 D-90327 Nürnberg
http://www.aeg.hausgeraete.de http://www.aeg.co.uk
© Copyright by AEG
LI1R7B Ed. 07/02