Setting up the ULTRASAVER
Filling barrels
1
2
3
4
5
6
7
8
9
Note: Clean, dry, filtered air is required to meet warranty. If necessary, use five-micron filter regulator (not supplied – order #2000F755).
1. Connect ULTRASAVER (or filter regulator where required) to plant air supply.
2. If appropriate, connect ULTRASAVER to filter regulator. Press air hose firmly into fittings to connect.
3. Set plant air supply (or filter regulator) within 80 to 100 psi (5.4 to 7.0 bar).
4. Plug in the foot pedal.
5. Set voltage selector switch to the proper value.
6. Connect power cord.
7. Attach the hose support to desired side of the ULTRASAVER.
8. Position barrel adapter hose in the support and connect to the ULTRASAVER’s output.
9. Turn power switch on (rear panel).
Thin, pourable fluids
Twist on a tip cap and pour fluid in.
If appropriate, insert the SmoothFlow™ piston.
Carefully press the piston down (use a pen or pencil) until it contacts the fluid
.
Attach barrel to barrel adapter assembly.
Invert barrel, replace tip cap with selected dispense tip.
Thick or non-leveling materials
Same procedure as with thin, pourable fluids EXCEPT:
Spoon fluid into the barrel with a spatula. (If packed in a 1/10 gallon cartridge, try loading the barrel with a caulking gun.)
Note: Move the fluid toward the bottom of the barrel by pressing the SmoothFlow™ piston. Squeeze barrel sides slightly to allow trapped air to escape.
Solvents, cyanoacrylates or anaerobics
Same procedure as with thin, pourable fluids EXCEPT:
Use the blue LV Barrier™. Place barrier in the TOP of the barrel reservoir.
Allow air between barrier and fluid. (Do not contact the blue barrier to the fluid.)
1/2 max. fill
Air gap
LV Barrier™
Caulking gun
or spatula
2/3
max.
fill
2/3
max.
fill
THICK fluid settings
30
5
5
3
5
5
3
Press the mode switch so the yellow light is lit.
Hold the barrel at 45˚.
Place tip on work surface.
Use the foot pedal to control flow.
THIN fluid settings
1. Set air pressure to 30 psi
2. To fill tip, set mode switch to steady (yellow light on) and press foot pedal.
3. If dots are required, reset mode switch to green. Set time at #3, adjust as necessary.
1. Set air pressure to 2 psi
2. Set time at #3
3. If drop forms at tip, turn vacuum control counter-clockwise until drop disappears.
Note: Settings are general recommendations. For best results, test settings for your specific application.
How to make DOTS
Time range adjustments – special setups
Most applications work best with ULTRASAVER’s default time setting (shipped with 0.010 – 1.000 momentary). However, for special setups the ULTRASAVER’s time range may be adjusted with the rotary switch located under the plug in the bottom panel of the cabinet.
To change the time range, rotate the switch to the desired setting using a small screwdriver. Replace plug.
In maintained mode, the foot pedal must remain depressed throughout the entire dispense cycle. Releasing the pedal during a cycle will interrupt the cycle.
In momentary mode, the foot pedal can be pressed and immediately released, and the cycle will continue. If the pedal is pressed again during a cycle, the dispenser will stop.
Time range in seconds
Switch Setting
Foot pedal
Mode
0 0.005 – 0.200 Momentary
1 0.010 – 1.000 Momentary 2 0.050 –10.000 Momentary 3 0.100 –20.000 Momentary
4 0.015 –30.000 Momentary
5 0.005 – 0.200 Maintained 6 0.010 – 1.000 Maintained 7 0.050 –10.000 Maintained
8 0.100 –20.000 Maintained 9 0.015 –30.000 Maintained
How to make STRIPES
GREEN
YELLOW
MODE SWITCH
MODE SWITCH
Press the mode switch so the green light is lit.
Hold the barrel at 45˚.
Place tip on work surface. Press the foot pedal to repeat the same size dot.
+
+
0
1
2
3
4
5
6
7
8
9
1
0
R
psi
100 x kPa
bar
0
50
100
10
90
40
30
20
60
70
80
0
1
2
3
4
5
6
7
1200 656964
Technical specifications
Input voltage: 100-120/208-240 VAC, 50/60 Hz, 8VA max.
Fuse rating: 80 mA, 250V, Type T
Air input 80 – 100 psi (5.5 – 6.9 bar) pressure: Use only clean, dry, filtered air –
minimum 20 micron
Air output 1200: 0 – 100 psi (0 – 6.9 bar) pressure: 1215: 0 – 15 psi (0 – 1.03 bar)
Dimensions: 4-3/4" w x 6" h x 5-1/2" d
(120.7mm x 152.4mm x 139.7mm)
Weight: 2.78 lbs. (1.26 kg)
Enclosure rating: NEMA 1 or IP100
Time ranges: 0.005 – 0.200 seconds
0.010 – 1.000 seconds (momentary, default)
0.050 – 10.000 seconds
0.100 – 20.000 seconds
0.015 – 30.000 seconds
Dispense pressure gauge
Fuse
T 80mA 250V
100-120/208-240 VAC
50/60 Hz 8 VA max.
115V
Model No.
Serial No.
Providence, RI 02914 U.S.A. Telephone: (401) 434-1680
1200 656964
Dispense pressure
regulator
Air output quick-connect
Barrel vacuum control
Time control
Mode switch
Exhaust
Air input quick-connect
Foot pedal receptacle
Input voltage selector switch
Fuse holder
Power switch
Power cord receptacle
Headquarters: 977 Waterman Avenue, East Providence, RI 02914-1342 USA USA: 800-556-3484 Mexico: 001-800-556-3484 Telephone: 401-434-1680 Fax: 401-431-0237 e-mail: ultrasaver@efd-inc.com www.efd-inc.com
Unit 14, Apex Business Centre, Boscombe Road Dunstable, Bedfordshire LU5 4SB UK Telephone: 01582 666334 Fax: 01582 664227 Freephone: 0800 585733 From Ireland: 00800 8272 9444
Sales and service of EFD dispensers and dispensing components are available through EFD authorized distributors in over 30 countries. Please contact EFD U.S.A. for specific names and addresses.
©2006 EFD, Inc. 1200-MAN-01 v010606
®
A NORDSON COMPANY
EFD Two Year Limited Warranty
For assistance or to order EFD ULTRA dispensing components, contact your local EFD authorized distributor.
All components of EFD dispensers are warranted to the original end user for two years from date of purchase.
Within the period of this warranty, EFD will repair or replace free of charge any defective component on return of the part, or the complete dispenser, prepaid to the factory.
In no event shall any liability or obligation of EFD arising from this warranty exceed the purchase price of the equipment. Before using, user shall deter­mine the suitability of the product for his intended use, and user assumes all risk and liability whatsoever in connection therewith. This warranty is valid only when clean, dry, filtered air is used.
EFD makes no warranty whatsoever of merchantability or fitness for a particular purpose. In no event shall EFD be liable for incidental or consequential damages.
This equipment is regulated by the European Union under WEEE Directive (2002/96/EC). See www.efd-inc.com for information about how to properly dispose of this equipment.
50
40
30
3
4
2
20
1
10
bar
100 x kPa
0
0
psi
60
70
R
5
80
6
90
7
100
+
0
1
+
Loading...