Druck PTX7200 Data sheet

PTX
7200
The PTX 7200 Series combines modular design with the latest advances in ASIC technology and surface mount electronics. This provides a lightweight, highly reliable
and cost-effective solution for a range
of industrial pressure
important. The rugged design with exceptional RFI/EMI immunity gives the PTX 7200 the lowest “cost-of-ownership” in the industry.
At the heart of the transmitter is Druck’s own piezoresistive silicon technology, extensively proven in aerospace, sub-sea, oil-field and many other applications where the highest levels of performance and long-term reliability are required.
The sensor features a Hastelloy C276 isolation diaphragm and is enclosed in an electron beam weld­ed 316L stainless steel body. This rugged construction ensures full compatibility with a wide range of pressure media and operating conditions.
On-site trimming of the transmitter output is accomplished via non-interacting potentiometers located beneath the electrical connector. The PTX 7200 Series offers excellent RFI/EMI immunity, meeting the highest level of CE marking requirements for Heavy Industrial use.
PTX 7200 Series
Industrial Pressure Transmitters
Any range between 1 and 10,000 psi
±0.2% FS accuracy to ±0.1% FS available
NACE compatible Hastelloy C276 and 316L SS
RFI/EMI protected to CE Heavy Industrial Standard
Intrinsically safe versions available
Exceptionally rugged and lightweight
Operating temperature range -40° to 210°F
PDS-A144 03/03
g
GE Druck
Druck Incorporated 4 Dunham Drive, New Fairfield, CT 06812 USA Tel: 203-746-0400, Fax: 203-746-2494 Email: usa.sales@druck.com www.druck.com www.pressure.com
Code Electrical connection
STANDARD SPECIFICATION
Pressure Measurement
Operating Pressure Ranges
Any pressure unit and (zero-based) span available between 1 and 1000 psi gauge; between 1001 and 10,000 psi sealed gauge and between 5 and 10,000 psi absolute Compound ranges -15 to 15, -15 to 30, -15 to 100,
-5 to 5 psi g Negative ranges refer to PTX 500/600
Alternate pressure units may be specified on order.
Proof Pressure
6X FS for ranges 7.25 psi and below 4X FS for ranges 30 psi and lower 3X FS (3000 psi max) for ranges 2000 psi and lower 2X FS (15,000 psi max) for ranges 10,000 psi and lower
Burst Pressure
8X FS for gauge ranges 7.25 psi and lower 6X FS for gauge ranges 30 psi and lower 4X FS (3500 psi max) for ranges 1000 psi and lower 3500 psi for absolute ranges 2000 psia and lower 15,000 psi for ranges above 2000 psi
Pressure Media Compatibility
Fluids compatible with a welded assembly of Hastelloy C276 and 316L SS (NACE MR-01-75 compatible grades)
Supply Voltage
9 to 30 Vdc at the transmitter terminals (9-28 Vdc for IS units) Maximum load ()=50x(V
Supply
-9)
Warmup Time
500 ms max at power-up
For pulse power applications refer to the PTX 500/600
Response Time
1 msec
Supply Sensitivity
0.005% FS/volt
Insulation Resistance
>10M@ 500 Vdc (@68°F)
Surge Protection (between connectors & case)
Ranges up to 2000 psi withstands 2kV spike Ranges above 2000 psi withstands 1kV spike
Representative
INSTALLATION DRAWINGS: Dimensions in inches
PTX 7200 Series
Industrial Pressure Transmitters
Spike test conforms to EN61000-4-4, EN61000-4-5 Between electrical connectors and case.
Output
2-wire, 4-20mA
Performance
Accuracy
Combined non-linearity, hysteresis and repeatability ±0.2% FS BSL
For improved performance, see Option A.
Zero Offset and Span Setting
Factory set ±0.05mA. Further ±5% FS user adjustment available via non-interacting potentiometers
Long Term Stability
±0.1% FS/year
Operating Temperature Range
-40 to 210°F for non-cabled models
-40 to 175°F for PTX 7211
-40 to 250°F process media
Temperature Effects
±1% FS TEB over 14 to 122°F ±2% FS TEB over -5 to 175°F
For improved performance, see Option A.
CE Conformity
EMC Emissions: EN50081.1, EN55022 EMC Immunity: EN61000-6-2
10V/m Heavy Industrial
Physical
Pressure Connection
1/4” NPT female
Optional adapters available
Electrical Connection
3 feet integral cable (longer lengths available) 6 pin bayonet connector DIN 43650A plug/socket
For gauge ranges up to 1000 psig PTX 7211 and PTX 7217 require vented cable
Weight
7 oz. nominal
Acceleration Sensitivity
0.1%FS/g for 5 psi range decreasing to
0.005%FS/g for 150 psi range
Mechanical Shock
1000g half sine wave, pulse duration 1ms and 100g peak half sine wave, duration 11ms, both in each of 3 mutually perpendicular axes will not affect calibration
Vibration
Conforms to MIL-STD 810C, Method 514.2-2 Curve L
ORDERING INFORMATION
(1) Select model number
1 Integral cable 6 6-pin bayonet 7 DIN 43650A plug/socket
Code Model
PTX 721 Base model
Continuing development sometimes necessitates specification changes without notice.
Druck is an ISO 9001 registered company.
PTX 721 1 Typical model number
(2) Pressure range/units required (3) Options (if required)
OPTIONS
Option A Improved Performance
±0.1% FS BSL ±0.7% FS TEB over 14 to 122°F ±1.5%FS TEB over -5 to 175°F
Intrinsic Safety Approval
FM Class I, Div 1, Groups A,B,C,D
For CSA certifications refer to PTX 500/600
BAS 01 ATEX 1254 EEx ia IIC T4 (-40°C < T
amb
< 80°C)
Pressure Port Adapters
1/4” NPT male to 1/4” NPT male PN182-141-01 1/4” NPT male to 1/2” NPT female PN182-143-01 1/4” NPT male to 7/16”-20UNF (1/4 AN) PN182-142-01
All ada
pters 316 SS construction
Calibration Certificate
PTX 7211
PTX 7216
PTX 7217
WIRING DETAILS
+EXC -EXC
CASE
PTX 7211 RED BLUE
PTX 7216 PIN A PIN B
PTX 7217 PIN 1 PIN 2
Loading...